FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD SST89E/V58 / 54 / 52RD2/RD FlashFlex51 MCU Data Sheet FEATURES: • 8-bit 8051-Compatible Microcontroller (MCU) with Embedded SuperFlash Memory – Fully Software Compatible – Development Toolset Compatible – Pin-For-Pin Package Compatible • SST89E5xRD2 Operation – 0 to 40 MHz at 5V • SST89V5xRD2 Operation – 0 to 33 MHz at 3V • 1 KByte Internal RAM • Dual Block SuperFlash EEPROM – 16/32 KByte primary block + 8 KByte secondary block (128-Byte sector size for both blocks) – Individual Block Security Lock with SoftLock – Concurrent Operation during In-Application Programming (IAP) – Memory Overlay for Interrupt Support during IAP • Support External Address Range up to 64 KByte of Program and Data Memory • Three High-Current Drive Ports (16 mA each) • Three 16-bit Timers/Counters • Full-Duplex, Enhanced UART – Framing Error Detection – Automatic Address Recognition • Ten Interrupt Sources at 4 Priority Levels – Four External Interrupt Inputs • Programmable Watchdog Timer (WDT) • Programmable Counter Array (PCA) • Four 8-bit I/O Ports (32 I/O Pins) and One 4-bit Port • Second DPTR register • Low EMI Mode (Inhibit ALE) • SPI Serial Interface • Standard 12 Clocks per cycle, the device has an option to double the speed to 6 clocks per cycle. • TTL- and CMOS-Compatible Logic Levels • Brown-out Detection • Low Power Modes – Power-down Mode with External Interrupt Wake-up – Idle Mode • Temperature Ranges: – Commercial (0°C to +70°C) – Industrial (-40°C to +85°C) • Packages Available – 40-contact WQFN (Port 4 feature not available) – 44-lead PLCC – 40-pin PDIP (Port 4 feature not available) – 44-lead TQFP • All non-Pb (lead-free) devices are RoHS compliant PRODUCT DESCRIPTION The SST89E5xRD2/RD and SST89V5xRD2/RD are members of the FlashFlex family of 8-bit microcontroller products designed and manufactured with SST’s patented and proprietary SuperFlash CMOS semiconductor process technology. The split-gate cell design and thick-oxide tunneling injector offer significant cost and reliability benefits for SST’s customers. The devices use the 8051 instruction set and are pin-for-pin compatible with standard 8051 microcontroller devices. The devices come with 24/40 KByte of on-chip flash EEPROM program memory which is partitioned into 2 independent program memory blocks. The primary Block 0 occupies 16/32 KByte of internal program memory space and the secondary Block 1 occupies 8 KByte of internal program memory space. The 8-KByte secondary block can be mapped to the lowest location of the 16/32 KByte address space; it can also be hidden from the program counter and used as an independent EEPROM-like data memory. ©2007 Silicon Storage Technology, Inc. S71255-08-000 1/07 1 In addition to the 24/40 KByte of EEPROM program memory on-chip and 1024 x8 bits of on-chip RAM, the devices can address up to 64 KByte of external program memory and up to 64 KByte of external RAM. The flash memory blocks can be programmed via a standard 87C5x OTP EPROM programmer fitted with a special adapter and the firmware for SST’s devices. During poweron reset, the devices can be configured as either a slave to an external host for source code storage or a master to an external host for an in-application programming (IAP) operation. The devices are designed to be programmed in-system and in-application on the printed circuit board for maximum flexibility. The devices are pre-programmed with an example of the bootstrap loader in the memory, demonstrating the initial user program code loading or subsequent user code updating via the IAP operation. The sample bootstrap loader is available for the user’s reference and convenience only; SST does not guarantee its functionality or usefulness. Chip-Erase or Block-Erase operations will erase the pre-programmed sample code. The SST logo, SuperFlash, and FlashFlex are registered trademarks of Silicon Storage Technology, Inc. These specifications are subject to change without notice. FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE OF CONTENTS FEATURES: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 LIST OF TABLES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.0 FUNCTIONAL BLOCKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.0 PIN ASSIGNMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1 Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3.0 MEMORY ORGANIZATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.1 Program Flash Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.2 Program Memory Block Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.3 Data RAM Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.4 Expanded Data RAM Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.5 Dual Data Pointers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.6 Special Function Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.0 FLASH MEMORY PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4.1 Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4.2 In-Application Programming Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5.0 TIMERS/COUNTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.1 Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.2 Timer Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.3 Programmable Clock-Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 6.0 SERIAL I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 6.1 Full-Duplex, Enhanced UART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 6.2 Serial Peripheral Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 7.0 WATCHDOG TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 8.0 PROGRAMMABLE COUNTER ARRAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 8.1 PCA Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 8.2 PCA Timer/Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 8.3 Compare/Capture Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 9.0 SECURITY LOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 9.1 Hard Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 ©2007 Silicon Storage Technology, Inc. S71255-08-000 2 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 9.2 SoftLock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 9.3 Security Lock Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 9.4 Read Operation Under Lock Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 10.0 RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 10.1 Power-on Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 10.2 Software Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 10.3 Brown-out Detection Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 11.0 INTERRUPTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 11.1 Interrupt Priority and Polling Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 12.0 POWER-SAVING MODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 12.1 Idle Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 12.2 Power-down Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 13.0 SYSTEM CLOCK AND CLOCK OPTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 13.1 Clock Input Options and Recommended Capacitor Values for Oscillator . . . . . . . . . . . . . . . . . . . . . . 63 13.2 Clock Doubling Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 14.0 ELECTRICAL SPECIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 14.1 DC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 14.2 AC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 15.0 PRODUCT ORDERING INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 15.1 Valid Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 16.0 PACKAGING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 LIST OF FIGURES FIGURE 1-1: Functional Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 FIGURE 2-1: Pin Assignments for 40-contact WQFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 FIGURE 2-2: Pin Assignments for 40-pin PDIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 FIGURE 2-3: Pin Assignments for 44-lead TQFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 FIGURE 2-4: Pin Assignments for 44-lead PLCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 FIGURE 3-1: Program Memory Organization for 16 KByte SST89x54RDx . . . . . . . . . . . . . . . . . . . . . . . . . 11 FIGURE 3-2: Program Memory Organization for 32 KByte SST89x58RDx . . . . . . . . . . . . . . . . . . . . . . . . . 12 FIGURE 3-3: Internal and External Data Memory Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 FIGURE 3-4: Dual Data Pointer Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 FIGURE 4-1: Chip-Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 FIGURE 4-2: Block-Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 FIGURE 4-3: Sector-Erase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 FIGURE 4-4: Byte-Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 ©2007 Silicon Storage Technology, Inc. S71255-08-000 3 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet FIGURE 4-5: Byte-Verify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 FIGURE 4-6: Prog-SB3, Prog-SB2, Prog-SB1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 FIGURE 4-7: Prog-SC0 and Prog-SC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 FIGURE 4-8: Enable-Clock-Double . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 FIGURE 6-1: Framing Error Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 FIGURE 6-2: UART Timings in Mode 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 FIGURE 6-3: UART Timings in Modes 2 and 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 FIGURE 6-4: SPI Master-slave Interconnection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 FIGURE 6-5: SPI Transfer Format with CPHA = 0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 FIGURE 6-6: SPI Transfer Format with CPHA = 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 FIGURE 7-1: Block Diagram of Programmable Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 FIGURE 8-1: PCA Timer/Counter and Compare/Capture Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 FIGURE 8-2: PCA Capture Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 FIGURE 8-3: PCA Compare Mode (Software Timer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 FIGURE 8-4: PCA High Speed Output Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 FIGURE 8-5: PCA Pulse Width Modulator Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 FIGURE 8-6: PCA Watchdog Timer (Module 4 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 FIGURE 9-1: Security Lock Levels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 FIGURE 10-1: Power-on Reset Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 FIGURE 11-1: Interrupt Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 FIGURE 13-1: Oscillator Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 FIGURE 14-1: IDD vs. Frequency for 3V SST89V5xRD2/RD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 FIGURE 14-2: IDD vs. Frequency for 5V SST89E5xRD2/RD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 FIGURE 14-3: External Program Memory Read Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 FIGURE 14-4: External Data Memory Read Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 FIGURE 14-5: External Data Memory Write Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 FIGURE 14-6: External Clock Drive Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 FIGURE 14-7: Shift Register Mode Timing Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 FIGURE 14-8: AC Testing Input/Output Test Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 FIGURE 14-9: Float Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 FIGURE 14-10: A Test Load Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 FIGURE 14-11: IDD Test Condition, Active Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 FIGURE 14-12: IDD Test Condition, Idle Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 FIGURE 14-13: IDD Test Condition, Power-down Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 FIGURE 16-1: 40-pin Plastic Dual In-line Pins (PDIP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 FIGURE 16-2: 44-lead Plastic Lead Chip Carrier (PLCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 FIGURE 16-3: 44-lead Thin Quad Flat Pack (TQFP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 FIGURE 16-4: 40-contact Very-very-thin Quad Flat No-lead (WQFN). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 ©2007 Silicon Storage Technology, Inc. S71255-08-000 4 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet LIST OF TABLES TABLE 2-1: Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 TABLE 3-1: SFCF Values for Program Memory Block Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 TABLE 3-2: SFCF Values Under Different Reset Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 TABLE 3-3: External Data Memory RD#, WR# with EXTRAM bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 TABLE 3-4: FlashFlex SFR Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 TABLE 3-5: CPU related SFRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TABLE 3-6: Flash Memory Programming SFRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TABLE 3-7: Watchdog Timer SFRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 TABLE 3-8: Timer/Counters SFRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 TABLE 3-9: Interface SFRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 TABLE 3-10: PCA SFRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 TABLE 4-1: Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 TABLE 4-2: IAP Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 TABLE 5-1: Timer/Counter 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 TABLE 5-2: Timer/Counter 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 TABLE 5-3: Timer/Counter 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 TABLE 8-1: PCA Timer/Counter Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 TABLE 8-2: PCA Timer/Counter Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 TABLE 8-3: CMOD Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 TABLE 8-4: PCA High and Low Register Compare/Capture Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 TABLE 8-5: PCA Module Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 TABLE 8-6: PCA Module Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 TABLE 8-7: Pulse Width Modulator Frequencies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 TABLE 9-1: Security Lock Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 TABLE 9-2: Security Lock Access Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 TABLE 11-1: Interrupt Polling Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 TABLE 12-1: Power Saving Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 TABLE 13-1: Recommended Values for C1 and C2 by Crystal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 TABLE 13-2: Clock Doubling Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 TABLE 14-1: Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 TABLE 14-2: Reliability Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 TABLE 14-3: AC Conditions of Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 TABLE 14-4: Recommended System Power-up Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 TABLE 14-5: Pin Impedance (VDD=3.3V, TA=25 °C, f=1 Mhz, other pins open) . . . . . . . . . . . . . . . . . . . 65 TABLE 14-6: DC Electrical Characteristics for SST89E5xRD2/RD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 TABLE 14-7: DC Electrical Characteristics for SST89V5xRD2/RD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 TABLE 14-8: AC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 TABLE 14-9: External Clock Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 TABLE 14-10: Serial Port Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 TABLE 14-11: Flash Memory Programming/Verification Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 TABLE 16-1: Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 ©2007 Silicon Storage Technology, Inc. S71255-08-000 5 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 1.0 FUNCTIONAL BLOCKS 8051 CPU Core ALU, ACC, B-Register, Instruction Register, Program Counter, Timing and Control Interrupt Control Oscillator Flash Control Unit Watchdog Timer SuperFlash EEPROM Primary Block 16K/32K x8 RAM 1K x8 8 I/O I/O Port 0 Secondary Block 8K x8 10 Interrupts 8 Security Lock I/O I/O Port 1 8 I/O I/O Port 2 8 Timer 0 (16-bit) I/O I/O Port 3 4 Timer 1 (16-bit) I/O I/O Port 4 Timer 2 (16-bit) SPI PCA Enhanced UART 1255 B1.2 FIGURE 1-1: Functional Block Diagram ©2007 Silicon Storage Technology, Inc. S71255-08-000 6 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet (CEX2 / MOSI) P1.5 1 P0.3 (AD3) P0.2 (AD2) P0.1 (AD1) P0.0 (AD0) VDD P1.0 (T2) P1.1 (T2 EX) P1.2 (ECI) 40 P0.4 (AD4) (CEX3 / MISO) P1.6 P0.5 (AD5) (CEX4 / SCK) P1.7 P0.6 (AD6) RST P0.7 (AD7) (RXD) P3.0 Top View (TXD) P3.1 (contacts facing down) EA# ALE/PROG# (A12) P2.4 (A11) P2.3 P2.5 (A13) (A10) P2.2 (T1) P3.5 (A9) P2.1 P2.6 (A14) (A8) P2.0 (T0) P3.4 VSS P2.7 (A15) XTAL1 (INT1#) P3.3 XTAL2 PSEN# (RD#) P3.7 (INT0#) P3.2 (WR#) P3.6 FIGURE P1.3 (CEX0) P1.4 (CEX1 / SS#) 2.0 PIN ASSIGNMENTS 1255 40-wqfn QI P1.0 2-1: Pin Assignments for 40-contact WQFN ©2007 Silicon Storage Technology, Inc. S71255-08-000 7 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD P0.2 (AD2) (CEX1 / SS#) P1.4 5 36 P0.3 (AD3) (CEX2 / MOSI) P1.5 6 35 P0.4 (AD4) (CEX3 / MISO) P1.6 7 34 P0.5 (AD5) (CEX4 / SCK) P1.7 8 44 43 42 41 40 39 38 37 36 35 34 (RXD) P3.0 40-pin PDIP Top View 33 32 9 31 10 (TXD) P3.1 11 30 ALE/PROG# (RXD) P3.0 5 (INT0#) P3.2 12 29 PSEN# INT2#/P4.3 6 (TXD) P3.1 7 RST P0.3 (AD3) 37 P0.2 (AD2) 4 P0.1 (AD1) P0.1 (AD1) (CEX0) P1.3 P0.0 (AD0) 38 VDD 3 P4.2/INT3# P0.0 (AD0) (ECI) P1.2 P1.0 (T2) VDD 39 P1.1 (T2 EX) 40 2 P1.2 (ECI) 1 P1.3 (CEX0) (T2) P1.0 (T2 EX) P1.1 P1.4 (SS# / CEX1) Data Sheet P0.6 (AD6) P0.7 (AD7) (CEX2 / MOSI) P1.5 1 33 P0.4 (AD4) (CEX3 / MISO) P1.6 2 32 P0.5 (AD5) (CEX4 / SCK) P1.7 3 31 P0.6 (AD6) RST 4 30 P0.7 (AD7) 29 EA# 28 P4.1 27 ALE/PROG# EA# 44-lead TQFP Top View P2.7 (A15) (T1) P3.5 15 26 P2.5 (A13) (T0) P3.4 10 24 P2.6 (A14) (WR#) P3.6 16 25 P2.4 (A12) (T1) P3.5 11 23 12 13 14 15 16 17 18 19 20 21 22 P2.5 (A13) (RD#) P3.7 17 24 P2.3 (A11) XTAL2 18 23 P2.2 (A10) XTAL1 19 22 P2.1 (A9) VSS 20 21 P2.0 (A8) (A12) P2.4 25 (A11) P2.3 9 (A10) P2.2 (INT1#) P3.3 (A9) P2.1 14 (A8) P2.0 PSEN# (T0) P3.4 P4.0 26 VSS 8 XTAL1 (INT0#) P3.2 P2.6 (A14) XTAL2 P2.7 (A15) 27 (RD#) P3.7 28 (WR#) P3.6 13 (INT1#) P3.3 1255 44-tqfp TQJ P2.0 1255 40-pdip PI P1.0 FIGURE FIGURE 2 1 44 43 42 41 40 VDD P0.3 (AD3) 3 P0.2 (AD2) P1.0 (T2) 4 P0.1 (AD1) P1.1 (T2 EX) 5 P0.0 (AD0) P1.2 (ECI) 6 P4.2/INT3# P1.3 (CEX0) 2-3: Pin Assignments for 44-lead TQFP P1.4 (SS# / CEX1) 2-2: Pin Assignments for 40-pin PDIP 7 39 P0.4 (AD4) (CEX3 / MISO) P1.6 8 38 P0.5 (AD5) (CEX4 / SCK) P1.7 9 37 P0.6 (AD6) RST 10 36 P0.7 (AD7) (RXD) P3.0 11 35 EA# INT2#/P4.3 12 34 P4.1 (TXD) P3.1 13 33 ALE/PROG# (INT0#) P3.2 14 32 PSEN# (INT1#) P3.3 15 31 P2.7 (A15) (T0) P3.4 16 30 P2.6 (A14) (T1) P3.5 17 29 18 19 20 21 22 23 24 25 26 27 28 P2.5 (A13) (A11) P2.3 (A10) P2.2 (A9) P2.1 (A8) P2.0 P4.0 VSS XTAL1 XTAL2 (RD#) P3.7 44-lead PLCC Top View (A12) P2.4 (CEX2 / MOSI) P1.5 (WR#) P3.6 FIGURE 1255 44-plcc NJ P3.0 2-4: Pin Assignments for 44-lead PLCC ©2007 Silicon Storage Technology, Inc. S71255-08-000 8 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 2.1 Pin Descriptions TABLE 2-1: Pin Descriptions (1 of 2) Symbol Type1 P0[7:0] I/O Port 0: Port 0 is an 8-bit open drain bi-directional I/O port. As an output port each pin can sink several LS TTL inputs. Port 0 pins float that have ‘1’s written to them, and in this state can be used as high-impedance inputs. In this application, it uses strong internal pull-ups when transitioning to VOH. Port 0 also receives the code bytes during the external host mode programming, and outputs the code bytes during the external host mode verification. External pull-ups are required during program verification. P1[7:0] I/O with internal pull-ups Port 1: Port 1 is an 8-bit bi-directional I/O port with internal pull-ups. The Port 1 output buffers can drive LS TTL inputs. Port 1 pins are pulled high by the internal pull-ups when “1”s are written to them and can be used as inputs in this state. As inputs, Port 1 pins that are externally pulled low will source current because of the internal pull-ups. P1[5, 6, 7] have high current drive of 16 mA. Port 1 also receives the low-order address bytes during the external host mode programming and verification. P1[0] I/O P1[1] I T2EX: Timer/Counter 2 capture/reload trigger and direction control P1[2] I ECI: PCA Timer/Counter External Input: This signal is the external clock input for the PCA timer/counter. P1[3] I/O CEX0: Compare/Capture Module External I/O Each compare/capture module connects to a Port 1 pin for external I/O. When not used by the PCA, this pin can handle standard I/O. P1[4] I/O SS#: Master Input or Slave Output for SPI. OR CEX1: Compare/Capture Module External I/O P1[5] I/O MOSI: Master Output line, Slave Input line for SPI OR CEX2: Compare/Capture Module External I/O P1[6] I/O MISO: Master Input line, Slave Output line for SPI OR CEX3: Compare/Capture Module External I/O P1[7] I/O SCK: Master clock output, slave clock input line for SPI OR CEX4: Compare/Capture Module External I/O P2[7:0] I/O with internal pull-up Port 2: Port 2 is an 8-bit bi-directional I/O port with internal pull-ups. Port 2 pins are pulled high by the internal pull-ups when “1”s are written to them and can be used as inputs in this state. As inputs, Port 2 pins that are externally pulled low will source current because of the internal pull-ups. Port 2 sends the high-order address byte during fetches from external Program memory and during accesses to external Data Memory that use 16-bit address (MOVX@DPTR). In this application, it uses strong internal pull-ups when transitioning to VOH. Port 2 also receives some control signals and high-order address bits during the external host mode programming and verification. P3[7:0] I/O with internal pull-up Port 3: Port 3 is an 8-bit bidirectional I/O port with internal pull-ups. The Port 3 output buffers can drive LS TTL inputs. Port 3 pins are pulled high by the internal pull-ups when “1”s are written to them and can be used as inputs in this state. As inputs, Port 3 pins that are externally pulled low will source current because of the internal pull-ups. Port 3 also receives some control signals and high-order address bits during the external host mode programming and verification. P3[0] I RXD: Universal Asynchronous Receiver/Transmitter (UART) - Receive input P3[1] O TXD: UART - Transmit output Name and Functions T2: External count input to Timer/Counter 2 or Clock-out from Timer/Counter 2 ©2007 Silicon Storage Technology, Inc. S71255-08-000 9 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 2-1: Pin Descriptions (Continued) (2 of 2) Symbol Type1 P3[2] I INT0#: External Interrupt 0 Input P3[3] I INT1#: External Interrupt 1 Input P3[4] I T0: External count input to Timer/Counter 0 P3[5] I T1: External count input to Timer/Counter 1 P3[6] O WR#: External Data Memory Write strobe P3[7] O RD#: External Data Memory Read strobe PSEN# I/O Program Store Enable: PSEN# is the Read strobe to External Program Store. When the device is executing from Internal Program Memory, PSEN# is inactive (VOH). When the device is executing code from External Program Memory, PSEN# is activated twice each machine cycle, except when access to External Data Memory while one PSEN# activation is skipped in each machine cycle. A forced high-to-low input transition on the PSEN# pin while the RST input is continually held high for more than 20 machine cycles will cause the device to enter External Host mode for programming. RST I Reset: While the oscillator is running, a high logic state on this pin for two machine cycles will reset the device. After a reset, if the PSEN# pin is driven by a high-to-low input transition while the RST input pin is held high, the device will enter the External Host mode, otherwise the device will enter the Normal operation mode. EA# I External Access Enable: EA# must be driven to VIL in order to enable the device to fetch code from the External Program Memory. EA# must be driven to VIH for internal program execution. However, Security lock level 4 will disable EA#, and program execution is only possible from internal program memory. The EA# pin can tolerate a high voltage2 of 12V. ALE/PROG# I/O Address Latch Enable: ALE is the output signal for latching the low byte of the address during an access to external memory. This pin is also the programming pulse input (PROG#) for flash programming. Normally the ALE3 is emitted at a constant rate of 1/6 the crystal frequency4 and can be used for external timing and clocking. One ALE pulse is skipped during each access to external data memory. However, if AO is set to 1, ALE is disabled. P4[3:0]5 I/O with internal pull-ups Port 4: Port 4 is an 4-bit bi-directional I/O port with internal pull-ups. The port 4 output buffers can drive LS TTL inputs. Port 4 pins are pulled high by the internal pull-ups when ‘1’s are written to them and can be used as inputs in this state. As inputs, port 4 pins that are externally pulled low will source current because of the internal pull-ups. P4[0] I/O Bit 0 of port 4 P4[1] I/O Bit 1 of port 4 P4[2] / INT3# I/O Bit 2 of port 4 / INT3# External interrupt 3 input P4[3] / INT2# I/O Bit 3 of port 4 / INT2# External interrupt 2 input XTAL1 I Crystal 1: Input to the inverting oscillator amplifier and input to the internal clock generator circuits. XTAL2 O Crystal 2: Output from the inverting oscillator amplifier VDD I Power Supply VSS I Ground Name and Functions T2-1.0 1255 1. I = Input; O = Output 2. It is not necessary to receive a 12V programming supply voltage during flash programming. 3.ALE loading issue: When ALE pin experiences higher loading (>30pf) during the reset, the MCU may accidentally enter into modes other than normal working mode. The solution is to add a pull-up resistor of 3-50 KΩ to VDD, e.g. for ALE pin. 4. For 6 clock mode, ALE is emitted at 1/3 of crystal frequency. 5. Port 4 is not present on the PDIP package. ©2007 Silicon Storage Technology, Inc. S71255-08-000 10 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 3.0 MEMORY ORGANIZATION The device has separate address spaces for program and data memory. bank selection. Please refer to Figures 3-1 and 3-2 for the program memory configuration. Program bank selection is described in the next section. 3.1 Program Flash Memory The 16K/32K x8 primary SuperFlash block is organized as 128/256 sectors, each sector consists of 128 Bytes. There are two internal flash memory blocks in the device. The primary flash memory block (Block 0) has 16/32 KByte. The secondary flash memory block (Block 1) has 8 KByte. Since the total program address space is limited to 64 KByte, the SFCF[1:0] bit are used to control program For both blocks, the 7 least significant program address bits select the byte within the sector. The remainder of the program address bits select the sector within the block. EA# = 1 SFCF[1:0] = 00 EA# = 0 FFFFH The 8K x8 secondary SuperFlash block is organized as 64 sectors, each sector consists also of 128 Bytes. FFFFH E000H DFFFH 8 KByte Block 1 EA# = 1 SFCF[1:0] = 01 FFFFH E000H DFFFH Not Accessible 8 KByte Block 1 EA# = 1 SFCF[1:0] = 10, 11 FFFFH Not Accessible Not Accessible External 64 KByte 4000H 3FFFH 2000H 1FFFH 0000H 0000H 8 KByte Block 0 4000H 3FFFH 4000H 3FFFH 16 KByte Block 0 8 KByte Block 1 0000H 16 KByte Block 0 0000H 1255 F02.1 FIGURE 3-1: Program Memory Organization for 16 KByte SST89x54RDx ©2007 Silicon Storage Technology, Inc. S71255-08-000 11 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet EA# = 1 SFCF[1:0] = 00 EA# = 0 FFFFH FFFFH 8 KByte Block 1 E000H DFFFH EA# = 1 SFCF[1:0] = 01 FFFFH 8 KByte Block 1 EA# = 1 SFCF[1:0] = 10, 11 FFFFH E000H DFFFH External 32 KByte External 24 KByte External 64 KByte 8000H 7FFFH External 24 KByte 8000H 7FFFH 8000H 7FFFH 24 KByte Block 0 32 KByte Block 0 2000H 1FFFH 0000H 32 KByte Block 0 8 KByte Block 1 0000H 0000H 0000H 1255 F03.0 FIGURE 3-2: Program Memory Organization for 32 KByte SST89x58RDx 3.2 Program Memory Block Switching The program memory block switching feature of the device allows either Block 1 or the lowest 8 KByte of Block 0 to be used for the lowest 8 KByte of the program address space. SFCF[1:0] controls program memory block switching. TABLE 3-1: SFCF Values for Program Memory Block Switching SFCF[1:0] 10, 11 Program Memory Block Switching Block 1 is not visible to the PC; Block 1 is reachable only via in-application programming from E000H - FFFFH. 01 Both Block 0 and Block 1 are visible to the PC. Block 0 is occupied from 0000H - 7FFFH. Block 1 is occupied from E000H - FFFFH. 00 Block 1 is overlaid onto the low 8K of the program address space; occupying address locations 0000H 1FFFH. When the PC falls within 0000H - 1FFFH, the instruction will be fetched from Block 1 instead of Block 0. Outside of 0000H - 1FFFH, Block 0 is used. Locations 0000H - 1FFFH of Block 0 are reachable through in-application programming. T3-1.0 1255 Once out of reset, the SFCF[0] bit can be changed dynamically by the program for desired effects. Changing SFCF[0] will not change the SC0 bit. 3.2.1 Reset Configuration of Program Memory Block Switching Program memory block switching is initialized after reset according to the state of the Start-up Configuration bit SC0 and/or SC1. The SC0 and SC1 bits are programmed via an external host mode command or an IAP Mode command. See Table 4-2. ©2007 Silicon Storage Technology, Inc. S71255-08-000 12 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet When instructions access addresses in the upper 128 bytes (above 7FH), the MCU determines whether to access the SFRs or RAM by the type of instruction given. If it is indirect, then RAM is accessed. If it is direct, then an SFR is accessed. See the examples below. Caution must be taken when dynamically changing the SFCF[0] bit. Since this will cause different physical memory to be mapped to the logical program address space. The user must avoid executing block switching instructions within the address range 0000H to 1FFFH. TABLE Indirect Access: 3-2: SFCF Values Under Different Reset Conditions MOV@R0, #data; R0 contains 90H State of SFCF[1:0] after: Register R0 points to 90H which is located in the upper address range. Data in “#data” is written to RAM location 90H rather than port 1. Power-on or External Reset WDT Reset or Brown-out Reset Software Reset SC11 SC01 U (1) U (1) 00 (default) x0 10 U (1) P (0) 01 x1 11 P (0) U (1) 10 10 10 P (0) P (0) 11 11 11 Direct Access: MOV90H, #data; write data to P1 Data in “#data” is written to port 1. Instructions that write directly to the address write to the SFRs. To access the expanded RAM, the EXTRAM bit must be cleared and MOVX instructions must be used. The extra 768 bytes of memory is physically located on the chip and logically occupies the first 768 bytes of external memory (addresses 000H to 2FFH). T3-2.0 1255 1. P = Programmed (Bit logic state = 0), U = Unprogrammed (Bit logic state = 1) 3.3 Data RAM Memory When EXTRAM = 0, the expanded RAM is indirectly addressed using the MOVX instruction in combination with any of the registers R0, R1 of the selected bank or DPTR. Accessing the expanded RAM does not affect ports P0, P3.6 (WR#), P3.7 (RD#), or P2. With EXTRAM = 0, the expanded RAM can be accessed as in the following example. The data RAM has 1024 bytes of internal memory. The RAM can be addressed up to 64KB for external data memory. 3.4 Expanded Data RAM Addressing The SST89E/V5xRDx both have the capability of 1K of RAM. See Figure 3-3. Expanded RAM Access (Indirect Addressing only): The device has four sections of internal data memory: MOVX@DPTR, A; DPTR contains 0A0H 1. The lower 128 Bytes of RAM (00H to 7FH) are directly and indirectly addressable. DPTR points to 0A0H and data in “A” is written to address 0A0H of the expanded RAM rather than external memory. Access to external memory higher than 2FFH using the MOVX instruction will access external memory (0300H to FFFFH) and will perform in the same way as the standard 8051, with P0 and P2 as data/address bus, and P3.6 and P3.7 as write and read timing signals. 2. The higher 128 Bytes of RAM (80H to FFH) are indirectly addressable. 3. The special function registers (80H to FFH) are directly addressable only. 4. The expanded RAM of 768 Bytes (00H to 2FFH) is indirectly addressable by the move external instruction (MOVX) and clearing the EXTRAM bit. (See “Auxiliary Register (AUXR)” in Section 3.6, “Special Function Registers”) When EXTRAM = 1, MOVX @Ri and MOVX @DPTR will be similar to the standard 8051. Using MOVX @Ri provides an 8-bit address with multiplexed data on Port 0. Other output port pins can be used to output higher order address bits. This provides external paging capabilities. Using MOVX @DPTR generates a 16-bit address. This allows external addressing up the 64K. Port 2 provides the high-order eight address bits (DPH), and Port 0 multiplexes the low order eight address bits (DPL) with data. Both MOVX @Ri and MOVX @DPTR generates the necessary Since the upper 128 bytes occupy the same addresses as the SFRs, the RAM must be accessed indirectly. The RAM and SFRs space are physically separate even though they have the same addresses. ©2007 Silicon Storage Technology, Inc. S71255-08-000 13 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet read and write signals (P3.6 - WR# and P3.7 - RD#) for external memory use. Table 3-3 shows external data memory RD#, WR# operation with EXTRAM bit. TABLE The stack pointer (SP) can be located anywhere within the 256 bytes of internal RAM (lower 128 bytes and upper 128 bytes). The stack pointer may not be located in any part of the expanded RAM. 3-3: External Data Memory RD#, WR# with EXTRAM bit MOVX @DPTR, A or MOVX A, @DPTR MOVX @Ri, A or MOVX A, @Ri AUXR ADDR < 0300H ADDR >= 0300H ADDR = Any EXTRAM = 0 RD# / WR# not asserted RD# / WR# asserted RD# / WR# not asserted1 EXTRAM = 1 RD# / WR# asserted RD# / WR# asserted RD# / WR# asserted T3-3.0 1255 1. Access limited to ERAM address within 0 to 0FFH; cannot access 100H to 02FFH. ©2007 Silicon Storage Technology, Inc. S71255-08-000 14 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 2FFH Expanded RAM 768 Bytes FFH 80H 7FH (Indirect Addressing) 000H 00H FFFFH (Indirect Addressing) Upper 128 Bytes Internal RAM FFH (Direct Addressing) Special Function Registers (SFRs) 80H Lower 128 Bytes Internal RAM (Indirect & Direct Addressing) (Indirect Addressing) FFFFH (Indirect Addressing) External Data Memory External Data Memory 0300H 2FFH Expanded RAM 000H 0000H EXTRAM = 0 EXTRAM = 1 1255 F05.0 FIGURE 3-3: Internal and External Data Memory Structure ©2007 Silicon Storage Technology, Inc. S71255-08-000 15 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 3.5 Dual Data Pointers The device has two 16-bit data pointers. The DPTR Select (DPS) bit in AUXR1 determines which of the two data pointers is accessed. When DPS=0, DPTR0 is selected; when DPS=1, DPTR1 is selected. Quickly switching between the two data pointers can be accomplished by a single INC instruction on AUXR1. (See Figure 3-4) AUXR1 / bit0 DPS DPTR1 DPTR0 DPS = 0 → DPTR0 DPS = 1 → DPTR1 DPL 82H DPH 83H External Data Memory 1255 F06.0 FIGURE 3-4: Dual Data Pointer Organization 3.6 Special Function Registers Most of the unique features of the FlashFlex microcontroller family are controlled by bits in special function registers (SFRs) located in the SFR memory map shown in Table 3-4. Individual descriptions of each SFR are provided and reset values indicated in Tables 3-5 to 3-9. TABLE 3-4: FlashFlex SFR Memory Map 8 BYTES F8H IP11 F0H B1 E8H IEA1 E0H ACC1 D8H CCON1 D0H PSW1 C8H T2CON1 C0H WDTC1 B8H IP1 SADEN B0H P31 SFCF A8H IE1 SADDR A0H P21 CH CCAP0H CCAP1H CCAP2H CCAP3H CCAP4H FFH IP1H CL CCAP0L CCAP1L CCAP2L CCAP3L F7H CCAP4L EFH E7H CMOD T2MOD CCAPM0 RCAP2L CCAPM1 CCAPM2 RCAP2H TL2 CCAPM3 CCAPM4 DFH SPCR D7H TH2 CFH C7H BFH SFCM SFAL SFAH SFDT SPSR SFST IPH B7H XICON AUXR1 AFH P4 98H SCON1 90H P11 88H TCON1 TMOD TL0 TL1 80H P01 SP DPL DPH A7H SBUF 9FH 97H TH0 TH1 AUXR WDTD SPDR 8FH PCON 87H T3-4.0 1255 1. Bit addressable SFRs ©2007 Silicon Storage Technology, Inc. S71255-08-000 16 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 3-5: CPU related SFRs Symbol Description Direct Address Bit Address, Symbol, or Alternative Port Function MSB LSB Reset Value ACC1 Accumulator E0H ACC[7:0] 00H B1 B Register F0H B[7:0] 00H PSW1 Program Status Word D0H SP Stack Pointer 81H SP[7:0] 07H DPL Data Pointer Low 82H DPL[7:0] 00H DPH Data Pointer High 83H DPH[7:0] 00H IE1 Interrupt Enable A8H EA EC ET2 ES ET1 EX1 ET0 EX0 00H IEA1 Interrupt Enable A E8H - - - - EBO - - - xxxx0xxxb IP1 Interrupt Priority Reg B8H - PPC PT2 PS PT1 PX1 PT0 PX0 x0000000b IPH Interrupt Priority Reg High B7H - PPCH PT2H PSH PT1H PX1H PT0H PX0H x0000000b IP11 Interrupt Priority Reg A F8H - - - - PBO PX3 PX2 - xxxx0xxxb IP1H Interrupt Priority Reg A High F7H - - - - PBOH PX3H PX3 - xxxx0xxxb PCON Power Control 87H SMOD1 SMOD0 BOF POF GF1 GF0 PD IDL 00010000b AUXR Auxiliary Reg 8EH - - - - - - EXTRAM AO xxxxxxx00b AUXR1 Auxiliary Reg 1 A2H - - - - GF2 0 - DPS xxxx00x0b AEH X EX3 IE3 IT3 0 EX2 IE2 IT2 00H XICON2 External Interrupt Control CY AC F0 RS1 RS0 OV F1 P 00H T3-5.0 1255 1. Bit Addressable SFRs 2. X = Don’t care TABLE 3-6: Flash Memory Programming SFRs Symbol Description Bit Address, Symbol, or Alternative Port Function Direct Address MSB LSB IAPEN - - - - SWR BSEL Reset Value SFCF SuperFlash Configuration B1H - SFCM SuperFlash Command B2H FIE SFAL SuperFlash Address Low B3H SuperFlash Low Order Byte Address Register - A7 to A0 (SFAL) 00H SFAH SuperFlash Address High B4H SuperFlash High Order Byte Address Register - A15 to A8 (SFAH) 00H SFDT SuperFlash Data B5H SuperFlash Data Register 00H FCM[6:0] ©2007 Silicon Storage Technology, Inc. x0xxxx00b 00H S71255-08-000 17 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 3-6: Flash Memory Programming SFRs Symbol Description SFST SuperFlash Status Bit Address, Symbol, or Alternative Port Function Direct Address MSB B6H SB1_i SB2_i SB3_i - EDC_i FLASH_BUSY - LSB Reset Value - 000x00xxb T3-6.0 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 18 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 3-7: Watchdog Timer SFRs Direct Address Symbol Description WDTC1 Watchdog Timer Control C0H WDTD Watchdog Timer Data/Reload 85H Bit Address, Symbol, or Alternative Port Function MSB - - - WDOUT WDRE WDTS WDT LSB Reset Value SWDT xxx00x00b Watchdog Timer Data/Reload 00H T3-7.0 1255 1. Bit Addressable SFRs TABLE 3-8: Timer/Counters SFRs Direct Address Bit Address, Symbol, or Alternative Port Function MSB LSB Reset Value Symbol Description TMOD Timer/Counter Mode Control 89H TCON1 Timer/Counter Control 88H TH0 Timer 0 MSB 8CH TH0[7:0] 00H TL0 Timer 0 LSB 8AH TL0[7:0] 00H TH1 Timer 1 MSB 8DH TH1[7:0] 00H TL1 Timer 1 LSB 8BH TL1[7:0] 00H Timer 1 Timer 0 00H GATE C/T# M1 M0 GATE C/T# M1 M0 TF1 TR1 TF0 TR0 IE1 IT1 IE0 IT0 00H T2CON1 Timer / Counter 2 Control C8H TF2 EXF2 RCLK TCLK EXEN2 TR2 C/T2# CP/RL2# 00H T2MOD2 Timer2 Mode Control C9H X - - - - - T2OE DCEN xxxxxx00b TH2 Timer 2 MSB CDH TH2[7:0] 00H TL2 Timer 2 LSB CCH TL2[7:0] 00H RCAP2H Timer 2 Capture MSB CBH RCAP2H[7:0] 00H RCAP2L Timer 2 Capture LSB CAH RCAP2L[7:0] 00H T3-8.0 1255 1. Bit Addressable SFRs 2. X = Don’t care ©2007 Silicon Storage Technology, Inc. S71255-08-000 19 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 3-9: Interface SFRs Symbol Description Direct Address SBUF Serial Data Buffer 99H SCON1 Serial Port Control 98H Bit Address, Symbol, or Alternative Port Function MSB LSB SBUF[7:0] SM0/FE SM1 SM2 REN RESET Value Indeterminate TB8 RB8 TI RI 00H SADDR Slave Address A9H SADDR[7:0] 00H SADEN Slave Address Mask B9H SADEN[7:0] 00H SPCR SPI Control Register D5H SPIE SPE SPSR SPI Status Register AAH SPIF WCOL SPDR SPI Data Register 86H SPDR[7:0] 00H P01 Port 0 80H P0[7:0] FFH P11 Port 1 90H P21 Port 2 A0H P31 Port 3 B0H RD# WR# T1 T0 P42 Port 4 A5H 1 1 1 1 - - DORD MSTR CPOL CPHA SPR1 SPR0 04H 00H - - - - T2EX T2 P2[7:0] FFH FFH INT1# INT0# P4.3 P4.2 TXD RXD FFH P4.1 P4.0 FFH T3-9.0 1255 1. Bit Addressable SFRs 2. P4 is similar to P1 and P3 ports ©2007 Silicon Storage Technology, Inc. S71255-08-000 20 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 3-10: PCA SFRs Direct Address MSB Bit Address, Symbol, or Alternative Port Function LSB RESET Value Symbol Description CH CL PCA Timer/Counter F9H E9H CCON1 PCA Timer/Counter Control Register D8H CF CR - CCF4 CCF3 CCF2 CCF1 CCF0 00x00000b CMOD PCA Timer/Counter Mode Register D9H CIDL WDTE - - - CPS1 CPS0 ECF 00xxx000b CCAP0H PCA Module 0 Compare/Capture CCAP0L Registers FAH CCAP0H[7:0] 00H EAH CCAP0L[7:0] 00H FBH CCAP1H[7:0] 00H EBH CCAP1L[7:0] 00H FCH CCAP2H[7:0] 00H ECH CCAP2L[7:0] 00H FDH CCAP3H[7:0] 00H EDH CCAP3L[7:0] 00H FEH CCAP4H[7:0] 00H EEH CCAP4L[7:0] 00H CCAP1H PCA Module 1 Compare/Capture CCAP1L Registers CCAP2H PCA Module 2 Compare/Capture CCAP2L Registers CCAP3H PCA Module 3 Compare/Capture CCAP3L Registers CCAP4H PCA Module 4 Compare/Capture CCAP4L Registers CH[7:0] CL[7:0] 00H 00H DAH - ECOM0 CAPP0 CAPN0 MAT0 TOG0 PWM0 ECCF0 x0000000b DBH - ECOM1 CAPP1 CAPN1 MAT1 TOG1 PWM1 ECCF1 x0000000b DCH - ECOM2 CAPP2 CAPN2 MAT2 TOG2 PWM2 ECCF2 x0000000b CCAPM3 DDH - ECOM3 CAPP3 CAPN3 MAT3 TOG3 PWM3 ECCF3 x0000000b CCAPM4 DEH - ECOM4 CAPP4 CAPN4 MAT4 TOG4 PWM4 ECCF4 x0000000b CCAPM0 PCA Compare/Capture CCAPM1 Module Mode CCAPM2 Registers T3-10.0 1255 1. Bit Addressable SFRs ©2007 Silicon Storage Technology, Inc. S71255-08-000 21 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet SuperFlash Configuration Register (SFCF) Location 7 6 5 4 3 2 1 0 Reset Value B1H - IAPEN - - - - SWR BSEL x0xxxx00b Symbol Function IAPEN Enable IAP operation 0: IAP commands are disabled 1: IAP commands are enabled SWR Software Reset See Section 10.2, “Software Reset” BSEL Program memory block switching bit See Figures 3-1 and 3-2 and Table 3-2 SuperFlash Command Register (SFCM) Location 7 6 5 4 3 2 1 0 Reset Value B2H FIE FCM6 FCM5 FCM4 FCM3 FCM2 FCM1 FCM0 00H Symbol Function FIE Flash Interrupt Enable. 0: INT1# is not reassigned. 1: INT1# is re-assigned to signal IAP operation completion. External INT1# interrupts are ignored. FCM[6:0] Flash operation command 000_0001b Chip-Erase 000_1011b Sector-Erase 000_1101b Block-Erase 000_1100b Byte-Verify1 000_1110b Byte-Program 000_1111b Prog-SB1 000_0011b Prog-SB2 000_0101b Prog-SB3 000_1001b Prog-SC0 000_1001b Prog-SC1 000_1000bEnable-Clock-Double All other combinations are not implemented, and reserved for future use. 1. Byte-Verify has a single machine cycle latency and will not generate any INT1# interrupt regardless of FIE. SuperFlash Address Registers (SFAL) Location 7 6 B3H 5 4 3 2 1 0 SuperFlash Low Order Byte Address Register Reset Value 00H Symbol Function SFAL Mailbox register for interfacing with flash memory block. (Low order address register). SuperFlash Address Registers (SFAH) Location 7 B4H 6 5 4 3 2 SuperFlash High Order Byte Address Register 1 0 Reset Value 00H Symbol Function SFAH Mailbox register for interfacing with flash memory block. (High order address register). ©2007 Silicon Storage Technology, Inc. S71255-08-000 22 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet SuperFlash Data Register (SFDT) Location 7 6 5 B5H 4 3 2 1 0 Reset Value SuperFlash Data Register 00H Symbol Function SFDT Mailbox register for interfacing with flash memory block. (Data register). SuperFlash Status Register (SFST) (Read Only Register) Location 7 6 5 4 3 2 1 0 Reset Value B6H SB1_i SB2_i SB3_i - EDC_i FLASH_BUSY - - xxxxx0xxb Symbol Function SB1_i Security Bit 1 status (inverse of SB1 bit) SB2_i Security Bit 2 status (inverse of SB2 bit) SB3_i Security Bit 3 status (inverse of SB3 bit) Please refer to Table 9-1 for security lock options. EDC_i Double Clock Status 0: 12 clocks per machine cycle 1: 6 clocks per machine cycle FLASH_BUSY Flash operation completion polling bit. 0: Device has fully completed the last IAP command. 1: Device is busy with flash operation. ©2007 Silicon Storage Technology, Inc. S71255-08-000 23 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet Interrupt Enable (IE) Location 7 6 5 4 3 2 1 0 Reset Value A8H EA EC ET2 ES ET1 EX1 ET0 EX0 00H Symbol Function EA Global Interrupt Enable. 0 = Disable 1 = Enable EC PCA Interrupt Enable. ET2 Timer 2 Interrupt Enable. ES Serial Interrupt Enable. ET1 Timer 1 Interrupt Enable. EX1 External 1 Interrupt Enable. ET0 Timer 0 Interrupt Enable. EX0 External 0 Interrupt Enable. Interrupt Enable A (IEA) Location 7 6 5 4 3 2 1 0 Reset Value E8H - - - - EBO - - - xxxx0xxxb Symbol Function EBO Brown-out Interrupt Enable. 1 = Enable the interrupt 0 = Disable the interrupt ©2007 Silicon Storage Technology, Inc. S71255-08-000 24 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet Interrupt Priority (IP) Location 7 6 5 4 3 2 1 0 Reset Value B8H - PPC PT2 PS PT1 PX1 PT0 PX0 x0000000b Symbol Function PPC PCA interrupt priority bit PT2 Timer 2 interrupt priority bit PS Serial Port interrupt priority bit PT1 Timer 1 interrupt priority bit PX1 External interrupt 1 priority bit PT0 Timer 0 interrupt priority bit PX0 External interrupt 0 priority bit Interrupt Priority High (IPH) Location 7 6 5 4 3 2 1 0 Reset Value B7H - PPCH PT2H PSH PT1H PX1H PT0H PX0H x0000000b Symbol Function PPCH PCA interrupt priority bit high PT2H Timer 2 interrupt priority bit high PSH Serial Port interrupt priority bit high PT1H Timer 1 interrupt priority bit high PX1H External interrupt 1 priority bit high PT0H Timer 0 interrupt priority bit high PX0H External interrupt 0 priority bit high Interrupt Priority 1 (IP1) Location 7 6 5 4 3 2 1 0 Reset Value F8H 1 - - 1 PBO PX3 PX2 1 1xx10001b Symbol Function PBO Brown-out interrupt priority bit PX2 External Interrupt 2 priority bit PX3 External Interrupt 3 priority bit Interrupt Priority 1 High (IP1H) Location 7 6 5 4 3 2 1 0 Reset Value F7H 1 - - 1 PBOH PX3H PX2H 1 1xx10001b Symbol Function PBOH Brown-out Interrupt priority bit high PX2H External Interrupt 2 priority bit high PX3H External Interrupt 3 priority bit high ©2007 Silicon Storage Technology, Inc. S71255-08-000 25 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet Auxiliary Register (AUXR) Location 7 6 5 4 3 2 1 0 Reset Value 8EH - - - - - - EXTRAM AO xxxxxx00b Symbol Function EXTRAM Internal/External RAM access 0: Internal Expanded RAM access within range of 00H to 2FFH using MOVX @Ri / @DPTR. Beyond 300H, the MCU always accesses external data memory. For details, refer to Section 3.4, “Expanded Data RAM Addressing” . 1: External data memory access. AO Disable/Enable ALE 0: ALE is emitted at a constant rate of 1/3 the oscillator frequency in 6 clock mode, 1/6 fOSC in 12 clock mode. 1: ALE is active only during a MOVX or MOVC instruction. Auxiliary Register 1 (AUXR1) Location 7 6 5 4 3 2 1 0 Reset Value A2H - - - - GF2 0 - DPS xxxx00x0b Symbol Function GF2 General purpose user-defined flag. DPS DPTR registers select bit. 0: DPTR0 is selected. 1: DPTR1 is selected. Watchdog Timer Control Register (WDTC) Location 7 6 5 4 3 2 1 0 Reset Value C0H - - - WDOUT WDRE WDTS WDT SWDT xxx00000b Symbol Function WDOUT Watchdog output enable. 0: Watchdog reset will not be exported on Reset pin. 1: Watchdog reset if enabled by WDRE, will assert Reset pin for 32 clocks. WDRE Watchdog timer reset enable. 0: Disable watchdog timer reset. 1: Enable watchdog timer reset. WDTS Watchdog timer reset flag. 0: External hardware reset or power-on reset clears the flag. Flag can also be cleared by writing a 1. Flag survives if chip reset happened because of watchdog timer overflow. 1: Hardware sets the flag on watchdog overflow. WDT Watchdog timer refresh. 0: Hardware resets the bit when refresh is done. 1: Software sets the bit to force a watchdog timer refresh. SWDT Start watchdog timer. 0: Stop WDT. 1: Start WDT. ©2007 Silicon Storage Technology, Inc. S71255-08-000 26 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet Watchdog Timer Data/Reload Register (WDTD) Location 7 6 5 85H 4 3 2 1 0 Reset Value Watchdog Timer Data/Reload 00H Symbol Function WDTD Initial/Reload value in Watchdog Timer. New value won’t be effective until WDT is set. PCA Timer/Counter Control Register1 (CCON) Location 7 6 5 4 3 2 1 0 Reset Value D8H CF CR - CCF4 CCF3 CCF2 CCF1 CCF0 00x00000b 1. Bit addressable Symbol Function CF PCA Counter Overflow Flag Set by hardware when the counter rolls over. CF flags an interrupt if bit ECF in CMOD is set. CF may be set by either hardware or software, but can only cleared by software. CR PCA Counter Run control bit Set by software to turn the PCA counter on. Must be cleared by software to turn the PCA counter off. - Not implemented, reserved for future use. Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate. CCF4 PCA Module 4 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF3 PCA Module 3 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF2 PCA Module 2 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF1 PCA Module 1 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF0 PCA Module 0 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. ©2007 Silicon Storage Technology, Inc. S71255-08-000 27 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet PCA Timer/Counter Mode Register1 (CMOD) Location D9H 7 6 5 4 3 2 1 0 Reset Value CIDL WDTE - - - CPS1 CPS0 ECF 00xxx000b 1. Not bit addressable Symbol Function CIDL Counter Idle Control: 0: Programs the PCA Counter to continue functioning during idle mode 1: Programs the PCA Counter to be gated off during idle WDTE Watchdog Timer Enable: 0: Disables Watchdog Timer function on PCA module 4 1: Enables Watchdog Timer function on PCA module 4 - Not implemented, reserved for future use. Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate. CPS1 PCA Count Pulse Select bit 1 CPS0 PCA Count Pulse Select bit 2 CPS1 CPS0 Selected PCA Input1 0 0 0 Internal clock, fOSC/6 in 6 clock mode (fOSC/12 in 12 clock mode) 0 1 1 Internal clock, fOSC/2 in 6 clock mode (fOSC/4 in 12 clock mode) 1 0 2 Timer 0 overflow 1 1 3 External clock at ECI/P1.2 pin (max. rate = fOSC/4 in 6 clock mode, fOSC/8 in 12 clock mode) 1. fOSC = oscillator frequency ECF PCA Enable Counter Overflow interrupt: 0: Disables the CF bit in CCON 1: Enables CF bit in CCON to generate an interrupt ©2007 Silicon Storage Technology, Inc. S71255-08-000 28 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet PCA Compare/Capture Module Mode Register1 (CCAPMn) Location 7 6 5 4 3 2 1 0 Reset Value DAH - ECOM0 CAPP0 CAPN0 MAT0 TOG0 PWM0 ECCF0 00xxx000b DBH - ECOM1 CAPP1 CAPN1 MAT1 TOG1 PWM1 ECCF1 00xxx000b DCH - ECOM2 CAPP2 CAPN2 MAT2 TOG2 PWM2 ECCF2 00xxx000b DDH - ECOM3 CAPP3 CAPN3 MAT3 TOG3 PWM3 ECCF3 00xxx000b - ECOM4 CAPP4 CAPN4 MAT4 TOG4 PWM4 ECCF4 00xxx000b DEH 1. Not bit addressable Symbol Function - Not implemented, reserved for future use. Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate. ECOMn Enable Comparator 0: Disables the comparator function 1: Enables the comparator function CAPPn Capture Positive 0: Disables positive edge capture on CEX[4:0] 1: Enables positive edge capture on CEX[4:0] CAPNn Capture Negative 0: Disables negative edge capture on CEX[4:0] 1: Enables negative edge capture on CEX[4:0] MATn Match: Set ECOM[4:0] and MAT[4:0] to implement the software timer mode 0: Disables software timer mode 1: A match of the PCA counter with this module’s compare/capture register causes the CCFn bit in CCON to be set, flagging an interrupt. TOGn Toggle 0: Disables toggle function 1: A match of the PCA counter with this module’s compare/capture register causes the the CEXn pin to toggle. PWMn Pulse Width Modulation mode 0: Disables PWM mode 1: Enables CEXn pin to be used as a pulse width modulated output ECCFn Enable CCF Interrupt 0: Disables compare/capture flag CCF[4:0] in the CCON register to generate an interrupt request. 1: Enables compare/capture flag CCF[4:0] in the CCON register to generate an interrupt request. ©2007 Silicon Storage Technology, Inc. S71255-08-000 29 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet SPI Control Register (SPCR) Location 7 6 5 4 3 2 1 0 Reset Value D5H SPIE SPE DORD MSTR CPOL CPHA SPR1 SPR0 00H Symbol Function SPIE If both SPIE and ES are set to one, SPI interrupts are enabled. SPE SPI enable bit. 0: Disables SPI. 1: Enables SPI and connects SS#, MOSI, MISO, and SCK to pins P1.4, P1.5, P1.6, P1.7. DORD Data Transmission Order. 0: MSB first in data transmission. 1: LSB first in data transmission. MSTR Master/Slave select. 0: Selects Slave mode. 1: Selects Master mode. CPOL Clock Polarity 0: SCK is low when idle (Active High). 1: SCK is high when idle (Active Low). CPHA Clock Phase control bit. The CPHA bit with the CPOL bit control the clock and data relationship between master and slave. See Figures 6-5 and 6-6. 0: Shift triggered on the leading edge of the clock. 1: Shift triggered on the trailing edge of the clock. SPR1, SPR0 SPI Clock Rate Select bits. These two bits control the SCK rate of the device configured as master. SPR1 and SPR0 have no effect on the slave. The relationship between SCK and the oscillator frequency, fOSC, is as follows: SPR1 SPR0 SCK = fOSC divided by 0 0 1 1 0 1 0 1 4 16 64 128 SPI Status Register (SPSR) Location 7 6 5 4 3 2 1 0 Reset Value AAH SPIF WCOL - - - - - - 00xxxxxxb Symbol Function SPIF SPI Interrupt Flag. Upon completion of data transfer, this bit is set to 1. If SPIE =1 and ES =1, an interrupt is then generated. This bit is cleared by software. WCOL Write Collision Flag. Set if the SPI data register is written to during data transfer. This bit is cleared by software. ©2007 Silicon Storage Technology, Inc. S71255-08-000 30 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet SPI Data Register (SPDR) Location 7 6 5 4 86H 3 2 1 0 Reset Value SPDR[7:0] 00H Power Control Register (PCON) Location 7 6 5 4 3 2 1 0 Reset Value 87H SMOD1 SMOD0 BOF POF GF1 GF0 PD IDL 00010000b Symbol Function SMOD1 Double Baud rate bit. If SMOD1 = 1, Timer 1 is used to generate the baud rate, and the serial port is used in modes 1, 2, and 3. SMOD0 FE/SM0 Selection bit. 0: SCON[7] = SM0 1: SCON[7] = FE, BOF Brown-out detection status bit, this bit will not be affected by any other reset. BOF should be cleared by software. Power-on reset will also clear the BOF bit. 0: No brown-out. 1: Brown-out occurred POF Power-on reset status bit, this bit will not be affected by any other reset. POF should be cleared by software. 0: No Power-on reset. 1: Power-on reset occurred GF1 General-purpose flag bit. GF0 General-purpose flag bit. PD Power-down bit, this bit is cleared by hardware after exiting from power-down mode. 0: Power-down mode is not activated. 1: Activates Power-down mode. IDL Idle mode bit, this bit is cleared by hardware after exiting from idle mode. 0: Idle mode is not activated. 1: Activates idle mode. ©2007 Silicon Storage Technology, Inc. S71255-08-000 31 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet Serial Port Control Register (SCON) Location 7 6 5 4 3 2 1 0 Reset Value 98H SM0/FE SM1 SM2 REN TB8 RB8 TI RI 00000000b Symbol Function FE Set SMOD0 = 1 to access FE bit. 0: No framing error 1: Framing Error. Set by receiver when an invalid stop bit is detected. This bit needs to be cleared by software. SM0 SMOD0 = 0 to access SM0 bit. Serial Port Mode Bit 0 SM1 Serial Port Mode Bit 1 Description Baud Rate1 Shift Register fOSC/6 (6 clock mode) or fOSC/12 (12 clock mode) 1 8-bit UART Variable 0 2 9-bit UART fOSC/32 or fOSC/16 (6 clock mode) or fOSC/64 or fOSC/32 (12 clock mode) 1 3 9-bit UART Variable SM0 0 SM1 0 Mode 0 0 1 1 1 1. fOSC = oscillator frequency SM2 Enables the Automatic Address Recognition feature in Modes 2 or 3. If SM2 = 1 then RI will not be set unless the received 9th data bit (RB8) is 1, indicating an address, and the received byte is a given or broadcast address. In Mode 1, if SM2 = 1 then RI will not be activated unless a valid stop bit was received. In Mode 0, SM2 should be 0. REN Enables serial reception. 0: to disable reception. 1: to enable reception. TB8 The 9th data bit that will be transmitted in Modes 2 and 3. Set or clear by software as desired. RB8 In Modes 2 and 3, the 9th data bit that was received. In Mode 1, if SM2 = 0, RB8 is the stop bit that was received. In Mode 0, RB8 is not used. TI Transmit interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or at the beginning of the stop bit in the other modes, in any serial transmission, Must be cleared by software. RI Receive interrupt flag. Set by hardware at the end of the8th bit time in Mode 0, or halfway through the stop bit time in the other modes, in any serial reception (except see SM2). Must be cleared by software. ©2007 Silicon Storage Technology, Inc. S71255-08-000 32 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet Timer/Counter 2 Control Register (T2CON) Location 7 6 5 4 3 2 1 0 Reset Value C8H TF2 EXF2 RCLK TCLK EXEN2 TR2 C/T2# CP/RL2# 00H Symbol Function TF2 Timer 2 overflow flag set by a Timer 2 overflow and must be cleared by software. TF2 will not be set when either RCLK or TCLK = 1. EXF2 Timer 2 external flag set when either a capture or reload is caused by a negative transition on T2EX and EXEN2 = 1. When Timer 2 interrupt is enabled, EXF2 = 1 will cause the CPU to vector to the Timer 2 interrupt routine. EXF2 must be cleared by software. EXF2 does not cause an interrupt in up/down counter mode (DCEN = 1). RCLK Receive clock flag. When set, causes the serial port to use Timer 2 overflow pulses for its receive clock in modes 1 and 3. RCLK = 0 causes Timer 1 overflow to be used for the receive clock. TCLK Transmit clock flag. When set, causes the serial port to use Timer 2 overflow pulses for its transmit clock in modes 1 and 3. TCLK = 0 causes Timer 1 overflow to be used for the transmit clock. EXEN2 Timer 2 external enable flag. When set, allows a capture or reload to occur as a result of a negative transition on T2EX if Timer 2 is not being used to clock the serial port. EXEN2 = 0 causes Timer 2 to ignore events at T2EX. TR2 Start/stop control for Timer 2. A logic 1 starts the timer. C/T2# Timer or counter select (Timer 2) 0: Internal timer (OSC/6 in 6 clock mode, OSC/12 in 12 clock mode) 1: External event counter (falling edge triggered) CP/RL2# Capture/Reload flag. When set, captures will occur on negative transitions at T2EX if EXEN2 = 1. When cleared, auto-reloads will occur either with Timer 2 overflows or negative transitions at T2EX when EXEN2 = 1. When either RCLK = 1 or TCLK = 1, this bit is ignored and the timer is forced to auto-reload on Timer 2 overflow. Timer/Counter 2 Mode Control (T2MOD) Location 7 6 5 4 3 2 1 0 Reset Value C9H X - - - - - T2OE DCEN xxxxxx00b Symbol Function X Don’t Care - Not implemented, reserved for future use. Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate. T2OE Timer 2 Output Enable bit. DCEN Down Count Enable bit. When set, this allows Timer 2 to be configured as an up/down counter. ©2007 Silicon Storage Technology, Inc. S71255-08-000 33 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet External Interrupt Control (XICON) Location 7 6 5 4 3 2 1 0 Reset Value AEH X EX3 IE3 IT3 0 EX2 IE2 IT2 00H Symbol Function X Don’t Care EX2 External Interrupt 2 Enable bit if set IE2 Interrupt Enable If IT2=1, IE2 is set/cleared automatically by hardware when interrupt is detected/ serviced. IT2 External Interrupt 2 is falling-edge/low-level triggered when this bit is cleared by software. EX3 External Interrupt 3 Enable bit if set IE3 Interrupt Enable If IT3=1, IE3 is set/cleared automatically by hardware when interrupt is detected/ serviced. IT3 External Interrupt3 is falling-edge/low-level triggered when this bit is cleared by software. ©2007 Silicon Storage Technology, Inc. S71255-08-000 34 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 4.0 FLASH MEMORY PROGRAMMING 4.2.2 Memory Bank Selection for In-Application Programming Mode The device internal flash memory can be programmed or erased using the In-Application Programming (IAP) mode. With the addressing range limited to 16 bit, only 64 KByte of program address space is “visible” at any one time. The bank selection (the configuration of EA# and SFCF[1:0]), allows Block 1 memory to be overlaid on the lowest 8 KByte of Block 0 memory, making Block 1 reachable. The same concept is employed to allow both Block 0 and Block 1 flash to be accessible to IAP operations. Code from a block that is not visible may not be used as a source to program another address. However, a block that is not “visible” may be programmed by code from the other block through mailbox registers. 4.1 Product Identification The Read-ID command accesses the Signature Bytes that identify the device and the manufacturer as SST. External programmers primarily use these Signature Bytes in the selection of programming algorithms. TABLE 4-1: Product Identification Address Data 30H BFH SST89E54RD2/RD 31H 9FH SST89V54RD2/RD 31H 9EH SST89E58RD2/RD 31H 9BH SST89V58RD2/RD 31H Manufacturer’s ID The device allows IAP code in one block of memory to program the other block of memory, but may not program any location in the same block. If an IAP operation originates physically from Block 0, the target of this operation is implicitly defined to be in Block 1. If the IAP operation originates physically from Block 1, then the target address is implicitly defined to be in Block 0. If the IAP operation originates from external program space, then, the target will depend on the address and the state of bank selection. Device ID 9AH T4-1.2 1255 4.2 In-Application Programming Mode The device offers either 24/40 KByte of in-application programmable flash memory. During in-application programming, the CPU of the microcontroller enters IAP mode. The two blocks of flash memory allow the CPU to execute user code from one block, while the other is being erased or reprogrammed concurrently. The CPU may also fetch code from an external memory while all internal flash is being reprogrammed. The mailbox registers (SFST, SFCM, SFAL, SFAH, SFDT and SFCF) located in the special function register (SFR), control and monitor the device’s erase and program process. 4.2.3 IAP Enable Bit The IAP enable bit, SFCF[6], enables in-application programming mode. Until this bit is set, all flash programming IAP commands will be ignored. 4.2.4 In-Application Programming Mode Commands All of the following commands can only be initiated in the IAP mode. In all situations, writing the control byte to the SFCM register will initiate all of the operations. All commands will not be enabled if the security locks are enabled on the selected memory block. Table 4-2 outline the commands and their associated mailbox register settings. The Program command is for programming new data into the memory array. The portion of the memory array to be programmed should be in the erased state, FFH. If the memory is not erased, it should first be erased with an appropriate Erase command. Warning: Do not attempt to write (program or erase) to a block that the code is currently fetching from. This will cause unpredictable program behavior and may corrupt program data. 4.2.1 In-Application Programming Mode Clock Source During IAP mode, both the CPU core and the flash controller unit are driven off the external clock. However, an internal oscillator will provide timing references for Program and Erase operations. The internal oscillator is only turned on when required, and is turned off as soon as the flash operation is completed. ©2007 Silicon Storage Technology, Inc. S71255-08-000 35 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 4.2.4.1 Chip-Erase The Chip-Erase command erases all bytes in both memory blocks. This command is only allowed when EA#=0 (external memory execution). Additionally this command is not permitted when the device is in level 4 locking. In all other instances, this command ignores the Security Lock status and will erase the security lock bits and re-map bits. IAP Enable ORL SFCF, #40H Erase Block 0 MOV SFAH, #00H IAP Enable ORL SFCF, #40H Erase Block 1 MOV SFAH, #F0H OR Set-Up MOV SFDT, #55H Set-Up MOV SFDT, #55H Polling scheme MOV SFCM, #01H Interrupt scheme MOV SFCM, #81H SFST[2] indicates operation completion INT1 interrupt indicates completion Polling scheme MOV SFCM, #0DH Interrupt scheme MOV SFCM, #8DH SFST[2] indicates operation completion INT1 interrupt indicates completion 1255 F09.0 FIGURE 4.2.4.3 Sector-Erase The Sector-Erase command erases all of the bytes in a sector. The sector size for the flash memory blocks is 128 Bytes. The selection of the sector to be erased is determined by the contents of SFAH and SFAL. 1255 F08.0 FIGURE 4-2: Block-Erase 4-1: Chip-Erase 4.2.4.2 Block-Erase The Block-Erase command erases all bytes in one of the two memory blocks (Block 0 or Block 1). The selection of the memory block to be erased is determined by the (SFAH[7]) of the SuperFlash Address Register. For SST89x5xRD2/RD, if SFAH[7] = 0b, the primary flash memory Block 0 is selected. If SFAH[7:4] = EH, the secondary flash memory Block 1 is selected. The Block-Erase command sequence for SST89x5xRD2/RD is as follows: IAP Enable ORL SFCF, #40H Program sector address MOV SFAH, #sector_addressH MOV SFAL, #sector_addressL Polling scheme MOV SFCM, #0BH Interrupt scheme MOV SFCM, #8BH SFST[2] indicates operation completion INT1 interrupt indicates completion 1255 F10.0 FIGURE ©2007 Silicon Storage Technology, Inc. 4-3: Sector-Erase S71255-08-000 36 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 4.2.4.4 Byte-Program The Byte-Program command programs data into a single byte. The address is determined by the contents of SFAH and SFAL. The data byte is in SFDT. IAP Enable ORL SFCF, #40H Program byte address MOV SFAH, #byte_addressH MOV SFAL, #byte_addressL IAP Enable ORL SFCF, #40H Program byte address MOV SFAH, #byte_addressH MOV SFAL, #byte_addressL MOV SFCM, #0CH SFDT register contains data Move data to SFDT MOV SFDT, #data 1255 F12.0 FIGURE Polling scheme MOV SFCM, #0EH Interrupt scheme MOV SFCM, #8EH SFST[2] indicates operation completion INT1 interrupt indicates completion 4.2.4.6 Prog-SB3, Prog-SB2, Prog-SB1 Prog-SB3, Prog-SB2, Prog-SB1 commands are used to program the security bits (see Table 9-1). Completion of any of these commands, the security options will be updated immediately. Security bits previously in un-programmed state can be programmed by these commands. Prog-SB3, Prog-SB2 and Prog-SB1 commands should only reside in Block 1 or external code memory. 1255 F11.0 FIGURE 4-5: Byte-Verify 4-4: Byte-Program 4.2.4.5 Byte-Verify The Byte-Verify command allows the user to verify that the device has correctly performed an Erase or Program command. Byte-Verify command returns the data byte in SFDT if the command is successful. The user is required to check that the previous flash operation has fully completed before issuing a Byte-Verify. Byte-Verify command execution time is short enough that there is no need to poll for command completion and no interrupt is generated. IAP Enable ORL SFCF, #40H Set-Up MOV SFDT, #0AAH Program SB1 MOV SFCM, #0FH or MOV SFCM, #8FH OR Program SB2 MOV SFCM, #03H or OR Program SB3 MOV SFCM, #05H or MOV SFCM, #85H MOV SFCM, #83H Polling SFST[2] indicates completion INT1# Interrupt indicates completion 1255 F13.0 FIGURE ©2007 Silicon Storage Technology, Inc. 4-6: Prog-SB3, Prog-SB2, Prog-SB1 S71255-08-000 37 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 4.2.4.7 Prog-SC0, Prog-SC1 Prog-SC0 command is used to program the SC0 bit. This command only changes the SC0 bit and has no effect on BSEL bit until after a reset cycle. IAP Enable ORL SFCF, #40H SC0 bit previously in un-programmed state can be programmed by this command. The Prog-SC0 command should reside only in Block 1 or external code memory. Set-up Enable-Clock-Double MOV SFAH, #55H MOV SFDT, #0AAH Prog-SC1 command is used to program the SC1 bit. This command only changes the SC1 bit and has no effect on SFCF[1] bit until after a reset cycle. SC1 bit previously in un-programmed state can be programmed by this command. The Prog-SC1 command should reside only in Block 1 or external code memory. Program Enable-Clock-Double Polling scheme MOV SFCM, #08H Program Enable-Clock-Double Interrupt scheme MOV SFCM, #88H Polling SFST[2] indicates completion INT1# Interrupt indicates completion 1255 F15.0 FIGURE IAP Enable ORL SFCF, #40H 4-8: Enable-Clock-Double 4.2.5 Polling Set-up Program SC0 MOV SFAH, #5AH MOV SFDT, #0AAH Program SC0 or SC1 Polling scheme MOV SFCM, #09H Polling SFST[2] indicates completion A command that uses the polling method to detect flash operation completion should poll on the FLASH_BUSY bit (SFST[2]). When FLASH_BUSY de-asserts (logic 0), the device is ready for the next operation. Set-up Program SC1 MOV SFAH, #0AAH MOV SFDT, #0AAH MOVC instruction may also be used for verification of the Programming and Erase operation of the flash memory. MOVC instruction will fail if it is directed at a flash block that is still busy. Program SC0 or SC1 Interrupt scheme MOV SFCM, #89H 4.2.6 Interrupt Termination If interrupt termination is selected, (SFCM[7] is set), then an interrupt (INT1) will be generated to indicate flash operation completion. Under this condition, the INT1 becomes an internal interrupt source. The INT1# pin can now be used as a general purpose port pin and it cannot be the source of External Interrupt 1 during in-application programming. INT1# Interrupt indicates completion 1255 F14.0 FIGURE 4-7: Prog-SC0 and Prog-SC1 In order to use an interrupt to signal flash operation termination. EX1 and EA bits of IE register must be set. The IT1 bit of TCON register must also be set for edge trigger detection. 4.2.4.8 Enable-Clock-Double Enable-Clock-Double command is used to make the MCU run at 6 clocks per machine cycle. The standard (default) is 12 clocks per machine cycle (i.e. clock double command disabled). ©2007 Silicon Storage Technology, Inc. S71255-08-000 38 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 4-2: IAP Commands1 SFCM [6:0]2 Operation Chip-Erase3 SFDT [7:0] SFAH [7:0] SFAL [7:0] 55H X4 X X 01H Block-Erase 0DH 55H AH5 Sector-Erase 0BH X AH AL6 Byte-Program 0EH DI7 AH AL AH AL 0CH DO7 Prog-SB19 0FH AAH X X Prog-SB29 03H AAH X X Prog-SB39 05H AAH X X Prog-SC09 09H AAH 5AH X Prog-SC19 09H AAH AAH X Enable-Clock-Double9 08H AAH 55H X Byte-Verify (Read)8 T4-2.0 1255 1. SFCF[6]=1 enables IAP commands; SFCF[6]=0 disables IAP commands. 2. Interrupt/Polling enable for flash operation completion SFCM[7] = 1: Interrupt enable for flash operation completion 0: polling enable for flash operation completion 3. Chip-Erase only functions in IAP mode when EA#=0 (external memory execution) and device is not in level 4 locking. 4. X can be VIL or VIH, but no other value. 5. AH = Address high order byte 6. AL = Address low order byte 7. DI = Data Input, DO = Data Output, all other values are in hex. 8. SFAH[7:5] = 111b selects Block 1, SFAH[7] = 0b selects Block 0 9. Instruction must be located in Block 1 or external code memory. Note: DISIAPL pin in PLCC or TQFP will also disable IAP commands if it is externally pulled low when reset. 5.0 TIMERS/COUNTERS TABLE 5-1: Timer/Counter 0 TMOD 5.1 Timers The device has three 16-bit registers that can be used as either timers or event counters. The three timers/counters are denoted Timer 0 (T0), Timer 1 (T1), and Timer 2 (T2). Each is designated a pair of 8-bit registers in the SFRs. The pair consists of a most significant (high) byte and least significant (low) byte. The respective registers are TL0, TH0, TL1, TH1, TL2, and TH2. Used as Timer Used as Counter 5.2 Timer Set-up Refer to Table 3-8 for TMOD, TCON, and T2CON registers regarding timers T0, T1, and T2. The following tables provide TMOD values to be used to set up Timers T0, T1, and T2. Mode Function Internal Control1 External Control2 0 13-bit Timer 00H 08H 1 16-bit Timer 01H 09H 2 8-bit Auto-Reload 02H 0AH 3 Two 8-bit Timers 03H 0BH 0 13-bit Timer 04H 0CH 1 16-bit Timer 05H 0DH 2 8-bit Auto-Reload 06H 0EH 3 Two 8-bit Timers 07H 0FH T5-1.0 1255 1. The Timer is turned ON/OFF by setting/clearing bit TR0 in the software. 2. The Timer is turned ON/OFF by the 1 to 0 transition on INT0# (P3.2) when TR0 = 1 (hardware control). Except for the baud rate generator mode, the values given for T2CON do not include the setting of the TR2 bit. Therefore, bit TR2 must be set separately to turn the timer on. ©2007 Silicon Storage Technology, Inc. S71255-08-000 39 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 5.3 Programmable Clock-Out 5-2: Timer/Counter 1 TMOD Used as Timer Used as Counter Mode Function Internal Control1 External Control2 A 50% duty cycle clock can be programmed to come out on P1.0. This pin, besides being a regular I/O pin, has two alternate functions. It can be programmed: 0 13-bit Timer 00H 80H 1. to input the external clock for Timer/Counter 2, or 1 16-bit Timer 10H 90H 2 8-bit Auto-Reload 20H A0H 3 Does not run 30H B0H 0 13-bit Timer 40H C0H 1 16-bit Timer 50H D0H 2 8-bit Auto-Reload 60H E0H 3 Not available - 2. to output a 50% duty cycle clock ranging from 122 Hz to 8 MHz at a 16 MHz operating frequency (61 Hz to 4 MHz in 12 clock mode). To configure Timer/Counter 2 as a clock generator, bit C/#T2 (in T2CON) must be cleared and bit T20E in T2MOD must be set. Bit TR2 (T2CON.2) also must be set to start the timer. T5-2.0 1255 The Clock-Out frequency depends on the oscillator frequency and the reload value of Timer 2 capture registers (RCAP2H, RCAP2L) as shown in this equation: 1. The Timer is turned ON/OFF by setting/clearing bit TR1 in the software. 2. The Timer is turned ON/OFF by the 1 to 0 transition on INT1# (P3.3) when TR1 = 1 (hardware control). TABLE Oscillator Frequency n x (65536 - RCAP2H, RCAP2L) 5-3: Timer/Counter 2 n= T2CON Used as Timer Used as Counter Mode Internal Control1 External Control2 16-bit Auto-Reload 00H 08H 16-bit Capture 01H 09H Baud rate generator receive and transmit same baud rate 34H 36H Receive only 24H 26H Transmit only 14H 16H 16-bit Auto-Reload 02H 0AH 16-bit Capture 03H 0BH 2 (in 6 clock mode) 4 (in 12 clock mode) Where (RCAP2H, RCAP2L) = the contents of RCAP2H and RCAP2L taken as a 16-bit unsigned integer. In the Clock-Out mode, Timer 2 roll-overs will not generate an interrupt. This is similar to when it is used as a baud-rate generator. It is possible to use Timer 2 as a baud-rate generator and a clock generator simultaneously. Note, however, that the baud-rate and the Clock-Out frequency will not be the same. T5-3.0 1255 1. Capture/Reload occurs only on timer/counter overflow. 2. Capture/Reload occurs on timer/counter overflow and a 1 to 0 transition on T2EX (P1.1) pin except when Timer 2 is used in the baud rate generating mode. ©2007 Silicon Storage Technology, Inc. S71255-08-000 40 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 6.0 SERIAL I/O 6.1 Full-Duplex, Enhanced UART The device serial I/O port is a full-duplex port that allows data to be transmitted and received simultaneously in hardware by the transmit and receive registers, respectively, while the software is performing other tasks. The transmit and receive registers are both located in the Serial Data Buffer (SBUF) special function register. Writing to the SBUF register loads the transmit register, and reading from the SBUF register obtains the contents of the receive register. SCON register is set. Reception is initiated in the other modes by the incoming start bit if the REN bit of the SCON register is set. The UART has four modes of operation which are selected by the Serial Port Mode Specifier (SM0 and SM1) bits of the Serial Port Control (SCON) special function register. In all four modes, transmission is initiated by any instruction that uses the SBUF register as a destination register. Reception is initiated in mode 0 when the Receive Interrupt (RI) flag bit of the Serial Port Control (SCON) SFR is cleared and the Reception Enable/ Disable (REN) bit of the Framing Error Detection is selected by going to the PCON register and changing SMOD0 = 1 (see Figure 6-1). If a stop bit is missing, the Framing Error bit (FE) will be set. Software may examine the FE bit after each reception to check for data errors. After the FE bit has been set, it can only be cleared by software. Valid stop bits do not clear FE. When FE is enabled, RI rises on the stop bit, instead of the last data bit (see Figure 6-2 and Figure 6-3). SM0/FE SM1 SM2 REN TB8 6.1.1 Framing Error Detection Framing Error Detection is a feature, which allows the receiving controller to check for valid stop bits in modes 1, 2, or 3. Missing stops bits can be caused by noise in serial lines or from simultaneous transmission by two CPUs. RB8 TI RI SCON (98H) Set FE bit if stop bit is 0 (framing error) (SMOD0 = 1) SM0 to UART mode control (SMOD0 = 0) SMOD1 SMOD0 BOF POF GF1 GF0 PD IDL PCON (87H) To UART framing error control 1255 F16.0 FIGURE 6-1: Framing Error Block Diagram ©2007 Silicon Storage Technology, Inc. S71255-08-000 41 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet RXD D0 D1 D2 D3 Start bit D4 D5 D6 D7 Data byte Stop bit RI SMOD0=X FE SMOD0=1 1255 F17.0 FIGURE 6-2: UART Timings in Mode 1 RXD D0 D1 D2 D3 Start bit D4 Data byte D5 D6 D7 D8 Ninth bit Stop bit RI SMOD0=0 RI SMOD0=1 FE SMOD0=1 1255 F18.0 FIGURE 6-3: UART Timings in Modes 2 and 3 ©2007 Silicon Storage Technology, Inc. S71255-08-000 42 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 6.1.2 Automatic Address Recognition Slave 2 Automatic Address Recognition helps to reduce the MCU time and power required to talk to multiple serial devices. Each device is hooked together sharing the same serial link with its own address. In this configuration, a device is only interrupted when it receives its own address, thus eliminating the software overhead to compare addresses. 1111 0011 SADEN = 1111 1001 GIVEN = 1111 0XX1 6.1.2.1 Using the Given Address to Select Slaves Any bits masked off by a 0 from SADEN become a “don’t care” bit for the given address. Any bit masked off by a 1, becomes ANDED with SADDR. The “don’t cares” provide flexibility in the user-defined addresses to address more slaves when using the given address. This same feature helps to save power because it can be used in conjunction with idle mode to reduce the system’s overall power consumption. Since there may be multiple slaves hooked up serial to one master, only one slave would have to be interrupted from idle mode to respond to the master’s transmission. Automatic Address Recognition (AAR) allows the other slaves to remain in idle mode while only one is interrupted. By limiting the number of interruptions, the total current draw on the system is reduced. Shown in the example above, Slave 1 has been given an address of 1111 0001 (SADDR). The SADEN byte has been used to mask off bits to a given address to allow more combinations of selecting Slave 1 and Slave 2. In this case for the given addresses, the last bit (LSB) of Slave 1 is a “don’t care” and the last bit of Slave 2 is a 1. To communicate with Slave 1 and Slave 2, the master would need to send an address with the last bit equal to 1 (e.g. 1111 0001) since Slave 1’s last bit is a don’t care and Slave 2’s last bit has to be a 1. To communicate with Slave 1 alone, the master would send an address with the last bit equal to 0 (e.g. 1111 0000), since Slave 2’s last bit is a 1. See the table below for other possible combinations. There are two ways to communicate with slaves: a group of them at once, or all of them at once. To communicate with a group of slaves, the master sends out an address called the given address. To communicate with all the slaves, the master sends out an address called the “broadcast” address. AAR can be configured as mode 2 or 3 (9-bit modes) and setting the SM2 bit in SCON. Each slave has its own SM2 bit set waiting for an address byte (9th bit = 1). The Receive Interrupt (RI) flag will only be set when the received byte matches either the given address or the broadcast address. Next, the slave then clears its SM2 bit to enable reception of the data bytes (9th bit = 0) from the master. When the 9th bit = 1, the master is sending an address. When the 9th bit = 0, the master is sending actual data. Select Slave 1 Only Slave 1 If mode 1 is used, the stop bit takes the place of the 9th bit. Bit RI is set only when the received command frame address matches the device’s address and is terminated by a valid stop bit. Note that mode 0 cannot be used. Setting SM2 bit in the SCON register in mode 0 will have no effect. Given Address Possible Addresses 1111 0X0X 1111 0000 1111 0100 Select Slave 2 Only Slave 2 Given Address Possible Addresses 1111 0XX1 1111 0111 1111 0011 Select Slaves 1 and 2 Each slave’s individual address is specified by SFR SADDR. SFR SADEN is a mask byte that defines “don’t care” bits to form the given address when combined with SADDR. See the example below: Slaves 1 and 2 Possible Addresses 1111 0001 1111 0101 If the user added a third slave such as the example below: Slave 1 SADDR = 1111 0001 SADEN = 1111 1010 GIVEN SADDR = Slave 3 SADDR = 1111 1001 = 1111 0X0X SADEN = 1111 0101 GIVEN ©2007 Silicon Storage Technology, Inc. = 1111 X0X1 S71255-08-000 43 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 6.2 Serial Peripheral Interface The user could use the possible addresses above to select slave 3 only. Another combination could be to select slave 2 and 3 only as shown below. 6.2.1 SPI Features • • • • • • • Select Slaves 2 and 3 Only Slaves 2 and 3 Possible Addresses 1111 0011 More than one slave may have the same SADDR address as well, and a given address could be used to modify the address so that it is unique. Master or slave operation 10 MHz bit frequency (max) LSB first or MSB first data transfer Four programmable bit rates End of transmission (SPIF) Write collision flag protection (WCOL) Wake up from idle mode (slave mode only) 6.2.2 SPI Description 6.1.2.2 Using the Broadcast Address to Select Slaves Using the broadcast address, the master can communicate with all the slaves at once. It is formed by performing a logical OR of SADDR and SADEN with ‘0’s in the result treated as “don’t cares”. The serial peripheral interface (SPI) allows high-speed synchronous data transfer between the SST89E/V5xRDx and peripheral devices or between several SST89E/V5xRDx devices. Figure 6-4 shows the correspondence between master and slave SPI devices. The SCK pin is the clock output and input for the master and slave modes, respectively. The SPI clock generator will start following a write to the master devices SPI data register. The written data is then shifted out of the MOSI pin on the master device into the MOSI pin of the slave device. Following a complete transmission of one byte of data, the SPI clock generator is stopped and the SPIF flag is set. An SPI interrupt request will be generated if the SPI Interrupt Enable bit (SPIE) and the Serial Port Interrupt Enable bit (ES) are both set. Slave 1 1111 0001 = SADDR +1111 1010 = SADEN 1111 1X11 = Broadcast “Don’t cares” allow for a wider range in defining the broadcast address, but in most cases, the broadcast address will be FFH. On reset, SADDR and SADEN are “0”. This produces an given address of all “don’t cares” as well as a broadcast address of all “don’t cares.” This effectively disables Automatic Addressing mode and allows the microcontroller to function as a standard 8051, which does not make use of this feature. An external master drives the Slave Select input pin, SS#/ P1[4], low to select the SPI module as a slave. If SS#/P1[4] has not been driven low, then the slave SPI unit is not active and the MOSI/P1[5] port can also be used as an input port pin. CPHA and CPOL control the phase and polarity of the SPI clock. Figures 6-5 and 6-6 show the four possible combinations of these two bits. MSB Master LSB MISO MISO 8-bit Shift Register MSB Slave LSB 8-bit Shift Register MOSI MOSI SPI Clock Generator SCK SCK SS# SS# VDD VSS FIGURE 1255 F19.0 6-4: SPI Master-slave Interconnection ©2007 Silicon Storage Technology, Inc. S71255-08-000 44 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 6.2.3 SPI Transfer Formats SCK Cycle # (for reference) 1 2 3 4 5 6 7 8 SCK (CPOL=0) SCK (CPOL=1) MOSI (from Master) MISO (from Slave) MSB MSB 6 5 4 3 2 1 LSB 6 5 4 3 2 1 LSB SS# (to Slave) 1255 F20.0 FIGURE 6-5: SPI Transfer Format with CPHA = 0 SCK Cycle # (for reference) 1 2 3 4 5 6 7 8 SCK (CPOL=0) SCK (CPOL=1) MOSI (from Master) MSB 6 5 4 3 2 1 MISO (from Slave) MSB 6 5 4 3 2 1 LSB LSB SS# (to Slave) 1255 F21.0 FIGURE 6-6: SPI Transfer Format with CPHA = 1 ©2007 Silicon Storage Technology, Inc. S71255-08-000 45 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 7.0 WATCHDOG TIMER The device offers a programmable Watchdog Timer (WDT) for fail safe protection against software deadlock and automatic recovery. The WDTS flag bit is set by WDT overflow and is not changed by WDT reset. User software can clear WDTS by writing “1” to it. To protect the system against software deadlock, the user software must refresh the WDT within a user-defined time period. If the software fails to do this periodical refresh, an internal hardware reset will be initiated if enabled (WDRE= 1). The software can be designed such that the WDT times out if the program does not work properly. Figure 7-1 provides a block diagram of the WDT. Two SFRs (WDTC and WDTD) control watchdog timer operation. During idle mode, WDT operation is temporarily suspended, and resumes upon an interrupt exit from idle. The time-out period of the WDT is calculated as follows: Period = (255 - WDTD) * 344064 * 1/fCLK (XTAL1) The WDT in the device uses the system clock (XTAL1) as its time base. So strictly speaking, it is a watchdog counter rather than a watchdog timer. The WDT register will increment every 344,064 crystal clocks. The upper 8-bits of the time base register (WDTD) are used as the reload register of the WDT. CLK (XTAL1) Counter where WDTD is the value loaded into the WDTD register and fOSC is the oscillator frequency. 344064 clks WDT Reset WDT Upper Byte Internal Reset Ext. RST WDTC WDTD 1255 F22.0 FIGURE 7-1: Block Diagram of Programmable Watchdog Timer ©2007 Silicon Storage Technology, Inc. S71255-08-000 46 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 8.0 PROGRAMMABLE COUNTER ARRAY PCA. External events associated with modules are shared with corresponding Port 1 pins. Modules not using the port pins can still be used for standard I/O. The Programmable Counter Array (PCA) present on the SST89E/V5xRD2/RD is a special 16-bit timer that has five 16-bit capture/compare modules. Each of the modules can be programmed to operate in one of four modes: rising and/or falling edge capture, software timer, high-speed output, or pulse width modulator. The 5th module can be programmed as a Watchdog Timer in addition to the other four modes. Each module has a pin associated with it in port 1. Module 0 is connected to P1.3 (CEX0), module 1 to P1[4] (CEX1), module 2 to P1[5] (CEX2), module 3 to P1[6] (CEX3), and module 4 to P1[7] (CEX4). PCA configuration is shown in Figure 8-1. Each of the five modules can be programmed in any of the following modes: • • • • • 8.2 PCA Timer/Counter 8.1 PCA Overview The PCA timer is a free-running 16-bit timer consisting of registers CH and CL (the high and low bytes of the count values). The PCA timer is common time base for all five modules and can be programmed to run at: 1/6 the oscillator frequency, 1/2 the oscillator frequency, Timer 0 overflow, or the input on the ECI pin (P1.2). The timer/counter source is determined from the CPS1 and CPS0 bits in the CMOD SFR as follows (see “PCA Timer/Counter Mode Register (CMOD)” on page 28): PCA provides more timing capabilities with less CPU intervention than the standard timer/counter. Its advantages include reduced software overhead and improved accuracy. The PCA consists of a dedicated timer/counter which serves as the time base for an array of five compare/capture modules. Figure 8-1 shows a block diagram of the TABLE Rising and/or falling edge capture Software timer High speed output Watchdog Timer (Module 4 only) Pulse Width Modulator (PWM) 8-1: PCA Timer/Counter Source CPS1 CPS0 12 Clock Mode 6 Clock Mode 0 0 fOSC /12 fOSC /6 0 1 fOSC /4 fOSC /2 1 0 Timer 0 overflow Timer 0 overflow 1 1 External clock at ECI pin (maximum rate = fOSC /8) External clock at ECI pin (maximum rate = fOSC /4) T8-1.0 1255 16 Bits Each Module 0 P1.3/CEX0 Module 1 P1.4/CEX1 Module 2 P1.5/CEX2 Module 3 P1.6/CEX3 Module 4 P1.7/CEX4 16 Bits PCA Timer/Counter 1255 F23.0 FIGURE 8-1: PCA Timer/Counter and Compare/Capture Modules ©2007 Silicon Storage Technology, Inc. S71255-08-000 47 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet The table below summarizes various clock inputs at two common frequencies. TABLE 8-2: PCA Timer/Counter Inputs Clock Increments PCA Timer/Counter Mode 12 MHz 16 MHz Mode 0: fOSC/12 1 µsec 0.75 µsec 330 nsec 250 nsec 8-bit mode 256 µsec 192 µsec 16-bit mode 65 msec 49 µsec 1 to 255 µsec 0.75 to 191 µsec 0.66 µsec 0.50 µsec Mode 1: Mode 2: Timer 0 Overflows1 Timer 0 programmed in: 8-bit auto-reload Mode 3: External Input MAX T8-2.0 1255 1. In Mode 2, the overflow interrupt for Timer 0 does not need to be enabled. The four possible CMOD timer modes with and without the overflow interrupt enabled are shown below. This list assumes that PCA will be left running during idle mode. TABLE 8-3: CMOD Values CMOD Value PCA Count Pulse Selected Without Interrupt Enabled With Interrupt Enabled Internal clock, fOSC/12 00H 01H Internal clock, fOSC/4 02H 03H Timer 0 overflow 04H 05H External clock at P1.2 06H 07H T8-3.0 1255 The CCON register is associated with all PCA timer functions. It contains run control bits and flags for the PCA timer (CF) and all modules. To run the PCA the CR bit (CCON.6) must be set by software. Clearing the bit, will turn off PCA. When the PCA counter overflows, the CF (CCON.7) will be set, and an interrupt will be generated if the ECF bit in the CMOD register is set. The CF bit can only be cleared by software. Each module has its own timer interrupt or capture interrupt flag (CCF0 for module 0, CCF4 for module 4, etc.). They are set when either a match or capture occurs. These flags can only be cleared by software. (See “PCA Timer/Counter Control Register (CCON)” on page 27.) ©2007 Silicon Storage Technology, Inc. S71255-08-000 48 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 8.3 Compare/Capture Modules Bits CAPN (CCAPMn.4) and CAPP (CCAPMn.5) determine whether the capture input will be active on a positive edge or negative edge. The CAPN bit enables the negative edge that a capture input will be active on, and the CAPP bit enables the positive edge. When both bits are set, both edges will be enabled and a capture will occur for either transition. The last bit in the register ECOM (CCAPMn.6) when set, enables the comparator function. Table 8-5 shows the CCAPMn settings for the various PCA functions. Each PCA module has an associated SFR with it. These registers are: CCAPM0 for module 0, CCAPM1 for module 1, etc. Refer to “PCA Compare/Capture Module Mode Register (CCAPMn)” on page 29 for details. The registers each contain 7 bits which are used to control the mode each module will operate in. The ECCF bit (CCAPMn.0 where n = 0, 1, 2, 3, or 4 depending on module) will enable the CCF flag in the CCON SFR to generate an interrupt when a match or compare occurs. PWM (CCAPMn.1) enables the pulse width modulation mode. The TOG bit (CCAPMn.2) when set, causes the CEX output associated with the module to toggle when there is a match between the PCA counter and the module’s capture/compare register. When there is a match between the PCA counter and the module’s capture/compare register, the MATn (CCAPMn.3) and the CCFn bit in the CCON register to be set. TABLE Symbol There are two additional register associated with each of the PCA modules: CCAPnH and CCAPnL. They are registers that hold the 16-bit count value when a capture occurs or a compare occurs. When a module is used in PWM mode, these registers are used to control the duty cycle of the output. See Figure 8-1. 8-4: PCA High and Low Register Compare/Capture Modules Description Direct Address MSB Bit Address, Symbol, or Alternative Port Function LSB RESET Value CCAP0H PCA Module 0 Compare/Capture CCAP0L Registers FAH CCAP0H[7:0] 00H EAH CCAP0L[7:0] 00H CCAP1H PCA Module 1 Compare/Capture CCAP1L Registers FBH CCAP1H[7:0] 00H EBH CCAP1L[7:0] 00H FCH CCAP2H[7:0] 00H ECH CCAP2L[7:0] 00H FDH CCAP3H[7:0] 00H EDH CCAP3L[7:0] 00H FEH CCAP4H[7:0] 00H EEH CCAP4L[7:0] 00H CCAP2H PCA Module 2 Compare/Capture CCAP2L Registers CCAP3H PCA Module 3 Compare/Capture CCAP3L Registers CCAP4H PCA Module 4 Compare/Capture CCAP4L Registers T8-4.0 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 49 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 8-5: PCA Module Modes Without Interrupt enabled -1 ECOMy2 CAPPy2 CAPNy2 MATy2 TOGy2 PWMy2 ECCFy2 Module Code - 0 0 0 0 0 0 0 No Operation - 0 1 0 0 0 0 0 16-bit capture on positive-edge trigger at CEX[4:0] - 0 0 1 0 0 0 0 16-bit capture on negative-edge trigger at CEX[4:0] - 0 1 1 0 0 0 0 16-bit capture on positive/negative-edge trigger at CEX[4:0] - 1 0 0 1 0 0 0 Compare: software timer - 1 0 0 1 1 0 0 Compare: high-speed output - 1 0 0 0 0 1 0 Compare: 8-bit PWM - 1 0 0 1 0 or 13 0 0 Compare: PCA WDT (CCAPM4 only)4 T8-5.0 1255 1. 2. 3. 4. User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate. y = 0, 1, 2, 3, 4 A 0 disables toggle function. A 1 enables toggle function on CEX[4:0] pin. For PCA WDT mode, also set the WDTE bit in the CMOD register to enable the reset output signal. TABLE 8-6: PCA Module Modes With Interrupt enabled -1 ECOMy2 CAPPy2 CAPNy2 MATy2 TOGy2 PWMy2 ECCFy2 Module Code - 0 1 0 0 0 0 1 16-bit capture on positive-edge trigger at CEX[4:0] - 0 0 1 0 0 0 1 16-bit capture on negative-edge trigger at CEX[4:0] - 0 1 1 0 0 0 1 16-bit capture on positive/negative-edge trigger at CEX[4:0] - 1 0 0 1 0 0 1 Compare: software timer - 1 0 0 1 1 0 1 Compare: high-speed output - 1 0 0 0 0 1 X3 Compare: 8-bit PWM - 1 0 0 1 0 or 14 0 X5 Compare: PCA WDT (CCAPM4 only)6 T8-6.0 1255 1. 2. 3. 4. 5. 6. User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate. y = 0, 1, 2, 3, 4 No PCA interrupt is needed to generate the PWM. A 0 disables toggle function. A 1 enables toggle function on CEX[4:0] pin. Enabling an interrupt for the Watchdog Timer would defeat the purpose of the Watchdog Timer. For PCA WDT mode, also set the WDTE bit in the CMOD register to enable the reset output signal. ©2007 Silicon Storage Technology, Inc. S71255-08-000 50 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 8.3.1 Capture Mode and CL) into the module’s capture registers (CCAPnL and CCAPnH). If the CCFn bit for the module in the CCON SFR and the ECCFn bit in the CCAPMn SFR are set, then an interrupt will be generated. In the interrupt service routine, the 16-bit capture value must be saved in RAM before the next event capture occurs. If a subsequent capture occurred, the original capture values would be lost. After flag event flag has been set by hardware, the user must clear the flag in software. (See Figure 8-2) Capture mode is used to capture the PCA timer/counter value into a module’s capture registers (CCAPnH and CCAPnL). The capture will occur on a positive edge, negative edge, or both on the corresponding module’s pin. To use one of the PCA modules in the capture mode, either one or both the CCAPM bits CAPN and CAPP for that module must be set. When a valid transition occurs on the CEX pin corresponding to the module used, the PCA hardware loads the 16-bit value of the PCA counter register (CH CCON CF CR CCF4 CCF3 CCF2 CCF1 CCF0 PCA Interrupt PCA Timer/Counter CL CCAPnH CCAPnL Capture CEXn CCAPMn n=0 to 4 ECOMn CAPPn CAPNn MATn 0 FIGURE CH 0 TOGn 0 PWMn ECCFn 1255 F24.0 0 8-2: PCA Capture Mode ©2007 Silicon Storage Technology, Inc. S71255-08-000 51 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet If necessary, a new 16-bit compare value can be loaded into CCAPnH and CCAPnL during the interrupt routine. The user should be aware that the hardware temporarily disables the comparator function while these registers are being updated so that an invalid match will not occur. Thus, it is recommended that the user write to the low byte first (CCAPnL) to disable the comparator, then write to the high byte (CCAPnH) to re-enable it. If any updates to the registers are done, the user may want to hold off any interrupts from occurring by clearing the EA bit. (See Figure 8-3) 8.3.2 16-Bit Software Timer Mode The 16-bit software timer mode is used to trigger interrupt routines, which must occur at periodic intervals. It is setup by setting both the ECOM and MAT bits in the module’s CCAPMn register. The PCA timer will be compared to the module’s capture registers (CCAPnL and CCAPnH) and when a match occurs, an interrupt will occur, if the CCFn (CCON SFR) and the ECCFn (CCAPMn SFR) bits for the module are both set. CF Write to CCAPnL CCF4 CCF3 CCF2 CCF1 CCF0 CCON Reset Write to CCAPnH 1 CR CCAPnH PCA Interrupt CCAPnL 0 Enable Match 16-bit Comparator CH CL PCA Timer/Counter ECOMn CAPPn CAPNn 0 0 MATn TOGn 0 PWMn ECCFn CCAPMn n=0 to 4 0 1255 F25.0 FIGURE 8-3: PCA Compare Mode (Software Timer) ©2007 Silicon Storage Technology, Inc. S71255-08-000 52 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet High speed output mode is much more accurate than toggling pins since the toggle occurs before branching to an interrupt. In this case, interrupt latency will not affect the accuracy of the output. When using high speed output, using an interrupt is optional. Only if the user wishes to change the time for the next toggle is it necessary to update the compare registers. Otherwise, the next toggle will occur when the PCA timer rolls over and matches the last compare value. (See Figure 8-4) 8.3.3 High Speed Output Mode The high speed output mode is used to toggle a port pin when a match occurs between the PCA timer and the preloaded value in the compare registers. In this mode, the CEX output pin (on port 1) associated with the PCA module will toggle every time there is a match between the PCA counter (CH and CL) and the capture registers (CCAPnH and CCAPnL). To activate this mode, the user must set TOG, MAT, and ECOM bits in the module’s CCAPMn SFR. CF Write to CCAPnL CCF4 CCF3 CCF2 CCF1 CCF0 CCON Reset Write to CCAPnH 1 CR CCAPnH PCA Interrupt CCAPnL 0 Enable Match 16-bit Comparator Toggle CH CEXn CL PCA Timer/Counter ECOMn CAPPn CAPNn 0 0 MATn TOGn PWMn ECCFn CCAPMn n=0 to 4 0 1255 F26.0 FIGURE 8-4: PCA High Speed Output Mode ©2007 Silicon Storage Technology, Inc. S71255-08-000 53 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 8.3.4 Pulse Width Modulator loaded into the high byte (CCAPnH). Since writes to the CCAPnH register are asynchronous, a new value written to the high byte will not be shifted into CCAPnL for comparison until the next period of the output (when CL rolls over from 255 to 00). The Pulse Width Modulator (PWM) mode is used to generate 8-bit PWMs by comparing the low byte of the PCA timer (CL) with the low byte of the compare register (CCAPnL). When CL < CCAPnL the output is low. When CL ≥ CCAPnL the output is high. To activate this mode, the user must set the PWM and ECOM bits in the module’s CCAPMn SFR. (See Figure 8-5 and Table 8-7) To calculate values for CCAPnH for any duty cycle, use the following equation: In PWM mode, the frequency of the output depends on the source for the PCA timer. Since there is only one set of CH and CL registers, all modules share the PCA timer and frequency. Duty cycle of the output is controlled by the value CCAPnH = 256(1 - Duty Cycle) where CCAPnH is an 8-bit integer and Duty Cycle is a fraction. CCAPnH CCAPnL 0 CL < CCAPnL Enable 8-bit Comparator CEXn CL >= CCAPnL 1 CL Overflow PCA Timer/Counter FIGURE TABLE ECOMn CAPPn CAPNn MATn TOGn 0 0 0 0 PWMn ECCFn CCAPMn n=0 to 4 0 1255 F27.0 8-5: PCA Pulse Width Modulator Mode 8-7: Pulse Width Modulator Frequencies PWM Frequency PCA Timer Mode 12 MHz 16 MHz 1/12 Oscillator Frequency 3.9 KHz 5.2 KHz 1/4 Oscillator Frequency 11.8 KHz 15.6 KHz 15.5 Hz 20.3 Hz Timer 0 Overflow: 8-bit 16-bit 8-bit Auto-Reload External Input (Max) 0.06 Hz 0.08 Hz 3.9 KHz to 15.3 Hz 5.2 KHz to 20.3 Hz 5.9 KHz 7.8 KHz T8-7.0 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 54 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet Use the code below to initialize the Watchdog Timer. Module 4 can be configured in either compare mode, and the WDTE bit in CMOD must also be set. The user’s software then must periodically change (CCAP4H, CCAP4L) to keep a match from occurring with the PCA timer (CH, CL). This code is given in the Watchdog routine below. 8.3.5 Watchdog Timer The Watchdog Timer mode is used to improve reliability in the system without increasing chip count (See Figure 8-6). Watchdog Timers are useful for systems that are susceptible to noise, power glitches, or electrostatic discharge. It can also be used to prevent a software deadlock. If during the execution of the user’s code, there is a deadlock, the Watchdog Timer will time out and an internal reset will occur. Only module 4 can be programmed as a Watchdog Timer (but still can be programmed to other modes if the Watchdog Timer is not used). ;============================================== Init_Watchdog: MOVCCAPM4, #4CH; Module 4 in compare mode MOVCCAP4L, #0FFH; Write to low byte first To use the Watchdog Timer, the user pre-loads a 16-bit value in the compare register. Just like the other compare modes, this 16-bit value is compared to the PCA timer value. If a match is allowed to occur, an internal reset will be generated. This will not cause the RST pin to be driven high. MOVCCAP4H, #0FFH; Before PCA timer counts up ; to FFFF Hex, these compare ; values must be changed. ORLCMOD, #40H; Set the WDTE bit to enable the ; watchdog timer without ; changing the other bits in ; CMOD In order to hold off the reset, the user has three options: ;============================================== 1. periodically change the compare value so it will never match the PCA timer, ;Main program goes here, but call WATCHDOG periodically. 2. periodically change the PCA timer value so it will never match the compare values, or WATCHDOG: ;============================================== CLR EA; Hold off interrupts 3. disable the watchdog timer by clearing the WDTE bit before a match occurs and then re-enable it. MOVCCAP4L, #00; Next compare value is within MOVCCAP4H, CH; 65,535 counts of the ; current PCA The first two options are more reliable because the Watchdog Timer is never disabled as in option #3. If the program counter ever goes astray, a match will eventually occur and cause an internal reset. The second option is also not recommended if other PCA modules are being used. Remember, the PCA timer is the time base for all modules; changing the time base for other modules would not be a good idea. Thus, in most application the first solution is the best option. CIDL Write to CCAP4L RET ;============================================== This routine should not be part of an interrupt service routine. If the program counter goes astray and gets stuck in an infinite loop, interrupts will still be serviced and the watchdog will keep getting reset. Thus, the purpose of the watchdog would be defeated. Instead, call this subroutine from the main program of the PCA timer. WDTE CPS1 CPS0 ECF CMOD Reset Write to CCAP4H 1 SETBEA; timer value CCAP4H CCAP4L Module 4 0 Enable Match 16-bit Comparator CH Reset CL PCA Timer/Counter ECOMn CAPPn CAPNn MATn TOGn 0 1 X 0 PWMn ECCFn 0 CCAPM4 X 1255 F28.0 FIGURE 8-6: PCA Watchdog Timer (Module 4 only) ©2007 Silicon Storage Technology, Inc. S71255-08-000 55 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 9.0 SECURITY LOCK issued through the command mailbox register, SFCM, executed from a Locked (hard locked or soft locked) block, can be operated on a soft locked block: Block-Erase, SectorErase, Byte-Program and Byte-Verify. The security lock protects against software piracy and prevents the contents of the flash from being read by unauthorized parties. It also protects against code corruption resulting from accidental erasing and programming to the internal flash memory. There are two different types of security locks in the device security lock system: hard lock and SoftLock. In external host mode, SoftLock behaves the same as a hard lock. 9.3 Security Lock Status 9.1 Hard Lock The three bits that indicate the device security lock status are located in SFST[7:5]. As shown in Figure 91 and Table 9-1, the three security lock bits control the lock status of the primary and secondary blocks of memory. There are four distinct levels of security lock status. In the first level, none of the security lock bits are programmed and both blocks are unlocked. In the second level, although both blocks are now locked and cannot be programmed, they are available for read operation via Byte-Verify. In the third level, three different options are available: Block 1 hard lock / Block 0 SoftLock, SoftLock on both blocks, and hard lock on both blocks. Locking both blocks is the same as Level 2, Block 1 except read operation isn’t available. The fourth level of security is the most secure level. It doesn’t allow read/program of internal memory or boot from external memory. For details on how to program the security lock bits refer to the external host mode and in-application programming sections. When hard lock is activated, MOVC or IAP instructions executed from an unlocked or soft locked program address space, are disabled from reading code bytes in hard locked memory blocks (See Table 9-2). Hard lock can either lock both flash memory blocks or just lock the 8 KByte flash memory block (Block 1). All external host and IAP commands except for Chip-Erase are ignored for memory blocks that are hard locked. 9.2 SoftLock SoftLock allows flash contents to be altered under a secure environment. This lock option allows the user to update program code in the soft locked memory block through inapplication programming mode under a predetermined secure environment. For example, if Block 1 (8K) memory block is locked (hard locked or soft locked), and Block 0 memory block is soft locked, code residing in Block 1 can program Block 0. The following IAP mode commands UUU/NN Level 1 PUU/SS Level 2 UPU/SS UUP/LS Level 3 UPP/LL PPU/LS PUP/LL UPP/LL Level 4 PPP/LL 1255 F29.0 FIGURE Note: 9-1: Security Lock Levels P = Programmed (Bit logic state = 0), U = Unprogrammed (Bit logic state = 1), N = Not Locked, L = Hard locked, S = Soft locked ©2007 Silicon Storage Technology, Inc. S71255-08-000 56 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 9-1: Security Lock Options Security Lock Bits1,2 Security Status of: Level SFST[7:5] SB1 SB21 1 000 U U U Unlock Unlock No Security Features are Enabled. 2 100 P U U SoftLock SoftLock MOVC instructions executed from external program memory are disabled from fetching code bytes from internal memory, EA# is sampled and latched on Reset, and further programming of the flash is disabled. 3 011 101 U P P U P P Hard Lock Hard Lock Level 2 plus Verify disabled, both blocks locked. 010 U P U SoftLock SoftLock Level 2 plus Verify disabled. Code in Block 1 may program Block 0 and vice versa. 110 001 P U P U U P Hard Lock SoftLock Level 2 plus Verify disabled. Code in Block 1 may program Block 0. 111 P P P Hard Lock Hard Lock Same as Level 3 hard lock/hard lock, but MCU will start code execution from the internal memory regardless of EA#. 4 SB31 Block 1 Block 0 Security Type T9-1.0 1255 1. P = Programmed (Bit logic state = 0), U = Unprogrammed (Bit logic state = 1). 2. SFST[7:5] = Security Lock Status Bits (SB1_i, SB2_i, SB3_i) 9.4 Read Operation Under Lock Condition The status of security bits SB1, SB2, and SB3 can be read when the read command is disabled by security lock. There are three ways to read the status. 1. External host mode: Read-back = 00H (locked) 2. IAP command: Read-back = previous SFDT data 3. MOVC: Read-back = FFH (blank) ©2007 Silicon Storage Technology, Inc. S71255-08-000 57 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE Level 9-2: Security Lock Access Table SFST[7:5] Source Address1 Block 0/1 4 111b (hard lock on both blocks) External Block 0/1 011b/101b (hard lock on both blocks) External Block 0 001b/110b (Block 0 = SoftLock, Block 1 = hard lock) Block 1 3 External Block 0 010b (SoftLock on both blocks) Block 1 External Block 0 2 100b (SoftLock on both blocks) Block 1 External Block 0 1 000b (unlock) Block 1 External Byte-Verify Allowed MOVC Allowed Target Address2 External IAP 5xRDx Block 0/1 N N Y Host3 External N/A N/A Y Block 0/1 N N N External N/A N/A Y Block 0/1 N N Y External N/A N/A Y Block 0/1 N N N External N/A N/A Y Block 0 N N Y Block 1 N N N External N/A N/A Y Block 0 N Y Y Block 1 N N Y External N/A N/A Y Block 0/1 N N N External N/A N/A Y Block 0 N N Y Y Block 1 N Y External N/A N/A Y Block 0 N Y Y Block 1 N N Y External N/A N/A Y Block 0/1 N N N External N/A N/A Y Block 0 Y N Y Block 1 Y Y Y External N/A N/A Y Block 0 Y Y Y Block 1 Y N Y External N/A N/A Y Block 0/1 Y N N External N/A N/A Y Block 0 Y N Y Block 1 Y Y Y External N/A N/A Y Block 0 Y Y Y Block 1 Y N Y External N/A N/A Y Block 0/1 Y Y Y External N/A N/A Y T9-2.0 1255 1. Location of MOVC or IAP instruction 2. Target address is the location of the byte being read 3. External host Byte-Verify access does not depend on a source address. ©2007 Silicon Storage Technology, Inc. S71255-08-000 58 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 10.0 RESET VDD A system reset initializes the MCU and begins program execution at program memory location 0000H. The reset input for the device is the RST pin. In order to reset the device, a logic level high must be applied to the RST pin for at least two machine cycles (24 clocks), after the oscillator becomes stable. ALE, PSEN# are weakly pulled high during reset. During reset, ALE and PSEN# output a high level in order to perform a proper reset. This level must not be affected by external element. A system reset will not affect the 1 KByte of on-chip RAM while the device is running, however, the contents of the on-chip RAM during power up are indeterminate. Following reset, all Special Function Registers (SFR) return to their reset values outlined in Tables 3-5 to 3-9. + 10µF VDD RST 8.2K SST89E/V5xRDx C2 XTAL2 XTAL1 C1 1255 F30.1 FIGURE 10-1: Power-on Reset Circuit 10.1 Power-on Reset 10.2 Software Reset At initial power up, the port pins will be in a random state until the oscillator has started and the internal reset algorithm has weakly pulled all pins high. Powering up the device without a valid reset could cause the MCU to start executing instructions from an indeterminate location. Such undefined states may inadvertently corrupt the code in the flash. The software reset is executed by changing SFCF[1] (SWR) from “0” to “1”. A software reset will reset the program counter to address 0000H. All SFR registers will be set to their reset values, except SFCF[1] (SWR), WDTC[2] (WDTS), and RAM data will not be altered. 10.3 Brown-out Detection Reset When power is applied to the device, the RST pin must be held high long enough for the oscillator to start up (usually several milliseconds for a low frequency crystal), in addition to two machine cycles for a valid power-on reset. An example of a method to extend the RST signal is to implement a RC circuit by connecting the RST pin to VDD through a 10 µF capacitor and to VSS through an 8.2KΩ resistor as shown in Figure 10-1. Note that if an RC circuit is being used, provisions should be made to ensure the VDD rise time does not exceed 1 millisecond and the oscillator startup time does not exceed 10 milliseconds. The device includes a brown-out detection circuit to protect the system from severed supplied voltage VDD fluctuations. SST89E5xRD2/RD internal brown-out detection threshold is 3.85V, SST89V5xRD2/RD brown-out detection threshold is 2.35V. For brown-out voltage parameters, please refer to Tables 14-6 and 14-7. When VDD drops below this voltage threshold, the brownout detector triggers the circuit to generate a brown-out interrupt but the CPU still runs until the supplied voltage returns to the brown-out detection voltage VBOD. The default operation for a brown-out detection is to cause a processor reset. For a low frequency oscillator with slow start-up time the reset signal must be extended in order to account for the slow start-up time. This method maintains the necessary relationship between VDD and RST to avoid programming at an indeterminate location, which may cause corruption in the code of the flash. The power-on detection is designed to work as power up initially, before the voltage reaches the brown-out detection level. The POF flag in the PCON register is set to indicate an initial power up condition. The POF flag will remain active until cleared by software. Please see Section 3.6, “Power Control Register (PCON)” on page 31 for detailed information. VDD must stay below VBOD at least four oscillator clock periods before the brown-out detection circuit will respond. Brown-out interrupt can be enabled by setting the EBO bit in IEA register (address E8H, bit 3). If EBO bit is set and a brown-out condition occurs, a brown-out interrupt will be generated to execute the program at location 004BH. It is required that the EBO bit be cleared by software after the brown-out interrupt is serviced. Clearing EBO bit when the brown-out condition is active will properly reset the device. If brown-out interrupt is not enabled, a brown-out condition will reset the program to resume execution at location 0000H. For more information on system level design techniques, please review the FlashFlex MCU: Oscillator Circuit Design Considerations application note. ©2007 Silicon Storage Technology, Inc. S71255-08-000 59 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 11.0 INTERRUPTS 11.1 Interrupt Priority and Polling Sequence The device supports eight interrupt sources under a four level priority scheme. Table 11-1 summarizes the polling sequence of the supported interrupts. Note that the SPI serial interface and the UART share the same interrupt vector. (See Figure 11-1) TABLE 11-1: Interrupt Polling Sequence Interrupt Flag Vector Address Interrupt Enable Interrupt Priority Service Priority Wake-Up Power-down IE0 0003H EX0 PX0/H 1(highest) yes - 004BH EBO PBO/H 2 no T0 TF0 000BH ET0 PT0/H 3 no Ext. Int1 IE1 0013H EX1 PX1/H 4 yes T1 TF1 001BH ET1 PT1/H 5 no CF/CCFn 0033H EC PPCH 6 no Ext. Int. 2 IE2 003BH EX2 PX2/H 7 no Ext. Int. 3 IE3 0043H EX3 PX3/H 8 no UART/SPI TI/RI/SPIF 0023H ES PS/H 9 no T2 TF2, EXF2 002BH ET2 PT2/H 10 no Description Ext. Int0 Brown-out PCA T11-1.0 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 60 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet IE & IEA REGISTERS IP/IPH/IPA/IPAH REGISTERS HIGHEST PRIORITY INTERRUPT 0 INT0# IT0 IE0 1 INTERRUPT POLLING SEQUENCE BOF TF0 0 INT1# IT1 IE1 IT2 IE2 IT3 IE3 1 TF1 ECF CF CCFn ECCFn 0 INT2# 1 0 INT3# 1 RI TI SPIF SPIE TF2 EXF2 INDIVIDUAL ENABLES GLOBAL DISABLE LOWEST PRIORITY INTERRUPT 1255 F31.0 FIGURE 11-1: Interrupt Structure ©2007 Silicon Storage Technology, Inc. S71255-08-000 61 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 12.0 POWER-SAVING MODES 12.2 Power-down Mode The device provides two power saving modes of operation for applications where power consumption is critical. The two modes are idle and power-down, see Table 12-1. The power-down mode is entered by setting the PD bit in the PCON register. In the power-down mode, the clock is stopped and external interrupts are active for level sensitive interrupts only. SRAM contents are retained during powerdown, the minimum VDD level is 2.0V. 12.1 Idle Mode The device exits power-down mode through either an enabled external level sensitive interrupt or a hardware reset. The start of the interrupt clears the PD bit and exits power-down. Holding the external interrupt pin low restarts the oscillator, the signal must hold low at least 1024 clock cycles before bringing back high to complete the exit. Upon interrupt signal being restored to logic VIH, the first instruction of the interrupt service routine will execute. A hardware reset starts the device similar to power-on reset. Idle mode is entered setting the IDL bit in the PCON register. In idle mode, the program counter (PC) is stopped. The system clock continues to run and all interrupts and peripherals remain active. The on-chip RAM and the special function registers hold their data during this mode. The device exits idle mode through either a system interrupt or a hardware reset. Exiting idle mode via system interrupt, the start of the interrupt clears the IDL bit and exits idle mode. After exit the Interrupt Service Routine, the interrupted program resumes execution beginning at the instruction immediately following the instruction which invoked the idle mode. A hardware reset starts the device similar to a power-on reset. To exit properly out of power-down, the reset or external interrupt should not be executed before the VDD line is restored to its normal operating voltage. Be sure to hold VDD voltage long enough at its normal operating level for the oscillator to restart and stabilize (normally less than 10 ms). TABLE 12-1: Power Saving Modes Mode Initiated by State of MCU Exited by Idle Mode Software (Set IDL bit in PCON) MOV PCON, #01H; CLK is running. Interrupts, serial port and timers/counters are active. Program Counter is stopped. ALE and PSEN# signals at a HIGH level during Idle. All registers remain unchanged. Enabled interrupt or hardware reset. Start of interrupt clears IDL bit and exits idle mode, after the ISR RETI instruction, program resumes execution beginning at the instruction following the one that invoked idle mode. A user could consider placing two or three NOP instructions after the instruction that invokes idle mode to eliminate any problems. A hardware reset restarts the device similar to a power-on reset. Power-down Mode Software (Set PD bit in PCON) MOV PCON, #02H; CLK is stopped. On-chip SRAM and SFR data is maintained. ALE and PSEN# signals at a LOW level during power -down. External Interrupts are only active for level sensitive interrupts, if enabled. Enabled external level sensitive interrupt or hardware reset. Start of interrupt clears PD bit and exits powerdown mode, after the ISR RETI instruction program resumes execution beginning at the instruction following the one that invoked power-down mode. A user could consider placing two or three NOP instructions after the instruction that invokes power-down mode to eliminate any problems. A hardware reset restarts the device similar to a power-on reset. T12-1.0 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 62 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 13.0 SYSTEM CLOCK AND CLOCK OPTIONS 13.1 Clock Input Options and Recommended Capacitor Values for Oscillator TABLE 13-1:Recommended Values for C1 and C2 by Crystal Type Shown in Figure 13-1 are the input and output of an internal inverting amplifier (XTAL1, XTAL2), which can be configured for use as an on-chip oscillator. Crystal C1 = C2 Quartz 20-30pF Ceramic 40-50pF T13-1.0 1255 When driving the device from an external clock source, XTAL2 should be left disconnected and XTAL1 should be driven. More specific information about on-chip oscillator design can be found in the FlashFlex Oscillator Circuit Design Considerations application note. At start-up, the external oscillator may encounter a higher capacitive load at XTAL1 due to interaction between the amplifier and its feedback capacitance. However, the capacitance will not exceed 15 pF once the external signal meets the VIL and VIH specifications. 13.2 Clock Doubling Option By default, the device runs at 12 clocks per machine cycle (x1 mode). The device has a clock doubling option to speed up to 6 clocks per machine cycle. Please refer to Table 13-2 for detail. Crystal manufacturer, supply voltage, and other factors may cause circuit performance to differ from one application to another. C1 and C2 should be adjusted appropriately for each design. Table 13-1, shows the typical values for C1 and C2 vs. crystal type for various frequencies Clock double mode can be enabled either via the external host mode or the IAP mode. Please refer to Table 4-2 for the IAP mode enabling commands (When set, the EDC# bit in SFST register will indicate 6 clock mode.). The clock double mode is only for doubling the internal system clock and the internal flash memory, i.e. EA#=1. To access the external memory and the peripheral devices, careful consideration must be taken. Also note that the crystal output (XTAL2) will not be doubled. XTAL2 C2 NC External Oscillator Signal C1 XTAL1 XTAL2 XTAL1 VSS VSS External Clock Drive Using the On-Chip Oscillator FIGURE 13-1: Oscillator Characteristics 1255 F32.0 TABLE 13-2: Clock Doubling Features Device Standard Mode (x1) Clock Double Mode (x2) Clocks per Machine Cycle Max. External Clock Frequency (MHz) Clocks per Machine Cycle Max. External Clock Frequency (MHz) SST89E5xRD2/RD 12 40 6 20 SST89V5xRD2/RD 12 33 6 16 T13-2.0 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 63 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 14.0 ELECTRICAL SPECIFICATION Absolute Maximum Stress Ratings (Applied conditions greater than those listed under “Absolute Maximum Stress Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these conditions or conditions greater than those defined in the operational sections of this data sheet is not implied. Exposure to absolute maximum stress rating conditions may affect device reliability.) Ambient Temperature Under Bias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55°C to +125°C Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65°C to +150°C Voltage on EA# Pin to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +14.0V D.C. Voltage on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to VDD+0.5V Transient Voltage (<20ns) on Any Other Pin to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -1.0V to VDD+1.0V Maximum IOL per I/O Pins P1.5, P1.6, P1.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20mA Maximum IOL per I/O for All Other Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15mA Package Power Dissipation Capability (TA = 25°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5W Through Hole Lead Soldering Temperature (10 Seconds). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300°C Surface Mount Solder Reflow Temperature1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C for 10 seconds Output Short Circuit Current2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA 1. Excluding certain with-Pb 32-PLCC units, all packages are 260°C capable in both non-Pb and with-Pb solder versions. Certain with-Pb 32-PLCC package types are capable of 240°C for 10 seconds; please consult the factory for the latest information. 2. Outputs shorted for no more than one second. No more than one output shorted at a time. (Based on package heat transfer limitations, not device power consumption. Note: This specification contains preliminary information on new products in production. Specifications are subject to change without notice. TABLE 14-1: Operating Range Symbol Description TA Ambient Temperature Under Bias VDD fOSC Min. Max Unit Standard 0 +70 Industrial -40 +85 °C °C SST89E5xRD2/RD 4.5 5.5 V SST89V5xRD2/RD 2.7 3.6 V SST89E5xRD2/RD 0 40 MHz SST89V5xRD2/RD 0 33 MHz SST89E5xRD2/RD .25 40 MHz SST89V5xRD2/RD .25 33 MHz Supply Voltage Oscillator Frequency Oscillator Frequency for IAP T14-1.0 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 64 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 14-2: Reliability Characteristics Symbol NEND TDR ILTH 1 1 Parameter Minimum Specification Units Test Method Endurance 10,000 Cycles JEDEC Standard A117 100 Years JEDEC Standard A103 100 + IDD mA Data Retention 1 Latch Up JEDEC Standard 78 T14-2.0 1255 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. TABLE 14-3: AC Conditions of Test Input Rise/Fall Time . . . . . . . . . . . . . . . 10 ns Output Load . . . . . . . . . . . . . . . . . . . . . CL = 100 pF See Figures 14-8 and 14-10 T14-3.0 1255 TABLE 14-4: Recommended System Power-up Timings Symbol TPU-READ Parameter 1 TPU-WRITE1 Minimum Units Power-up to Read Operation 100 µs Power-up to Write Operation 100 µs T14-4.0 1255 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter TABLE 14-5: Pin Impedance (VDD=3.3V, TA=25 °C, f=1 Mhz, other pins open) Parameter Test Condition Maximum I/O Pin Capacitance VI/O = 0V 15 pF CIN1 Input Capacitance VIN = 0V 12 pF LPIN2 Pin Inductance CI/O 1 Description 20 nH T14-5.0 1255 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. 2. Refer to PCI spec. ©2007 Silicon Storage Technology, Inc. S71255-08-000 65 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 14.1 DC Electrical Characteristics TABLE 14-6: DC Electrical Characteristics for SST89E5xRD2/RD TA = -40°C to +85°C; VDD = 4.5-5.5V; VSS = 0V Symbol Parameter Test Conditions Min Max Units VIL Input Low Voltage 4.5 < VDD < 5.5 -0.5 0.2VDD - 0.1 V VIH Input High Voltage 4.5 < VDD < 5.5 0.2VDD + 0.9 VDD + 0.5 V VIH1 Input High Voltage (XTAL1, RST) 4.5 < VDD < 5.5 0.7VDD VDD + 0.5 V VOL Output Low Voltage (Ports 1.5, 1.6, 1.7) 1.0 V IOL = 100µA2 0.3 V IOL = 1.6mA2 0.45 V IOL = 3.5mA2 1.0 V IOL = 200µA2 0.3 V 3.2mA2 0.45 V VDD = 4.5V IOL = 16mA VOL VOL1 VDD = 4.5V Output Low Voltage (Ports 1, 2, 3)1 VDD = 4.5V Output Low Voltage (Port 0, ALE, PSEN#)1,3 IOL = VOH VOH1 VDD = 4.5V Output High Voltage (Ports 1, 2, 3, ALE, PSEN#)4 Output High Voltage (Port 0 in External Bus Mode)4 VBOD Brown-out Detection Voltage IIL Logical 0 Input Current (Ports 1, 2, 3) ITL Logical 1-to-0 Transition Current (Ports 1, 2, 3)5 ILI Input Leakage Current (Port 0) RRST RST Pull-down Resistor CIO Pin Capacitance6 IDD Power Supply Current IOH = -10µA VDD - 0.3 V IOH = -30µA VDD - 0.7 V IOH = -60µA VDD - 1.5 V IOH = -200µA VDD - 0.3 V IOH = -3.2mA VDD - 0.7 VDD = 4.5V 3.85 V 4.15 V VIN = 0.4V -75 µA VIN = 2V -650 µA 0.45 < VIN < VDD-0.3 ±10 µA 225 KΩ 15 pF 88 mA 50 mA 42 mA TA = 0°C to +70°C 80 µA TA = -40°C to +85°C 90 µA 40 @ 1 MHz, 25°C IAP Mode @ 40 MHz Active Mode @ 40 MHz Idle Mode @ 40 MHz Power-down Mode T14-6.2 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 66 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 1. Under steady state (non-transient) conditions, IOL must be externally limited as follows: Maximum IOL per port pin: 15mA Maximum IOL per 8-bit port:26mA Maximum IOL total for all outputs:71mA If IOL exceeds the test condition, VOL may exceed the related specification. Pins are not guaranteed to sink current greater than the listed test conditions. 2. Capacitive loading on Ports 0 and 2 may cause spurious noise to be superimposed on the VOLs of ALE and Ports 1 and 3. The noise due to external bus capacitance discharging into the Port 0 and 2 pins when the pins make 1-to-0 transitions during bus operations. In the worst cases (capacitive loading > 100pF), the noise pulse on the ALE pin may exceed 0.8V. In such cases, it may be desirable to qualify ALE with a Schmitt Trigger, or use an address latch with a Schmitt Trigger STROBE input. 3. Load capacitance for Port 0, ALE and PSEN#= 100pF, load capacitance for all other outputs = 80pF. 4. Capacitive loading on Ports 0 and 2 may cause the VOH on ALE and PSEN# to momentarily fall below the VDD - 0.7 specification when the address bits are stabilizing. 5. Pins of Ports 1, 2, and 3 source a transition current when they are being externally driven from 1 to 0. The transition current reaches its maximum value when VIN is approximately 2V. 6. Pin capacitance is characterized but not tested. EA# is 25pF (max). ©2007 Silicon Storage Technology, Inc. S71255-08-000 67 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 14-7: DC Electrical Characteristics for SST89V5xRD2/RD TA = -40°C to +85°C; VDD = 2.7-3.6V; VSS = 0V Symbol Parameter Test Conditions Min Max Units -0.5 0.7 V VIL Input Low Voltage 2.7 < VDD < 3.6 VIH Input High Voltage 2.7 < VDD < 3.6 0.2VDD + 0.9 VDD + 0.5 V VIH1 Input High Voltage (XTAL1, RST) 2.7 < VDD < 3.6 0.7VDD VDD + 0.5 V VOL Output Low Voltage (Ports 1.5, 1.6, 1.7) 1.0 V IOL = 100µA2 0.3 V IOL = 1.6mA2 0.45 V IOL = 3.5mA2 1.0 V IOL = 200µA2 0.3 V IOL = 3.2mA2 0.45 V VDD = 2.7V IOL = 16mA VOL VOL1 VOH VOH1 Output Low Voltage (Ports 1, 2, VDD = 2.7V 3)1 VDD = 2.7V Output Low Voltage (Port 0, ALE, PSEN#)1,3 VDD = 2.7V Output High Voltage (Ports 1, 2, 3, ALE, PSEN#)4 Output High Voltage (Port 0 in External Bus Mode)4 VBOD Brown-out Detection Voltage IIL Logical 0 Input Current (Ports 1, 2, 3) ITL Logical 1-to-0 Transition Current (Ports 1, 2, 3)5 ILI Input Leakage Current (Port 0) RRST RST Pull-down Resistor CIO Pin Capacitance6 IDD Power Supply Current IOH = -10µA VDD - 0.3 V IOH = -30µA VDD - 0.7 V IOH = -60µA VDD - 1.5 V IOH = -200µA VDD - 0.3 V IOH = -3.2mA VDD - 0.7 V VDD = 2.7V 2.35 2.55 V VIN = 0.4V -75 µA VIN = 2V -650 µA 0.45 < VIN < VDD-0.3 ±10 µA 225 KΩ 15 pF 47 mA 30 mA 21 mA TA = 0°C to +70°C 45 µA TA = -40°C to +85°C 55 µA @ 1 MHz, 25°C IAP Mode @ 33 MHz Active Mode @ 33 MHz Idle Mode @ 33 MHz Power-down Mode T14-7.1 1255 ©2007 Silicon Storage Technology, Inc. S71255-08-000 68 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 1. Under steady state (non-transient) conditions, IOL must be externally limited as follows: Maximum IOL per port pin: 15mA 26mA Maximum IOL per 8-bit port: Maximum IOL total for all outputs: 71mA If IOL exceeds the test condition, VOL may exceed the related specification. Pins are not guaranteed to sink current greater than the listed test conditions. 2. Capacitive loading on Ports 0 and 2 may cause spurious noise to be superimposed on the VOLs of ALE and Ports 1 and 3. The noise due to external bus capacitance discharging into the Port 0 and 2 pins when the pins make 1-to-0 transitions during bus operations. In the worst cases (capacitive loading > 100pF), the noise pulse on the ALE pin may exceed 0.8V. In such cases, it may be desirable to qualify ALE with a Schmitt Trigger, or use an address latch with a Schmitt Trigger STROBE input. 3. Load capacitance for Port 0, ALE and PSEN#= 100pF, load capacitance for all other outputs = 80pF. 4. Capacitive loading on Ports 0 and 2 may cause the VOH on ALE and PSEN# to momentarily fall below the VDD - 0.7 specification when the address bits are stabilizing. 5. Pins of Ports 1, 2, and 3 source a transition current when they are being externally driven from 1 to 0. The transition current reaches its maximum value when VIN is approximately 2V. 6. Pin capacitance is characterized but not tested. EA# is 25pF (max). ©2007 Silicon Storage Technology, Inc. S71255-08-000 69 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 30 Maximum Active IDD 25 Maximum Idle IDD IDD (mA) 20 15 Typical Active IDD 5 Typical Idle IDD 0 5 FIGURE 1255 F33.0 10 10 15 20 25 Internal Clock Frequency (MHz) 30 35 14-1: IDD vs. Frequency for 3V SST89V5xRD2/RD 50 Maximum Active IDD Maximum Idle IDD 30 20 1255 F34.0 IDD (mA) 40 Typical Active IDD 10 Typical Idle IDD 0 5 10 15 20 25 30 35 40 Internal Clock Frequency (MHz) FIGURE 14-2: IDD vs. Frequency for 5V SST89E5xRD2/RD ©2007 Silicon Storage Technology, Inc. S71255-08-000 70 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 14.2 AC Electrical Characteristics AC Characteristics: (Over Operating Conditions: Load Capacitance for Port 0, ALE#, and PSEN# = 100pF; Load Capacitance for All Other Outputs = 80pF) TABLE 14-8: AC Electrical Characteristics (1 of 2) TA = -40°C to +85°C, VDD = 2.7-3.6V@33MHz, 4.5-5.5V@40MHz, VSS = 0V Oscillator 33 MHz (x1 Mode) 16 MHz (x2 Mode)1 40 MHz (x1 Mode) 20 MHz (x2 Mode)1 Variable Symbol Parameter Min Max Min Max Min Max Units 1/TCLCL x1 Mode Oscillator Frequency 0 33 0 40 0 40 MHz 1/2TCLCL x2 Mode Oscillator Frequency 0 16 0 20 0 20 MHz TLHLL ALE Pulse Width 46 TAVLL Address Valid to ALE Low 5 Address Hold After ALE Low 5 35 10 TLLAX 10 TLLIV 2TCLCL - 15 ns TCLCL - 25 (3V) ns TCLCL - 15 (5V) ns TCLCL - 25 (3V) ns TCLCL - 15 (5V) ns 56 ALE Low to Valid Instr In 55 TLLPL ALE Low to PSEN# Low TPLPH PSEN# Pulse Width TPLIV PSEN# Low to Valid Instr In 5 TPXIZ TCLCL - 15 (5V) ns 3TCLCL - 25 (3V) 3TCLCL - 15 (5V) ns 60 35 Address to Valid Instr In 22 17 10 PSEN# Low to Address Float TRLRH RD# Pulse Width 142 TWLWH Write Pulse Width (WE#) 142 TRLDV RD# Low to Valid Data In TRHDZ Data Float After RD# ALE Low to Valid Data In Address to Valid Data In TCLCL - 15 (5V) ns ns ns 10 10 ns 6TCLCL - 40 (3V) 6TCLCL - 30 (5V) ns 120 6TCLCL - 40 (3V) 6TCLCL - 30 (5V) ns 120 0 5TCLCL - 90 (3V) ns 5TCLCL - 50 (5V) ns 0 36 152 183 150 ©2007 Silicon Storage Technology, Inc. ns ns 62 0 ns TCLCL - 5 (3V) 5TCLCL - 80 (3V) 150 TAVDV ns 5TCLCL - 60 (5V) 38 TLLDV 3TCLCL - 50 (5V) 65 75 Data Hold After RD# ns TCLCL - 8 72 TPLAZ TRHDX 3TCLCL - 55 (3V) 0 25 10 TAVIV ns 10 66 Input Instr Float After PSEN# PSEN# to Address valid 4TCLCL - 45 (5V) ns Input Instr Hold After PSEN# TPXAV ns TCLCL - 25 (3V) 25 TPXIX 4TCLCL - 65 (3V) ns 2TCLCL - 25 (3V) ns 2TCLCL - 12 (5V) ns 8TCLCL - 90 (3V) ns 8TCLCL - 50 (5V) ns 9TCLCL - 90 (3V) ns 9TCLCL - 75 (5V) ns S71255-08-000 71 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 14-8: AC Electrical Characteristics (Continued) (2 of 2) TA = -40°C to +85°C, VDD = 2.7-3.6V@33MHz, 4.5-5.5V@40MHz, VSS = 0V Oscillator 33 MHz (x1 Mode) 16 MHz (x2 Mode)1 Symbol Parameter Min Max TLLWL ALE Low to RD# or WR# Low 66 116 TAVWL Address to RD# or WR# Low 46 Data Hold After WR# 3 40 MHz (x1 Mode) 20 MHz (x2 Mode)1 Min 60 Max Min Max Units 3TCLCL + 25 (3V) 3TCLCL + 15 (5V) ns 90 3TCLCL - 25 (3V) 3TCLCL - 15 (5V) 70 TWHQX 5 Data Valid to WR# High 142 TQVWX Data Valid to WR# High to Low Transition 10 TRLAZ RD# Low to Address Float TWHLH RD# to WR# High to ALE High TQVWH 4TCLCL - 75 (3V) ns 4TCLCL - 30 (5V) ns TCLCL - 27 (3V) ns TCLCL - 20 (5V) ns 7TCLCL - 70 (3V) ns 125 7TCLCL - 50 (5V) ns 5 TCLCL - 20 ns 0 5 Variable 0 55 10 40 0 ns TCLCL - 25 (3V) TCLCL + 25 (3V) ns TCLCL - 15 (5V) TCLCL + 15 (5V) ns T14-8.0 1255 1. Calculated values are for x1 Mode only Explanation of Symbols Each timing symbol has 5 characters. The first character is always a ‘T’ (stands for time). The other characters, depending on their positions, stand for the name of a signal or the logical status of that signal. The following is a list of all the characters and what they stand for. A: C: D: H: I: L: P: Address Clock Input data Logic level HIGH Instruction (program memory contents) Logic level LOW or ALE PSEN# Q: R: T: V: W: X: Z: Output data RD# signal Time Valid WR# signal No longer a valid logic level High Impedance (Float) For example: TAVLL = Time from Address Valid to ALE Low TLLPL = Time from ALE Low to PSEN# Low ©2007 Silicon Storage Technology, Inc. S71255-08-000 72 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TLHLL ALE TAVLL TLLIV TLLPL TPLPH TPLIV PSEN# TPXAV TPLAZ TLLAX PORT 0 TPXIZ TPXIX A0 - A7 A0 - A7 INSTR IN TAVIV PORT 2 A8 - A15 A8 - A15 1255 F35.0 FIGURE 14-3: External Program Memory Read Cycle TLHLL ALE TWHLH PSEN# TLLDV TRLRH TLLWL RD# TLLAX TAVLL PORT 0 TRLDV TRLAZ TRHDZ TRHDX DATA IN A0-A7 FROM RI or DPL A0-A7 FROM PCL INSTR IN TAVWL TAVDV PORT 2 P2[7:0] or A8-A15 FROM DPH A8-A15 FROM PCH 1255 F36.0 FIGURE 14-4: External Data Memory Read Cycle ©2007 Silicon Storage Technology, Inc. S71255-08-000 73 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TLHLL ALE TWHLH PSEN# TWLWH TLLWL WR# TLLAX TAVLL TQVWX TWHQX TQVWH PORT 0 A0-A7 FROM RI or DPL DATA OUT A0-A7 FROM PCL INSTR IN TAVWL PORT 2 P2[7:0] or A8-A15 FROM DPH A8-A15 FROM PCH 1255 F37.0 FIGURE 14-5: External Data Memory Write Cycle TABLE 14-9: External Clock Drive Oscillator 40MHz Symbol Parameter 1/TCLCL Oscillator Frequency Min Variable Max Min 0 Max 40 Units MHz 25 TCLCL TCHCX High Time 8.75 TCLCX Low Time 8.75 ns TCLCH Rise Time 10 TCHCL Fall Time 10 0.35TCLCL 0.65TCLCL ns 0.35TCLCL 0.65TCLCL ns ns ns T14-9.0 1255 VDD - 0.5 0.45 V 0.7VDD TCHCX 0.2 VDD - 0.1 TCLCX TCLCL TCHCL FIGURE TCLCH 1255 F38.0 14-6: External Clock Drive Waveform ©2007 Silicon Storage Technology, Inc. S71255-08-000 74 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 14-10: Serial Port Timing Oscillator 12MHz 40MHz Parameter Min TXLXL Serial Port Clock Cycle Time 1.0 0.3 12TCLCL µs TQVXH Output Data Setup to Clock Rising Edge 700 117 10TCLCL - 133 ns TXHQX Output Data Hold After Clock Rising Edge 50 2TCLCL - 117 ns 0 2TCLCL - 50 ns 0 0 ns TXHDX Input Data Hold After Clock Rising Edge TXHDV Clock Rising Edge to Input Data Valid Max Min Variable Symbol 0 700 Max Min Max 117 Units 10TCLCL - 133 ns T14-10.0 1255 INSTRUCTION 0 1 2 3 4 5 6 7 8 ALE TXLXL CLOCK TXHQX TQVXH OUTPUT DATA WRITE TO SBUF INPUT DATA 0 1 2 TXHDV VALID 3 4 5 6 7 TXHDX VALID SET TI VALID VALID VALID VALID VALID VALID SET R I CLEAR RI 1255 F39.0 FIGURE VIHT VILT 14-7: Shift Register Mode Timing Waveforms VLOAD +0.1V VHT Timing Reference Points VLOAD VLT VLOAD -0.1V VOH -0.1V VOL +0.1V 1255 F41.0 1255 F40.0 For timing purposes, a port pin is no longer floating when a 100 mV change from load voltage occurs, and begins to float when a 100 mV change from the loaded VOH/VOL level occurs. IOL/IOH = ± 20mA. AC Inputs during testing are driven at VIHT (VDD -0.5V) for Logic "1" and VILT (0.45V) for a Logic "0". Measurement reference points for inputs and outputs are at VHT (0.2VDD + 0.9) and VLT (0.2VDD - 0.1) Note: VHT- VHIGH Test VLT- VLOW Test VIHT-VINPUT HIGH Test VILT- VINPUT LOW Test FIGURE 14-8: AC Testing Input/Output Test Waveform FIGURE ©2007 Silicon Storage Technology, Inc. 14-9: Float Waveform S71255-08-000 75 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TO TESTER TO DUT CL 1255 F42.0 FIGURE 14-10: A Test Load Example VDD VDD VDD IDD VDD VDD P0 VDD RST (NC) EA# RST EA# SST89x5xRDx XTAL2 XTAL1 VSS (NC) XTAL2 XTAL1 VSS 1255 F43.1 1255 F44.1 All other pins disconnected All other pins disconnected FIGURE 14-11: IDD Test Condition, Active Mode FIGURE 14-13: IDD Test Condition, Power-down Mode TABLE 14-11: Flash Memory Programming/ Verification Parameters1 VDD VDD IDD VDD P0 RST EA# SST89x5xRDx CLOCK SIGNAL (NC) VDD P0 SST89x5xRDx CLOCK SIGNAL IDD XTAL2 XTAL1 VSS Parameter2 Max Units Chip-Erase Time 150 ms Block-Erase Time 100 ms Sector-Erase Time 30 ms Byte-Program Time3 50 µs Re-map or Security bit Program Time 80 µs T14-11.0 1255 1. For IAP operations, the program execution overhead must be added to the above timing parameters. 2. Program and Erase times will scale inversely proportional to programming clock frequency. 3. Each byte must be erased before programming. 1255 F45.1 All other pins disconnected FIGURE 14-12: IDD Test Condition, Idle Mode ©2007 Silicon Storage Technology, Inc. S71255-08-000 76 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 15.0 PRODUCT ORDERING INFORMATION Device SST89x5xRDx - Speed XX Suffix1 - X Suffix2 - XX X Package Attribute E1 = non-Pb F2 = non-Pb, non-Sn Package Modifier I = 40 pins J = 44 pins Package Type P = PDIP N = PLCC Q = WQFN TQ = TQFP Operation Temperature C = Commercial = 0°C to +70°C I = Industrial = -40°C to +85°C Operating Frequency 33 = 0-33MHz 40 = 0-40MHz Feature Attribute 2 = Port 4 present Feature Set and Flash Memory Size 54RD = C52 feature set + 16(32) KByte 58RD = C52 feature set + 32(40) KByte Note: Number in parenthesis includes an additional 8 KByte flash which can be enabled. Voltage Range E = 4.5-5.5V V = 2.7-3.6V Product Series 89 = C51 Core 1. Environmental suffix “E” denotes non-Pb solder. SST non-Pb solder devices are “RoHS Compliant”. 2. Environmental suffix “F” denotes non-Pb/non-SN solder. SST non-Pb/non-Sn solder devices are “RoHS Compliant”. ©2007 Silicon Storage Technology, Inc. S71255-08-000 77 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 15.1 Valid Combinations Valid combinations for SST89E54RD2 SST89E54RD2-40-C-NJE SST89E54RD2-40-C-TQJE SST89E54RD2-40-I-NJE SST89E54RD2-40-I-TQJE Valid combinations for SST89V54RD2 SST89V54RD2-33-C-NJE SST89V54RD2-33-C-TQJE SST89V54RD2-33-I-NJE SST89V54RD2-33-I-TQJE Valid combinations for SST89E58RD2 SST89E58RD2-40-C-NJE SST89E58RD2-40-C-TQJE SST89E58RD2-40-I-NJE SST89E58RD2-40-I-TQJE Valid combinations for SST89V58RD2 SST89V58RD2-33-C-NJE SST89V58RD2-33-C-TQJE SST89V58RD2-33-I-NJE SST89V58RD2-33-I-TQJE Valid combinations for SST89E54RD SST89E54RD-40-C-PIE Valid combinations for SST89V54RD SST89V54RD-33-C-PIE SST89V54RD-33-C-QIF SST89V54RD-33-I-QIF Valid combinations for SST89E58RD SST89E58RD-40-C-PIE Valid combinations for SST89V58RD SST89V58RD-33-C-PIE Note: Valid combinations are those products in mass production or will be in mass production. Consult your SST sales representative to confirm availability of valid combinations and to determine availability of new combinations. ©2007 Silicon Storage Technology, Inc. S71255-08-000 78 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet 16.0 PACKAGING DIAGRAMS 40 CL .600 .625 1 Pin #1 Identifier .530 .557 2.020 2.070 .065 .075 12˚ 4 places .220 Max. Base Plane Seating Plane .015 Min. .063 .090 Note: FIGURE .045 .055 .015 .022 .100 BSC .100 † .200 .600 BSC 1. Complies with JEDEC publication 95 MS-011 AC dimensions (except as noted), although some dimensions may be more stringent. † = JEDEC min is .115; SST min is less stringent 2. All linear dimensions are in inches (min/max). 40-pdip-PI-7 3. Dimensions do not include mold flash. Maximum allowable mold flash is .010 inches. 16-1: 40-pin Plastic Dual In-line Pins (PDIP) SST Package Code: PI TOP VIEW .685 .695 .646 † .656 Optional Pin #1 Identifier .042 .048 1 44 SIDE VIEW .020 R. MAX. .042 x45˚ .056 BOTTOM VIEW .147 .158 .025 R. .045 .013 .021 .042 .048 .685 .695 0˚ 15˚ .008 .012 .646 † .656 .500 REF. .026 .032 .590 .630 .050 BSC. .100 .112 .050 BSC. .165 .180 Note: FIGURE .020 Min. .026 .032 44-plcc-NJ-7 1. Complies with JEDEC publication 95 MS-018 AC dimensions (except as noted), although some dimensions may be more stringent. † = JEDEC min is .650; SST min is less stringent 2. All linear dimensions are in inches (min/max). 3. Dimensions do not include mold flash. Maximum allowable mold flash is .008 inches. 4. Coplanarity: 4 mils. 16-2: 44-lead Plastic Lead Chip Carrier (PLCC) SST Package Code: NJ ©2007 Silicon Storage Technology, Inc. S71255-08-000 79 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet Pin #1 Identifier 44 34 1 33 .30 .45 10.00 ± 0.10 .80 BSC 12.00 ± 0.25 11 23 12 10.00 ± 0.10 .09 .20 22 12.00 ± 0.25 .95 1.05 1.2 max. Note: .05 .15 1. Complies with JEDEC publication 95 MS-026 ACB dimensions, although some dimensions may be more stringent. 2. All linear dimensions are in millimeters (min/max). 3. Coplanarity: 0.1 (±0.05) mm. 4. Package body dimensions do not include mold flash. Maximum allowable mold flash is .25mm. FIGURE 0˚- 7˚ .45 .75 1.00 ref 44-tqfp-TQJ-7 1mm 16-3: 44-lead Thin Quad Flat Pack (TQFP) SST Package Code: TQJ TOP VIEW SIDE VIEW BOTTOM VIEW See notes 2 and 3 0.2 Pin #1 Pin #1 0.5 BSC 6.00 ± 0.10 4.1 0.075 0.05 Max 6.00 ± 0.10 4.1 0.30 0.18 0.45 0.35 0.80 0.70 Note: 1. Complies with JEDEC JEP95 MO-220I, variant WJJD-5 except external paddle nominal dimensions. 1mm 2. From the bottom view, the pin #1 indicator may be either a 45-degree chamfer or a half-circle notch. 3. The external paddle is electrically connected to the die back-side and possibly to certain VSS leads. 40-wqfn-6x6-QI-1 This paddle should be soldered to the PC board; it is suggested to connect this paddle to the VSS of the unit. Connection of this paddle to any other voltage potential will result in shorts and/or electrical malfunction of the device. 4. Untoleranced dimensions are nominal target dimensions. 5. All linear dimensions are in millimeters (max/min). FIGURE 16-4: 40-contact Very-very-thin Quad Flat No-lead (WQFN) SST Package Code: QI ©2007 Silicon Storage Technology, Inc. S71255-08-000 80 1/07 FlashFlex MCU SST89E54RD2/RD / SST89E58RD2/RD SST89V54RD2/RD / SST89V58RD2/RD Data Sheet TABLE 16-1: Revision History Number Description Date 00 • 01 • • • • Changed MPNs of SST89E/V5xRD2 PDIP devices to SST89E/V5xRD Removed SST89E/V516RD2 devices and associated MPNs Removed all industrial temperature PDIP devices and associated MPNs Clarified Surface Mount Temperatures in “Absolute Maximum Stress Ratings” on page 64 • Changes in Tables 14-6 and 14-7: – Removed the minimum VDD=2V for IDD Power-down (also Figure 14-13) – Removed the 12 MHz values for IDD Sep 2004 02 • • • • Mar 2005 • Corrected MPN breakdown definition for “2” to read “Port 4 present” Corrected the SPI control Register definition for CPHA on page 30 Added SST89E/V5xRD industrial temperature PDIP devices and associated MPNs Added RoHS compliance information on page 1 and in the “Product Ordering Information” on page 77 Corrected the solder temperature profile under “Absolute Maximum Stress Ratings” on page 64 Removed references to External Host Mode programming 03 • Made changes to add WQFN package Mar 2006 04 • Revised Figure 3-1 on page 11. Changed 7HHH to 1HHH. Apr 2006 05 • • Revised Figure 3-1 on page 11. Changed 8000H to 2000H. Changed document status from Preliminary Specification to Data Sheet. May 2006 06 • • Removed NJ, TQJ, and PI packages from Valid Combinations on page 77. Removed valid combinations SST89E52RD-40-I-PIE, SST89E54RD-40-I-PIE, SST89E58RD-40-I-PIE, SST89V52RD-33-I-PIE, SST89V54RD-33-I-PIE, and SST89V58RD-33-I-PIE on page 77. Oct 2006 07 • Nov 2006 • Removed SST89E52RD2/RD and SST89V52RD2/RD. Created EOL data sheet for these products, see S71255(03) Removed 12MHz columns from Table 14-9. • Changed FlashFlex51 to FlashFlex globally Jan 2007 • 08 Initial Release Mar 2004 Silicon Storage Technology, Inc. • 1171 Sonora Court • Sunnyvale, CA 94086 • Telephone 408-735-9110 • Fax 408-735-9036 www.SuperFlash.com or www.sst.com ©2007 Silicon Storage Technology, Inc. S71255-08-000 81 1/07