RT-3 UNIT RELAY SLIM, SPACE-SAVING RELAY TERMINAL FOR 4-POINT OUTPUT (PA Relay type) FEATURES • 33 mm 1.299 inchwide space-saving type, with four independent points on a base measuring 33 × 67 mm 1.299×2.638 inch. Contributes to control panel and device downsizing. • Equipped with PA relays with highsensitivity twin contacts and Au-caldding. Equipped with 5 mm .197 inch wide PA relays. The PA relays feature high sensitivity (12 V type: 120 mW, 24 V type: 180 mW) and twin contacts with Au-cladding, which combine to ensure high reliability even with minute loads. • Can be used mounted on a DIN rail or mounted directly (by screw). • Equipped with an LED display to allow easy confirmation of operation. • Incorporates a surge absorber. Incorporates an absorber circuit for coil surges. This protects the circuitry of the controller and prevents operation errors. • Relay installation and removal can be easily accomplished with the removal key accessory. • Includes a cover as standard equipment for increased safety. TYPES Packing quantity Type Rated input voltage Part No. PA relay 12 V DC 24 V DC RT3S-12V RT3S-24V Inner carton Outer carton 10 pcs. 100 pcs. Notes: 1. Cannot be equipped with Power PhotoMOS standard type relays. However, equipping with voltage sensitive type of Power PhotoMOS relays (AQZ❍❍❍D) is possible. 2. 5 V DC units are also available. Please consult us. RATINGS 1. Input ratings (per PA relay) Part No. Rated input voltage RT3S-12V RT3S-24V 12 V DC 24 V DC Input current (at rated input voltage, 20°C 68°F) (approx.) 11.5 mA (Relay 10 mA + LED 1.5 mA) 10.5 mA (Relay 7.5 mA + LED 3 mA) Allowable variation of rated input voltage (–20 to +55°C –4 to +131°F) 12 V DC ± 10% 24 V DC ± 10% 2. Relay coil specifications (per PA relay) (ref. value) Relay part No. Rated coil voltage Pick-up voltage (at 20°C 68°F) (Initial) Drop-out voltage (at 20°C 68°F) (Initial) PA1a-12V PA1a-24V 12 V DC 24 V DC less than 70% of nominal voltage more than 5% of nominal voltage 10% Coil resistance (±10%) (at 20°C 68°F) 1,200 Ω ±10% 3,200 Ω ±10% Rated comsumption power 3. Output ratings (per PA relay) Specification Contact rating Expected life (Min. operations) Item Rated control capacity (resistive load) Maximum allowable contact power (resistive load) Maximum allowable contact voltage Maximum allowable contact current Minimum load (ref. value) Electrical (resistive load) Mechanical (at 180 cpm) 12 Performance 2 A 250 V AC, 2 A 30 V DC 500 VA (AC), 60 W (DC) 250 V AC, 30 V DC 2A 100 mV 100 µA 105: 2 A 250V AC 105: 2 A 30V DC 3 × 105: 1 A 250V AC 3 × 105: 1 A 30V DC 2 × 107 120 mW 180 mA RT-3 PERFORMANCE Item Between input and output Between different terminals (between relays, both ways) Breakdown voltage Performance 2,000 Vrms for 1 min. 1,500 Vrms for 1 min. Min. 100 MΩ (Using 500 V DC megger) 10 to 55 Hz at double amplitude 1 mm .039 inch 10 to 55 Hz at double amplitude 1 mm .039 inch Min. 196 m/s2 {20G} Min. 98 m/s2 {10G} –20°C to +55°C –4°F to +131°F 35% to 85% R.H. (Not condensing) –30°C to +80°C –22°F to +176°F (Not freezing and condensing) 0.3 to 0.5 Nm {3 to 5 kgf·cm} Diode (1 A, 400 V) 1.5 A, inverse voltage 40 V Approx. 100 g 3.53 oz Insulation resistance destructive functional destructive Vibration resistance Shock resistance functional Ambient temperature Ambient humidity Storage temperature Terminal screw fasten torque Coil surge absorber Cross connection protecting diode Weight Notes: 1. The value of breakdown voltage and insulation resistance is the initial one. 2. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition 3. Below 0°C 32°F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition. DATA 1. Maximum value for switching capacity per relay (output) 100 Resistive AC load No. of operations, ×104 Contact current, A 4.0 3.0 2. Life curve per relay (output) 2.0 1.0 0.5 0.4 0.3 Resistive DC load 50 30 20 125 V AC resistive load 30 V DC resistive load 250 V AC resistive load 10 0.2 20 30 0.5 50 100 200 300 Contact voltage, V 1.0 2.0 3.0 Switching current, A DIMENSIONS mm inch Internal schematic 7.62 .300 Input terminal portion 33±0.6 1.299±.024 6.2 .244 16-M3 .118 terminal screw Input side 8.4 .331 13+ 14+ 15+ 16+ 9– 10– 11– 12– LED1 LED2 LED3 LED4 5 6 7 8 1 2 3 4 R2.1 .083 2-M4 .157 screw mounting position 67±1 2.638±.039 7.4 .291 4.2+0.3 −0.1 .165+.012 −.004 R3.7 .146 Output side Output terminal portion With cover removed 4 .157 5.5±0.6 .217±.024 13.8 .543 32±1 1.260±.039 Note: Cannot be equipped with Power PhotoMOS standard type relays. However, equipping with voltage sensitive type of Power PhotoMOS relays (AQZ❍❍❍D) is possible. Panel cutout ±0.6 30 1.181±.024 2-4.3 dia. or M4 2-.169 dia. or M.157 30±0.1 1.181±.004 General tolerance ±0.3 ±.012 13 RT-3 TERMINAL BLOCK ACCESSORIES We recommend using wire-pressed terminals for connection to the terminal portion. • Applicable electrical wire 0.25 to 1.65 mm2 .01 to .065 inch mm inch • Applicable wire-pressed terminals Short circuit plate Use when you want to bridge terminals. For the external dimensions, see the Options section for —4-point Unit Relay (Power PhotoMOS Relay Type).— < With insulator > < Without insulator > AY3802 AY3803 3 dia. min. .118 dia. min. 5.6 max. .220 max. 3 min. .118 min. 5.6 max. .220 max. 4 4.5 min. .157 .177 min. 4 4.5 min. .157 .117 min. CAUTIONS FOR USE 1. Operating environment 1) Keep the product as far way as possible from power cables, high tension equipment, power equipment, equipment with transmitting devices such as amateur radios, or equipment which generates a large switching surge. 2) The main unit is made of resin; therefore, do not use it in areas where it may come in contact with (or be exposed to) organic solvents such as benzine, thinner, and alcohol, or strong alkaline substances such as ammonia and caustic soda. 3) Do not use the product in areas where it may be exposed to flammable gases, corrosive gases, excessive dust, or moisture, or areas where it may be subjected to strong vibration or shock. 2. Dropping If a unit is dropped be sure to check its external appearance and characteristics before using it. 3. Installing and removing the module 1) Firmly insert the module into the socket with the terminals going in the direction of the blade receptacles. 2) The module can be easily removed using the removal key. (1) Insert the removal key into the socket slots. (2) Pull the removal key up to remove the module. 3 Remove the unit from the DIN rail. 2 Move the screwdriver in the direction of the arrows, and pull out the lever. 1 Insert the tip of the flat head screwdriver into the slot in the DIN rail locking lever. 4. Wiring and circuit configuration 1) Perform wiring according to the internal schematic. Take care not to make any mistakes. 2) We recommend the use of wirepressed terminals for connection to the terminal portion. 3) When the load is inductive, we recommend adding a diode or surge absorber at both ends of the load. 5. Installation 1) Perform mounting hole cutout according to the panel cutout drawings. 2) When installing the unit on a DIN rail, use the DIN rail locking lever on the side of the unit. Installation is accomplished by simply fitting the unit onto the rail and pressing gently. 1 First push in the DIN rail locking lever. DIN rail locking lever DIN rail 3 Press the unit onto the DIN rail. 2 Hook the holders on the unit over the DIN rail. 14 3) To remove the unit from the DIN rail, use a flat head screwdriver to pull out the DIN rail locking lever. 6. Transporting and storage 1) If the product is subjected to extreme vibration while being transported, the relays may become detached, the lead may become bent, and the unit may become damaged. Handle the inner and outer boxes with care. 2) If the product is stored in an extremely adverse environment, visible defects and deterioration of performance characteristics may result. We recommend the following storage conditions. • Temperature: 5 to 30°C 41 to 86°F • Humidity: Max. 60% R.H. • Environment: No hazardous substances such as sulfurous acid gases and little dust. 7. When equipped with Power PhotoMOS relay voltage drive type Since the Power PhotoMOS relay voltage drive type does not require the currentcontrolling resistance on the input side, it can be used together with PA relays on 4point unit relays (PA relay types) or RT-2 relay terminals. When connecting Power PhotoMOS relay voltage drive types, since it will be a close connection, it will be necessary to be careful of load currents. Be sure to refer to the information given regarding load currents and ambient temperature characteristics in the precautions given for use of RT-2 relay terminals.