MICREL SY10E195JC

Micrel, Inc.
PROGRAMMABLE
DELAY CHIP
FEATURES
SY10E195
SY100E195
DESCRIPTION
■ Up to 2ns delay range
■ Extended 100E VEE range of –4.2V to –5.5V
■
■
■
■
■
■
Precison Edge®
SY10E195
Precison SY100E195
Edge®
The SY10/100E195 are programmable delay chips
(PDCs) designed primarily for clock de-skewing and timing
adjustment. They provide variable delay of a differential
ECL input transition.
The delay section consists of a chain of gates
organized as shown in the logic diagram. The first two
delay elements feature gates that have been modified to
have delays 1.25 and 1.5 times the basic gate delay of
approximately 80ps. These two elements provide the
E195 with a digitally-selectable resolution of
approximately 20ps. The required device delay is selected
by the seven address inputs D[0:6], which are latched
on-chip by a high signal on the latch enable (LEN) control.
If the LEN signal is either LOW or left floating, then the
latch is transparent.
Because the delay programmability of the E195 is
achieved by purely differential ECL gate delays, the
device will operate at frequencies of >1GHz, while
maintaining over 600mV of output swing.
The E195 thus offers very fine resolution, at very high
frequencies, selectable entirely from a digital input,
allowing for very accurate system clock timing.
An eighth latched input, D7, is provided for cascading
multiple PDCs for increased programmable range. The
cascade logic allows full control of multiple PDCs, at the
expense of only a single added line to the data bus for
each additional PDC, without the need for any external
gating.
≈20ps/digital step resolution
>1GHz bandwidth
On-chip cascade circuitry
75KkΩ input pulldown resistor
Fully compatible with Motorola MC10E/100E195
Available in 28-pin PLCC package
PIN NAMES
Pin
M9999-032006
[email protected] or (408) 955-1690
Function
IN/IN
Signal Input
EN
Input Enable
D[0:7]
Mux Select Inputs
Q/Q
Signal Output
LEN
Latch Enable
SET MIN
Minimum Delay Set
SET MAX
Maximum Delay Set
CASCADE
Cascade Signal
Rev.: H
1
Amendment: /0
Issue Date: March 2006
Precison Edge®
SY10E195
SY100E195
Micrel, Inc.
Ordering Information(1)
D7
NC
D5
D6
D2
D3
D4
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY10E195JC
Sn-Pb
D1
26
18
NC
SY10E195JC
J28-1
Commercial
D0
LEN
27
17
NC
VCC
SY10E195JCTR(2)
J28-1
Commercial
SY10E195JC
Sn-Pb
SY100E195JI
J28-1
Industrial
SY100E195JI
Sn-Pb
28
16
TOP VIEW
PLCC
J28-1
VEE
IN
2
14
Q
SY100E195JITR(2)
J28-1
Industrial
SY100E195JI
Sn-Pb
IN
3
13
VBB
4
12
Q
VCCO
SY10E195JZ(3)
J28-1
Commercial
SY10E195JZ with
Pb-Free bar-line indicator
Matte-Sn
SY10E195JZTR(2, 3)
J28-1
Commercial
SY10E195JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E195JY(3)
J28-1
Industrial
SY100E195JY with
Pb-Free bar-line indicator
Matte-Sn
SY100E195JYTR(2, 3)
J28-1
Industrial
SY100E195JY with
Pb-Free bar-line indicator
Matte-Sn
7
8
9
VCCO
10 11
CASCADE
6
NC
NC
5
15
EN
SET MIN
SET MAX
CASCADE
1
28-Pin PLCC (J28-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
[email protected] or (408) 955-1690
2
Precison Edge®
SY10E195
SY100E195
Micrel, Inc.
BLOCK DIAGRAM
1
0
1
1
*1.5
0
1
1
D1
0
1
1
D2
1
0
1
7-Bit Latch
D3
4 gates
D4
0
1
D5
8 gates
D6
0
1
Q
LEN
Latch
D
D7
16 gates
0
1
Q
Q
3
0
1
1
Cascade
CASCADE
CASCADE
M9999-032006
[email protected] or (408) 955-1690
VBB
IN
IN
EN
*1.25
LEN
SET MIN
SET MAX
D0
*Delays are 25% or 50% longer than
standard (standard = 80ps).
Precison Edge®
SY10E195
SY100E195
Micrel, Inc.
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = GND
TA = 0°C
Symbol
Parameter
IIH
Input HIGH Current
IEE
Power Supply Current
10E
100E
M9999-032006
[email protected] or (408) 955-1690
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Condition
—
—
150
—
—
150
—
—
150
µA
—
mA
—
—
—
130
130
156
156
—
—
130
130
156
156
—
—
130
150
156
179
4
Precison Edge®
SY10E195
SY100E195
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = GND
TA = 0°C
Symbol
tPD
TA = +25°C
TA = +85°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max. Unit
Propagation Delay to Output
IN to Q; Tap = 0
IN to Q; Tap = 127
EN to Q; Tap = 0
D7 to CASCADE
1210
3320
1250
300
1360
3570
1450
450
1510
3820
1650
700
1240
3380
1275
300
1390
3630
1475
450
1540
3880
1675
700
1440
3920
1350
300
1590
4270
1650
450
1765
4720
1950
700
2000
2175
—
2050
2240
—
2375
2580
—
—
—
55
115
250
505
1000
17
34
68
136
272
544
1088
—
—
105
180
325
620
1190
—
—
55
115
250
515
1030
17.5
35
70
140
280
560
1120
—
—
105
180
325
620
1220
—
—
65
140
305
620
1240
21
42
84
168
336
672
1344
—
—
120
205
380
740
1450
tRANGE
Programmable Range
tPD (max.) – tPD (min.)
∆t
Step Delay
D0 High
D1 High
D2 High
D3 High
D4 High
D5 High
D6 High
Condition
ps
—
ps
—
ps
6
Lin
Linearity
D1
D0
—
D1
D0
—
D1
D0
—
—
7
tskew
Duty Cycle Skew, tPHL–tPLH
—
±30
—
—
±30
—
—
±30
—
ps
1
tS
Set-up Time
D to LEN
D to IN
EN to IN
200
800
200
0
—
—
—
—
—
200
800
200
0
—
—
—
—
—
200
800
200
0
—
—
—
—
—
Hold Time
LEN to D
IN to EN
500
0
250
—
—
—
500
0
250
—
—
—
500
0
250
—
—
—
Release Time
EN to IN
SET MAX to LEN
SET MIN to LEN
300
800
800
—
—
—
—
—
—
300
800
800
—
—
—
—
—
—
300
800
800
—
—
—
—
—
—
—
<5
—
—
<5
—
—
<5
—
125
300
225
450
325
650
125
300
225
450
325
650
125
300
225
450
325
650
tH
tR
tjit
Jitter
tr
tf
Rise/Fall Times
20–80% (Q)
20–80% (CASCADE)
ps
2
3
ps
4
ps
5
ps
8
ps
—
Notes:
2. Duty cycle skew guaranteed only for differential operation measured from the cross point of the input to the cross point of the output.
3. This set-up time defines the amount of time prior to the input signal the delay tap of the device must be set.
4. This set-up time is the minimum time that EN must be asserted prior to the next transition of IN/IN to prevent an output response greater than ±75mV to
that IN/IN transition.
5. This hold time is the minimum time that EN must remain asserted after a negative going IN or positive going IN to prevent an output response greater than
±75mV to that IN/IN transition.
6. This release time is the minimum time that EN must be deasserted prior to the next IN/IN transition to ensure an output response that meets the specified
IN to Q propagation delay and transition times.
7. Specification limits represent the amount of delay added with the assertion of each individual delay control pin. The various combinations of asserted delay
control inputs will typically realize D0 resolution steps across the specified programmable range.
8. The linearity specification guarantees to which delay control input the programmable steps will be monotonic (i.e. increasing delay steps for increasing
binary counts on the control inputs Dn). Typically, the device will be monotonic to the D0 input, however, under worst case conditions and process variation,
delays could decrease slightly with increasing binary counts when the D0 input is the LSB. With the D1 input as the LSB, the device is guaranteed to be
monotonic over all specified environmental conditions and process variation.
9. The jitter of the device is less than what can be measured without resorting to very tedious and specialized measurement techniques.
M9999-032006
[email protected] or (408) 955-1690
5
Precison Edge®
SY10E195
SY100E195
Micrel, Inc.
APPLICATIONS INFORMATION
ADDRESS BUS (A0 – A6)
D1
D0
D0
VEE
E196
Chip #1
VCC
LEN
VCCO
VEE
D7
D6
D4
D5
D3
D2
D6
D7
D5
D1
LEN
VCC
E196
Chip #2
VCCO
Q
VCCO
VBB
EN
EN
VBB
CASCADE
IN
SET MAX
Q
CASCADE
IN
SET MIN
Q
CASCADE
IN
SET MAX
Q
CASCADE
IN
SET MIN
Input
D4
D3
D2
A7
Output
VCCO
Figure 1. Cascading Interconnect Architecture
Cascading Multiple E195s
To increase the programmable range of the E195,
internal cascade circuitry has been included. This circuitry
allows for the cascading of multiple E195s without the
need for any external gating. Furthermore, this capability
requires only one more address line per added E195.
Obviously, cascading multiple PDCs will result in a larger
programmable range; however, this increase is at the
expense of a longer minimum delay.
Figure 1 illustrates the interconnect scheme for
cascading two E195s. As can be seen, this scheme can
easily be expanded for larger E195 chains. The D7 input
of the E195 is the cascade control pin. With the
interconnect scheme of Figure 1, when D7 is asserted, it
signals the need for a larger programmable range than
is achievable with a single device.
An expansion of the latch section of the block diagram
is pictured below. Use of this diagram will simplify the
explanation of how the cascade circuitry works. When
D7 of chip #1 above is low, the cascade output will also
be low, while the cascade bar output will be a logical
high. In this condition, the SET MIN pin of chip #2 will
be asserted and, thus, all of the latches of chip #2 will
be reset and the device will be set at its minimum delay.
Since the RESET and SET inputs of the latches are
overriding, any changes on the A0–A6 address bus will
not affect the operation of chip #2.
M9999-032006
[email protected] or (408) 955-1690
Chip #1, on the other hand, will have both SET MIN
and SET MAX de-asserted so that its delay will be
controlled entirely by the address bus A0–A6. If the delay
needed is greater than can be achieved with 31.75 gate
delays (1111111 on the A0–A6 address bus), D7 will be
asserted to signal the need to cascade the delay to the
next E195 device. When D7 is asserted, the SET MIN
pin of chip #2 will be de-asserted and the delay will be
controlled by the A0–A6 address bus. Chip #1, on the
other hand, will have its SET MAX pin asserted, resulting
in the device delay to be independent of the A 0–A 6
address bus.
When the SET MAX pin of chip #1 is asserted, the D0
and D1 latches will be reset while the rest of the latches
will be set. In addition, to maintain monotonicity, an
additional gate delay is selected in the cascade circuitry.
As a result, when D7 of chip #1 is asserted, the delay
increases from 31.75 gates to 32 gates. A 32-gate delay
is the maximum delay setting for the E195.
To expand this cascading scheme to more devices,
one simply needs to connect the D7 input and CASCADE
outputs of the current most significant E195 to the new
most significant E195 in the same manner as pictured in
Figure 1. The only addition to the logic is the increase
of one line to the address bus for cascade control of the
second PDC.
6
Precison Edge®
SY10E195
SY100E195
Micrel, Inc.
SET MIN
SET MAX
Bit 0
D1
Q1
Reset
Bit 1
LEN
Q0
Reset
D0
Reset Reset
D2
Set
LEN
Bit 2
Q2
Reset
D3
Set
LEN
Set
LEN
D4
To Select Multiplexers
Bit 3
Q3
Reset
Bit 4
Q4
Reset
D5
Set
LEN
Bit 5
Q5
Reset
D6
Set
LEN
Bit 6
Q6
Reset
D7
LEN
Bit 7
Q7
CASCADE
CASCADE
7
M9999-032006
[email protected] or (408) 955-1690
LEN
Figure 2. Expansion of the
Latch Section of the E195
Block Diagram
Precison Edge®
SY10E195
SY100E195
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032006
[email protected] or (408) 955-1690