Snap/Clip-Lock Environmentally Sealed - Circular Engineering Quick Reference Selection Guide Plug 5 Position 4 Position 2 Position Receptacle Plug Contact Arrangement Contact Cannon 1 2 2 Receptacle 2 2 1 1 3 5 4 3 4 1 5 Inline Feed Thru Inline PCB Inline Clip Lock Clip Lock Clip Lock Snap Lock Snap Lock Specifications CS-216 CS-216 CS-216 CS-206 CS-206 Plug 086-0066-000 w/Wedgelock 086-0058-000 Standard 086-0058-000 Standard Contact Cannon 098532-0000 (5 A) 098532-001 (13 A) 098532-0000 (5 A) 098532-001 (13 A) Receptacle 086-0061-000 w/Wedgelock 083-0242-000 Contact Cannon 098531-0000 (5 A) 098531-0001 (13 A) 098530-0000 (5 A) 098530-0001 (13 A) Terminals See page 14 See page 14 Contact Cannon See page 14 See page 14 Features How to Order SLC 5 T 13 0 0 Series Prefix Size/Configuration Connector Type Contact Termination Material/Finish Modifier Mechanical Modifier Series Prefix SLC - Snap-Lock Circular Size/Configuration 5-5 Cavity Housing 8-8 Cavity Housing 10-10 Cavity Housing 15-15 Cavity Housing Contact Termination 5-5A 13 - 13 A Material/Finish Modifier 0 -Standard Assembly (Silicone Elastomer) 1 -Fluorosilicone Elastomer Mechanical Modifier Connector Type 0 -Standard Assembly P - Plug, In-line (Cable-to-Cable)* R - Receptacle, In-line (Cable-to-Cable) T - Receptacle, Snap-thru B - Receptacle, PCB *Note: In-line Plug mates with all 3 receptacle types (In-line, Snap-thru, and PCB.) Dimensions shown in mm Specifications and dimensions subject to change 4 www.ittcannon.com Snap/Clip-Lock Environmentally Sealed - Circular Engineering Quick Reference Selection Guide Plug 15 Position 10 Position 8 Position Receptacle Plug Receptacle Plug 4 3 12 3 1 7 2 2 8 5 4 7 8 5 3 4 4 2 2 1 3 4 3 6 Receptacle 11 4 13 2 1 5 5 10 9 1 9 9 7 7 8 2 10 14 15 6 6 6 8 10 8 6 8 9 6 7 7 PCB Inline Snap-thru PCB Inline Snap-thru Snap-thru Snap Lock (Double) Snap Lock (Double) Snap Lock (Double) Snap Lock (Double) Snap Lock (Double) Snap Lock (Double) Snap Lock (Double) CS-210 CS-210 CS-210 CS-206 CS-206 CS-210 CS-210 098532-0010 098532-0008 098532-0010 098532-0002 (5 A) 098532-0002 (5 A) 098532-0002 (5 A) 098532-0003 (13 A) 098532-0003 (13 A) 098532-0003 (13 A) 086-0060-000 - - 098533-0010 098531-0002 (5 A) 098530-0002 (5 A) 098531-0003 (13 A) 098530-0003 (13 A) 098533-0002 098533-0003 086-0059-000 See page 14 See page 14 See page 14 See page 14 See page 14 See page 14 See page 14 Dimensions shown in mm Specifications and dimensions subject to change www.ittcannon.com 5 3 11 15 14 5 10 1 12 13 5 1 Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular The Snap Lock Environmental Series is environmentally sealed connector created for printed circuit board, black box, cable-to-cable or bulkhead applications. When your under-the-hood requirements call for tough performance, the SLC "snaps" into a tightly sealed connection that can withstand heat, shock and vibration. The connector is designed to preserve the integrity of the solid state package, while protecting against contaminants - even when unmated. Gold, tin/lead plated stamped contacts add durability. A rugged, thermoplastic receptacle body maximizes performance by withstanding temperature variances from -40°C to +150°C (material rating). The SLC series is available in 2, 5, 8, 10, 15 contact cavity configurations. It can also be adapted to robotics assembly. Should you requirement demand higher density configurations, consult Customer Service. Product Features and Benefits · Superior environmental sealing · Material rating: -40°C to +150°C continuous operation at rated current · Available in sizes 2, 5, 8, 10, 15 contacts · Crimp stamped gold, tin/lead plated contacts · Hand insertable/removable contacts · Current rating 5 A and 13 A versions · Low millivolt drop · Low contact resistance · Small footprint on P.C. board and low profile · Adaptable to robotics assembly · Latch with tactile and audible feedback · Increases durability and provides for minimum installation · Low installed cost · Requires less PCB space Performance Specifications Contact Resistance Insulation Resistance Current Rating Dielectric Withstanding Voltage Applicable Cannon Specification Material Rating Operating Temperature Crimp Contacts Wire Size Wire Insulation Sealing Range Contact Insertion Contact Extraction Contact Retention Wire Strip Length 10mΩ maximum 20MΩ minimum (USCAR) 5 A signal continuous at 150°C all contacts, 2 position 13 A power continuous at 150°C all contacts, 5 position and 10 position only 1000 Vrms AC at sea level SLC (CS-206) SLCT 5 & 10 (210) SLCT8 (216) SLCT 15 (206) -40°C to +150°C Semi-automatic or hand crimpable or fully automatic 20 - 16 AWG 1,98 (.078) to 3,30 (.130) dia. No tool required. Suitable for automation. Rear Removable 20 lbs. Minimum per contact 5,59 (.220) to 5,33 (.210) Materials and Finishes Connector Housing Contacts Finish Environmental Seal High temperature thermoplastic Copper alloy Engaging area: Gold over nickel Crimp/P.C. tail area: Tin/lead over nickel - standard offering Tin/Lead over nickel - Option #2 all over High temperature silicone elastomer Dimensions shown in mm Specifications and dimensions subject to change 6 www.ittcannon.com Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Contact Cavity Arrangements - Mating Face View Plug 2 1 1 1 2 3 5 8 3 6 4 4 5 5 Way 2 Way 2 7 8 Way 3 3 2 11 2 1 13 5 10 5 10 9 6 8 4 12 4 14 15 1 9 8 7 6 7 10 Way 15 Way Receptacle 2 2 3 2 1 4 1 1 3 4 5 2 Way 5 Way 3 12 2 5 10 2 1 1 7 11 8 5 14 15 9 8 7 10 Way 15 Way Dimensions shown in mm Specifications and dimensions subject to change www.ittcannon.com 7 4 13 10 9 6 6 8 Way 3 4 7 8 5 6 Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Plug, In-line* (Cable-to-Cable) (Type P) SLC-5, SLC-10 Side View Plug Assembly Front-Face View 5 Cavity Housing Front-Face View 10 Cavity Housing In-line Plug* (Mates with SLC types R, T, and B) Housing Size Rating Part Number Description 5 5A 098532-0011 SLC-5P5-00 27,81 (1.095) A 18,03 (.710) ØB 5 13 A 098532-0001 SLC-5P13-00 26,80 (1.055) 18,03 (.710) 10 5A 098532-0002 SLC-10P5-00 34,92 (1.375) 24,15 (.990) 10 13 A 098532-0003 SLC-10P13-00 34,04 (1.340) 25,15 (.990) *Contact lead assemblies are customer terminated and installed. See page 14, part numbers 110238-0488, 110238-2003. Dimensions shown in mm Specifications and dimensions subject to change 8 www.ittcannon.com Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Receptacle, In-line* (Cable-to-Cable) (Type R) SLC-5, SLC-10 Side View Receptacle Assembly Front-Face View 5 Cavity Housing Front-Face View 10 Cavity Housing In-line Receptacle* (Mates with SLC type P) Housing Size Rating Part Number Description 5 5A 098530-0000 SLC-5R5-00 A ØB 5 13 A 098530-0001 SLC-5R13-00 23,75 (.935) 18,03 (.710) 24,38 (.960) 10 5A 098530-0002 SLC-10R5-00 31,24 (1.230) 25,15 (.990) 31,62 (1.245) 10 13 A 098530-0003 SLC-10R13-00 30,86 (1.215) 25,15 (.990) 31.62 (1.245) 24,13 (.950) C Ref. 18,03 (.710) 24,38 (.960) *Contact lead assemblies are customer terminated and installed. See page 16, part numbers 110238-0446, 110238-2004. Square Flange Snaps onto Type R and B connectors Materials and Finishes Material: Thermoplastic Color: Black Housing Size Part Number 5 066-9504.000 23,37 (.920) A 31,24 (1.230) 32,51 - 31,75 (1.280 - 1.250) 10 066-9504-001 28,45 (1.120) 36,32 (1.430) 25,40 - 24,64 (1.000 - .970) Dimensions shown in mm Specifications and dimensions subject to change www.ittcannon.com 9 B Max. ØC Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Receptacle, Snap-thru* (Type T) SLC-5, SLC-10 Front-Face View 10 Position Side View Front-Face View 5 Position Panel Rear Face View Panel Section View Snap-thru Receptacle* (Mates with SLC Type P) Housing Size Rating Part Number Description 5 5A 098533-0000 SLC-5T5-00 37,21 (1.465) ØA 24,13 (.950) ØB 25,60 (1.008) ØC 15,62 (.615) ØD 5 13 A 098533-0001 SLC-5T13-00 36,96 (1.455) 23,75 (.935) 25,48 (1.003) 15,34 (.605) 10 5A 098533-0002 SLC-10T5-00 47,62 (1.875) 31,24 (1.230) 35,05 (1.380) 20,19 (.795) 10 13 A 098533-0003 SLC-10T13-00 47,37 (1.865) 30,86 (1.215) 34,92 (1.375) 19,94 (.785) *Contact lead assemblies are customer terminated and installed. See page 14, part numbers 110238-0446, 110238-2004. Dimensions shown in mm Specifications and dimensions subject to change 10 www.ittcannon.com Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Receptacle, PCB* (Type B) SLC-5, SLC-10 Front-Face View 5 Cavity Housing Front-Face View 10 Cavity Housing Side View In-Line Receptacle With PCB Contacts In-line Receptacle* (Mates with SLC Type P) Size Rating Part Number Description 5 5A 098531-0000 SLC-5B5-00 24,13 (.950) 18,03 (.710) 24,38 (.960) 5 13 A 098531-0001 SLC-5B13-00 23,75 (.935) 18,03 (.710) 24,38 (.960) 10 5A 098531-0002 SLC-10B5-00 31,24 (1.230) 25,15 (.990) 31,62 (1.245) 10 13 A 098531-0003 SLC-10B13-00 30,86 (1.215) 25,15 (.990) 31,62 (1.245) *PCB Contacts are factory installed. Recommended PCB Layout Dimensions shown in mm Specifications and dimensions subject to change www.ittcannon.com 11 A ØB C Ref. Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Receptacle, Snap-thru SLCT-8 48,26 (1.900) Part No.: 098533-0010 (mates with 098532-0008) 27,56 (1.085) Receptacle, Feed-thru CLC-2 Part No.: 086-0057-000 13,85 (.550) STRAIGHT PIPE THREAD SEALED INTERFACE fl SEALED INTERFACE 10,10 (.400) 4,45 (.175) 22,90 (.900) PANEL MAX Note: In-line plug and receptacle available. 20,30 (.800) 15,90 (.600) 44,00 (1.700) Plug, Feed-thru CLC-2 Part No.: 086-0058-000 With Silicone Grommet Seal Part No.: 086-0058-001 With Silicone Grommet Seal Part No.: 086-0058-002 With Fluorosilicone Seal 32,26 (1.270) 23,00 (.900) 16,60 (.650) 13,20 (.520) A 4,45 (.175) B 19,30 (.760) Right Angle CLC and CLC Y-Splice, please contact Product Management. Dimensions shown in mm Specifications and dimensions subject to change 12 www.ittcannon.com Snap/Clip-Lock Environmentally Sealed - Circular Plug, Snap-thru SLC-15 Part Number: 086-0060-000 Receptacle, Snap-thru SLC-15 Part Number: 086-0059-000 Consult factory for alternate layouts. Dimensions shown in mm Specifications and dimensions subject to change www.ittcannon.com 13 Cannon SLC/SLC-T/CLC Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Contacts, Stamped, 5 and 13 Amp Socket (use in plugs) Description 5A 13 A Hooded Socket Socket Part Number 110238-1016 (030-2480-007) Hooded Socket Pin (use in receptacles) Reeled Pin Part Number 110238-0446 (030-2464-007) 110238-2004 (030-2464-003) Socket Part Number 110238-0488 (030-2480-000) 110238-2003 (030-2480-003) Number of Contacts 4,500 4,000 Accessories Sealing Plugs Connector Clip Material: Thermoplastic, Color: Natural Part Number: 225-0093-000 +125°C Rating Material: Thermoplastic, Color: Natural Part Number: 225-0093-000 +125°C Rating Mounting Hardware for use on In-line Receptacle (Cable-to-Cable) (Type R) Fits Ø6,35 (.250) hole x 0,51 (.020) thick panel. Dimensions shown in mm Specifications and dimensions subject to change 14 www.ittcannon.com Snap/Clip-Lock Environmentally Sealed - Circular Cannon SLC/SLC-T/CLC Extraction Tool Contact Extraction Tool Part Number: 274-7068-001 Tip Part Number: 323-9519-000 A Standard CET - SLE/SLC is available for extraction of the individual crimp contacts. Insertion tool is not required. Insertion / Extraction Instructions for Crimp Contacts Insertion Tool No insertion tool is required. The contact is easily snapped in from the rear of the connector manually. 1. Move to the rear of the connector so that the contact cavities can be identified. 2. Insert a crimp terminated assembly into a selected cavity. 3. Continue the forward movement until and audible snap can be felt and heard. Slight pull in the opposite direction will confirm complete insertion. Extraction 1. Open the CET - SLC Extraction tool and place it over the insulation of the wire. 2. Using a straight motion forward, insert the tool along the wire until it bottoms against the connector. (Do not use a screwing motion damage will result.) 3. While the extraction tool is in place, simply pull the wire/contact assembly out. Dimensions shown in mm Specifications and dimensions subject to change www.ittcannon.com 15 4. Remove the extraction tool. Extraction is complete. Snap/Clip-Lock Environmentally Sealed - Circular Cannon SLC/SLC-T/CLC Hand Crimp Tool Operation Hand Crimp Tool - CCT - SLC / SLE Part Number: 995-0002-232 The CCT-SLC/SLE hand crimp tool is designed to crimp individual SLC/SLE contacts on wire sizes 16, 18, and 20 AWG. Each cycle is ratchet-controlled (The tool must be completely closed before it can be reopened) to assure a satisfactory crimp each time. Over and under crimps are eliminated. This tool is for use when the requirement is for low to moderate volume quantities, and for on-site applications where semiautomatic tools cannot be practically used. 1. Cycle the CCT - SLE / SLC hand tool to the open position. 2. While pressing upward on the locator spring, insert the contact with tails upward completely into the locator. 3. When correctly positioned the contact should be located beyond flush with the edge of the CCT - SLE / SLC and positioned in the concave polished split level crimp. 4. Partially (usually the first click) Cycle the hand tool assuring that the upward thrusting tails of the contact has started engaging with the top jaw of the tool. (There is a slight tendency for the contact to roll out of vertical alignment.) 5. Insert the pre-stripped wire into the crimp area of the contact and completely cycle the tool. 6. While pressing upward on the locator spring withdraw the crimp termination. Wire Stripping 7. The result will be a perfect termination. 8. Note that there are no unterminated wire strands, and that some strand ends can be seen at the forward edge of the crimp. Also note the insulation is gripped by the smaller secondary crimp. Distortion is at a minimum, both axially and laterally - no sharp edges. Tolerance Low High 5 and 13 A Contact B A 5,33 (.210) 2,41 (.095) 5,59 (.220) 3,30 (.130) Dimensions shown in mm Specifications and dimensions subject to change 16 www.ittcannon.com Snap/Clip-Lock Environmentally Sealed - Circular Cannon SLC/SLC-T/CLC Lease Automatic Tooling - North America* ABT-607 Pneumatic Crimper The ABT-607 is a pneumatic powered and controlled machine. It is designed for customers with moderate volume. This machine is designed to semiautomatically crimp stamped and formed contacts onto pre-stripped stranded or single conductor electrical wire. This machine will accommodate size 34 thru 12 AWG wire and is actuated by the use of a foot pedal. Machine Crimp Rate: 800 per hour The ABT-500 Universal Cannon Crimp Die, is a flywheel driven, electronically controlled machine that is designed to semi-automatically crimp stamped and formed contacts on stranded or single conductor, prestripped wire. This machine will accommodate size 34 thru 12 WG wire. The machine is actuated by the use of a foot pedal. Machine Crimp Rate: 1300 per hour The ABT-620 Universal Cannon Crimper/Stripper is a pneumatic powered, microprocessor controlled machine. It is designed to semi-automatically strip insulation from stranded or single conductor electrical wire and attach a stamped and formed contact by crimping. The machine will accommodate 34 thru 12 AWG wire. Primary application of the machine is the termination of jacketed cable where the individual leads cannot be stripped by fully automated equipment. The ABT-620 UCCS operates automatically upon insertion of a wire or it can be switched over to foot pedal operation if desired. Machine Crimp Rate: 1200+ per hour Power Requirements: Pneumatic = 100 psi, 2 cu. ft. per min. ABT-500 UCCD Power Requirements: Electrical = 115VAC, 60Hz, 20A ABT-620 UCCS * For other geographical regions, contact Cannon for details. Dimensions shown in mm Specifications and dimensions subject to change www.ittcannon.com 17 Power Requirements: Electrical = 115VAC, 60Hz, 20A Pneumatic = 80 psi, 3 cu. ft. per min. Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Crimp Pot Cross Section D CRIMP WIDTH C CRIMP HEIGHT Crimp Height and Width CRIMP POT CROSS SECTION The wire crimp heights listed are only reference and valid for the correspondingly listed wire size, wire plating and wire stranding. The wire crimp tensile values must be used to assure the performance of crimped contacts. For wire crimp information not listed in this table, please contact Cannon. Crimp Tensile Strength Wire Gauge (AWG) 18 D Ref. C* D Ref. C* Signal (5A) .064* .082 .056* .080 Power (13A) .066* .082 .062* .080 * Hand Tools are ± .002 and machines are ± .001 20 16 C* .054* .058* D Ref. .080 .080 Insulation Height and Width Wire Gauge (AWG) 18 Width Height Height Max Max** Max Signal (5A) .110 .115** .105 Power (13A) .110 .115** .105 ** Measurements are taken without crimping wire insulation. 20 16 Width Max** .110** .110** Height Max .105 .105 Width Max** .110** .110** Wire Trim Dimension (.220 - .210) (.130 - .095) 16 35 lbs. Wire Size (AWG) Tensile Min (lbs) 18 25 lbs. 20 20lbs. Dimensions shown in mm Specifications and dimensions subject to change 18 www.ittcannon.com Cannon SLC/SLC-T/CLC Snap/Clip-Lock Environmentally Sealed - Circular Test Parameters SLC Products are designed to meet Cannon specifications CS-206, CS-210, and CS-216. Items of most general interest to users are designers are listed below. Test Description Reference Paragraph Requirements Environmental Sealing 3.2.3.5 3.2.3.6 3.2.3.7 3.2.3.8 3.2.3.9 3.2.3.2 Sand and Dust MIL-STD-202 Method 110 Test Condition A 5% salt spray 96 hours 10 cycles of 24 hours, 90-98% humidity Steam Cleaning/Pressure Wash 95°C, 375 Cycles 750 PSIG Solvent Resistance/Immersion (see 3.2.3.9) Thermal Shock 100 Cycles -40°C to +150°C ± 3°C Contact Crimp Tensile Strength 3.2.2.1 The minimum tensile load required to separate the wire from the contact, either by pulling the wire out of the crimp joint or by breaking the wire within the crimp joint shall not be less than the applicable limits as specified. Wire breakage or contact damage not due to crimping at less than tensile loads shall not constitute a failure. Wire Size AWG Crimp Tensile Strength, Pounds Minimum 16 35 18 25 20 20 Insulation Resistance 3.2.1.1 Mated and wired connectors shall exhibit an insulation resistance greater than 100 megohms between all contacts. This limit shall apply after exposure to each environment including salt solution immersion. Tests shall be performed at 100 VDC ± 10%. Dielectric Withstanding Voltage Low Level Contact Resistance Mechanical Shock 3.2.1.2 Wired and mated connectors shall show no evidence of breakdown between adjacent contacts when tested at 1000 VDC ± 5%. Connectors shall meet this requirement after exposure to each environment. Current leakage shall be less than 1.0 milliamp. 3.2.1.4 The low level contact resistance of mated contacts shall be less than 10 milliohms when measured across the contacts and crimp joints. The test current shall be a maximum of 100 milliamps with an open circuit test voltage of 20 millivolts maximum. 3.2.3.3 Connectors shall be subjected to three shocks in each direction applied along the three mutually perpendicular axes of the connector test specimen for a total of 12 shocks. Each shock shall consist of a terminal peak sawtooth pulse with a peak value of 100 g's and a duration of 6 milliseconds. Vibration 3.2.3.4 Connectors shall be subjected to random vibration in accordance with MIL-STD-1344, Method 2005.1, test condition VI for 20 hours along each of the following three axes: Direction Grms Radial axis of connector (Y) 10.2 Longitudinal axis of connector (Z) 10.2 Electrical continuity of the connectors shall be monitored during the last 20 minutes sweep in each axis with a test current of 100 milliamps or less and a test voltage less than 2VDC. Electrical discontinuities in excess of 10 microseconds shall be cause of failure. Durability 3.2.2.6 Connectors shall be subjected to 25 cycles of mating and unmating at room temperature. Following this test there shall be no evidence of damage to the contacts, contact plating, connector housing or seals which may prove detrimental to reliable performance of the connector. Contact 3.2.2.2 Contacts shall not be displaced greater than 0.030 inches from the connector body when a force of 10 pounds is applied. When this test follows maintenance again the same contacts shall be tested. Maintenance Aging 3.2.2.3 Consist of subjecting each wired receptacle to 5 cycles of removal and reinsertion of 20% of the contacts or a minimum of 5 per connector with approved tooling. Mating and Separating Force Solvent Resistance Immersion 3.2.2.4 The maximum force required to mate the plug and receptacle shall be 10 pounds. The maximum force required to separate the plug and receptacle shall be 5 pounds. The rate of travel shall be one inch per minute. 3.2.2.9 Connectors shall be subjected to the following fluids at the temperature and length of time specified. Following the fluid dip or immersion, the connectors shall be immersed to a depth of 2 to 12 inches in a 5% salt-water solution for 24 hours at room temperature. At the completion of the salt-water immersion test, while still immersed, the connectors shall meet the insulation resistance requirement specified herein. Fluid Method Temperature No. 2 Diesel Fluid Immersion (2) 140°F Methyl Alcohol Dip (1) Room Temperature Antifreeze - Prestone Immersion (2) 180°F - 50% Water/50% Immersion (2) 180°F Ethylene Glycol Degreaser - Gunk Dip (1) Room Temperature - Mineral Spirits Dip (1) Room Temperature Paint (Oil Base) Immersion (2) Room Temperature Lubricating Oil Immersion (2) 200°F (SAE 10 W40) Dip (1) Room Temperature Brake Fluid (Delco Supreme) Room Temperature Dip (1) Transmission Fluid fully submerged and pressurized @ 7 psi. (Dextron) (1) Dip: Connectors shall withstand a one second dip and a three minute air dry for a total of 80 cycles. (2) Immersion: Connectors shall withstand immersion for one hour. Temperature Life 3.2.3.1 Connectors shall be subjected to a temperature of 150°C ± 3°C for a period of 1000 hours. At the end of the temperature soak period and after removal from the chamber, the connectors shall meet the insulation resistance and dielectric withstanding voltage requirements specified herein. Connectors shall be operated at rated current throughout the duration of the temperature life test. Upon removal from the chamber at the conclusion of the test, the connectors shall show no visual signs of damage, which may be detrimental to the performance of the connector. Thermal Cycling 3.2.3.2 Connectors shall be subjected to 100 thermal cycles from -40°C to +150°C. One cycle shall consist of the transitions from room temperature to -40°C to +150°C, and from 150°C to room temperature. One cycle shall be accomplished in a three-hour period with a minimum stabilization period of 15 minutes at each temperature extreme. The chamber temperature transition rate shall be a minimum of 1.30°C per minute and a maximum of 6.00°C per minute. Specifications and dimensions subject to change www.ittcannon.com 19