MICREL SY88952LMITR

Micrel, Inc.
3.3V, 2.7Gbps SDH/SONET
LASER DRIVER WITH AUTOMATIC
POWER CONTROL
FEATURES
■
■
■
■
■
■
■
■
■
■
DESCRIPTION
Single 3.3V power supply
Up to 2.7Gbps operation
Rise/Fall times: < 75ps
Independent programmable laser modulation and
bias currents
Bias current to 100mA and modulation current to
90mA
Automatic average laser power control
Bias and modulation current monitors
Operating temperature range of –40°C to +85°C
Complies with ANSI, ITU, and Bellcore SDH/SONET
specifications
Available in DIE form and 32-pin (5mm × 5mm)
EPAD-MLF™ package
SY88952L is a highly integrated and programmable
laser driver for SONET/SDH application up to 2.7Gbps.
The device accepts differential PECL or LVDS data and
clock inputs. It provides programmable bias and
modulation currents for driving a laser. The modulation
output of SY88952L can be DC-coupled to drive the laser
diode, providing a significant power saving over ACcoupled operation. A synchronizing TTL input latch can
be used to reduce jitter if a clock signal is available. A
TTL enable is also incorporated in the device. EN only
enables/disables IMOD. It does not enable/disable IBIAS.
An automatic power controller (APC) is integrated into
SY88952L to maintain a constant average optical output
power over temperature and lifetime. The modulation
current can be externally temperature compensated to
minimize the variation of extinction ratio of the optical
output.
Several safety features will enable an alarm function
when the output signal is too high, or bias current is too
high.
There are two alarm conditions:
1. /FAIL asserts when bias current loop goes to
maximum of it's range. IBIAS and IMOD still flow under
this condition.
2. /FAIL asserts when IBIASMAX or IMODSET are too
high (implying IBIAS or IMOD will be too high). All currents
will shut off under this condition.
APPLICATIONS
■
■
■
■
■
■
SY88952L
SY88952L
OC-48 transceivers and transponders
SONET/SDH transmission system
Add drop mux
Metro area network
2.5Gbps optical transmitter
Fiber optical module
MLF and MicroLeadFrame are trademarks of Amkor Technology, Inc.
M9999-082205
[email protected] or (408) 955-1690
Rev.: B
1
Amendment: /0
Issue Date: August 2005
SY88952L
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
VCC
BIASMAX
MODSET
VEE
VEE
VEE
SLOW
MD
Ordering Information(1)
32 31 30 29 28 27 26 25
VCC
D
/D
VCC
CLK
/CLK
VCC
LATCH
1
24
2
23
3
22
4
21
5
20
6
19
7
18
8
17
9 10 11 12 13 14 15 16
VCC
/Q
/Q
VCC
Q
Q
VCC
VEE
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY88952LMI
MLF-32
Industrial
SY88952L
Sn-Pb
SY88952LMITR(2)
MLF-32
Industrial
SY88952L
Sn-Pb
SY88952LMG
MLF-32
Industrial
SY88952L with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY88952LMGTR(2)
MLF-32
Industrial
SY88952L with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
EN
VEE
BIASMON
MODMON
/FAIL
VEE
VEE
BIAS
Notes:
1.
Dice are designed to operate from –40°C to +85°C, but are tested and guaranteed to TA = +25°C
only.
2.
Tape and Reel.
32-Pin MLF™ (MLF-32)
PIN DESCRIPTION
Pin Number
Pin Name
16
BIAS
Pin Function
11
BIASMON
Bias Current Monitor: Sinks current that is proportional to IBIAS, (IBIAS /40). An external current
path must exist to VCC.
31
BIASMAX
A resistor (RBIASMAX) connected to ground sets the maximum bias current.
See “Typical Operating Characteristics” (IBIAS vs. RBIASMAX).
26
SLOW
5, 6
CLK,/CLK
2, 3
D, /D
9
EN
8
LATCH
25
MD
Bias Current Output (IBIAS).
Connect a capacitor (CSLOW) to ground to provide a slow-start.
Differential Clock Input. 75KΩ pull-down on CLK, 75kΩ pull-up and 75kΩ pull-down on /CLK.
Differential Data Input. 75KΩ pull-down on D, 75kΩ pull-up and 75kΩ pull-down on /D.
TTL Input with 75kΩ pull-up: Default HIGH for normal operation; LOW to disable modulation
current.
TTL Input with 75kΩ pull-up: Default HIGH for latched (clocked) data; LOW for direct data.
Connect this pin to a monitor photodiode anode, a resistor (RAPCSET) and a capacitor (CAPCSET).
This sets the desired average optical power.
19, 20, 22, 23
Q, /Q
12
MODMON
Differential Output: Modulation current output (IMOD).
Modulation Current Monitor: Sinks current that is proportional to IMOD, (IMOD /45). An external
current path must exist to VCC.
30
MODSET
A resistor (RMODSET) connected to ground sets the modulation current.
See “Typical Operating Characteristics” (IMOD vs. RMODSET).
13
/FAIL
TTL Open-Collector Output: Connect a 5kΩ resistor to VCC. Indicates APC failure when LOW.
1, 4, 7, 18, 21, 24, 32
VCC
Positive Power Supply.
10, 14, 15, 17,
27, 28, 29, EP
VEE
Device Ground: Ensure the exposed pad is also connected to ground.
TRUTH TABLE(1)
D
/D
EN
OUT(2)
/OUT
L
H
H
H
L
H
L
H
L
H
X
X
L
H
L
M9999-082205
[email protected] or (408) 955-1690
Note 1.
Note 2.
2
L = LOW, H = HIGH, X = don't care.
H = IOUT ≤ IMOD_OFF.
Micrel, Inc.
SY88952L
Absolute Maximum Ratings(1)
Operating Ratings(2, 3)
Supply Voltage (VCC) ..................................... +0V to +7.0V
Input Voltage (VIN) ............................................ +0V to VCC
Output Current (IOUT) ............................................... 100mA
Lead Temperature (soldering, 10 sec.) ..................... 300°C
Storage Temperature (TS) ....................... –65°C to +150°C
Supply Voltage (VCC) .................................. +3.0V to +3.6V
Ambient Temperature (TA) ......................... –40°C to +85°C
Junction Temperature (TJ) ........................................ 120°C
Package Thermal Resistance
MLF™
(θJA) still-air ..................................................... 34°C/W
(ψJB) still-air ..................................................... 19°C/W
DC ELECTRICAL CHARACTERISTICS
VCC = 3.0V to 3.6V; VEE = GND; RLOAD = 5Ω; TA = –40°C to +85°C
Symbol
Parameter
Condition
ICC
Supply Current
Note 4
IBIAS
Bias Current Range
Note 5
IMOD
Modulation Current Range
Note 5
IMOD_OFF
Modulation Off Current
Note 6
VID
Differential Input Voltage
VICMR
Common Mode Range
VIH
TTL Input HIGH Voltage
VIL
TTL Input LOW Voltage
VOL
/FAIL Output LOW Voltage
IOH
/FAIL Output Leakage Current
Min
Typ
Max
Units
85
mA
1
100
mA
1
90
mA
750
µA
200
1600
mVPP
VCC –1.49
VCC –VID/4
V
2.0
VCC
V
0.8
V
Note 6
0.5
V
Note 7
100
µA
Notes:
1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is
not implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum ratlng
conditions for extended periods may affect device reliability.
2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
3.
4.
5.
6.
7.
8.
Devices are ESD sensitive. Handling precautions recommended.
Excluding actual IBIAS and IMOD output currents.
Voltage at Q, /Q must not drop below VCC –1.5V. Voltage BIAS, MODMON and BIASMON must not drop below VCC –2V.
EN = LOW.
IOL = +2mA.
VOH = 3.6V.
M9999-082205
[email protected] or (408) 955-1690
3
SY88952L
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS(9)
VCC = 3.0V to 3.6V; VEE = GND; TA = –40°C to +85°C; typical values @VCC = 3.3V, TA = 25°C, IMOD = 40mA, IBIAS = 50mA, RLOAD = 5Ω
Symbol
Parameter
Condition
Min
CID
Maximum Consecutive
Identical Digits
PWD
Pulse Width Distortion
tS
Latch Set-Up Time
40
ps
tH
Latch Hold Time
40
ps
tr, tf
Output Rise/Fall Time
(20% to 80%)
Max
80
Note 10, 11
75
9. AC characteristics are guaranteed by design and characterization.
10. Measured with 622Mbps 0-1 pattern, latch = HIGH.
11. PWD = (Wider pulse – narrower pulse) /2.
TIMING DIAGRAM
tCLK = 400ps
CLK
tS
tH
D
Setup/Hold Time Definition
4
Units
bits
50
Notes:
M9999-082205
[email protected] or (408) 955-1690
Typ
ps
ps
Micrel, Inc.
SY88952L
TYPICAL OPERATING CHARACTERISTICS(NOTE 1)
VCC = 3.3V, TA = 25°C, unless otherwise stated.
160
140
140
120
120
100
100
80
60
60
40
20
20
10000
0
10
100
1000
RBIASMAX (Ω)
Bias-Current Monitor Gain
vs. Temperature
IMOD = 40mA,
IBIAS = 50mA
50
40
30 IMOD = 10mA,
IBIAS = 10mA
20
10
0
-40
10000
-20 0
20 40 60
TEMPERATURE (°C)
IAPCSET vs. RAPCSET
2
IMOD = 40mA,
IBIAS = 50mA
50
1.5
40
IAPCSET (mA)
GAIN (IBIAS/IBIASMON)
60
30 IMOD = 10mA,
IBIAS = 10mA
20
1
0.5
10
0
-40
Note 1.
80
40
100
1000
RMODSET (Ω)
60
GAIN (IMOD/IMODMON)
160
0
10
Modulation-Current Monitor Gain
vs. Temperature
IBIAS vs. RBIASMAX
IBIAS (mA)
IMOD (mA)
IMOD vs. RMODSET
-20 0
20 40 60
TEMPERATURE (°C)
0
1
80
IBIAS and IMOD must never exceed 100mA and 90mA, respectively.
M9999-082205
[email protected] or (408) 955-1690
5
10
RAPCSET (KΩ)
100
80
SY88952L
Micrel, Inc.
BLOCK DIAGRAM
VCC
LATCH
/Q
0
RD
Q
D
D
MUX
Q
CLK
1
EN
VCC
100Ω
BIAS
BIASMON
X40
IBIAS
40
X40
VCC
MD
100Ω
MODMON
IMOD
45
RAPCSET
Failure
Detect
MODSET
RBIAS MAX
CSLOW
SLOW
RMODSET
VREF
/FAIL
BIASMAX
5kΩ
VCC
M9999-082205
[email protected] or (408) 955-1690
6
CAPCSET
Micrel, Inc.
SY88952L
32 LEAD EPAD-Micro LEADFRAME™ (MLF-32)
Package
EP- Exposed Pad
Die
CompSide Island
Heat Dissipation
Heat Dissipation
VEE
Heavy Copper Plane
VEE
Heavy Copper Plane
PCB Thermal Consideration for 32-Pin MLF™ Package
(Always solder to equivalent or PCB)
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2005 Micrel, Incorporated.
M9999-082205
[email protected] or (408) 955-1690