ITT TFCFJ6VWP04AW

C&K TF Series
Miniature Snap-acting Switches
Features/Benefits
• Broad range of operating forces
• Ratings up to 25 AMPS
• Wide variety of actuator styles
• Quick connect terminations
Typical Applications
• Motor controls
• Thermostatics
• Portable tools
Specifications
Materials
CONTACT RATING: From low level* to 25 AMPS @ 277 V AC.
ELECTRICAL LIFE: 300,000 cycles at 10 AMPS @ 250 V AC,
consult Customer Service Center for typical life of higher
rated switches.
INSULATION RESISTANCE: 1,000 M ohm min.
DIELECTRIC STRENGTH: 1,500 Vrms min. @ sea level.
OPERATING TEMPERATURE: –40ºF to 185ºF (–40ºC to 85ºC).
OPERATING FORCE: From 15 to 400 grams at actuator
button available.
MOUNTING: Torque screws 2-5 in/lbs.
SWITCH HOUSING: Thermoplastic (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic (UL 94V-0).
SPRING: Copper alloy.
PIVOT: Brass alloy.
MOVABLE CONTACTS: Gold alloy for ratings 1 AMP or less.
Fine silver for ratings greater than 1 AMP up to 15 AMPS.
Precious metal alloy for ratings greater than 15 AMPS.
STATIONARY CONTACTS: Gold alloy for ratings 1 AMP or less.
Fine silver for ratings greater than 1 AMP.
TERMINALS: Brass alloy for ratings up to 10 AMPS.
Copper alloy for ratings greater than 10 AMPS.
* Low Level=conditions where no arcing occurs during switching, i.e., 0.4 VA max. @
20 V AC or DC max. Standard electrical life per UL 1054, rated for 6,000 operations.
K
NOTE: For the latest information regarding RoHS compliance, please go to:
www.ittcannon.com/rohs.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages K-6 through K-10. For additional options not shown in catalog, consult Customer Service Center.
T
F
Series
TF SP, Mom.
Operating Force
CJ 5.29 oz./150 grams
CC .53 oz./15 grams
CD .88 oz./25 grams
CF 1.76 oz./50 grams
CG 2.65 oz./75 grams
EC 7.94 oz./225 grams
EE 14.11 oz./400 grams
Electrical Rating
J6 15 A, 277 V AC; 1/2 HP, 125, 250 V AC;
5 A, 125 V AC “L”, 0.5 A, 125 V DC;
0.25 A, 250 V DC
F5 1 A,125 V AC; 1 A, 3O V DC
H8 5 A, 277 V AC; 1/10 HP, 125, 250 V AC
J3 21 A, 277 V AC; 1 HP, 125 V AC; 2 HP,
250 V AC; 5 A, 125 V AC “L”
K6 11 A, 277 V AC; 1/3 HP, 125, 250 V AC;
0.5 A, 125 V DC; 0.25 A, 250 V DC
L1 25 A, 277 V AC; 1.5 HP, 125 V AC; 2 HP,
250 V AC; 5 A, 125 V AC “L”
L3 20 A, 250 V AC; 1 HP, 125 V AC;
2 HP 250 V AC
V1 1 A,125 V AC; 1 A, 3O V DC (UL/CSA)
V2 5 A, 277 V AC; 1/10 HP, 125, 250 V AC (UL/CSA);
5(2) A, 250 V AC (VDE)
V3 11 A, 277 V AC; 1/3 HP, 125, 250 V AC;
0.5 A, 125 V DC; 0.25 A, 250 V DC (UL/CSA);
10(3) A, 25O V AC (VDE)
V4 21 A, 277 V AC; 1 HP, 125 V AC; 2 HP, 25O V AC;
5 A, 125 V AC “L”; 16(3) A, 25O V AC (VDE)
Mounting Style
S Standard
V Metric
Circuitry
C SPDT
W SPST N.C.
Y SPST N.O.
Actuator
P00 Pin plunger
A10 .81" lever roller, high force
A15 1.34" lever roller, high force
A20 1.05” lever roller, low force
A25 1.56" lever roller, low force
T10 .84" lever, high force
T13 1.34" simulated roller, high force
T14 1.29" simulated roller, high force
T15 1.40" lever, high force
T16 2.34" lever, high force
T18 2.75" lever, high force
T20 1.10" lever, low force
T23 1.56" simulated roller, low force
T24 1.50” simulated roller, low force
T25 1.62" lever, low force
T26 2.57" lever, low force
T28 2.97” lever, low force
WP0 Wide pin plunger
Terminations
40 .187" quick connect
4A .250" quick connect
5A .250" offset quick connect
5B .187" offset quick connect
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–5
www.ittcannon.com
Snap-acting
NOTE: Specifications and materials listed above are switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
C&K TF Series
Miniature Snap-acting Switches
SERIES
TF
MINIATURE SNAP-ACTING SWITCHES – SP MOMENTARY
OPERATING FORCE
BASIC SWITCH OPERATING
FORCE (OZ./GRAMS)
OPTION CODE
Snap-acting
K
CC
.53
15
CD
.88
25
CF
1.76
50
CG
2.65
75
CJ
5.29
150
EC
7.94
225
EE*
14.11
400
*Minimums may apply, consult Customer Service Center.
Operating Force option ‘CC’ not available with ‘T18 & T26’ Actuator options.
Operating force varies with actuator option, see ACTUATOR option section.
ELECTRICAL RATING
CONTACT MATERIAL
OPTION CODE
RoHS
COMPLIANT *
RoHS
COMPATIBLE *
MOVABLE
CONTACT
STATIONARY
CONTACT
F5
Yes
Yes
Gold alloy
Gold alloy
H8
Yes
Yes
J3
Yes
Yes
ELECTRICAL RATING
From low level* to 1 AMP @ 125 V AC, 1 AMP @ 30 V DC.
5 AMPS @ 277 V AC; 1/10 HP @ 125 & 250 V AC.
Fine Silver
Fine Silver
21 AMPS @ 277 V AC; 1 HP @ 125 V AC; 2 HP @ 250 V AC;
5 AMPS @ 125 V AC “L”.
J6
Yes
Yes
15 AMPS @ 277 V AC; 1/2 HP @ 125 & 250 V AC; 5 AMPS @ 125 V AC “L”. 0.5
AMP @ 125 V DC; 0.25 AMP @ 250 V DC.
K6
Yes
Yes
11 AMPS @ 277 V AC; 1/3 HP @ 125 & 250 V AC; 0.5 AMP @ 125 V DC;
0.25 AMP @ 250 V DC.
L1
Yes
Yes
L3
Yes
Yes
25 AMPS @ 125 & 277 V AC; 1 1/2 HP @ 125 V AC; 2 HP @ 250 V AC
Precious
metal alloy
20 AMPS @ 250 V AC; 1 HP @ 125 V AC; 2 HP @ 250 V AC
* Note: See Technical Data section of this catalog for RoHS compliant and compatible definitions and specifications.
All models
with all options,
* Low Level=conditions where no arcing
occurs during switching, i.e.,
0.4 VA max. @ 20 V AC or DC max.
.
Consult Customer Service center for availability and delivery of nonstandard ratings.
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–6
www.ittcannon.com
C&K TF Series
Miniature Snap-acting Switches
ELECTRICAL RATING
CONTACT MATERIAL
OPTION CODE
RoHS
COMPLIANT
RoHS
COMPATIBLE
V1
Yes
Yes
V2
Yes
Yes
V3
Yes
Yes
V4
Yes
Yes
MOVABLE
CONTACT
Gold alloy
STATIONARY
CONTACT
INTERNATIONAL ELECTRICAL RATING
From low level* to 1 AMP @ 125 V AC; 1 AMP @ 30 V DC (UL/CSA).
0.1 (0.05) AMP @ 250 V~m T85 50E3 (VDE).
Gold alloy
5 AMPS @ 277 V AC; 1/10 HP @ 125 & 250 V AC (UL/CSA).
5 (2) AMPS @ 250 V~m T85 50E3 (VDE).
Fine Silver
11 AMPS @ 277 V AC; 1/3 HP @ 125 & 250 V AC; 0.5 AMP @ 125 V DC;
0.25 AMP @ 250 V DC (UL/CSA). 10 (3) AMPS @ 250 V~m 50E3 T85 (VDE).
Fine Silver
Precious
metal alloy
21 AMPS @ 277 V AC; 1 HP @ 125 V AC; 2 HP @ 250 V AC;
16 (3) AMPS @ 250 V~m T85 10E3 (VDE).
* Note: See Technical Data section of this catalog for RoHS compliant and compatible definitions and specifications.
NOTE: V1-V4 ratings available with ‘5A or 5B’terminal styles only.
OPERATING FORCE
INTERNATIONAL RATING SYMBOLS
m
Microgap construction
(less than 3 mm).
~
Alternating current.
Maximum rated use temperature.
50E3
Cycles over 50,000 at rated current.
10E3
Cycles over 10,000 at rated current.
10(3)
First number represents resistive
rating; second number represents
inductive (motor) rating.
All models
with all options,
AMPS
(REF.)
CC
(15)
CD
(25)
CF
(50)
CG
(75)
CJ
(150)
F5
1
•
•
•
•
•
•
•
H8
5
•
•
•
•
•
•
•
J3
21
X
X
X
X
•
•
•
J6
15
X
X
X
X
•
•
•
K6
11
X
•
•
•
•
•
•
L1
25
X
X
X
X
X
•
X
L3
20
X
X
X
X
•
•
X
V1
1
•
•
•
•
•
X
X
V2
5
X
X
•
•
•
•
•
V3
11
X
X
X
•
•
•
•
V4
16
X
X
X
X
•
•
•
.
Consult Customer Service center for availability and delivery of
nonstandard ratings.
* Low Level=conditions where no arcing occurs during switching, i.e.,
0.4 VA max. @ 20 V AC or DC max.
EC
EE
(225) (400)
• AVAILABLE
x NOT AVAILABLE
** Available with 4A & 5A terminations only, see page K-10.
MOUNTING STYLE
S
V
STANDARD
For 4-40 screw size
Metric
For 3 mm screw size
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–7
www.ittcannon.com
K
Snap-acting
T_ _
ELECTRICAL
RATING
C&K TF Series
Miniature Snap-acting Switches
ACTUATOR
OPTION CODE
FIG.
DIM. A
DIM. B
DIM. C
1
.80
(20,3)
—
.578 ± .015
(14,68 ± 0,38)
—
A10
2
.81
(20,6)
.32
(8,1)
.810 ± .020
(20,57 ± 0,51)
.19 dia.
(4,8Ø)
A15
2
1.34
(34,0)
.32
(8,1)
.810 ± .030
(20,57 ± 0,76)
.19 dia.
(4,8Ø)
A20
2
1.05
(26,7)
.54
(13,7)
.810 ± .050
(20,57) ± 1,27
.19 dia.
(4,8Ø)
A25
2
1.56
(39,6)
.54
(13,7)
.810 ± .075
(20,57 ± 1,91)
.19 dia.
(4,8Ø)
T10
3
.84
(21,3)
.32
(8,1)
.600 ± .020
(15,24 ± 0,51)
—
T15
3
1.40
(35,6)
.32
(8,1)
.600 ± .040
(15,24 ± 1,02)
—
T16
3
2.34
(59,4)
.32
(8,1)
.600 ± .065
(15,24 ± 1,65)
—
T18
3
2.75
(69,9)
.32
(8,1)
.600 ± .080
(15,24 ± 2,03)
—
T20
3
1.10
(27,9)
.54
(13,7)
.600 ± .050
(15,24 ± 1,27)
—
T25
3
1.62
(41,1)
.54
(13,7)
.600 ± .070
(15,24 ± 1,78)
—
T26
3
2.57
(65,3)
.54
(13,7)
.600 ± .150
(15,24 ± 3,81)
—
T28
3
2.97
(75,4)
.54
(13,7)
.600 ± .187
(15,24 ) ± 4,75
—
T13
4
1.34
(34,0)
.32
(8,1)
.810 ± .030
(20,57 ± 0,76)
.19 dia.
(4,8Ø)
T14
4
1.29
(32,8)
.32
(8,1)
.730 ± .030
(18,54 ± 0,76)
.19 dia.
(6,4Ø)
T23
4
.19 dia.
(4,8Ø)
4
.54
(13,7)
.54
(13,9)
.810 ± .065
(20,57 ± 1,65)
T24
1.56
(39,6)
1.50
(38,1)
.25 dia.
(6,4Ø)
WP0
5
.80
(20,3)
—
.730 ± .060
(18,54) ± 1,52
.635 ± .015
(16,13 ± 0,38)
P00
Snap-acting
K
DIM. D
—
NOTE: Switch characteristics chart on following page.
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–8
www.ittcannon.com
C&K TF Series
Miniature Snap-acting Switches
ACTUATOR
SWITCH CHARACTERISTICS
MAXIMUM OPERATING FORCE
(OZ./GRAMS)
OPTION
CODE
MINIMUM RELEASE FORCE
(OZ./GRAMS)
MAXIMUM
DIFFERENTIAL
TRAVEL
MAXIMUM
PRETRAVEL
MINIMUM
OVERTRAVEL
CD
(25)
CF
(50)
CG
(75)
CJ
EC
EE
(150) (225) (400)
CC
(15)
CD
(25)
CF
(50)
CG
(75)
ALL FORCES
ALL FORCES
ALL FORCES
A10
.63
18
1.06
30
2.29
65
3.17
90
6.35
180
7.94 14.11
225 400
.21
6
.35
10
.35
10
.53
15
.71
20
1.98
56
3.88
110
.015
(0,38)
.060
(1,52)
.030
(0,76)
A15
.28
8
.42
12
1.06
30
1.59
45
3
85
4.59
130
7.94
225
.07
2
.14
4
.14
4
.18
5
.35
10
.71
20
2.82
80
.030
(0,76)
.100
(2,54)
.065
(1,65)
A20
0.53
15
0.71 1.41
20
40
2.12
60
4.23
120
6
170
9.7
275
0.07
2
0.11 0.11
3
3
0.18
5
0.42
12
0.71
20
1.41
40
0.025
(0,64)
0.12
(3,05)
0.055
(1,40)
A25
.18
5
.28
8
56
16
85
24
1.69
48
2.65
75
4.41
125
.04
1
.07
2
.07
2
.07
2
.21
6
.35
10
.71
20
.050
(1,27)
.250
(6,35)
.120
(3,05)
P00
.53
15
.88
25
1.76
50
2.65
75
5.29
150
7.94 14.11
225 400
.21
6
.35
10
.35
10
.53
15
1.23
35
1.98
56
3.88
110
.010
(0,25)
.047
(1,19)
.050
(1,27)
T10
.63
18
1.06
30
2.29
65
3.17
90
6.35
180
7.94 14.11
225 400
.21
6
.35
10
.35
10
.53
15
.71
20
1.98
56
3.88
110
.015
(0,38)
.060
(1,52)
.030
(0,76)
T13
.28
8
.42
12
1.06
30
1.59
45
3
85
4.59
130
7.94
225
.07
2
.14
4
.14
4
.18
5
.35
10
.71
20
2.82
80
.030
(0,76)
.100
(2,54)
.065
(1,65)
T14
.28
8
.42
12
1.23
35
1.76
50
3.17
90
4.76
135
7.94
225
.07
2
.14
4
.14
4
.18
5
.35
10
.71
20
2.82
80
.030
(0,76)
.100
(2,54)
.060
(1,52)
T15
.25
7
.42
12
1.06
30
1.41
40
2.82
80
4.41
125
7.94
225
.07
2
.14
4
.14
4
.18
5
.28
8
.63
18
2.82
80
.030
(0,76)
.110
(2,59)
.065
(1,65)
T16
.18
5
.28
8
.53
15
.78
22
1.59
45
2.47
70
4.23
120
.04
1
.07
2
.07
2
.07
2
.28
8
.35
10
.71
20
.045
(1,14)
.250
(6,35)
.125
(3,18)
T18
N/A
.21
6
.42
12
.71
20
1.41
40
2.12
60
3.53
100
N/A
.04
1
.04
1
.07
2
.18
5
.28
8
.56
16
.062
(1,57)
.300
(7,62)
.155
(3,94)
T20
.53
15
.71
20
1.41
40
2.12
60
4.23
120
6
170
9.70
275
.21
6
.35
10
.35
10
.53
15
.71
20
1.98
56
3.88
110
.030
(0,76)
.140
(3,56)
.060
(1,52)
T23
.18
5
.28
8
.56
16
.85
24
1.69
48
2.65
75
4.41
125
.04
1
.07
2
.07
2
.07
2
.21
6
.35
10
.71
20
.050
(1,27)
.250
(6,35)
.120
(3,05)
T24
0.18
5
0.28 0.56
8
16
0.88
25
1.76
50
2.65
75
4.76
135
0.04
1
0.07 0.07
2
2
0.11
3
0.21
6
0.35
10
0.71
20
.005
(1,27)
0.23
(5,84)
0.11
(2.79)
T25
.18
5
.28
8
.53
15
.88
25
1.59
45
2.47
70
4.23
120
.04
1
.07
2
.07
2
.07
2
.21
6
.35
10
.99
28
.055
(1,40)
.250
(6,35)
.125
(3,18)
T26
N/A
.14
4
.28
8
.04
1
N/A
N/A
N/A
.12
3.5
0.11
3
.21
6
0.18
5
.39
11
0.32
9
.500
(12,70)
N/A
.05
1.5
0.04
1
.100
(2,54)
N/A
2.26
64
1.94
55
.04
1
N/A
.85 1.27
24
36
0.71 1.06
20
30
N/A
T28
.42
12
0.42
12
0.12
(3,05)
.0.56
(14.22)
.235
(5,97)
0.285
(7,24)
WP0
.53
15
.88
25
1.76
50
2.65
75
5.29
150
.21
6
.35
10
.35
10
.53
15
1.23
35
1.97
56
3.88
110
.010
(0.25)
.047
(1,19)
.030
(0,51)
7.94 14.11
225 400
CJ
EC
EE
(150) (225) (400)
NOTE: For basic switch operating forces, see page K-6.
HIGH FORCE, LOW MOTION PIVOT POSITION
LOW FORCE, HIGH MOTION PIVOT POSITION
Available with actuators A10, A15, T10, T13, T14, T15, T16 and T18.
Available with actuators A20, A25, T20, T23, T24, T25, T26, and T28.
NOTE: Lever actuator options are available in either of two pivot positions.
Levers located in the forward pivot position have lower forces and higher motions.
Levers located in the rear pivot position have higher forces and lower motions.
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–9
www.ittcannon.com
K
Snap-acting
CC
(15)
C&K TF Series
Miniature Snap-acting Switches
TERMINATIONS
40
.187" QUICK CONNECT
5A
OFFSET .250" QUICK CONNECT
4A
5B
.250" QUICK CONNECT
OFFSET .187" QUICK CONNECT
Snap-acting
K
CIRCUITRY
C
W
Y
SPDT (Single Pole, Double Throw)
SPST N.C. (Single Pole, Single Throw, Normally Closed)
SPST N.O. (Single Pole, Single Throw, Normally Open)
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–10
www.ittcannon.com