INTERPOINT SMHP120

FEATURES
•
•
•
•
•
•
•
•
•
•
•
DC/DC CONVERTERS
120 VOLT INPUT
Fully qualified to Class H
–55° to +125°C operation
80 to 175 VDC input
Fully Isolated
Magnetic feedback
Fixed frequency, 600 kHz typical
Topology – Single Ended Forward
Inhibit input and output side
Sync in and out
Indefinite short circuit protection
Size (max.):
Remote sense on single
output models
Weight:
• Up to 85% efficiency
Screening:
• Parallelable up to 180 watts
SMHP120 SERIES
65 WATT
MODELS
VDC OUTPUT
SINGLE
5
12
15
DUAL
±12
±15
3.005 x 1.505 x 0.400 inches (76.33 x 38.23 x 10.16mm)
See Section B8, case U1, for dimensions.
100 grams maximum
Standard or Class H (MIL-PRF-38534)
See Section C2 for screening options, see Section A5
for ordering information.
DESCRIPTION
The SMHP120™ Series DC/DC converters provide up to 65 watts
of output power over the full -55° to 125°C temperature range.
SMHP120 models operate from a MIL-STD-704 nominal 120 volt
DC power bus – from 80 to 175 VDC – continuous operation and
provide isolated outputs at 5, 12, 15, and 28 VDC. Parallel operation for all loading conditions is supported without any requirement
for external components.
SCREENING
SMHP120 converters offer three screening options – Standard, or
Class H. See Section C2, Quality Assurance, pages C2-7 through
C2-9, for descriptions.
PARALLEL OPERATION
Up to five single output SMHP converters may be used in parallel to
power a single load by simply connecting the share pins of all units.
Units in this configuration have a 90% current sharing accuracy over
all loading conditions, and provide true n+1 operation.
FEATURES
Synchronization – units may be synchronized to an external clock or
to one another by using sync in and sync out pins provided on each
unit. The converters have a nominal switching frequency of 600 kHz,
but may be synchronized at any frequency from 525 to 675 kHz.
Low voltage lock-out – shuts down when the input line voltage falls
below approximately 50 VDC to provide smooth initialization.
CONVERTER DESIGN
SMHP120 DC/DC converters are constant frequency, pulse width
modulated switching power supplies which use a quasi-square
wave, two-switch single-ended forward converter design. Tight load
regulation is achieved through a wide-bandwidth magnetic feedback
circuit.
SMHP converters meet a wide variety of military/aerospace
performance and environmental specifications. Their continuous
operation input voltage (80 to 175) meets the normal operating limits
of MIL-STD-704D. The units are built as fully hermetic thick film
hybrids in Interpoint’s MIL-STD-1772 certified facilities.
Continuous short circuit protection – using foldback current limit set
at approximately 125%.
Soft-start – at both turn-on and recovery after load fault conditions.
Remote sense – to provide automatic compensation for voltage
drops on output lines on single output models.
For more information, contact your Interpoint representative
listed in Section A5.
All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in
products or specifications without notice. SMHP120 is a trademark of Interpoint.
Copyright © 1999 Interpoint. All rights reserved.
B1-4
CASES
CASE U
Angled corner indicates pin one
1.505 max (38.23)
CASE U
TOP VIEW
(PIN SIDE)
See Figures 55 and 56 for dimensions
3.005 (76.33) max.
Note: Pins are shown for Case U1.
Materials
Header Cold Rolled Steel/Nickel/Gold
Cover Kovar/Nickel
Pins
#52 alloy/Gold
compression glass seal
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.2) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage
the device. Solder pins individually with heat
application not exceeding 300°C for 10 seconds
per pin.
FIGURE 54: CASE U MAXIMUM DIMENSIONS
B8-36
CASES
CASE U
TOP VIEW CASE U1
MFL Series and MHP Series: Screening – Standard, ES or 883
MFLHP Series, FMD270 EMI Filter, and FMD28-461SL EMI Filters:
Screening – Standard or ES
SMFL, SMFLHP, SMHP, and SSP Series; SFCS, and SFME EMI Filters:
Screening – Standard, Class H or K
HUM70 Module and LCM Module: Screening – Standard or ES
Seam Seal
Angled corner
indicates pin one.
0.23 (5.8) Lead Length
0.128 dia
(3.25).
1.505 (38.23) max.
0.040 dia
(1.02)
1.380 (35.05)
1.250 (31.75)
1
12
1.050 (26.67)
2
11
0.850 (21.59)
3
10
0.650 (16.51)
4
9
0.450 (11.43)
5
8
0.250 (6.35)
6
7
0.220 (5.59
0.050 (1.27)
0.000
0.400 (10.16) max.
2.880 (73.15)
3.005 (76.33) max.
2.750 (69.85)
0.000
0.120 (3.05)
0.250 (6.35)
0.120 (3.05)
0.000
FIGURE 55: CASE U1
B8-37
QA SCREENING
SPACE PRODUCTS
SPACE PRODUCTS
ELEMENT EVALUATION
TEST PERFORMED
(COMPONENT LEVEL)
STANDARD
CLASS
(O)
H
M/S
P M/S
P
CLASS
K
M/S
P
Element Electrical
yes
no
yes
yes yes
yes
Element Visual
no
no
yes
yes yes
yes
Internal Visual
no
no
yes
no
yes
no
Temperature Cycling
no
no
no
no
yes
yes
Constant Acceleration
no
no
no
no
yes
yes
Interim Electrical
no
no
no
no
yes
no
Burn-in
no
no
no
no
yes
no
Post Burn-in Electrical
no
no
no
no
yes
no
Steady State Life
no
no
no
no
yes
no
Voltage Conditioning /Aging
no
no
no
no
no
yes
Visual Inspection
no
no
no
no
no
yes
Final Electrical
no
no
yes
yes yes
yes
Wire Bond Evaluation*
no
no
yes
yes yes
yes
SEM
SLAM™/C-SAM:
Input capacitors only
(Add’l test, not req. by H or K)
no
no
no
no
yes
no
no
no
no
yes
no
yes
Notes
M/S
P
*
Active components (Microcircuit and Semiconductor Die)
Passive components
Not applicable to EMI filters that have no wirebonds
Definitions
Element Evaluation: Component testing/screening per MIL-STD-883 as determined by MIL-PRF-38534
SEM: Scanning Electron Microscopy
SLAM™: Scanning Laser Acoustic Microscopy
C-SAM: C - Mode Scanning Acoustic Microscopy
Applies to the following products:
SMFLHP Series
SMFL Series
SMHP Series (O&H only)
SMTR Series
SSP Series
SMHF Series
SMSA Series
SLH Series
SLIM Module
SFME120 EMI Filter
SFME28 EMI Filter
SFCS EMI Filter
SFMC EMI Filter
STF EMI Filter
C2-7
QA SCREENING
SPACE PRODUCTS
ENVIRONMENTAL SCREENING
TEST PERFORMED
(END ITEM LEVEL)
Non-destruct bond pull*
Method 2023
Pre-cap inspection
Method 2017, 2032
Temperature cycle
Method 1010, Cond. C
Constant acceleration
Method 2001, 3000 g
PIND Test
Method 2020, Cond. B
Radiography
Method 2012
Pre burn-in test
Burn-in, Method 1015, 125°C
96 hours
160 hours
2 x 160 hour (includes mid BI test)
Final electrical test
MIL-PRF-38534, Group A
Hermeticity test
Fine Leak,
Method 1014, Cond. A
Gross Leak,
Method 1014, Cond. C
Final visual inspection
Method 2009
STANDARD
(O)
CLASS
H
CLASS
K
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
yes
no
yes
no
yes
yes
yes
yes
no
no
no
yes
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Note
* Not applicable to EMI filters that have no wirebonds.
Applies to the following products:
SMFLHP Series
SMFL Series
SMHP Series (O&H only)
SMTR Series
SSP Series
C2-8
SMHF Series
SMSA Series
SLH Series
SLIM Module
SFME120 EMI Filter
SFME28 EMI Filter
SFCS EMI Filter
SFMC EMI Filter
STF EMI Filter
QA SCREENING
SPACE PRODUCTS
SPACE PRODUCTS
ELEMENT EVALUATION
TEST PERFORMED
(COMPONENT LEVEL)
STANDARD
CLASS
(O)
H
M/S
P M/S
P
CLASS
K
M/S
P
Element Electrical
yes
no
yes
yes yes
yes
Element Visual
no
no
yes
yes yes
yes
Internal Visual
no
no
yes
no
yes
no
Temperature Cycling
no
no
no
no
yes
yes
Constant Acceleration
no
no
no
no
yes
yes
Interim Electrical
no
no
no
no
yes
no
Burn-in
no
no
no
no
yes
no
Post Burn-in Electrical
no
no
no
no
yes
no
Steady State Life
no
no
no
no
yes
no
Voltage Conditioning /Aging
no
no
no
no
no
yes
Visual Inspection
no
no
no
no
no
yes
Final Electrical
no
no
yes
yes yes
yes
Wire Bond Evaluation*
no
no
yes
yes yes
yes
SEM
SLAM™/C-SAM:
Input capacitors only
(Add’l test, not req. by H or K)
no
no
no
no
yes
no
no
no
no
yes
no
yes
Notes
M/S
P
*
Active components (Microcircuit and Semiconductor Die)
Passive components
Not applicable to EMI filters that have no wirebonds
Definitions
Element Evaluation: Component testing/screening per MIL-STD-883 as determined by MIL-PRF-38534
SEM: Scanning Electron Microscopy
SLAM™: Scanning Laser Acoustic Microscopy
C-SAM: C - Mode Scanning Acoustic Microscopy
Applies to the following products:
SMFLHP Series
SMFL Series
SMHP Series (O&H only)
SMTR Series
SSP Series
SMHF Series
SMSA Series
SLH Series
SLIM Module
SFME120 EMI Filter
SFME28 EMI Filter
SFCS EMI Filter
SFMC EMI Filter
STF EMI Filter
C2-7
QA SCREENING
SPACE PRODUCTS
ENVIRONMENTAL SCREENING
TEST PERFORMED
(END ITEM LEVEL)
Non-destruct bond pull*
Method 2023
Pre-cap inspection
Method 2017, 2032
Temperature cycle
Method 1010, Cond. C
Constant acceleration
Method 2001, 3000 g
PIND Test
Method 2020, Cond. B
Radiography
Method 2012
Pre burn-in test
Burn-in, Method 1015, 125°C
96 hours
160 hours
2 x 160 hour (includes mid BI test)
Final electrical test
MIL-PRF-38534, Group A
Hermeticity test
Fine Leak,
Method 1014, Cond. A
Gross Leak,
Method 1014, Cond. C
Final visual inspection
Method 2009
STANDARD
(O)
CLASS
H
CLASS
K
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
yes
no
yes
no
yes
yes
yes
yes
no
no
no
yes
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Note
* Not applicable to EMI filters that have no wirebonds.
Applies to the following products:
SMFLHP Series
SMFL Series
SMHP Series (O&H only)
SMTR Series
SSP Series
C2-8
SMHF Series
SMSA Series
SLH Series
SLIM Module
SFME120 EMI Filter
SFME28 EMI Filter
SFCS EMI Filter
SFMC EMI Filter
STF EMI Filter
QA SCREENING
SPACE PRODUCTS
RADIATION HARDNESS LEVELS
FOR DC/DC CONVERTERS AND LINE INPUT MODULES1
PRODUCT LEVEL AVAILABILITY
RADIATION HARDNESS LEVELS
O: Standard, no radiation guarantee
For system evaluation, electrically
and mechanically comparable to
H and K level.
L: Radiation hardened – Tested lots
Up to 50 k Rads (Si) total dose
No SEU guarantee
R: Radiation hardened – Tested lots
Up to 100 k Rads (Si) total dose
SEU guarantee up to 40 MeV
L and R are referenced to
Assurance (RHA) levels.
ENVIRONMENTAL SCREENING LEVELS
STANDARD
CLASS
CLASS
(O)
H
K
OO
HO
Not
available
Not
available
HL
KL
Not
available
HR
KR
MIL-PRF-38534, appendix G, Radiation Hardness
Note
1. Interpoint’s EMI filters are designed exclusively with passive components providing
maximum tolerance for space environment requirements.
Applies to the following products:
SMFLHP Series (levels O and L only)
SMFL Series (levels O and L only)
SMTR Series
SSP Series
SMHF Series
SMSA Series
SLH Series
SLIM Series Modules
REPORTS: INCLUDED WITH PURCHASE OF PRODUCT HL, KL, HR, or KR
1.Radiation Susceptibility Analysis
2.Electrical/Thermal Stress Analysis and Derating Report
3.MTBF Report
4.FMEA Report
OO option: Select reports available as separate purchases.
C2-9