MICREL SY10E150JCTR

SY10E150
SY100E150
SY10E150
6-BIT D
LATCH
Micrel, Inc.
DESCRIPTION
FEATURES
■ 700ps max. propagation delay
■ Extended 100E VEE range of –4.2V to –5.5V
The SY10/100E150 are 6-bit D latches with differential
outputs designed for use in new, high- performance ECL
systems. When both Latch Enables (LEN1, LEN2) are at a
logic LOW, the latch is in the transparent mode and input
data propagates through to the output. A logic HIGH on
either LEN1 or LEN2 (or both) latches the input data. The
Master Reset (MR) overrides all other signals to set the Q
outputs to a logic LOW.
■ Differential outputs
■ Fully compatible with industry standard 10KH,
100K ECL levels
■ Internal 75KΩ input pulldown resistors
■ Fully compatible with Motorola MC10E/100E150
■ Available in 28-pin PLCC package
BLOCK DIAGRAM
D0
PIN NAMES
D
R
D1
D
R
D2
D
R
D3
D
R
D5
Pin
Q0
Q0
Q1
Q1
Q2
Function
D0–D5
Data Inputs
LEN1, LEN2
Latch Enables
MR
Master Reset
Q0–Q5
True Outputs
Q0–Q5
Inverting Outputs
VCCO
VCC to Output
Q2
Q3
D
R
D4
SY100E150
D
R
Q3
Q4
Q4
Q5
Q5
LEN1
LEN2
MR
M9999-032006
[email protected] or (408) 955-1690
Rev.: F
1
Amendment: /0
Issue Date: March 2006
SY10E150
SY100E150
Micrel, Inc.
Ordering Information(1)
VCCO
Q5
Q5
LEN1
NC
MR
LEN2
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
D5
26
18
Q4
D4
D3
VEE
D2
27
17
Q4
VCC
Q3
D1
D0
3
28
16
PLCC
TOP VIEW
J28-1
1
2
15
14
13
12
4
9
10 11
VCCO
8
Q0
Q1
Q1
7
Q0
6
NC
VCCO
5
Q3
Q2
Q2
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY10E150JC
J28-1
Commercial
SY10E150JC
Sn-Pb
SY10E150JCTR(2)
J28-1
Commercial
SY10E150JC
Sn-Pb
SY100E150JC
J28-1
Commercial
SY100E150JC
Sn-Pb
SY100E150JCTR(2)
J28-1
Commercial
SY100E150JC
Sn-Pb
SY10E150JZ(3)
J28-1
Commercial
SY10E150JZ with
Matte-Sn
Pb-Free bar-line indicator
SY10E150JZTR(2, 3)
J28-1
Commercial
SY10E150JZ with
Matte-Sn
Pb-Free bar-line indicator
SY100E150JZ(3)
J28-1
Commercial
SY100E150JZ with
Matte-Sn
Pb-Free bar-line indicator
SY100E150JZTR(2, 3)
J28-1
Commercial
SY100E150JZ with
Matte-Sn
Pb-Free bar-line indicator
28-Pin PLCC (J28-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
[email protected] or (408) 955-1690
2
SY10E150
SY100E150
Micrel, Inc.
TRUTH TABLE(1)
(Each Latch)
INPUTS
OUTPUTS
Operating
Dn
LEN1
LEN2
MR
Qn
Qn
Mode
H
L
L
L
H
L
Latch
L
L
L
L
L
H
Latched(2)
X
X
H
L
Latched(2)
X
H
X
L
Latched(2)
Latched(2)
X
X
X
H
L
H
Asynchronous
Notes:
1. H = HIGH state
L = LOW state
X = Don’t care
2. Retains Data that is present before the LEN positive transition.
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
IIH
IEE
Parameter
TA = +25°C
Min. Typ. Max. Min. Typ.
Input HIGH Current
D
LEN MR
TA = +85°C
Max. Min. Typ.
Max.
—
—
—
—
200
150
—
—
—
—
200
150
—
—
—
—
200
150
—
—
52
52
62
62
—
—
52
52
62
62
—
—
52
60
62
72
Power Supply Current
10E
100E
Unit
Condition
µA
—
mA
—
Unit
Condition
ps
—
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
TA = +25°C
TA = +85°C
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
Max.
Propagation Delay to Output
D
LEN
MR
250
375
450
375
500
625
550
700
750
250
375
450
375
500
625
550
700
750
250
375
450
375
500
625
550
700
750
tS
Set-up Time, D
200
50
—
200
50
—
200
50
—
ps
—
tH
Hold Time, D
200
–50
—
200
–50
—
200
–50
—
ps
—
tRR
Reset Recovery Time
750
650
—
750
650
—
750
650
—
ps
—
tPW
Minimum Pulse Width, MR
400
—
—
400
—
—
400
—
—
ps
—
tskew
Within-Device Skew
—
50
—
—
50
—
—
50
—
ps
1
tr
tf
Rise/Fall Time
20% to 80%
300
450
650
300
450
650
300
450
650
ps
—
tPD
Parameter
Note:
1. Within-device skew is defined as identical transitions on similar paths through a device.
M9999-032006
[email protected] or (408) 955-1690
3
SY10E150
SY100E150
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032006
[email protected] or (408) 955-1690
4