MEANWELL QP

QP-375
375W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH3,4 are isolated from other outputs and the polarity can be reversed
No minimum load requirement for CH2,3,4
All output can be adjustable from -5~+10%
With power good and fail signal output
Built-in remote ON-OFF control
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
OUTPUT
QP-375-5A
QP-375-5C
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
+5V
+12V
12V
12V
+5V
+12V
12V
5V
+5V
+12V
15V
15V
RATED CURRENT
30A
10A
6A
3A
30A
10A
6A
3A
30A
9A
4A
4A
CURRENT RANGE
3.5 ~ 40A 0 ~ 16A
0 ~ 6A
0 ~ 3A
3.5 ~ 40A 0 ~ 16A
0 ~ 6A
0 ~ 3A
3.5 ~ 40A 0 ~ 16A
0 ~ 4A
0 ~ 4A
RATED POWER(max.)
378W
357W
378W
RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 50mVp-p 100mVp-p 120mVp-p 120mVp-p 50mVp-p 100mVp-p 150mVp-p 150mVp-p 240mVp-p
4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V 11.4 ~ 13.2V 4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V ------
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V 11.4 ~ 13.2V 14.3 ~ 16.5V 14.3 ~ 16.5V
VOLTAGE TOLERANCE Note.3
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
36ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
1.0%
800ms, 50ms at full load
SETUP, RISE TIME
INPUT
QP-375-5B
Note.7 85 ~ 264VAC
120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
77%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
6A/115VAC
3A/230VAC
COLD START 45A
PF>0.98/115VAC at full load
77%
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
77%
CH1:5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
80
5 (TSW1) Detect on heatsink of Q1,Q2 power transistor)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms
FUNCTION
RC+/RC-:0 ~ 0.8V POWER ON; 4V ~ 10V POWER OFF
REMOTE CONTROL
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
75.9K hrs min.
DIMENSION
280*127*63.5mm (L*W*H)
2.4Kg; 6pcs/14.8Kg/0.89CUFT
PACKING
NOTE
-10 ~ +60
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Peak current can not exceed 60 sec.
6. Isolated CH3 & CH4 maybe series connected or can be used as positive or negative outputs.
7. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-375-SPEC 2011-08-19
QP-375
375W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections:Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH3,4 are isolated from other outputs and the polarity can be reversed
No minimum load requirement for CH2,3,4
All output can be adjustable from -5~+10%
With power good and fail signal output
Built-in remote ON-OFF control
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
QP-375-5D
MODEL
OUTPUT
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
+5V
+12V
12V
24V
+5V
+12V
24V
24V
RATED CURRENT
30A
9A
4A
3A
30A
9A
3A
2A
CURRENT RANGE
3.5 ~ 40A
0 ~ 16A
0 ~ 6A
0 ~ 3A
3.5 ~ 40A
0 ~ 16A
0 ~ 4A
0 ~ 3A
RATED POWER(max.)
378W
120mVp-p
120mVp-p
240mVp-p
100mVp-p
120mVp-p
120mVp-p
240mVp-p
11.4 ~ 13.2V
11.4 ~ 13.2V
22.8 ~ 26.4V
4.75 ~ 5.5V
11.4 ~ 13.2V
22.8 ~ 26.4V
22.8 ~ 26.4V
378W
RIPPLE & NOISE (max.) Note.2 100mVp-p
4.75 ~ 5.5V
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
800ms, 50ms at full load
SETUP, RISE TIME
36ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
QP-375-5E
Note.7 85 ~ 264VAC
120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
78%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
6A/115VAC
3A/230VAC
COLD START 45A
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
PF>0.98/115VAC at full load
78%
CH1:5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
80
5 (TSW1) Detect on heatsink of Q1,Q2 power transistor)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms
FUNCTION
RC+/RC-:0 ~ 0.8V POWER ON; 4V ~ 10V POWER OFF
REMOTE CONTROL
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
OTHERS
EMC EMISSION
(Refer to "Derating Curve")
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
DIMENSION
280*127*63.5mm (L*W*H)
2.4Kg; 6pcs/14.8Kg/0.89CUFT
PACKING
NOTE
-10 ~ +60
20 ~ 90% RH non-condensing
75.9K hrs min.
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Peak current can not exceed 60 sec.
6. Isolated CH3 & CH4 maybe series connected or can be used as positive or negative outputs.
7. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-375-SPEC 2011-08-19
QP-375
375W Quad Output with PFC Function
Mechanical Specification
Case No. 927A
series
Unit:mm
92
63.5
250
+V2 ADJ.
9.5
8.2
I/P
1
2
3
+V3 ADJ.
+V4 ADJ.
37
1 6
99.1
99.1
113
6-M3 L=6
127
8.2
8-M4 L=6
CN62
42.5
30.4
165.1
+V1 ADJ.
TB1
1
2
3
4
5
6
7
8
9
10
9.5
O/P
TB2
5
7
LED
Air flow
direction
165.1
165.1
240
42.4
31.7
13.9
10.1
280
2-M4 L=6
CN62 Pin No. Assignment : JST S6B-XH or equivalent
AC Input Terminal
Pin No. Assignment
Pin No.
1
2
3
Pin No.
Assignment
Mating Housing
Terminal
1
PF(Power good / Fail signal)
GND
2
RS3
JST XHP
JST SXH-001T-P0.6
RS+
or equivalent
or equivalent
4
RC5
RC+
6
DC Output Terminal Pin No. Assignment
Assignment
AC/L
AC/N
FG
Pin No.
1,2
3,4,5
6
7
Assignment
+V1
COM(V1 and V2)
+V2
+V3
Pin No.
8
9
10
Assignment
-V3
+V4
-V4
Block Diagram
fosc : 100KHz
POWER SWITCHING
PWM CONTROL
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
RECTIFIERS
&
P.F.C.
FAN
POWER
SWITCHING
RECTIFIERS
&
FILTER
REGULATOR
MA &
CONTROL
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
MA &
CONTROL
RECTIFIERS
&
FILTER
+V4
-V4
+V3
-V3
+S
+V1
COM
-S
+V2
PF
FG
O.L.P.
O.T.P.
PF
PWM
CONTROL
Derating Curve
O.V.P.
DETECTION
CIRCUIT
+RC
-RC
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
60
50
40
85
95
105
115
125
135
180
230
264
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-375-SPEC 2011-08-19
QP-375-24
375W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH3,4 are isolated from other outputs and the polarity can be reversed
No minimum load requirement for CH2,3,4
All output can be adjustable from -5~+10%
With power good and fail signal output
Built-in remote ON-OFF control
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
OUTPUT
QP-375-24B
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
+24V
+5V
12V
12V
+24V
+5V
15V
15V
RATED CURRENT
10A
10A
4A
4A
10A
10A
4A
4A
CURRENT RANGE
1 ~ 10A
0 ~ 16A
0 ~ 4A
0 ~ 4A
1 ~ 10A
0 ~ 10A
0 ~ 4A
0 ~ 4A
RATED POWER(max.)
386W
410W
RIPPLE & NOISE (max.) Note.2 240mVp-p
21.6 ~ 26.4V
VOLTAGE ADJ. RANGE
50mVp-p
120mVp-p
120mVp-p
240mVp-p
50mVp-p
150mVp-p
150mVp-p
4.5 ~ 5.5V
10.8 ~ 13.2V
10.8 ~ 13.2V
21.6 ~ 26.4V
4.5 ~ 5.5V
13.5 ~ 16.5V
13.5 ~ 16.5V
VOLTAGE TOLERANCE Note.3
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
0.8%
800ms, 50ms at full load
SETUP, RISE TIME
36ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
QP-375-24C
Note.7 85 ~ 264VAC
120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
78%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
6A/115VAC
3A/230VAC
COLD START 45A
PF>0.98/115VAC at full load
80%
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after condition is removed
PROTECTION OVER VOLTAGE
CH1:27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
80
5 (TSW1) Detect on heatsink of Q1,Q2 power transistor)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms
FUNCTION
RC+/RC-:0 ~ 0.8V POWER ON; 4V ~ 10V POWER OFF
REMOTE CONTROL
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
75.9K hrs min.
DIMENSION
280*127*63.5mm (L*W*H)
2.4Kg; 6pcs/14.8Kg/0.89CUFT
PACKING
NOTE
-10 ~ +60
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Peak current can not exceed 60 sec.
6. Isolated CH3 & CH4 maybe series connected or can be used as positive or negative outputs.
7. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-375-24-SPEC 2011-08-19
QP-375-24
375W Quad Output with PFC Function
Mechanical Specification
Case No. 927A
92
63.5
250
+V2 ADJ.
9.5
8.2
I/P
1
2
3
+V3 ADJ.
+V4 ADJ.
6-M3 L=6
99.1
99.1
113
8.2
37
1 6
42.5
30.4
165.1
8-M4 L=6
CN62
127
TB1
1
2
3
4
5
6
7
8
9
10
+V1 ADJ.
O/P
TB2
9.5
Air flow
direction
5
7
LED
Unit:mm
165.1
165.1
240
42.4
31.7
13.9
10.1
280
series
2-M4 L=6
CN62 Pin No. Assignment : JST S6B-XH or equivalent
AC Input Terminal
Pin No. Assignment
Pin No.
1
2
3
Pin No.
Assignment
Mating Housing
Terminal
1
PF(Power good / Fail signal)
GND
2
RS3
JST XHP
JST SXH-001T-P0.6
RS+
or equivalent
or equivalent
4
RC5
RC+
6
DC Output Terminal Pin No. Assignment
Assignment
AC/L
AC/N
FG
Pin No.
1,2
3,4,5
6
7
Assignment
+V1
COM(V1 and V2)
+V2
+V3
Pin No.
8
9
10
Assignment
-V3
+V4
-V4
Block Diagram
fosc : 100KHz
POWER SWITCHING
PWM CONTROL
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
RECTIFIERS
&
P.F.C.
FAN
POWER
SWITCHING
RECTIFIERS
&
FILTER
REGULATOR
MA &
CONTROL
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
MA &
CONTROL
RECTIFIERS
&
FILTER
+V4
-V4
+V3
-V3
+S
+V1
COM
-S
+V2
PF
FG
O.L.P.
O.T.P.
PF
PWM
CONTROL
Derating Curve
O.V.P.
DETECTION
CIRCUIT
+RC
-RC
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
60
50
40
85
95
105
115
125
135
180
230
264
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-375-24-SPEC 2011-08-19
QP-375P
375W Quad Output with PFC Function
Mechanical Specification
series
Unit:mm
250
158
240
5
5
35
LED
1
1
2
6
CN62
3
+V1 ADJ.
113
123
4
5
TB1
TB2
6
+V2 ADJ.
7
1
8
+V3 ADJ.
+V4 ADJ.
2
FS1
T6.3A/250V
3
10
3.2
52
6-
9
CN62 Pin No. Assignment : JST S6B-XH or equivalent
AC Input Terminal
Pin No. Assignment
Pin No.
1
2
3
Assignment
Terminal
Pin No.
Mating Housing
PF(Power good / Fail signal)
1
GND
2
RS3
JST XHP
JST SXH-001T-P0.6
RS+
or equivalent
or equivalent
4
RC5
RC+
6
DC Output Terminal Pin No. Assignment
Assignment
AC/L
AC/N
FG
Pin No.
1,2
3,4,5
6
7
Assignment
+V1
COM(V1 and V2)
+V2
+V3
Pin No.
8
9
10
Assignment
-V3
+V4
-V4
Derating Curve
Output Derating VS Input Voltage
100
100
80CFM
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
60
50
40
85
95
105
115
125
135
180
230
264
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-375P-SPEC 2011-08-19
QP-375
375W Quad Output with PFC Function
series
Control terminal instruction manual
+V1
+V1
COM
COM
PF
+5V
GND
COM
COM
DC 0~15V
COM
+
Load
-
+V2
COM
COM
COM
COM
PF
GND
RSRS+
RCRC+
PF
GND
RSRS+
RCRC+
+V1
+V1
+
Load
-
PF
GND
RSRS+
RCRC+
+
Load
-
+V1
+V1
+V2
+V2
+V3
+V3
+V3
-V3
-V3
-V3
+V4
+V4
+V4
-V4
-V4
-V4
Remote Sensing
Power Fail Signal
Power Fail Signal
PF Signal is the voltage difference between
"GND" and "PF" pin output
Power ON: When V RC+ , RC- =0 ~ 0.8V or Open
Power OFF: When V RC+ , RC- =4 ~ 10V
+V1
+V1
+V1
+V1
COM
COM
COM
-V3
-V4
COM
COM
+V2
+V2
+V3
+V3
-V3
-V3
+V4
+V4
-V4
-V3+(-V4)
+V1
+V1
+V1
+V1
COM
COM
COM
COM
V3,V4 All Positive(+)
+V3
COM
COM
+V2
+V4
-V4
V3 Puls Negative(-)
COM
+V3
COM
COM
V3,V4 All Negative(-)
COM
COM
+V2
+V3+V4
+V3
-V3
-V3
+V4
+V4
-V4
-V4
V3 Plus V4 Positive(+)
File Name:QP-375-SPEC 2011-08-19