RPS-60 60W Single Output Medical Type series Features : 4" 2" miniature size Universal AC input/Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Cooling by free air convection ANSI/AAMI ES60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved No load power consumption<0.75W Fixed switch frequency at 100KHz 3 years warranty SPECIFICATION MODEL RPS-60-3.3 RPS-60-5 RPS-60-12 RPS-60-15 RPS-60-24 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 10A 10A 5A 4A 2.5A 1.25A CURRENT RANGE 0 ~ 11A 0 ~ 11A 0 ~ 5.5A 0 ~ 4.4A 0 ~ 2.75A 0 ~ 1.375A RATED POWER 33W 50W 60W 60W 60W 60W 55W 66W 66W 66W 66W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 150mVp-p 240mVp-p 300mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 2.0% 11.4 ~ 13.2V 2.0% 13.5 ~ 16.5V 2.0% 22.8 ~ 27.6V 1.0% 45.6 ~ 52.8V 1.0% PEAK LOAD(10sec.) OUTPUT Note.4 36.3W VOLTAGE TOLERANCE Note.3 INPUT 3.1 ~ 3.6V 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.8A/115VAC COLD START 60A/230VAC LEAKAGE CURRENT For earth <200uA / 264VAC, For patient <100uA/264VAC OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. 500ms, 30ms/115VAC at full load 13ms/115VAC at full load 127 ~ 370VDC 79% 83% 84% 86% 28.4 ~ 32.4V 55.2 ~ 64.8V 30A/115VAC 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 5V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +70 85% 1 A/230VAC (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION 20 ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 5) EMC EMISSION UL60950-1, TUV EN60950-1, ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved OTHERS -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25 / 70% RH Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A MTBF 353.6Khrs min. MIL-HDBK-217F (25 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT DIMENSION PACKING NOTE RPS-60-48 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Heat Sink HS1,HS2 can not be shorted. File Name:RPS-60-SPEC 2012-01-09 RPS-60 60W Single Output Medical Type Mechanical Specification series Unit:mm 101.6 3.175 95.25 50.8 44.45 FS1 3.175 HS2 AC FUSE T2.5/250V 3 2 1 CN1 SVR1 1 2 3 4 FS2 AC FUSE T2.5/250V CN2 HS1 3 max. 29 4- 3.3 DC Output Connector (CN2) : JST B4P-VH or equivalent AC Input Connector (CN1) : JST B3P-VH or equivalent Assignment AC/N No Pin AC/L Pin No. 1 2 3 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1,2 3,4 Assignment +V -V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent HS1,HS2 can not be shorted Block Diagram fosc : 100KHz RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Output Derating VS Input Voltage Output Derating 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 65 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RPS-60-SPEC 2012-01-09