POWER-SYSTEMS SRS-1205-1

DC-DC Converter UNIT
SR Series (0,5W TO 1W REGULATED DC-DC CONVERTER)
FEATURES
z
z
z
1000VDC ISOLATION
EFFICIENCY UP TO 72%
INTERNAL SMD TECHNOLOGY
LOW COST
NO HEATSINK REQUIRED
UP TO 1W REGULATED OUTPUT
POWER
DUAL IN LINE PACKAGE
100% BURNED IN
MTBF > 2,000,000 HOURS
z
OUTPUT SPECIFICATIONS
z
z
z
z
z
z
z
Voltage Setpoint Accuracy
+/-2% max
Temperature Coefficient
+/-0.03%/ OC
Ripple & Noise (20MHz
INPUT SPECIFICATIONS
Input Voltage Range
Input Filter
+/-10% max
Capacitor Type
100mVp-p max
BW)
Line Regulation1
Load Regulation
+/-0.5% max
2
+/-0.5% max
Short Circuit Protection
Current limit Protection
Short Circuit Restart
z
Automatic
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
z
GENERAL SPECIFICATIONS
Efficiency
50% min
3
Isolation Voltage
1000 VDC min
Isolation Resistance
9
10 ohms min
-25 OC to +71 OC
Switching Frequency
50 KHz min
-55 OC to +125 OC
Isolation Capacitance
80pF max
Free-Air Convection
MTBF
Weight
ALL SPECIFICATIONS TYPICAL AT NOMINAL
Case Material
LINE,
Case Size
FULL
LOAD
,
AND
25
O
C
UNLESS
2,000,000 Hours
3.1g Typ
Non-Conductive Plastic
22.6mm*9.9mm*8.4mm
OTHERWISE NOTED.
1
High Line to Low Line.
2
Load Regulation is for output load current change from 20% to 100%.
3
For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
SR Series (0,5W TO 1W REGULATED DC-DC CONVERTER)
z SELECTION GUIDE
0.5W-1W OUTPUT
MODEL
NUMBER
INPUT
OUTPUT
OUTPUT
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA) EFF ISOLATION
FULL
NO
LOAD
LOAD
(%)
(VDC)
OUTPUT
POWER
(Watt)
SRS-0505-1
4.5-5.5
5
100
161
12
62
1000
0.5W
SRS-0509-1
4.5-5.5
9
56
175
11
57
1000
0.5W
SRS-0512-1
4.5-5.5
12
42
161
11
62
1000
0.5W
SRS-0515-1
4.5-5.5
15
34
173
37
58
1000
0.5W
SRS-1205-1
10.8-13.2
5
100
62
7
67
1000
0.5W
SRS-1209-1
10.8-13.2
9
56
66
5
63
1000
0.5W
SRS-1212-1
10.8-13.2
12
42
64
5
65
1000
0.5W
SRS-1215-1
10.8-13.2
15
34
64
5
65
1000
0.5W
SRS-2405-1
21.6-26.4
5
100
32
4
65
1000
0.5W
SRS-2409-1
21.6-26.4
9
56
32
3
65
1000
0.5W
SRS-2412-1
21.6-26.4
12
42
36
9
58
1000
0.5W
SRS-2415-1
21.6-26.4
15
34
30
3
70
1000
0.5W
SRS-4805-1
43.2-52.8
5
100
18
2
58
1000
0.5W
SRS-4809-1
43.2-52.8
9
56
18
2
58
1000
0.5W
SRS-4812-1
43.2-52.8
12
42
16
2
65
1000
0.5W
SRS-4815-1
43.2-52.8
15
34
16
2
65
1000
0.5W
SRS-0505-2
4.5-5.5
5
200
322
23
62
1000
1W
SRS-0509-2
4.5-5.5
9
111
333
22
60
1000
1W
SRS-0512-2
4.5-5.5
12
84
322
22
62
1000
1W
SRS-0515-2
4.5-5.5
15
67
322
21
62
1000
1W
SRS-1205-2
10.8-13.2
5
200
124
12
67
1000
1W
SRS-1209-2
10.8-13.2
9
111
134
13
62
1000
1W
SRS-1212-2
10.8-13.2
12
84
130
11
64
1000
1W
SRS-1215-2
10.8-13.2
15
67
130
11
64
1000
1W
SRS-2405-2
21.6-26.4
5
200
61
7
68
1000
1W
SRS-2409-2
21.6-26.4
9
111
64
6
65
1000
1W
SRS-2412-2
21.6-26.4
12
84
60
6
70
1000
1W
SRS-2415-2
21.6-26.4
15
67
60
6
70
1000
1W
SRS-4805-2
43.2-52.8
5
200
30
4
70
1000
1W
SRS-4809-2
43.2-52.8
9
111
30
3
70
1000
1W
SRS-4812-2
43.2-52.8
12
84
29
3
72
1000
1W
SRS-4815-2
43.2-52.8
15
67
29
3
72
1000
1W
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
SR Series (0,5W TO 1W REGULATED DC-DC CONVERTER)
z MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
www.Power-Systems.de
Page: 3 / 5
PIN
SINGLE
1 & 16
+Vin
6 & 11
-Vout
7 & 10
+Vout
8&9
-Vin
Version: 4-Oct-02
DC-DC Converter UNIT
SR Series (0,5W TO 1W REGULATED DC-DC CONVERTER)
z SIMPLIFIED SCHEMATIC
z TYPICAL
APPLICATIONS
REGULATOR
+Vin
INPUT
+Vout
+Vin
OSCILLATOR
DRIVER
+Vout
LOAD
DC-DC
CONVERTER
-Vout
-Vin
OUTPUT
-Vin
-Vout
z TYPICAL PERFORMANCE CUREVES
DERATING CURVE
EFFICIENCY VS LOAD
EFFICIENCY(%)
OUTPUT POWER(W)
1.2
0.9
SAFE
OPERATING
AREA
0.6
0.3
0.0
-25
0
25
50
70
80.0
60.0
40.0
20.0
0.0
100
0
TA(degree C)
20
40
60
80
100
% OF RATED LOAD(%)
SR SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the SR series.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 250KHz is required.
External output capacitance is not required for operation, however it is recommended that 10uF
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.
Additional output capacitance may be added for increased filtering, but should not exceed 100uF.
www.Power-Systems.de
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
SR Series (0,5W TO 1W REGULATED DC-DC CONVERTER)
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
74360 Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02