RHOMBUS-IND T-927

MULTI -PURPOSE TRANSFORMER
Turns Ratio ( + 2% )
PARAMETER
Open Circuit Inductance
1:1
MIN.
5.0
NOM.
UNITS
6.0
mHy
Leakage Inductance
110
µHy
Interwinding Capacitance (CW/W)
60
pF
Primary DC Resistance
10.4
ohms
Secondary DC Resistance
11.8
ohms
Isolation (HI-POT)
1.5
ET Product
175
Temperature Characteristics:
-55o C 4.35 mH nom. (13% drop in
inductance)
+125o C 4.75 mH nom. (5% drop in
inductance)
Typical part:
6.0 mH @ +25o C
5.7 mH @ +125o C
5.22 mH @ -40o C
KVRMS
500
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
VµS
TEST CONDITIONS:
Oscillation Voltage = 1 VRMS
Oscillation Frequency = 100.0 KHz
Inductance measured on Primary winding. Pins 1 - 2.
Parts shipped in anti-static
tubes. 26 pieces per tube
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
UNUSED PINS OMITTED
SCHEMATIC DIAGRAM:
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-927
CUST P/N:
DATE: 6/23/97
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com