SENSORTECHNICS RLOH030D

RLO Series
.
Precision compensated low pressure sensors
FEATURES
· Ranges from 1 to 30 inch H2O
gage or differential
· Precision temperature compensated
· Calibrated offset and span
· Extremely low position sensitivity
· Excellent long term stability
· Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.
The media wetted materials are:
- silicon
- glass filled nylon
- silicone
- ceramic (Al2O3)
- gold
ELECTRICAL CONNECTION
EQUIVALENT CIRCUIT
Top view
+Vs
2
1 2 3 4 5 6
-Vout
+Vout
5
3
Port 1
Port 2
4
-Vs
E / 11713 / A
Pin
Pin
Pin
Pin
Pin
Pin
1:
2:
3:
4:
5:
6:
N/C
+Vs
+Vout
-Vs
-Vout
N/C
Note:
The polarity indicated is for pressure applied to port 2
1/5
www.sensortechnics.com
RLO Series
Precision compensated low pressure sensors
SPECIFICATIONS
Maximum ratings
Environmental specifications
Supply voltage VS
Common-mode pressure
Lead temperature (soldering 5 seconds)
0 to 16 V
50 psig
315 °C
Temperature range
Compensated
Operating
Storage
Humidity limits (non-condensing)
0 to 50°C
-25 to 85°C
-40 to 125°C
0 to 95 %RH
PRESSURE SENSOR CHARACTERISTICS
Part no.
Operating pressure
Max. over pressure1
RLOH001D
1 "H2O
5 p si
RLOH005D
5 "H2O
5 p si
RLOH010D
10 "H2O
5 p si
RLOH020D
20 "H2O
5 p si
RLOH030D
30 "H2O
5 p si
PERFORMANCE CHARACTERISTICS
(VS = 12 V, TA = 25 °C, common-mode pressure = 0 psig, pressure applied to port 2)
RLOH001D
Characteristics
Zero pressure offset
Full scale span (FSS)2
Min.
Typ.
Max.
-0.5
0
+0.5
9
10
11
Combined non-linearity and hysteresis3
4
Temperature effects (0 to 50°C)
±0.25
Span
±200
Offset
±250
Offset warm-up shift5
±100
Offset position sensitivity (±1 g)
±50
Input resistance
4.5
Output resistance
1.5
Common mode voltage6
E / 11713 / A
6
Unit
mV
%FSS
µV
kΩ
V
2/5
www.sensortechnics.com
RLO Series
Precision compensated low pressure sensors
PERFORMANCE CHARACTERISTICS (cont.)
(VS = 12 V, TA = 25 °C, common-mode pressure = 0 psig, pressure applied to port 2)
RLOH005D
Characteristics
Zero pressure offset
Full scale span (FSS)2
Min.
Typ.
Max.
-0.5
0
+0.5
19
20
21
Combined non-linearity and hysteresis3
4
Temperature effects (0 to 50°C)
±0.25
Span
±200
Offset
±150
5
Offset warm-up shift
±50
Offset position sensitivity (±1 g)
±10
Input resistance
10
Output resistance
1.5
Common mode voltage6
Unit
mV
%FSS
µV
kΩ
6
V
RLOH010D
Characteristics
Zero pressure offset
Full scale span (FSS)2
Min.
Typ.
Max.
-0.5
0
+0.5
19
20
21
Combined non-linearity and hysteresis3
Temperature effects (0 to 50°C)4
5
±0.25
Span
±200
Offset
±150
Offset warm-up shift
±50
Offset position sensitivity (±1 g)
±10
Input resistance
13
Output resistance
1.5
Common mode voltage6
E / 11713 / A
6
Unit
mV
%FSS
µV
kΩ
V
3/5
www.sensortechnics.com
RLO Series
Precision compensated low pressure sensors
PERFORMANCE CHARACTERISTICS (cont.)
(VS = 12 V, TA = 25 °C, common-mode pressure = 0 psig, pressure applied to port 2)
RLOH020D
Characteristics
Zero pressure offset
Full scale span (FSS)2
Min.
Typ.
Max.
-0.5
0
+0.5
19
20
21
Combined non-linearity and hysteresis3
4
Temperature effects (0 to 50°C)
±0.25
Span
±200
Offset
±150
5
Offset warm-up shift
±50
Offset position sensitivity (±1 g)
±5
Input resistance
10
Output resistance
2
Common mode voltage6
6
Unit
mV
%FSS
µV
kΩ
V
RLOH030D
Characteristics
Zero pressure offset
Full scale span (FSS)2
Min.
Typ.
Max.
-0.5
0
+0.5
19
20
21
Combined non-linearity and hysteresis3
Temperature effects (0 to 50°C)4
5
±0.25
Span
±200
Offset
±150
Offset warm-up shift
±50
Offset position sensitivity (±1 g)
±5
Input resistance
12
Output resistance
1.5
Common mode voltage6
Unit
mV
%FSS
6
µV
kΩ
V
Notes
1
The maximum over pressure may be applied without causing durable shifts of the electrical parameters of the sensing element.
2
Full scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
3
Non-linearity refers to the Best Straight Line fit measured for offset pressure, full-scale pressure and ½ full-scale pressure.
4
Shift is relative to 25°C.
5
Shift within the first hour of excitation applied to the sensor.
6
This is the common mode voltage of the output arms (pin 3 and 5) for Vs= 12 V
E / 11713 / A
4/5
www.sensortechnics.com
RLO Series
Precision compensated low pressure sensors
OUTLINE DRAWING
6 5 4 3 2 1
1 2 3 4 5 6
Port 1
7.62
(0.3)
2.54
(0.10)
0.51
(0.02)
0.25
(0.01)
DIA 3.30
(0.13)
DIA 4.83
(0.19)
DIA 2.03
(0.08)
5.33
(0.21)
DIA 3.56
(0.14)
10.67
(0.42)
10.67
(0.42)
27.43
(1.08)
Port 2
20.32
(0.80)
12.19
(0.48)
13.97
(0.55)
21,59
(0.85)
27.94
(1.10)
mass: approx. 10 g
third angle projection
dimensions in mm (inches)
ORDERING INFORMATION - AVAILABLE LISTINGS
Note:
Preferred listings are highlighted in grey
Pressure range
Gage/differential devices
1 "H2O
RLOH001D
5 "H2O
RLOH005D
10 "H2O
RLOH010D
20 "H2O
RLOH020D
30 "H2O
RLOH030D
Sensortechnics PRO services:
· Extended guarantee period of 2 years
· Improved performance characteristics
· Custom product modifications and adaptations even for small quantities
· Advanced logistics models for supply inventory and short delivery times
· Technical support through application engineers on the phone or at your site
· Fastest possible technical response for design and QA engineers
... plus other services on request
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11713 / A
5/5
www.sensortechnics.com