SS340RT and SS440R Series Unipolar Hall-Effect Digital Position Sensors DESCRIPTION These sensors are available in two package styles. The The SS340RT Series and SS440R Series sensors are small, SS340RT Series is available in the miniature SOT-23 surface versatile digital Hall-effect devices that are operated by the mount package; the SS440R is available in the leaded, flat TO- magnetic field from a permanent magnet or an electromagnet. 92-style package. The SS340RT’s small size requires less PC They are designed to respond to a single pole: North board space, allowing it to be used in smaller assemblies. Its (SS340RT Series) or South (SS440R Series). 3 V capability allows for use in low voltage applications, promoting energy efficiency. These unipolar sensors are supplied in three different magnetic sensitivities to meet a wide range of potential applications. The The SS340RT Series is available on tape and reel (3000 units SS341RT and SS441R offer the highest sensitivity, with a per reel); the SS440R Series is available in a bulk package typical operating point of 85 G at 25 °C [77 °F]; the SS343RT (1000 units per bag). and SS443R offer medium sensitivity with 125 G typical at 25 °C [77 °F]; the SS349RT and SS449R offer the lowest sensitivity, requiring 350 G typical to operate at 25 °C [77 °F]. FEATURES/BENEFITS • Subminiature package size (SS340RT Series) supplied on tape and reel allows for a compact design with automated component placement, helping to reduce manufacturing costs • Simple activation from a single pole and multiple magnetic sensitivities (high, medium and low) make this product suitable in a variety of potential motion control, lid closure detection, and displacement sensing applications • Low voltage 3 V capability helps reduce power consumption • Built-in reverse polarity protection protects the device from potential damage during installation • Thermally balanced integrated circuit provides for stable operation over a wide temperature range, from -40 °C to 150 °C [-40 °F to 302 °F] • RoHS-compliant materials meet Directive 2002/95/EC POTENTIAL APPLICATIONS • Door or lid closure detection • Speed and RPM (revolutions per minute) sensing in fitness equipment • Flow rate sensing in industrial processes, appliances, or water softeners • Damper or valve position control in industrial, HVAC or residential or commercial applications • Robotic control (cylinder position monitoring) • Float-based fluid level sensing • Displacement sensor in hospital beds or medical equipment • Medication bin monitor on portable drug carts • Printer head position sensing SS340RT and SS440R Series Table 1. SS340RT and SS440R Series Specifications (At Vs=3.0 to 24 Vdc, 20 mA load, TA = -40 ºC to 150 ºC [-40 ºF to 257 ºF]) Characteristic 1 Supply voltage: SS440R Series SS340RT Series SS340RT Series Supply current Vsat Output leakage current Output switching time: rise fall Thermal resistance: SS440R Series SS340RT Series Operate: SS341RT/SS441R SS343RT/SS443R SS349RT/SS449R Release: SS341RT/SS441R SS343RT/SS443R SS349RT/SS449R Differential: SS341RT/SS441R SS343RT/SS443R SS349RT/SS449R Operating temperature Storage temperature Condition Minimum Typical Maximum -40 °C to 150 °C [-40 °F to 302 °F] -40 °C to 125 °C [-40 °F to 257 °F] 150 °C [302 °F] Vsupply = 5 V at 25 °C [77 °F] Vsupply = 3 V at 25 °C [77 °F] at 20 mA, gauss >Bop gauss >Bop 3 3 3 – – – – – – – – 4 3.5 – – – 24 24 12 6 5 8 0.4 10 Vsupply = 12 V at 25 °C [77 °F], RL =1.6 kOhm, CL = 20 pF – – – – 1.5 1.5 µs – – 233 303 – °C/W 35 45 240 85 125 350 135 205 460 10 40 135 50 90 250 120 180 370 5 5 30 -40 [-40] -40 [-40] 35 35 100 – – 80 120 170 150 [302] 150 [302] – – – – – Unit Vdc mA Vdc µA gauss gauss gauss °C [°F] °C [°F] Note 1. See Figure 1. 1 Table 2. SS340RT and SS440R Series Absolute Maximum Ratings Characteristic Minimum Typical Supply voltage -28.0 – Applied output voltage -0.5 – Output current – – Magnetic flux – – Maximum 28.0 28.0 20 no limit Unit V V mA gauss Note 1: The magnetic field strength (gauss) required to cause the switch to change state (operate and release) will be as specified in the magnetic characteristics. To test the switch against the specified magnetic characteristics, the switch must be placed in a uniform magnetic field. NOTICE Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum ratings. Figure 1. SS340RT Series Rated Supply Voltage 2 www.honeywell.com/sensing Figure 2. Current Sinking Output Block Diagram Unipolar Hall-Effect Digital Position Sensors Figure 3. Wiring Diagrams Figure 4. SS340RT Series Mounting/Tape and Reel Dimensions (For reference only. mm/[in]) Figure 5. SS440R Series Mounting Dimensions (For reference only. mm/[in]) Honeywell Sensing and Control 3 Order Guide Catalog Listing SS341RT SS343RT SS349RT SS441R SS443R SS449R Description SS340RT Series, unipolar, Hall-effect digital position sensor, high sensitivity, SOT-23 package, tape and reel packaging (3000 units per reel) SS340RT Series, unipolar, Hall-effect digital position sensor, medium sensitivity, SOT-23 package, tape and reel packaging (3000 units per reel) SS340RT Series, unipolar, Hall-effect digital position sensor, low sensitivity, SOT-23 package, tape and reel packaging (3000 units per reel) SS440R Series, unipolar, Hall-effect digital position sensor, high sensitivity, flat TO-92 package, bulk packaging (1000 units per bag) SS440R Series, unipolar, Hall-effect digital position sensor, medium sensitivity, flat TO-92 package, bulk packaging (1000 units per bag) SS440R Series, unipolar, Hall-effect digital position sensor, low sensitivity, flat TO-92 package, bulk packaging (1000 units per bag) WARNING WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. MISUSE OF DOCUMENTATION • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: [email protected] Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com/sensing 005909-1-EN IL50 GLO Printed in USA September 2009 © 2009 Honeywell International Inc. All rights reserved.