CRANE SLH2805S/KR

Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
Features
Small size, 0.8 inches2 (5.16 cm2)
• Operating temperature -55° to +125°C
• Qualified to MIL-PRF-38534 Class H and K
• Radiation hardness assurance (RHA) to level R 100 kRad(Si)
• Input voltage range 16 to 40 VDC
• Fully isolated, magnetic feedback
• Inhibit function
• Indefinite short circuit protection
models
VDC Output
• High power density, 88% efficiency
singles
5
12
15
description
With a miniature footprint of just 0.8 square inches, the SLH
Series™ of 28 V DC/DC converters delivers 1.5 watts of output
power while saving significant board area. The wide input voltage
range of 16 to 40 VDC accepts the varying voltages of space,
military, or aerospace bus power and tightly regulates output voltages to protect downstream components. Single output models
feature outputs of 5, 12, or 15 volts, and dual output models
feature outputs of ±5, ±12 and ±15 volts.
Screening
SLH converters offer the following screening options: Space
Prototype (O), Class H, or Class K. Radiation tolerant to
Radiation Hardness Assurance (RHA) levels of “-” (O) or “R”,
per MIL-STD-38534. Interpoint model numbers use an “O” in
the RHA designator position to indicate the “-” (dash) Radiation
Hardness Assurance level of MIL-PRF-38534, which is defined
as “no RHA”. See “Class H and K, QML Screening” tables for
more information.
When used with Interpoint’s STF28-461 filter, the combination will
meet the requirements of MIL-STD-461C, CE03.
Inhibit Function
The SLH Series incorporates an inhibit terminal that can be used
to disable internal switching. The converter is inhibited when an
active low (≤ 0.5 V) signal is applied to the inhibit pin (pin 7). In
the inhibit mode the inhibit pin sources up to 2 mA maximum.
The converter resumes normal operation when an open circuit is
applied to the inhibit pin. The open circuit voltage of the inhibit is
7 to 8 volts. Do not apply an external pull-up to the converter.
Protection Features
All models include a soft-start function to prevent large current
draw and minimize overshoot. The converters provide short
circuit protection (by restricting the current) and output overload
protection.
Convenient Packaging
Converter Design
SLH Series DC/DC converters incorporate a flyback topology
with a ­variable switching frequency. Feedback provides output
voltage regulation. Output voltage is magnetically fed back to the
input side of the PWM to regulate output voltage.
The SLH Series converters are packaged in hermetically sealed
metal cases which provide EMI/RFI shielding.
Up to 80% of the load of the dual output models may be on one
output providing that the other output carries a minimum of 20%
of the total load. The dual models can be used as a single output
voltage by connecting the load between positive and negative
outputs, leaving the common unconnected resulting in double the
output voltage. (for example, SLH2805D can be used as a 10
VDC output.)
Crane Aerospace & Electronics
Electronics Group (Interpoint Brand)
PO Box 97005 • Redmond WA 98073-9705
425.882.3100 • [email protected]
www.interpoint.com
duals
±5
±12
±15
Page 1 of 10
Rev C - 20090318 - Pending Revision C Release
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
Operating Conditions and characteristics
Input Voltage Range
•16 to 40 VDC continuous
•50 V for 50 msec transient
Output Power
•1.5 W
Lead Soldering Temperature (10 sec per lead)
•300°C
Inhibit
•Active low (output disabled)
‣‣INH referenced to input common
‣‣Active low 0.5 V max
‣‣Inhibit pin current < 2mA
•Active high (output enabled)
‣‣Open collector or unconnected
‣‣Pin voltage 7 to 8 volts, typical (open circuit)
‣‣Do not apply external pull-up
Storage Temperature Range (Case)
•–65°C to +150°C
Capacitive Load
•Single output models 100 µF
•Dual output models 100 µF
Case Operating Temperature (Tc)
•-55°C to +125°C full power
•-55°C to +135°C absolute
Output Voltage Temperature Coefficient
•100 ppm/°C typical
Input to Output Capacitance
•100 to 170 pF typical
Isolation
•100 megohm minimum at 500 VDC
•Any pin to case, except case pin
Conversion Frequency (kHz), 28 Vin, full load
•25°C, 280 typ
•-55°C to +125°C; 220 min, 320 max
Derating Output Power/Current (Tc)
•Linearly from 100% at 125°C to 0% at 135°C
mechanical and environmental
Size (maximum)
•0.980 x 0.805 x 0.270 inches (24.89 x 20.45 x 6.86 mm)
•See case A2 for dimensions.
Weight (maximum)
•12 grams
Screening
Space Prototype (O), Class H, or Class K Radiation tolerant to
Radiation Hardness Assurance (RHA) levels of “-” (O) or “R”,
per MIL-STD-38534. Interpoint model numbers use an “O” in
the RHA designator position to indicate the “-” (dash) Radiation
Hardness Assurance level of MIL-PRF-38534, which is defined
as “no RHA”.
See “Class H and K, QML Screening” tables, page 10. Available
configurations: OO, HR, KR
www.interpoint.com
Page 2 of 10
Rev C - 20090318 - Pending Revision C Release
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
PIN OUT
Pin
Single Output
Dual Output
1
Positive Input
Positive Input
2
Input Common
Input Common
3
Positive Output
Positive Output
4
Output Common
Output Common
5
Case Ground
Case Ground
6
No connection
Negative Output
7
Inhibit
Inhibit
Squared corner and dot on
top of cover indicate pin one.
1 2
3
4
Bottom View
7
6
5
See case A2 for dimensions.
Figure 1: Pin Out
www.interpoint.com
Page 3 of 10
Rev C - 20090318 - Pending Revision C Release
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
SMD Numbers
Model Numbering Key
Standard Microcircuit
Drawing (SMD)
SLH Similar Part
5962R0052601KXC
SLH2805s/KR
5962R0052701KXC
SLH2812S/KR
Output Voltage
Number of Outputs
(S = single, D = dual)
5962R0052801KXC
SLH2815S/KR
5962R0250401KXC
SLH2805d/KR
5962R9955601KXC
SLH2812D/KR
Screening
Radiation Hardness
Assurance (RHA)
5962R9852901KXC
SLH2815D/KR
Base Model
Input Voltage
SLH
28 12 D / K
R
The SMD number shown is for Class K screening and Radiation
Hardness Assurance (RHA) level R. See the SMD for the numbers
for other screening and radiation levels. For exact specifications
for an SMD product, refer to the SMD drawing. Call your Interpoint
representative for status on the SMTR SMD releases which are
“in process.” SMDs can be downloaded from:
http://www.dscc.dla.mil/programs/smcr
Enter
model selection
one
Selection
from each category
SLH28
Base Model
/
VOUT Value
Number of
Outputs 1
Case Option2
Screening 3
RHA 4
5
S
No case options for SLH
O
O
12
D
H
R
15
K
Notes:
1. S is a single output and D is a dual output
2. There are not case options for the SLH. Only the standard case is available.
3. A screening level of O is a Space Prototype and is only used with RHA O.
4. Interpoint model numbers use an “O” in the RHA designator position to indicate the “-” (dash) Radiation Hardness Assurance level of MIL-PRF-38534, which is
defined as “no RHA. RHA O is only available with Screening level O. For more information see page 10.
www.interpoint.com
Page 4 of 10
Rev C - 20090318 - Pending Revision C Release
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
Electrical Characteristics: -55° to + 125°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
Single output models
PARAMETER
SLH2805S
SLH2812s
SLH2815s
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
25°C
4.95
5.00
5.05
11.88
12.00
12.12
14.85
15.00
15.15
4.80
—
5.20
11.52
—
12.48
14.40
—
15.60
OUTPUT VOLTAGE 2
-55
to
+125° C
UNITS
VDC
OUTPUT CURRENT
Vin = 16
to
40 VDC
—
—
300
—
—
125
—
—
100
mA
OUTPUT POWER
Vin = 16
to
40 VDC
—
—
1.5
—
—
1.5
—
—
1.5
W
—
65
150
—
35
200
—
60
200
—
—
250
—
—
300
—
—
300
40 VDC
—
115
300
—
60
400
—
60
650
mV
mV
OUTPUT RIPPLE
25°C, 10 kHz
2 MHz
to
-55 to +125° C,
10 kHz to 2 MHz
LINE REGULATION
Vin = 16
LOAD REGULATION
LOAD 10%
100%
—
440
700
—
380
700
—
410
700
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
16
28
40
16
28
40
16
28
40
—
—
50
—
—
50
—
—
50
NO LOAD
—
2.9
17
—
2.3
17
—
2.4
17
INHIBITED
—
1.3
5
—
1.3
5
—
1.3
5
10 kHz - 10 MHz
—
85
250
—
75
300
—
60
300
25°C, FULL LOAD
72
79
—
80
87
—
80
88
—
69
—
—
69
—
—
69
—
—
SHORT CIRCUIT
POWER DISSIPATION
—
0.4
1.5
—
0.3
1.2
—
0.3
1.2
RECOVERY 1, 8
—
—
30
—
—
30
—
—
30
INPUT RIPPLE
CURRENT 3
EFFICIENCY
-55
STEP LOAD
RESPONSE 1,5
STEP LINE
RESPONSE 6
16 - 40 -16 VDC
START-UP7
to
TRANSIENT 50 ms 1
INPUT CURRENT
LOAD FAULT 4, 5
to
to
+125° C, FULL LOAD
V
mA
mA p-p
%
W
ms
—
±250
±400
—
±220
±700
—
±220
±700
RECOVERY
—
—
400
—
—
400
—
—
400
µs
TRANSIENT
RECOVERY 1, 8
—
—
±600
—
-
±600
—
—
±600
mV pk
—
—
500
—
—
500
—
—
500
µs
DELAY
—
1
20
—
1
20
—
1
20
ms
—
—
500
—
—
500
—
—
500
mV pk
—
—
100
—
—
100
—
—
100
1
25° C, NO EFFECT ON
DC PERFORMANCE
Notes:
All temperatures refer to case temperature, TC.
1. Guaranteed by design, not tested.
2.Specified at 50% load.
3.With a series inductor on the Vin power lead (Lin = 6 µH).
4.Maximum duration of short circuit: 90 seconds at 25°C, 30 seconds at 125°C.
www.interpoint.com
VDC
50% - 100% - 50%
TRANSIENT
OVERSHOOT
CAPACITIVE LOAD 1
mV p-p
mV pk
µF
5.Load fault is a short circuit into 1 . Recovery is into resistive full load.
6.Transition > 10 µs.
7.Measured from release of inhibit until Vout settles to within 1% of final value at full
load with Vin at 28V.
8. Recovery = time to settle to within 1% of Vout final value.
Page 5 of 10
Rev C - 20090318 - Pending Revision C Release
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
Electrical Characteristics: -55° to + 125°C Tc, 28 VDC Vin, balanced 100% load, unless otherwise specified.
dual output models
PARAMETER
OUTPUT CURRENT
OUTPUT RIPPLE
±Vout
SLH2815D
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
25°C
+Vout
4.95
5.00
5.05
11.88
12.00
12.12
14.85
15.00
15.15
25°C
-Vout
-4.95
-5.00
-5.05
-11.88
-12.00
-12.12
-14.85
-15.00
-15.15
-55
to
+125° C +Vout
4.80
—
5.20
11.52
—
12.48
14.40
—
15.60
-55
to
+125° C -Vout
-4.80
—
-5.20
-11.52
—
-12.48
-14.40
—
-15.60
—
150
240
—
62.5
100
—
50
80
—
—
300
—
—
125
—
—
100
Either output
Vin = 16 to 40 VDC
Total, Vin = 16
VDC
OUTPUT POWER
SLH2812D
CONDITIONS
OUTPUT VOLTAGE 2
7
SLH2805D
Vin = 16
to
40
—
—
1.5
—
—
1.5
—
—
1.5
25°C
10 kHz to 2 MHz
—
75
150
—
40
200
—
65
300
10 kHz
—
—
250
—
—
400
—
—
500
to
to
40 VDC
2 MHz
UNITS
VDC
mA
W
mV p-p
LINE REGULATION
Vin = 16 to 40 VDC
+Vout
—
75
400
—
75
700
—
85
650
-Vout
—
65
400
—
70
700
—
85
650
LOAD REGULATION 8
BALANCED, 10% to
100%
+Vout
—
310
700
—
350
700
—
370
700
-Vout
—
300
700
—
350
700
—
370
700
16
28
40
16
28
40
16
28
40
NO LOAD
—
—
—
3.1
50
17
—
—
—
3.1
50
17
—
—
—
3.3
50
17
INHIBITED
—
1.4
5
—
1.4
5
—
1.4
5
10 kHz - 10 MHz
—
80
250
—
90
300
—
100
300
25°C, FULL LOAD
72
80
—
80
87
—
80
87
—
FULL LOAD
69
—
—
69
—
—
69
—
—
SHORT CIRCUIT
POWER DISSIPATION
—
0.3
1.5
—
0.3
1.2
—
0.3
1.2
RECOVERY 1
—
—
30
—
—
30
—
—
30
50% - 100% - 50%
TRANSIENT
—
±150
±400
—
±170
±600
—
±200
±700
RECOVERY 1
—
—
600
—
—
360
—
—
600
µs
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
TRANSIENT 50 ms 1
INPUT CURRENT
INPUT RIPPLE
CURRENT 3
EFFICIENCY
LOAD FAULT 4
±Vout
STEP LOAD
RESPONSE 5
±VOUT
Balanced Load
STEP LINE
RESPONSE 1,5
±VOUT, 16 - 40 -16 VDC
START-UP
±VOUT
CAPACITIVE LOAD1
mV
VDC
V
mA
mA p-p
%
W
ms
mV pk
TRANSIENT
—
—
±600
—
—
±600
—
—
±600
mV pk
RECOVERY
—
—
500
—
—
500
—
—
500
µs
DELAY6
—
1
20
—
2
20
—
2
20
ms
OVERSHOOT 1
—
—
500
—
—
500
—
—
500
mV pk
25° C, NO EFFECT ON
DC PERFORMANCE
—
—
100
—
—
100
—
—
100
Notes (see following page)
www.interpoint.com
mV
Page 6 of 10
Rev C - 20090318 - Pending Revision C Release
µF
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converter Cases
28 Volt input – 1.5 Watt
Electrical Characteristics: -55° to + 125°C Tc, 28 VDC Vin, balanced 100% load, unless otherwise specified.
Notes SLH Dual Output Models:
All temperatures refer to case temperature, TC
1. Guaranteed by design, not tested.
2.Specified at 50%/50% balanced load.
3.With a series inductor on the Vin power lead (Lin = 6 µH).
4.Load fault is a short circuit into 1 . Recovery is into resistive full load.
5.Transition > 10 µs. Recovery is time for Vout to settle to within 1% of final value.
6.Measured from release of inhibit until Vout settles to within 1% of final value at full
load with Vin at 28V.
7. Maximum specification indicates 80% of the converter’s total power is available
from either output, provided the other output carries 20% of the total power.
8. Although no minimum load is required, at no load the output voltage may exceed
rating by up to 15%.
BOTTOM VIEW CASE A2
Projection Weld
Squared corner and dot on
top of case indicate pin one.
0.000
0.135 (3.43)
0.235 (5.97)
0.27 ±0.02
(6.9 ±0.5)
0.000
0.270 max (6.98)
4
6
5
0.835 (21.21)
7
0.097 (2.46)
0.000
3
0.980 max. (24.89)
1 2
0.018 ± 0.002 dia.
(0.46 ± 0.05)
0.435�(11.05)
0.535 (13.59)
0.805 max. (20.45)
0.697 (17.70)
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.3) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage the device.
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin
Materials
Header
Kovar/Nickel/Gold
Cover
Kovar/Nickel
Pins
Kovar/Nickel/Gold matched glass seal
Case A2, Rev D, 20081119
Please refer to the numerical dimensions for accuracy. All information is believed to be accurate,
but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make
changes in products or specifications without notice.
Figure 2: Case A2
www.interpoint.com
Page 7 of 10
Rev C - 20090318 - Pending Revision C Release
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
Class H and K, MIL-PRF-38534 Element Evaluation
Component-Level Test
Performed
Space Prototype (O)
non-QML1
M/S2
P3
Class H
QML
M/S2
Class K
QML
P3
M/S2
P3
Element Electrical
yes
no
yes
yes
yes
yes
Element Visual
no
no
yes
yes
yes
yes
Internal Visual
no
N/A
yes
N/A
yes
N/A
Temperature Cycling
no
no
no
no
yes
yes
Constant Acceleration
no
no
no
no
yes
yes
Interim Electrical
no
N/A
no
N/A
yes
N/A
Burn-in
no
N/A
no
N/A
yes
N/A
Post Burn-in Electrical
no
N/A
no
N/A
yes
N/A
Steady State Life
no
N/A
no
N/A
yes
N/A
Voltage Conditioning Aging
N/A
no
N/A
no
N/A
yes
Visual Inspection
no
no
N/A
no
N/A
yes
Final Electrical
no
no
yes
yes
yes
yes
Wire Bond Evaluation4
no
no
yes
yes
yes
yes
SEM
no
N/A
no
N/A
yes
N/A
SLAM™/C-SAM:
Input capacitors only
(Add’l test, not req. by H or K)
no
no
no
yes
no
yes
Notes:
1. Non-QML products do not meet all of the requirements of MIL-PRF-38534.
2. M/S = Active components (Microcircuit and Semiconductor Die)
3. P = Passive components
4. Not applicable to EMI filters that have no wirebonds.
Definitions:
Element Evaluation: Component testing/screening per MIL-STD-883 as determined by MIL-PRF-38534
SEM: Scanning Electron Microscopy
SLAM™: Scanning Laser Acoustic Microscopy
C-SAM: C - Mode Scanning Acoustic Microscopy
www.interpoint.com
Page 8 of 10
Rev C - 20090318 - Pending Revision C Release
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
Class H and K, MIL-PRF-38534 Environmental Screening
End Item-Level Test
Performed
Space Prototype (O)
non-QML1
Class H
QML
Class K
QML
Non-destruct bond pull2
Method 2023
no
yes3
yes
Pre-cap Inspection
Method 2017, 2032
yes
yes
yes
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to 150°C, ambient
yes
yes
yes
Constant Acceleration
Method 2001, 3000 g
yes
yes
yes
PIND Test
Method 2020, Cond. A
no
yes3
yes
Pre burn-in test
yes
yes
yes
Burn-in
Method 1015, 125°C case, typical
96 hours
160 hours
2 x 160 hours (includes mid-BI test)
yes
no
no
no
yes
no
no
no
yes
Final Electrical Test MIL-PRF-38534
Group A, Subgroups 1 through 6
-55°C, +25°C, +125°C case
yes
yes
yes
Radiography
Method 2012
N/A
N/A
yes
Post Radiography Electrical Test
Room temperature
N/A
N/A
yes3
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
yes
yes
yes
yes
yes
yes
Final visual inspection
Method 2009
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes:
1. Space Prototype (O), non-QML products, do not meet all of the requirements of MIL-PRF-38534.
2. Not applicable to EMI filters that have no wirebonds.
3. Not required by DSCC but performed to assure product quality.
www.interpoint.com
Page 9 of 10
Rev C - 20090318 - Pending Revision C Release
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt
Class H and K, MIL-PRF-38534 Radiation Assurance
ENVIRONMENTAL SCREENING LEVELS
RADIATION HARDNESS
ASSURANCE LEVELS
SPACE
PROTOTYPE (O)
non-QML2
CLASS H
CLASS K
QML
QML
OO
HO
N/A
N/A
HR
KR
O1: Standard, no radiation guarantee
R3: Radiation tolerant–Tested lots up to 100 K
Rads (Si) total dose
SEU guarantee up to 40 MeV
Notes:
1. Interpoint model numbers use an “O” in the RHA designator position to indicate the “-” (dash) Radiation Hardness Assurance level of
MIL-PRF-38534, which is defined as “no RHA”.
2. Space Prototype (O), non-QML, products do not meet all of the requirements of MIL-PRF-38534.
3. Redmond site, Interpoint, has a Radiation Hardness assurance plan on file with DSCC.
SLH Single and Dual, Rev C - 20090318 - Pending Revision C Release. This revision supersedes all previous releases. All technical
information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make
changes in products or specifications without notice. SLH Series is a trademark of Interpoint. Copyright © 1999 - 2009 Interpoint
Corporation. All rights reserved. www.interpoint.com
Page 10 of 10