TLP165J TOSHIBA Photocoupler GaAs Ired & Photo−Triac TLP165J Triac Drive Programmable Controllers AC−Output Module Solid State Relay Unit in mm The TOSHIBA mini flat coupler TLP165J is a small outline coupler, suitable for surface mount assembly. The TLP165J consists of a photo triac, optically coupled to a gallium arsenide infrared emitting diode. · Peak off−state voltage: 600 V (min.) · Trigger LED current: 10 mA (max.) · On−state current: 70 mA (max.) · Isolation voltage: 2500 Vrms (min.) · UL recognized: UL1577, file no. E67349 · Option(V4)type TOSHIBA VDE approved: VDE 0884 satisfied 11−4C3 Weight: 0.09 g Maximum operating insulation voltage: 565Vpk Highest permissible over voltage: 4000Vpk Trigger LED Current Type (Note 1) Pin Configurations Trigger LED Current (mA) VT=6V, Ta=25°C Min. Max. Marking Of Classification (IFT7) ― 7 T7 None ― 10 T7, blank * Exp. rank IFT7: TLP165J (IFT7) (Note 1) Application type name for certification test, please use standard product type name, i.e. TLP165J(IFT7): TLP165J 1 1 6 3 4 1 . Anode 3 . Cathode 4 . Terminal 1 6 . Terminal 2 2002-09-25 TLP165J Maximum Ratings (Ta = 25°C) Characteristic Symbol Rating Unit IF 50 mA ∆IF / °C -0.7 mA / °C Peak forward current (100µs pulse, 100 pps) IFP 1 A Reverse voltage VR 5 V Junction temperature Tj 125 °C VDRM 600 V Forward current LED Forward current derating (Ta ≥ 53°C) Off- state output terminal voltage Detector On-state RMS current Ta=25°C 70 IT(RMS) Ta=70°C mA 40 ∆IT / °C -0.67 mA / °C ITP 2 A ITSM 1.2 A Tj 115 °C Storage temperature range Tstg -55~125 °C Operating temperature range Topr -40~100 °C Lead soldering temperature (10s) Tsol 260 °C BVS 2500 Vrms On-state current derating (Ta ≥ 25°C) Peak on-state current (100µs pulse, 120 pps) Peak nonrepetitive surge current (PW=10ms, DC=10%) Junction temperature Isolation voltage (AC, 1 min., R.H. ≤ 60%) (Note 2) (Note 2) Device considered a two terminal device: Pins 1 and 3 shorted together and 4 and 6 shorted together. Recommended Operating Conditions Characteristic Symbol Min. Typ. Max. Unit Supply voltage VAC ― ― 240 Vac Forward current IF 15 20 25 mA Peak on-state current ITP ― ― 1 A Operating temperature Topr -25 ― 85 °C 2 2002-09-25 TLP165J Electrical Characteristics (Ta = 25°C) Detector LED Characteristic Symbol Test Condition Min. Typ. Max. Unit Forward voltage VF IF=10mA 1.0 1.15 1.3 V Reverse current IR VR=5V ― ― 10 µA Capacitance CT V=0, f=1MHz ― 30 ― pF Peak off-state current IDRM VDRM=600V ― 10 1000 nA Peak on-state voltage VTM ITM=70mA ― 1.7 2.8 V ― 1.0 ― mA Holding current IH Critical rate of rise of off-state voltage Critical rate of rise of commutating voltage ― dv / dt Vin=240Vrms, Ta=85°C (Note 3) ― 500 ― V / µs dv / dt(c) IT=15mA, Vin=60Vrms (Note 3) ― 0.2 ― V / µs Min. Typ. Max. Unit ― 10 mA 0.8 ― pF 10 ― Ω 2500 ― ― AC, 1 second, in oil ― 5000 ― DC, 1 minute, in oil ― 5000 ― Vdc VD=6→4V, RL = 100Ω IF=Rated IFT×1.5 ― ― 100 µs Coupled Electrical Characteristics (Ta = 25°C) Characteristic Symbol Test Condition Trigger LED current IFT VT=6V ― Capacitance input to output Cs VS=0, f=1MHz ― Isolation resistance RS 12 VS=500V, R.H. ≤ 60% 1×10 AC, 1 minute Isolation voltage BVS Turn-on time tON 14 Vrms (Note 3) dv / dt test circuit Rin VCC + - 120Ω Vin 1 6 3 4 RL 5V,VCC 0V ~ dv / dt (c) 4KΩ 3 dv / dt 2002-09-25 TLP165J RESTRICTIONS ON PRODUCT USE 000707EBC · TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.. · The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with domestic garbage. · The products described in this document are subject to the foreign exchange and foreign trade laws. · The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others. · The information contained herein is subject to change without notice. 4 2002-09-25