MICREL SY10E116JI

QUINT DIFFERENTIAL
LINE RECEIVER
FEATURES
SY10E116
SY100E116
DESCRIPTION
■ 450ps max. Propagation Delay
■ Extended 100E VEE range of –4.2V to –5.5V
The SY10/100E116 are quint differential line receivers
designed for use in new, high-performance ECL systems.
These devices have emitter-follower outputs and an
internally generated reference supply (VBB) for singleended reception.
Active current sources combined with Micrel-Synergy’s
ASSET™ technology provide the receivers with excellent
common mode noise rejection.
The receiver design features clamp circuitry to cause a
defined output state if both the inverting and non-inverting
inputs are left open; in this case the Q output goes LOW,
while the Q output goes HIGH.
If both inverting and non-inverting inputs are at equal
potential, the receiver does not go to a defined state, but
rather shares current in normal differential amplifier fashion,
producing output voltage levels midway between HIGH
and LOW.
The VBB output is intended for use as a reference
voltage for single-ended reception of ECL signals to that
device only. When using VBB for this purpose, it is
recommended that VBB is decoupled to VCC via a 0.01 µF
capacitor.
For higher bandwidth, please refer to the SY10/100E416
device.
■ VBB output for single-ended reception
■ Fully compatible with industry standard 10KH,
100K I/O levels
■ Internal 75KΩ input pulldown resistors
■ Fully compatible with Motorola MC10E/100E116
■ Available in 28-pin PLCC package
BLOCK DIAGRAM
D3
Q3
D3
Q3
D4
Q4
D4
Q4
PIN CONFIGURATION
VBB
VCCO
Q2
Q4
D2
Q4
Q2
25
24 23 22 21 20 19
D3
26
18
Q3
D2
27
17
Q3
D2
VEE
VBB
28
16
VCC
15
14
Q2
Q2
D0
3
13
VCCO
4
12
Q1
D0
PLCC
TOP VIEW
J28-1
1
2
10 11
5
6
7
8
9
Q0
VCCO
D2
VCCO
Q1
D4
D1
Q0
Q1
VCCO
D1
D3
Q0
D4
D0
D1
Q0
D1
D0
Pin
Function
D0, D0-D4, D4
Differential Input Pairs
Q0, Q0-Q4, Q4
Differential Output Pairs
VBB
Reference Voltage Output
VCCO
VCC to Output
Q1
PIN NAMES
Rev.: E
1
Amendment: /0
Issue Date: November, 1998
SY10E116
SY100E116
Micrel
LOGIC EQUATION
Qn = Dn
DC ELECTRICAL CHARACTERISTICS
VEE = VEE(Min.) to VEE(Max.); VCC = VCCO = GND
TA = –40°C
Symbol
Parameter
Output Reference
Voltage
10E
100E
VBB
IIH
Input HIGH Current
IEE
Power Supply Current
10E
100E
VPP (DC)
Input Sensitivity(1)
(2)
Common Mode Range
VCMR
TA = 0°C
TA = +25°C
TA = +85°C
Min. Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
–1.43
–1.43
—
—
–1.30
–1.26
–1.38
–1.38
—
—
–1.27
–1.26
–1.35
–1.38
—
—
–1.25
–1.26
–1.31
–1.38
—
—
–1.19
–1.26
—
—
200
—
—
200
—
—
200
—
—
200
Unit
V
µA
mA
—
—
29
29
35
35
—
—
29
29
35
35
—
—
29
29
35
35
—
—
29
33
35
40
150
—
—
150
—
—
150
—
—
150
—
—
mV
–2.0
—
–0.6
–2.0
—
–0.6
–2.0
—
–0.6
–2.0
—
–0.6
V
NOTES:
1. VPP is the minimum differential input voltage required to assure full ECL levels are present at the outputs.
2. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the "HIGH" input is within the VCMR range
and the input swing is greater than VPP (min.) and <1V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE(Min.) to VEE(Max.); VCC = VCCO = GND
TA = –40°C
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
tPLH
tPHL
Propagation Delay to
Output
D
D (S.E.)
150
150
300
300
500
550
200
150
300
300
450
500
200
150
300
300
450
500
200
150
300
300
450
500
VPP (DC)
Input Sensitivity(1)
150
—
150
150
—
—
150
—
—
150
—
—
mV
—
50
—
—
50
—
—
50
—
—
50
—
ps
—
±10
—
—
±10
—
—
±10
—
—
±10
—
ps
250
375
625
275
375
575
275
375
575
275
375
575
ps
tskew
Within-Device Skew
Dn to Qn, Qn
tskew
Duty Cycle Skew(3)
(2)
ps
tPLH – tPHL
tr
tf
Rise/Fall Time
20% to 80%
NOTES:
1. Minimum input swing for which AC parameters are guaranteed.
2. Within-device skew is defined as identical transitions on similar paths through a device.
3. Duty cycle skew is defined only for differential operation when the delays are measured from the cross point of the inputs to the cross point of the
outputs.
PRODUCT ORDERING CODE
Ordering
Code
Package
Type
Operating
Range
SY10E116JC
J28-1
Commercial
SY10E116JCTR
J28-1
SY100E116JC
J28-1
SY100E116JCTR
J28-1
Ordering
Code
Package
Type
Operating
Range
SY10E116JI
J28-1
Industrial
Commercial
SY10E116JITR
J28-1
Industrial
Commercial
SY100E116JI
J28-1
Industrial
Commercial
SY100E116JITR
J28-1
Industrial
2
SY10E116
SY100E116
Micrel
28 LEAD PLCC (J28-1)
Rev. 03
3
SY10E116
SY100E116
Micrel
MICREL-SYNERGY
TEL
3250 SCOTT BOULEVARD SANTA CLARA CA 95054 USA
+ 1 (408) 980-9191
FAX
+ 1 (408) 914-7878
WEB
http://www.micrel.com
This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or
other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc.
© 2000 Micrel Incorporated
4