SENSORTECHNICS RBAP100DB

RBA Series
Signal conditioned pressure sensors
FEATURES
· 0...10 inch H2O to 0...100 psi,
0...±5 inch H2O to 0...±100 psi,
absolute, gage or differential pressure
· 0.5...4.5 V ratiometric output
· Precision ASIC signal conditioning
· Temperature compensated
· Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage VS
max. 6.50 VDC
Output current
Sink
Source
Lead temperature (2 - 4 sec.)
Temperature ranges
Compensated
Operating
Storage
4.75 V to 5.25 VDC
5 6 7
1
RBA
2
+Vs
2 mA
2 mA
250 °C
0 to +85 °C
-20 to +105 °C
-40 to +125 °C
Vibration
10 g at 20 - 2000 Hz
Shock
RBAP...
RBAH...
100 g for 11 ms
50 g for 11 ms
Caution!
The sensors are not reverse polarity protected.
Incorrect applications of excitation voltage or ground
to the wrong pin can cause electrical failure.
Application of supply voltage above the maximum
can cause electrical failure.
E / 11717 / A
N/C
220 nF
Vout
15 nF
3
8 4
GND
N/C
Note:
Capacitor 220 nF required
between +Vs and GND and
15 nF between Vout and GND.
It is important to place the
capacitors as close to the pins
as possible!
Pins 4, 5, 6, 7 and 8 are internal
device connections and should
not be connected for any reason!
1/6
www.sensortechnics.com
RBA Series
Signal conditioned pressure sensors
PRESSURE RANGES SPECIFICATIONS
(VS = 5.0 VDC, TA = 25°C)
Part number
Pressure range
Burst pressure1
Sensitivity (typ.)
RBAH005DB
0...±5
RBAH010DB
0...±10
RBAH010DU
0...10
3
0.400
RBAP015AU
0...15
30
0.267
RBAP030AU
0...30
RBAP100AU
0...100
150
0.040
RBAP001(G,D)U
0...1
5
4.00
RBAP005(G,D)U
0...5
20
0.80
RBAP015(G,D)U
0...15
RBAP030(G,D)U
0...30
60
0.133
RBAP100(G,D)U
0...100
150
0.040
RBAP001DB
0...±1
5
2.00
RBAP005DB
0...±5
20
0.40
RBAP015DB
0...±15
RBAP030DB
0...±30
60
0.067
RBAP100DB
0...±100
150
0.020
3
"H2O
psi(a)
psi(g)
psi(d)
3
60
30
30
0.400
p si
psi(a)
psi(g)
psi(d)
0.200
V/"H2O
0.133
0.267
V/psi
0.133
Specification notes:
1. If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing
die may fracture.
2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified
pressure. Span is ratiometric to the supply voltage.
3. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature
effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point
within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset
and full scale from nominal values.
4. Delay time between sampling and signal change at the output.
5. The smallest change in the output voltage, given any change in pressure.
6. This is the maximum temperature shift for offset when measured between 0...85 °C relative to the 25 °C reading.
E / 11717 / A
2/6
www.sensortechnics.com
RBA Series
Signal conditioned pressure sensors
PERFORMANCE CHARACTERISTICS
0.5 to 4.5 V ratiometric output (VS = 5.0 VDC, TA = 25°C)
All RBA...U (unidirectional devices)
Characteristics
Zero pressure offset
Min.
Typ.
Max.
RBAH010DU
0.40
0.50
0.60
all others
0.42
0.50
0.58
2
Full scale span (FSS)
V
4.00
Full scale output
3
Total accuracy (0...85°C)
Temperature effect on offset6
RBAH010DU
4.40
4.50
4.60
all others
4.42
4.50
4.58
RBAH010DU
±2.5
all others
±2.0
RBAH010DU
±100
all RBAP...GU, ...DU
±80
Sample rate
100
4
Quantization step
%FSS
mV
Hz
2.73
Response delay
Units
14.11
5
Current consumption
ms
3
mV
6
mA
All RBA...B (bidirectional devices)
Characteristics
Zero pressure offset
Min.
Typ.
Max.
RBAH...DB
2.40
2.50
2.60
all others
2.42
2.50
2.58
2
4.00
Full scale span (FSS)
Output
at max. specified pressure
at min. specified pressure
3
Total accuracy (0...85°C)
Temperature effect on offset6
Sample rate
Response delay
Quantization step
4.40
4.50
4.60
all others
4.42
4.50
4.58
RBAH...DB
0.40
0.50
0.60
all others
0.42
0.50
0.58
RBAH...DB
±2.5
all others
±2.0
RBAH...DB
±100
all others
±80
V
%FSS
mV
Hz
2.73
5
Current consumption
E / 11717 / A
RBAH...DB
100
4
Units
14.11
ms
3
mV
6
mA
3/6
www.sensortechnics.com
RBA Series
Signal conditioned pressure sensors
PHYSICAL DIMENSIONS
Differential (D)
package
1.27 typ
(0.050 typ)
16.89
(0.665)
7.87 typ
(0.310 typ)
13.97
(0.550)
3.63
(0.143)
High pressure port
2.29
(0.090)
3.38
(0.133)
8.13
8.89
(0.350) (0.320)
8.26 typ
(.325 typ)
Low pressure port
0.51 typ
(0.02 typ)
1.78
(0.070)
2.54 typ
(0.100 typ)
16.64 ±0.64
(0.655 ±0.025)
4.5
(0.177)
6.99
(0.275)
Gage (G)
package
3.15
(0.124)
1.27 typ
(0.050 typ)
13.97
(0.550)
16.89
(0.665)
4.9
(0.193)
2 ° typ
1.19 typ
(0.047 typ)
2.29 typ
(0.090 typ)
2.79 typ
(0.11 typ)
8.89
5.08 (0.350)
(0.200)
0.51 typ
(0.02 typ)
16.64 ±0.64
(0.655 ± 0.025)
Absolute (A)
package
4.5
(0.177)
2.54 typ
(0.100 typ)
16.89
(0.665)
8.46
(0.333)
1.27 typ
(0.050 typ)
13.97
(0.550)
2.29 typ
(0.090 typ)
8.0 typ
(0.315 typ)
8.89
(0.350)
16.64 ±0.64
(0.655 ±0.025)
E / 11717 / A
4.5
(0.177)
0.51 typ
(0.02 typ)
2.54 typ
(0.100 typ)
third angle projection
dimensions in mm (inches)
4/6
www.sensortechnics.com
RBA Series
Signal conditioned pressure sensors
ELECTRICAL CONNECTIONS
RBA...DU, RBA...DB
RBA...GU
Vs (pin 1)
identifier
Vs (pin 1)
identifier
+Vs
Vout
GND
N/C
N/C
N/C
N/C
N/C
RBA...AU
N/C
N/C
N/C
N/C
+Vs
Vout
GND
N/C
Vs (pin 1)
identifier
N/C
N/C
N/C
N/C
Note:
Pins 4, 5, 6, 7 and 8 are internal device
connections and should not be connected
for any reason!
+Vs
Vout
GND
N/C
TOTAL ACCURACY (-20 to +105°C)
Total accuracy (%FSS)
For all RBAP... devices
3.0
2.0
1.0
0
-1.0
-2.0
-3.0
-20
0
20
40
60
85
105
Temperature (°C)
E / 11717 / A
5/6
www.sensortechnics.com
RBA Series
Signal conditioned pressure sensors
ORDERING INFORMATION - AVAILABLE LISTINGS
Note:
Preferred listings are highlighted in grey
Pressure range
Absolute (A)
Gage (G)
Differential (D)
Unidirectional (U)
0...10 inch H2O
RBAH010DU
0...1 psi
RBAP001GU
RBAP001DU
0...5 psi
RBAP005GU
RBAP005DU
0...15 psi
RBAP015AU
RBAP015GU
RBAP015DU
0...30 psi
RBAP030AU
RBAP030GU
RBAP030DU
0...100 psi
RBAP100AU
RBAP100GU
RBAP100DU
Bidirectional (B)
0...±5 inch H2O
RBAH005DB
0...±10 inch H2O
RBAH010DB
0...±1 psi
RBAP001DB
0...±5 psi
RBAP005DB
0...±15 psi
RBAP015DB
0...±30 psi
RBAP030DB
0...±100 psi
RBAP100DB
Sensortechnics PRO services:
· Extended guarantee period of 2 years
· Improved performance characteristics
· Custom product modifications and adaptations even for small quantities
· Advanced logistics models for supply inventory and short delivery times
· Technical support through application engineers on the phone or at your site
· Fastest possible technical response for design and QA engineers
... plus other services on request
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11717 / A
6/6
www.sensortechnics.com