ETC S1430UAP912

Photoelectrics
Amplifier, µ-Processor Controlled
Type S1430 UAP, 3 Inputs/3 Transistor Outputs
• µ-Processor controlled
• Amplifier unit for 3 sets of photoelectrics
• 3 independent outputs
• NPN/PNP both NO or NC selectable
• Self-diagnostic functions
• Alignment failure indication
• Multivoltage 12 to 30 VAC/DC
• Modulated and synchronized light
• Adjustable sensitivity for each channel
• LED indications: supply, outputs, signal quality
• 11-pin plug-in housing
• For 115 or 230 VAC use power supplys from SS120-series
Product Description
µ-Processor controlled amplifier for 3 sets of photoelectric sensors, type MOFTR,
MKFTR, MIFTR or MHFTR.
Utilising an 11-pin circular
plug for easy connection,
outputs freely selectable for
NPN/PNP or NO/NC. Self-
Ordering Key
diagnostics for system test.
Protected against short-circuits, reverse wiring or cross
talk from adjacent photoelectrics. Multi-voltage power
supply. Sensitivity is individually adjustable for each
set of photoelectrics.
S14 30 UAP 912
Type
Special function
Output type
Power supply
Type Selection
Plug type
Ordering no.
Supply: 12 - 30 VAC/DC
Circular, 11 pins
S 1430 UAP 912
Specifications
Rated operational voltage (UB)
pins 2 & 10
DC
AC
Rated operational power
AC supply
DC supply
Power ON delay (tv)
Output function
Output current
Continuous (Ie)
Short-time (I)
Min. load current (Im)
OFF-state current (Ir)
Voltage drop (Ud)
Protection, outputs
Supply to photoelectric switch
Emitter
Supply voltage (open loop)
Current
Output resistance
10.8 to 33 VDC
10.8 to 33 VAC, 45 to 65 Hz
4 VA
3W
< 300 ms
NPN and PNP switching
Make and break function
DIP-Switch selectable
100 mA per output
100 mA max.
0.5 mA
Max. 100 µA
≤ 3.5 VDC
Reverse polarity, short-circuit,
transients
Tx1: Pin 1
Tx2: Pin 9
Tx3: Pin 6
Shield: Pin 11 (common)
7 V square wave
≤ 300 mA short-circuit protected
10 Ω
Specifications are subject to change without notice (25.06.99)
Supply to photoelectric switch
(cont.)
Receiver
Rx1: Pin 4
Rx2: Pin 7
Rx3: Pin 8
Shield: Pin 5 (common)
Supply voltage (open loop)
5 VDC
Short-circuit current
10 mA
Input resistance
470 Ω
Sensitivity
• 2 ranges,
DIP-Switch selectable
(% of Sn)
- low sensitivity (25%)
- high sensitivity (100%)
• Sensitivity adjustment
with 270°:
Turn knob on CH 1, 2, 3
Note:
• Maximum range indicated on photoelectric
switch data sheet in high
sensitivity range only
• Operation within low
sensitivity range, increases ambient light and
crosstalk immunity
Operating frequency (f)
Light/dark ratio 1:1
16 Hz
1
S 1430 UAP
Specifications (cont.)
Response time
OFF-ON (tON)
ON-OFF (tOFF)
Indication
Supply ON
Output ON
Signal quality
Environment
Overvoltage category
Degree of protection
Pollution degree
Temperature
Operating
Storage
Weight
Approvals
CE-marking
Truth Table
Make switching
20 ms
20 ms
Object present
LED, green
LED, yellow
LED, red
Dirt on lenses,
misaligned or
sensitivity too low
III (IEC 60664)
IP 20 (IEC 60529, 60947-1)
3 (IEC 60664/60664A,
60947-1)
Output LED yellow OFF
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to 185°F)
150 g
CSA
Yes
Level LED red
Yes
No
No
Yes
No
No
--
No
Yes1)
--
No
Yes1)
ON
ON
OFF
ON
ON
ON
or
flashing
OFF
OFF
ON
or
flashing
ON
ON
OFF
OFF
OFF OFF
Output NPN/PNP OFF
1)
Break switching
ON
Under normal operating conditions, the red level indication
LED has to be OFF. The level indication LED will turn on
shortly each time an object enters or exits the sensing
zone, even if the photoelectric switch is correctly installed
and adjusted.
Procedure for Test Functions (Dip-Switch Selection)
Transmitter test
(switch 5 in the up position)
When switch 5 is placed in
the up position all yellow and
red LED’s on the front of the
unit will flash simultaneously.
Once the test is completed
(approx. 3 scans) and a
wiring fault is detected, such
as reverse polarity or shortcircuit, the transmitter that
has the fault condition will
be indicated by the red LED
being continuously ON. If a
fault condition is not existing
then only the yellow LED will
be ON. If a fault exists, correct the fault condition and
then repeat the test, this will
ensure proper wiring has
been done. Always reset
switch 5 for normal operation of system when testing
completed.
Receiver test
(switch 6 in the up position)
When switch 6 is placed in
the up position all yellow and
red LED’s on the front of the
unit will flash simultaneously.
Once the test is completed
(approx. 3 scans) and a
wiring fault is detected, such
as reverse polarity or shortcircuit, the receiver that has
the fault condition will be
indicated by the red LED
being continuously ON. If a
fault condition is not existing
then only the yellow LED will
be ON. If a fault exists, correct the fault condition and
then repeat the test, this will
ensure proper wiring has
been done. Always reset
switch 6 for normal operation of system when testing
completed.
Function test
(switch 5 and 6 in the up position)
When switch 5 and 6 are
both placed in the up position (simultaneously) the yellow and red LED’s on the
front of the housing will
begin to flash simultaneously and then the LED’s
will cycle from channel 1 to
channel 2 and then to channel 3. Once the complete
system scan is done the
indication of the system
condition will be displayed
(see below). System test will
continue until switch 5 and 6
are reset.
LED Indication
Yellow LED ON
!
Red LED OFF
}
System Test OK
!
Yellow LED ON
Red LED ON
}
Tx’s and Rx’s mismatched,
e.g. Rx3 seeing Tx1
!
Yellow LED OFF
Red LED ON
}
Alignment error or beam
obstructed by object
Operation Diagram
Signal strength
Time
Power supply
Object present
Signal quality
Break switching
!
Make switching
2
Specifications are subject to change without notice (25.06.99)
S 1430 UAP
Dimensions
DIP-Switch (located behind cover):
35
80
1: PNP/NPN CH 1 output
SW 1 2 3 4 5 6
2: PNP/NPN CH 2 output
3: PNP/NPN CH 3 output
4: Low sensitivity (25%) / high sensitivity (100%)
5: Test button, transmitters are transmitting, no short, wired correctly
6: Test button, receivers are receiving, no short, wired correctly
5+6 together: System test (transmitter and receiver)
sw 1, 2, 3:
sw 4:
PNP make/NPN break
Range 25%
NPN make/PNP break
Range 100%, normal operation
84
sw 6:
sw 5:
Transmitter test
Receiver test
Normal operation
Normal operation
sw 5+6:
System test
4
75
5
Normal operation
Wiring Diagrams
Rx 1
Tx 1
Rx 2
Tx 2
Rx 3
1
Rx
Tx 31
6
5
7
4
8
3
9
2
10
1
11
Power Supply
ON sockets
1: Transmitter 1
2: Supply (+ VDC)
3: No connection
4: Receiver 1
5: GND (Receivers)
6: Transmitter 3
7: Receiver 2
8: Receiver 3
9: Transmitter 2
10: Supply (- VDC)
11: GND (Transmitters)
Accessories
-
11 pole circular socket
Socket cover for S111
Socket cover for S411
Holding down spring
Mounting rack
Front panel mounting bezel
Connection cable (2 plugs)
2 x 6/6 modular plugs
- Power supply for 115/230 VAC
- DIN-rail interface
Wire colour coding
white
black
red
green
yellow
blue
PNP
NPN
B C D
A B C D
10-40
VDC
F
F
+
-
10-40
VDC
+
-
Interface
S111, S111A, S411, ZPD11
BB1
BB4
HF
SM13
FRS2
2.0 m, 6 wires two plugs
SS120-series
6IODC
Delivery Contents
• Output connection cable
• Output connection cable
• Amplifier
• DIN-rail interface
• Screw driver
• Packaging:
Output
A: + (10-40 VDC)
B: Output 1 (max. 100 mA)
C: Output 2 (max. 100 mA)
D: Output 3 (max. 100 mA)
E: For handheld tester
F: - DC
1 m, 6 wires one plug
0.2 m, 6 wires two plugs
S 1430 UAP 912
6IODC
6IODC
DIN-rail interface
(DIN EN 50 035, EN 50 022)
output from plug to screw
terminals
Cardboard box
Specifications are subject to change without notice (25.06.99)