SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 D D D D D D DGG OR DL PACKAGE (TOP VIEW) Member of the Texas Instruments Widebus Family EPIC (Enhanced-Performance Implanted CMOS) Submicron Process ESD Protection Exceeds 2000 V Per MIL-STD-883, Method 3015; Exceeds 200 V Using Machine Model (C = 200 pF, R = 0) Latch-Up Performance Exceeds 250 mA Per JESD 17 Bus Hold on Data Inputs Eliminates the Need for External Pullup/Pulldown Resistors Package Options Include Plastic Shrink Small-Outline (DL) and Thin Shrink Small-Outline (DGG) Packages OEA OEB1 2B3 GND 2B2 2B1 VCC A1 A2 A3 GND A4 A5 A6 A7 A8 A9 GND A10 A11 A12 VCC 1B1 1B2 GND 1B3 NC SEL description This 12-bit to 24-bit registered bus exchanger is designed for 1.65-V to 3.6-V VCC operation. The SN74ALVCH16269 is used in applications in which two separate ports must be multiplexed onto, or demultiplexed from, a single port. The device is particularly suitable as an interface between synchronous DRAMs and high-speed microprocessors. 1 56 2 55 3 54 4 53 5 52 6 51 7 50 8 49 9 48 10 47 11 46 12 45 13 44 14 43 15 42 16 41 17 40 18 39 19 38 20 37 21 36 22 35 23 34 24 33 25 32 OEB2 CLKENA2 2B4 GND 2B5 2B6 VCC 2B7 2B8 2B9 GND 2B10 2B11 2B12 1B12 1B11 1B10 GND 1B9 1B8 1B7 VCC 1B6 1B5 GND 1B4 CLKENA1 CLK Data is stored in the internal B-port registers on 26 31 the low-to-high transition of the clock (CLK) input 27 30 when the appropriate clock-enable (CLKENA) 28 29 inputs are low. Proper control of these inputs allows two sequential 12-bit words to be NC – No internal connection presented as a 24-bit word on the B port. For data transfer in the B-to-A direction, a single storage register is provided. The select (SEL) line selects 1B or 2B data for the A outputs. The register on the A output permits the fastest possible data transfer, extending the period during which the data is valid on the bus. The control terminals are registered so that all transactions are synchronous with CLK. Data flow is controlled by the active-low output enables (OEA, OEB1, OEB2). To ensure the high-impedance state during power up or power down, a clock pulse should be applied as soon as possible, and OE should be tied to VCC through a pullup resistor; the minimum value of the resistor is determined by the current-sinking capability of the driver. Due to OE being routed through a register, the active state of the outputs cannot be determined before the arrival of the first clock pulse. Active bus-hold circuitry is provided to hold unused or floating data inputs at a valid logic level. The SN74ALVCH16269 is characterized for operation from –40°C to 85°C. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. EPIC and Widebus are trademarks of Texas Instruments Incorporated. Copyright 1999, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 Function Tables OUTPUT ENABLE OUTPUTS INPUTS CLK OEA OEB A 1B, 2B ↑ H H Z Z ↑ H L Z Active ↑ L H Active Z ↑ L L Active Active A-TO-B STORAGE (OEB = L) INPUTS OUTPUTS CLKENA1 CLKENA2 CLK A 1B 2B L H ↑ L L L H ↑ H H 2B0† 2B0† L L ↑ L L L L L ↑ H H H H L ↑ L H L ↑ H 1B0† 1B0† H L H H X X 1B0† 2B0† † Output level before the indicated steady-state input conditions were established B-TO-A STORAGE (OEA = L) INPUTS OUTPUT A CLK SEL 1B 2B X H X X X L X X ↑ H L X L ↑ H H X H ↑ L X L L ↑ L X H H A0† A0† † Output level before the indicated steady-state input conditions were established 2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 logic diagram (positive logic) CLK OEB1 29 C1 2 1D C1 OEB2 CLKENA1 CLKENA2 56 1D 30 55 C1 SEL OEA 28 1D 1 1D 1 of 12 Channels C1 G1 A1 8 C1 1 1D 23 1B1 1 CE C1 1D 6 2B1 CE C1 1D POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V Input voltage range, VI: Except I/O ports (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V I/O ports (see Notes 1 and 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V Output voltage range, VO (see Notes 1 and 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA Continuous output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous current through each VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA Package thermal impedance, θJA (see Note 3): DGG package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81°C/W DGV package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W DL package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. This value is limited to 4.6 V maximum. 3. The package thermal impedance is calculated in accordance with JESD 51. recommended operating conditions (see Note 4) VCC VIH Supply voltage VCC = 1.65 V to 1.95 V VCC = 2.3 V to 2.7 V High-level input voltage VCC = 2.7 V to 3.6 V VCC = 1.65 V to 1.95 V VIL VI VO IOH Low-level input voltage MIN MAX 1.65 3.6 2 0.35 × VCC 0.7 0 0 IOL Low level output current Low-level ∆t/∆v Input transition rise or fall rate VCC = 1.65 V VCC = 2.3 V VCC = 2.7 V VCC = 3 V V 0.8 Output voltage VCC = 2.7 V VCC = 3 V V 1.7 Input voltage High level output current High-level V 0.65 × VCC VCC = 2.3 V to 2.7 V VCC = 2.7 V to 3.6 V VCC = 1.65 V VCC = 2.3 V UNIT VCC VCC V V –4 –12 –12 mA –24 4 12 12 mA 24 10 ns/V TA Operating free-air temperature –40 85 °C NOTE 4: All unused control inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004. 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VCC 1.65 V to 3.6 V IOH = –100 µA IOH = –4 mA 1.65 V IOH = –6 mA VOH IOH = –12 mA IOH = –24 mA IOL = 100 µA Control inputs Cio A or B ports 1.7 2.7 V 2.2 3V 2.4 3V 2 2.3 V 0.4 2.3 V 0.7 2.7 V 0.4 3V 0.55 ±5 VI = 0.58 V VI = 1.07 V 1.65 V 25 1.65 V –25 VI = 0.7 V VI = 1.7 V 2.3 V 45 2.3 V –45 VI = 0.8 V VI = 2 V 3V 75 3V –75 IO = 0 Other inputs at VCC or GND V µA µA 3.6 V ±500 3.6 V ±10 µA 3.6 V 40 µA 750 µA 3 V to 3.6 V VI = VCC or GND VO = VCC or GND UNIT V 3.6 V VI = VCC or GND, One input at VCC – 0.6 V, ∆ICC Ci 2 2.3 V 0.2 VI = 0 to 3.6 V‡ VO = VCC or GND IOZ§ ICC 2.3 V 0.45 IOL = 24 mA VI = VCC or GND II(hold) ( ) MAX VCC–0.2 1.2 1.65 V IOL = 12 mA II TYP† 1.65 V to 3.6 V IOL = 4 mA IOL = 6 mA VOL MIN 3.3 V 3.5 3.3 V 9 pF pF † All typical values are at VCC = 3.3 V, TA = 25°C. ‡ This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to another. § For I/O ports, the parameter IOZ includes the input leakage current. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5 SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 timing requirements over recommended operating free-air temperature range (unless otherwise noted) (see Figures 1 through 3) VCC = 1.8 V MIN fclock tw tsu th Clock frequency Hold time MIN MAX VCC = 2.7 V MIN 135 MAX VCC = 3.3 V ± 0.3 V MIN 135 3.3 3.3 3.3 A data before CLK↑ † 2 2 1.7 B data before CLK↑ † 2.2 2.1 1.8 SEL before CLK↑ † 1.6 1.6 1.3 CLKENA1 or CLKENA2 before CLK↑ † 1 1.2 0.9 OE before CLK↑ † 1.5 1.6 1.3 A data after CLK↑ † 0.7 0.6 0.6 B data after CLK↑ † 0.7 0.6 0.6 SEL after CLK↑ † 1.1 0.7 0.7 CLKENA1 or CLKENA2 after CLK↑ † 1 0.8 1.1 OE after CLK↑ † 0.8 0.8 0.8 UNIT MAX 135 † Pulse duration, CLK high or low Setup time MAX † VCC = 2.5 V ± 0.2 V MHz ns ns ns † This information was not available at the time of publication. switching characteristics over recommended operating free-air temperature range (unless otherwise noted) (see Figures 1 through 3) PARAMETER FROM (INPUT) VCC = 1.8 V TO (OUTPUT) MIN † fmax tpd d CLK ten CLK tdis di CLK MAX VCC = 2.5 V ± 0.2 V MIN MAX 135 VCC = 2.7 V MIN MAX 135 VCC = 3.3 V ± 0.3 V MIN UNIT MAX 135 MHz B † 1 8.2 7.3 1 6.2 A † 1 6.4 5.8 1 5 B † 1 7.9 6.7 1 6.1 A † 1 7.6 6.2 1 5.9 B † 1 8.1 6.9 1 6.1 A † 1 7.5 6.8 1 5.6 ns ns ns † This information was not available at the time of publication. operating characteristics, TA = 25°C PARAMETER Cpd d Power dissipation capacitance per exchanger TEST CONDITIONS VCC = 1.8 V TYP All outputs enabled All outputs disabled CL = 50 pF, pF f = 10 MHz † This information was not available at the time of publication. 6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 VCC = 2.5 V TYP VCC = 3.3 V TYP † 87 120 † 80.5 118 UNIT pF SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 PARAMETER MEASUREMENT INFORMATION VCC = 1.8 V 2 × VCC S1 1 kΩ From Output Under Test Open GND CL = 30 pF (see Note A) 1 kΩ TEST S1 tpd tPLZ/tPZL tPHZ/tPZH Open 2 × VCC GND LOAD CIRCUIT tw VCC Timing Input VCC/2 VCC/2 VCC/2 0V VOLTAGE WAVEFORMS SETUP AND HOLD TIMES VCC/2 VCC/2 0V tPLH Output Control (low-level enabling) tPLZ VCC VCC/2 tPZH VOH VCC/2 VOL VCC/2 0V Output Waveform 1 S1 at 2 × VCC (see Note B) tPHL VCC/2 VCC VCC/2 tPZL VCC Input VOLTAGE WAVEFORMS PULSE DURATION th VCC Data Input VCC/2 0V 0V tsu Output VCC VCC/2 Input Output Waveform 2 S1 at GND (see Note B) VOL + 0.15 V VOL tPHZ VCC/2 VOH VOH – 0.15 V 0V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2 ns, tf ≤ 2 ns. D. The outputs are measured one at a time with one transition per measurement. E. tPLZ and tPHZ are the same as tdis. F. tPZL and tPZH are the same as ten. G. tPLH and tPHL are the same as tpd. Figure 1. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7 SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 PARAMETER MEASUREMENT INFORMATION VCC = 2.5 V ± 0.2 V 2 × VCC S1 500 Ω From Output Under Test Open GND CL = 30 pF (see Note A) 500 Ω TEST S1 tpd tPLZ/tPZL tPHZ/tPZH Open 2 × VCC GND LOAD CIRCUIT tw VCC Timing Input VCC/2 VCC/2 VCC/2 0V VOLTAGE WAVEFORMS SETUP AND HOLD TIMES VCC/2 VCC/2 0V tPLH Output Control (low-level enabling) tPLZ VCC VCC/2 tPZH VOH VCC/2 VOL VCC/2 0V Output Waveform 1 S1 at 2 × VCC (see Note B) tPHL VCC/2 VCC VCC/2 tPZL VCC Input VOLTAGE WAVEFORMS PULSE DURATION th VCC Data Input VCC/2 0V 0V tsu Output VCC VCC/2 Input Output Waveform 2 S1 at GND (see Note B) VOL + 0.15 V VOL tPHZ VCC/2 VOH VOH – 0.15 V 0V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2 ns, tf ≤ 2 ns. D. The outputs are measured one at a time with one transition per measurement. E. tPLZ and tPHZ are the same as tdis. F. tPZL and tPZH are the same as ten. G. tPLH and tPHL are the same as tpd. Figure 2. Load Circuit and Voltage Waveforms 8 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 SN74ALVCH16269 12-BIT TO 24-BIT REGISTERED BUS EXCHANGER WITH 3-STATE OUTPUTS SCES019I – JULY 1995 – REVISED SEPTEMBER 1999 PARAMETER MEASUREMENT INFORMATION VCC = 2.7 V AND 3.3 V ± 0.3 V 6V S1 500 Ω From Output Under Test Open GND CL = 50 pF (see Note A) 500 Ω TEST S1 tpd tPLZ/tPZL tPHZ/tPZH Open 6V GND LOAD CIRCUIT tw 2.7 V 2.7 V Timing Input 1.5 V 1.5 V 1.5 V 0V VOLTAGE WAVEFORMS SETUP AND HOLD TIMES 1.5 V 1.5 V 0V tPLH Output Control (low-level enabling) 1.5 V 0V Output Waveform 1 S1 at 6 V (see Note B) tPLZ 3V 1.5 V VOL + 0.3 V tPZH tPHL VOH 1.5 V 2.7 V 1.5 V tPZL 2.7 V Output VOLTAGE WAVEFORMS PULSE DURATION th 2.7 V Data Input 1.5 V 0V 0V tsu Input 1.5 V Input 1.5 V VOL Output Waveform 2 S1 at GND (see Note B) VOL tPHZ 1.5 V VOH VOH – 0.3 V 0V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns. D. The outputs are measured one at a time with one transition per measurement. E. tPLZ and tPHZ are the same as tdis. F. tPZL and tPZH are the same as ten. G. tPLH and tPHL are the same as tpd. Figure 3. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 9 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1999, Texas Instruments Incorporated