MA-COM SR4D4012

General Purpose Relays
Safety Relay SR4 D/M
I
4 pole safety relay with either
2 NO+2 NC or 3 NO+1 NC contacts
I
Forcibly guided contacts according to EN 50205
I
Rated current 8 A
I
Very small outlines
I
RoHS compliant (Directive 2002/95/EC)
as per product date code 0407
Applications
Emergency shut-off, machine control, elevator and escalator
control, light barrier control
F0244-A
Approvals
V REG.-Nr. 40005334, Z E214024, T 968/EL 230.00/03
Technical data of approved types on request
Contact data
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Utilization class (AC-15) acc. IEC 60947-5-1
NO contact
NC contact
Contact material
Minimum contact load
Contact resistance
3 N/O contacts and 1 N/C contact
or
2 N/O contacts and 2 N/C contacts
single contact, forcibly guided
type A according to EN 50205
micro disconnection
8A
240/400 VAC
2000 VA
Ie 3 A / Ue 250 VAC (inrush 30 A)
Ie 1.5 A / Ue 250 VAC (inrush 15 A)
AgSnO2
10 mA / 5 V
w 100 mOhm / 1 A / 24 VDC
w 20 Ohm / 10 mA / 5 VDC
Mechanical endurance
10x106 cycles
Rated frequency of operation with / without load
6 min-1 / 150 min-1
Coil data
Rated coil voltage range DC coil
Coil power DC coil
Operative range
5...110 VDC
appr. 800 mW
2
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
005
5
3.8
0.5
31+10%
806
006
6
4.5
0.6
45+10%
800
009
9
6.8
0.9
101+10%
802
012
12
9.0
1.2
180+10%
800
015
15
11.3
1.5
281+10%
801
018
18
13.5
1.8
405+10%
800
021
21
15.8
2.1
551+10%
800
024
24
18.0
2.4
720+10%
800
036
36
27.0
3.6
1620+10%
800
040
40
30.0
4.0
2000+10%
800
048
48
36.0
4.8
2880+10%
800
060
60
45.0
6.0
4500+10%
800
085
85
63.8
8.5
9031+10%
800
110
110
82.5
11.0
15125+10%
800
All figures are given for coil without preenergization, at ambient temperature +23°C
1
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
Safety Relay SR4 D/M (Continued)
PCB layout / terminal assignment
Other coil voltages on request
Bottom view on solder pins
Insulation
> 100x106 Ohm
4000 Vrms
1500 Vrms
2500 Vrms
W 10 / 10 mm
W 3 / 3.5 mm
W 1.3 / 3.5 mm
W IIIa
CTI 250
Insulation resistance coil-contact circuit
Dielectric strength coil-contact circuit
open contact circuit
adjacent contact circuits
Clearance / creepage coil-contact circuit
adjacent contact circuits
adjacent contact circuits (UL840)
Material group of insulation parts
Tracking index of relay base
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
open contact circuit
adjacent contact circuits
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
Insulation to EN 50178
Type of insulation coil-contact circuit
adjacent contact circuits
S0413-BC
2 NO and 2 NC contacts
reinforced
functional
basic
250 V
2
230/400 V
III
S0413-BB
reinforced
basic
3 NO and 1 NC contacts
Other data
RoHS - Directive 2002/95/EC
compliant as per product date code 0407
Ambient temperature range
-25...+70°C
Vibration resistance (function) NO / NC contact
> 10 / 2 g, 10....200 Hz
Shock resistance (function) NO / NC contact
> 10 / 2 g, 11 ms half sine
Category of protection
RT III 1)
Resistance to soldering heat
260°C / 5 s
Relay weight
16 g
Packaging unit
10 pcs
1)
S0413-BA
please contact technical support for washing parameters
Dimensions
S0412-BH
Product key
S R 4
4
Type
Contact configuration
D 2 NO + 2 NC contacts
M 3 NO + 1 NC contacts
Contact material
4 AgSnO2
Coil
Coil code = rated coil voltage (e.g. 024=24 VDC)
Other types on request
2
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
Safety Relay SR4 D/M (Continued)
Product key
SR4D4005
SR4D4006
SR4D4009
SR4D4012
SR4D4018
SR4D4021
SR4D4024
SR4D4036
SR4D4040
SR4D4048
SR4D4060
SR4D4085
SR4D4110
SR4M4005
SR4M4006
SR4M4009
SR4M4012
SR4M4018
SR4M4021
SR4M4024
SR4M4036
SR4M4040
SR4M4048
SR4M4060
SR4M4085
SR4M4110
Type
4 pole
safety relay
Contact configuration
2 NO + 2 NC
contacts
Contact material
AgSnO2
3 NO + 1 NC
contacts
Coil
5 VDC
6 VDC
9 VDC
12 VDC
18 VDC
21 VDC
24 VDC
36 VDC
40 VDC
48 VDC
60 VDC
85 VDC
110 VDC
5 VDC
6 VDC
9 VDC
12 VDC
18 VDC
21 VDC
24 VDC
36 VDC
40 VDC
48 VDC
60 VDC
85 VDC
110 VDC
Part number
7-1415054-1
8-1415054-1
9-1415054-1
0-1415055-1
1-1415055-1
2-1415055-1
3-1415055-1
4-1415055-1
5-1415055-1
6-1415055-1
7-1415055-1
8-1415055-1
9-1415055-1
5-1415053-1
6-1415053-1
7-1415053-1
8-1415053-1
9-1415053-1
0-1415054-1
4-1415053-1
1-1415054-1
2-1415054-1
3-1415054-1
4-1415054-1
5-1415054-1
6-1415054-1
3
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.