HONEYWELL SS311PT

SS311PT/SS411P
Bipolar Hall-effect Digital
Position Sensors with Built-in
Pull-up Resistor
DESCRIPTION
The 2.7 Vdc to 7 Vdc supply voltage range allows this device
The SS311PT/SS411P sensors are small, versatile digital Hall-
to be used in low voltage applications. The S311PT’s very
effect devices that are operated by the magnetic field from a
small size requires less PCB (printed circuit board) space,
permanent magnet or an electromagnet, designed to respond
allowing it to be used in smaller assemblies.
to alternating North and South poles.
These sensors are available in two package styles: the
These bipolar sensors have enhanced sensitivity which allows
SS311PT in the subminiature SOT-23 surface mount package
for the use of smaller, often less expensive magnets. The
and the SS411P in the leaded, flat TO-92-style package.
internal pull-up resistor often eliminates the need for external
components, further helping to reduce system cost. These
economical bipolar sensors are suited for many simple, highvolume, cost-sensitive, rotary sensing applications.
FEATURES
•
Subminiature, SOT-23 surface mount package (SS311PT)
supplied on tape and reel allows for a compact design with
automated component placement, helping to reduce
manufacturing costs
•
Small, leaded, flat TO-92 package (SS411P) often allows
for more space on the PCB
•
Sensitive, bipolar magnetics respond to alternating North
and South poles, making these products suited for speed
sensing and RPM measurement
•
Built-in pull-up resistor can easily interface with common
electronic circuits without adding external components,
helping to reduce total system cost
•
RoHS-compliant materials meet Directive 002/95/EC
The SS311PT is available on tape and reel (3000 units per
reel); the SS411P is available in a bulk package (1000 units
per bag).
POTENTIAL APPLICATIONS
Transportation:
•
Speed and RPM (revolutions per minute) sensing
•
Tachometer, counter pickup
•
Motor and fan control
•
Brushless dc motor control
Industrial and Commercial:
•
Speed and RPM (revolutions per minute) sensing
•
Tachometer, counter pickup
•
Flow-rate sensing
•
Brushless dc (direct current) motor commutation
•
Motor and fan control
•
Robotics control
SS311PT/SS411P
Table 1. SS311PT/SS411P Specifications (At 2.7 Vdc to 7 Vdc supply, 4 mA load, TA = -40 ºC to 150 ºC [-40 ºF to 302 ºF]
Characteristic
Supply voltage
Supply current
Output current
Vsat
Output leakage current
Output rise time
Output fall time
Thermal resistance:
SS311PT
SS411P
Operate
Release
Differential
Operating temperature
Storage temperature
Condition
-40 °C to 150 °C [-40 °F to 302 °F]
gauss <-140, Vs = 5 V, 25 °C [77°F]
-40 °C to 150 °C [-40 °F to 302 °F]
–
gauss >140
gauss <-140
25 °C [77 °F]
–
–
-40 °C to 150 °C [-40 °F to 302 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
–
–
Minimum
2.7
–
–
–
–
–
–
–
Typical
5.0
5.5
–
–
–
–
–
–
Maximum
7.0
–
14
4.0
0.4
10
1.5
1.5
Unit
Vdc
–
–
-30
-140
40
-40 [-40]
-40 [-40]
303
233
55
-55
–
–
–
–
–
140
30
–
150 [302]
150 [302]
°C/W
mA
mA
V
µA
µs
gauss
gauss
gauss
°C [°F]
°C [°F]
NOTICE
Bipolar Hall-effect sensors may have an initial output in either the ON or OFF state if powered up with an applied magnetic field in
the differential zone (applied magnetic field >Brp and <Bop). Honeywell recommends allowing 10 µs for output voltage to stabilize
after supply voltage has reached 5 Vdc.
1
Table 2. SS311PT/SS411P Absolute Maximum Ratings
Characteristic
Minimum
Typical
Maximum
Unit
Supply voltage
-0.5
–
7.0
Vdc
Applied output voltage
-0.5
–
7.0
Vdc
Output current
–
–
8.0
mA
Magnetic flux
–
–
no limit
gauss
Note 1: The magnetic field strength (gauss) required to cause the switch to change state (operate and release) will be as specified
in the magnetic characteristics. To test the switch against the specified magnetic characteristics, the switch must be placed in a
uniform magnetic field.
NOTICE
Absolute maximum ratings are the extreme limits that the device will withstand without
damage to the device. However, the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended operating conditions) are
approached, nor will the device necessarily operate at absolute maximum ratings.
Figure 1. Current Sinking Output Block Diagram
2
www.honeywell.com/sensing
Bipolar Hall-Effect Digital Position Sensors
Figure 2. SS311PT Mounting/Tape and Reel Dimensions (For reference only. mm/[in])
Figure 3. SS411P Mounting Dimensions (For reference only. mm/[in])
Honeywell Sensing and Control
3
Order Guide
Catalog Listing
SS311PT
SS411P
Description
Bipolar Hall-effect digital position sensor with built-in pull-up resistor, SOT-23 package, tape and reel
packaging (3000 units per reel)
Bipolar Hall-effect digital position sensor with built-in pull-up resistor, flat TO-92 package, bulk packaging
(1000 units per bag)
WARNING
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
• Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
005914-1-EN IL50 GLO Printed in USA
October 2009
© 2009 Honeywell International Inc. All rights reserved.