ETC RT2S-MC-OD16-24

RT-2 RELAY
TERMINAL
PARM-SIZED,
16-CHANNEL
RELAY TERMINALS
FEATURES
• Compact, space-saving design:
The Relay Terminal with 16 I/O channels
measures only (W)116 × (D)52 × (H)37
mm (W)4.57×(D)2.047× (H)1.457 inch.
The compact design contributes to
equipment downsizing.
• Incorporates PA Relays with highsensitivity twin contacts and Au-cladding:
The Relay Terminal incorporates 5 mm
.197 inch wide PA relays. The PA relay
features high sensitivity (12 V type = 120
mW, 24 V type = 180 mW) and twin contacts with Au-cladding, which combine to
ensure high reliability under low-level
loads.
• Available in input and output devices
• Available in Pressure connector connect type and wire-direct connect
type:
Pressure connector connect type has a
single common for four I/O channels.
The Wire-direct connect type has a single common for each I/O channel.
• Incorporates a surge absorber:
The RT-2 Series incorporates a surge
absorber to protect the programmable
controller internal electronics from inductor turn-off surges.
Pressure connector connect type
Wire-direct connect type
• Equipped with LED indicator lights:
LED indicators allow the user to identify
the relay status at a glance.
• Comes with AXM connector (long lever version):
The RT-2 Series comes with the AXM
connector (complying with the MIL standard) for single connections. Cable designed for use with AXM connectors are
also available.
• Ease of mounting on DIN rails:
The DIN rail mounting hook of relay terminal is provided with a release/retention mechanism to ease mounting and
removal.
• Available with a wide variety of cables:
A wide variety of assembled cables offers compatibility with our programmable
controllers, and wire-pressed terminal
cables provide compatibility with other
controllers.
ORDERING INFORMATION
Ex. RT2S
M
C
ID
16
12V
Installation type
Termination type
I/O type
No. of I/O channels
Rated voltage
Blank: DIN rail mounting type
M:
Direct mounting type
Blank: Pressure connector connect type
C:
Wire-direct connect type
ID: Input device (DC)
OD: Output device (DC)
16: 16 channels
12 V: 12 V DC
24 V: 24 V DC
Note: Please consult us regarding minus common types for input.
15
RT-2
TYPES
1. DIN Rail Mounting Type
1) Pressure connector connect type
I/O type
Rated voltage
12 V DC
24 V DC
12 V DC
24 V DC
Input device
Output device
Part No.
Packing quantity
Inner carton
Outer carton
1 pc.
10 pcs.
RT2S-ID16-12V
RT2S-ID16-24V
RT2S-OD16-12V
RT2S-OD16-24V
2) Wire-direct connect type
I/O type
Rated voltage
Part No.
12 V DC
24 V DC
12 V DC
24 V DC
RT2S-C-ID16-12V
RT2S-C-ID16-24V
RT2S-C-OD16-12V
RT2S-C-OD16-24V
Input device
Output device
Packing quantity
Inner carton
Outer carton
1 pc.
10 pcs.
2. Direct Mounting Type
1) Pressure connector connect type
I/O type
Rated voltage
Part No.
12 V DC
24 V DC
12 V DC
24 V DC
RT2S-M-ID16-12V
RT2S-M-ID16-24V
RT2S-M-OD16-12V
RT2S-M-OD16-24V
Rated voltage
Part No.
12 V DC
24 V DC
12 V DC
24 V DC
RT2S-MC-ID16-12V
RT2S-MC-ID16-24V
RT2S-MC-OD16-12V
RT2S-MC-OD16-24V
Type
Rated voltage
Part No.
PA relay
12 V DC
24 V DC
PA1a-12V
PA1a-24V
Input device
Output device
Packing quantity
Inner carton
Outer carton
1 pc.
10 pcs.
2) Wire-direct connect type
I/O type
Input device
Output device
Packing quantity
Inner carton
Outer carton
1 pc.
10 pcs.
3. Interface Relay
Packing quantity
Inner carton
Outer carton
25 pcs.
1,000 pcs.
RATINGS
1. Relay coil specifications (per PA relay)
Rated coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Rated exciting
current
(±10%)
Coil resistance
(±10%)
(at 20°C 68°F)
Rated power
consumption
12 V DC
24 V DC
less than 70%
of nominal voltage
more than 5%
of nominal voltage
10 mA
7.5 mA
1,200 Ω
3,200 Ω
120 mW
180 mW
Max. continuous
voltage
(at 55°C 131°F)
V DC
14.4
28.8
Note: The LED draws a drive current of approximately 3 mA per channel. When calculating the supply capacity required, include the total current consumed by the LEDs.
2. Contacts (per PA relay)
Specification
Contact rating
Expected life
(minimum operations)
Item
Rated control capacity (resistive load)
Maximum allowable contact power
(resistive load)
Maximum allowable contact voltage
Maximum allowable contact current
Minimum load (ref. value)
Electrical (resistive load)
Mechanical (at 180 cpm)
16
Performance
2 A 250 V AC, 2 A 30 V DC
500 VA (AC), 60 W (DC)
250 V AC, 30 V DC
2A
100 mV 100 µA
105: 2 A 250V AC 105: 2 A 30V DC
3 × 105: 1 A 250V AC
3 × 105: 1 A 30V DC
2 × 107
RT-2
PERFORMANCE
Item
Input
100 MΩ
(excluding battery at 500 V DC megger)
100 MΩ (at 500 V DC megger)
Output
100 MΩ
(excluding battery at 500 V DC megger)
100 MΩ (at 500 V DC megger)
—
100 MΩ (at 500 V DC megger)
2,000 Vrms for 1 min. (excluding battery)
1,500 Vrms for 1 min.
2,000 Vrms for 1 min. (excluding battery)
1,500 Vrms for 1 min.
—
1,000 Vrms for 1 min.
10 to 55 Hz at double amplitude
1 mm .039 inch
10 to 55 Hz at double amplitude
1 mm .039 inch
Min. 196 m/s2 {20G}
10 to 55 Hz at double amplitude
1 mm .039 inch
10 to 55 Hz at double amplitude
1 mm .039 inch
Between connector terminals
Initial
Insulation
resistance
(Min.)
Initial
breakdown
voltage
(Min.)
Between unlike poles on the terminals
Between like poles on the terminals
(for output)
Between connector terminals
Between unlike poles on the terminals
Between like poles on the terminals
(for output)
Destructive
Vibration resistance
Functional
Destructive
Shock resistance
Min. 196 m/s2 {20G)
Min. 98 m/s2 {10G}
Min. 98 m/s2 {10G)
Min. 1,000 V*
Min. 1,000 V*
Min. 1,000 V*
Min. 1,500 V*
0°C to +55°C +32°F to +131°F
0°C to +55°C +32°F to +131°F
35% to 85% R.H. (Not condensing)
35% to 85% R.H. (Not condensing)
–30°C to +80°C –22°F to +176°F
–30°C to +80°C –22°F to +176°F
(Not freezing and condensing)
(Not freezing and condensing)
0.3 to 0.5 N·m (3 to 5 kgf·cm) for pressure connector connect type;
0.2 to 0.4 N·m (2 to 4 kgf·cm) for wire-direct connect type
Diode (1 A, 400 V)
Diode (1 A, 400 V)
1A, inverse voltage 40 V
1.5 A, inverse voltage 40 V
Approx. 200 g 7.1 oz
Approx. 200 g 7.1 oz
Functional
Superimposed power noise
Superimposed I/O noise
Ambient temperature
Ambient humidity
Storage temperature
Terminal screw fasten torque
Coil surge absorber
Cross connection protecting diode
Weight
*According to in-house measurement.
Notes: 1. The value of breakdown voltage and insulation resistance is the initial one.
2. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This
may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition
3. Below 0°C 32°F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition.
TERMINAL BLOCK
1. Pressure connector connect type
• Applicable electrical wire
0.25 to 1.65 mm2 .01 to .065 inch
• Applicable wire-pressed terminals
2. Wire-direct connect type
Strip the wire ends as follows:
mm inch
Stripping length
8 to 10 mm
.315 to .394 inch
Recommended wire
0.128 to 1.318 mm .005 to 0.52 inch
0.4 to 1.3 mm dia. .016 to .051 inch
3 dia. min.
.118 dia. min.
5.6 max.
.220 max. 3 min.
.118 min.
5.6 max.
.220 max.
4
4.5 min.
.157 .177 min.
4
4.5 min.
.157 .117 min.
DATA
1. Maximum value for switching capacity per PA
relay (output)
100
Resistive AC load
2.0
1.0
0.5
0.4
0.3
Resistive DC load
No. of operations, ×104
Contact current, A
4.0
3.0
2. Life curve per PA relay (output)
50
30
20
125 V AC resistive load
30 V DC resistive load
250 V AC resistive load
10
0.2
20 30
50 100
200 300
Contact voltage, V
0.5
1.0
2.0 3.0
Switching current, A
17
RT-2
DIMENSIONS
mm inch
Dimensions are common to both input and output module.
1. DIN rail mounting
Pressure connector connect type
0
1
2
3
4
5
6
7
36.8±0.6
1.449±.024
8
9
A
B
C
D
E
F
52±1
2.047±.039
52±1
2.047±.039
POWER
7.62±0.3
.300±.012
116±1 4.567±.039
6.2±0.3
.244±.012
22-M3 .118 terminal screw
36.8±0.6
1.449±.024
Wire-direct connect type
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
52±1
2.047±.039
POWER
5.08±0.3
.200±.012
116±1 4.567±.039
+ 0+ 1+ 2+ 3+ 4+ 5+ 6+ 7+ 8+ 9+ A+ B+ C+ D+ E+ F+
- 0- 1- 2- 3- 4- 5- 6- 7- 8- 9- A- B- C- D- E- F-
2. Direct mounting
Pressure connector connect type
133±1 5.236±.039
125±0.5 4.921±.020
(M4 .157 screw mounting pitch)
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
36.8±0.6
1.449±.024
2-M4 .157 screw
mounting position
52±1
2.047±.039
POWER
6.2±0.3
.244±.012
7.62±0.3
.300±.012
22-M3 .118 termibnal screw
116±1 4.567±.039
36.8±0.6
1.449±.024
18
5.2±0.3
.205±.012
RT-2
Wire-direct connect type
mm inch
133±1 5.236±.039
125±0.5 4.921±.020
(M4 .157 screw mounting pitch)
0
1
2
3
4
5
6
7
2-M4 .157 screw
mounting position
8
9
A
B
C
D
E
F
52±1
2.047±.039
POWER
5.08±0.3
.200±.012
116±1 4.567±.039
+ 0+ 1+ 2+ 3+ 4+ 5+ 6+ 7+ 8+ 9+ A+ B+ C+ D+ E+ F+
- 0- 1- 2- 3- 4- 5- 6- 7- 8- 9- A- B- C- D- E- F-
36.8±0.6
1.449±.024
SCHEMATIC (common to both DIN rail mounting and direct mounting)
1. Pressure connector connect type (4 commons)
Input module
Connector pin
18
17
16
15
14
13
12
11
8
7
6
2
12
5
3
13
4
4
14
3
5
15
2
6
16
7
17
8
18
9
19
10
20
LEDF
LEDE
LEDD
LEDC
LEDB
LEDA
LED9
LED8
LED7
LED6
LED5
LED4
LED3
9
LED2
19
LED1
1
LED0
Connector pin layout
(TOP VIEW)
1
11
20
10
POWER
0-
2-
COM+
VCC
GND
1-
3-
4-
5-
76-
8COM+
A9-
COM+
B-
C-
F-
DE-
COM+
Terminal portion
Note: Above terminal number is not marked on the terminal itself.
Wiring should be done according to the O mark.
19
RT-2
Output module
Connector pin
20
10
18
17
16
15
14
13
12
11
8
Connector pin layout
(TOP VIEW)
1
11
7
6
2
12
5
3
13
4
4
14
3
5
15
6
16
LEDF
LEDE
LEDD
LEDC
LEDB
LEDA
LED9
LED8
LED7
LED6
LED5
20
LED4
10
9
LED3
19
LED2
18
9
LED1
17
8
1
19
LED0
7
2
POWER
VCC
GND
0+
COM-
2+
1+
3+
5+
4+
7+
6+
8+
COM-
A+
9+
D+
COMB+
C+
F+
COM-
E+
Terminal portion
Note: Above terminal number is not marked on the terminal itself.
Wiring should be done according to the O mark.
2. Wire-direct connect type (Individual common)
Input module
Connector pin
18
17
16
15
14
13
12
11
8
7
6
2
12
5
3
13
4
4
14
3
5
15
2
6
16
LEDF
LEDE
LEDD
LEDC
LEDB
LEDA
LED9
LED8
LED7
LED6
20
LED5
10
9
LED4
19
LED3
18
9
LED2
17
8
19
LED1
7
1
LED0
Connector pin layout
(TOP VIEW)
1
11
20
10
POWER
VCC
0+
GND
1+
0-
2+
1-
3+
2-
Terminal portion
Note: Above terminal number is not marked on the terminal itself.
Wiring should be done according to the O mark.
20
4+
3-
5+
4-
6+
5-
7+
6-
8+
7-
9+
8-
A+
9-
B+
A-
C+
B-
D+
C-
E+
D-
F+
E-
F-
RT-2
Output module
Connector pin
20
10
18
17
16
15
14
13
12
11
8
7
6
2
12
5
3
13
4
4
14
3
5
15
6
16
LEDF
LEDE
LEDD
LEDC
LEDB
LEDA
LED9
LED8
LED7
LED6
20
LED5
10
9
LED4
19
LED3
18
9
LED2
17
8
1
19
LED1
7
2
LED0
Connector pin layout
(TOP VIEW)
1
11
POWER
VCC
GND
0+
1+
0-
2+
1-
3+
2-
4+
3-
5+
4-
6+
5-
7+
6-
8+
7-
9+
8-
A+
9-
B+
A-
C+
B-
D+
C-
E+
D-
F+
E-
F-
Terminal portion
Note: Above terminal number is not marked on the terminal itself.
Wiring should be done according to the O mark.
CAUTIONS FOR USE
1) DC type, 12 V input
3) AC/DC type, 12 V input
AQZ102D
AQZ105D
1
2
Load current, A
Load current, A
2
AQZ202D
AQZ205D
1
AQZ107D
AQZ207D
AQZ104D
–20 –10
–4 14
0
AQZ204D
10 20 30 40 50 60
50 68 86 104 122 140
Ambient temperature, °C °F
2) DC type, 24 V input
–20 –10
–4 14
0
10 20 30 40 50 60
50 68 86 104 122 140
Ambient temperature, °C °F
4) AC/DC type, 24 V input
2
2
AQZ105D
1
Load current, A
AQZ102D
Load current, A
1. When equipped with Power PhotoMOS relay voltage sensitive type
Since the Power PhotoMOS relay voltage
sensitive type does not require the current-controlling resistance on the input
side, it can be used together with PA relays on 4-point unit relays (PA relay types)
or RT-2 relay terminals.
When connecting Power PhotoMOS relay
voltage sensitive types to 4-point relays
(PA relay types) or RT-2 relay terminals, it
will be necessary to be careful of load currents (since it will be a close connection).
Be sure to use within the range given in
the load currents and ambient temperature characteristics graphs given below.
• Power PhotoMOS relay (voltage sensitive type) load currents and ambient
temperature characteristics
When equipped on 4-point unit relay (PA
relay type) or RT-2 relay terminal.
AQZ202D
1
AQZ205D
AQZ107D
AQZ207D
AQZ104D
–20 –10
–4 14
0
10 20 30 40 50 60
50 68 86 104 122 140
Ambient temperature, °C °F
AQZ204D
–20 –10
–4 14
0
10 20 30 40 50 60
50 68 86 104 122 140
Ambient temperature, °C °F
21
RT-2
2. Operating environment
1) Use the product at ambient operating
temperature between 0°C and 55°C 32°F
and 131°F. (When installing in the control
panel, take heat release into due consideration. Installing of the product at 90 degrees to the control panel is
recommended. When installing the product horizontally or placing it on a heating
unit, use a cooking fan.)
2) Keep the supply voltage within the
range of 90% V to 110% V of the rated
voltage.
3) Keep the product as far as possible
from power cables, high tension equipment, power equipment, equipment with
transmitting devices such as amateur radios, or equipment which generates a
large switching surge.
4) The main unit is made of resin; therefore, do not use it in areas where it may
come in contact with (or be exposed to)
organic solvents such as benzine, thinner,
and alcohol or strong alkaline substances
such as ammonia and caustic soda.
5) Do not use the product in areas where
it may be exposed to flammable gases,
corrosive gases, excessive dust, or moisture, or areas where it may be subjected
to strong vibration or shock.
3. Dropping
If a unit is dropped be sure to check its external appearance and characteristics before using it.
4. Installing and removing the module
1) Firmly insert the module into the socket
with the terminals going in the direction of
the blade receptacles.
2) The module can be easily removed using the removal key.
(1) Insert the removal key into the socket
slots.
22
(2) Pull the removal key up to remove the
module.
6. Installation
1) Perform mounting hole cutout according to the panel cutout drawings.
2) When installing the unit on a DIN rail,
use the DIN rail locking lever on the side
of the unit. Installation is accomplished by
simply fitting the unit onto the rail and
pressing gently.
1 First push in
the DIN rail
locking lever.
DIN rail locking lever
DIN rail
5. Wiring and circuit configuration
1) Make all connections according to the
schematic. Polarity should be observed
when wiring DC type.
2) Use of wire-pressed terminal is recommended for connections to pressure connector connect type. For the wire-direct
connect type, strip wire ends to the specified length.
3) When wiring power lines or power cables, twisted pair treatment (standed wire
treatment) should be done in order to improve noise resistance.
4) When the load output device is an inductive load type, installing a diode and
surge absorber to both ends of the load is
recommended.
5) In order to improve noise resistance,
class 3 grounding of the control panel is
recommended.
6) Do not pass the wiring over the surface
of the case. (When unavoidable, keep the
wire at least 3 cm 1.181 inch away from
the surface of the case.)
7) Turn off the power before connecting/
disconnecting connector cables.
8) With some types of control devices,
leakage current may cause the relay to fail
to turn off after the control input is turned
off. Make sure that the relay turns off after
the control input is turned off.
3 Press the unit onto
the DIN rail.
2 Hook the holders on the
unit over the DIN rail.
3) To remove the unit from the DIN rail,
use a flat head screwdriver to pull out the
DIN rail locking lever.
3 Remove the unit from
the DIN rail.
2 Move the
screwdriver in
the direction
of the arrows,
and pull out
the lever.
1 Insert the tip of the
flat head screwdriver
into the slot in the
DIN rail locking lever.
7. Transporting and storage
1) If the product is subjected to extreme
vibration while being transported, the relays may become detached, the lead may
become bent, and the unit may become
damaged. Handle the inner and outer
boxes with care.
2) If the product is stored in an extremely
adverse environment, visible defects and
deterioration of performance characteristics may result. We recommend the following storage conditions.
• Temperature: 5 to 30°C 41 to 86°F
• Humidity: Max. 60% R.H.
• Environment: No hazardous substances such as sulfurous acid gases
and little dust.