TOSHIBA TLP165J

TLP165J
TOSHIBA Photocoupler GaAs Ired & Photo−Triac
TLP165J
Triac Drive
Programmable Controllers
AC−Output Module
Solid State Relay
Unit in mm
The TOSHIBA mini flat coupler TLP165J is a small outline coupler,
suitable for surface mount assembly.
The TLP165J consists of a photo triac, optically coupled to a gallium
arsenide infrared emitting diode.
·
Peak off−state voltage: 600 V (min.)
·
Trigger LED current: 10 mA (max.)
·
On−state current: 70 mA (max.)
·
Isolation voltage: 2500 Vrms (min.)
·
UL recognized: UL1577, file no. E67349
·
Option(V4)type
TOSHIBA
VDE approved: VDE 0884 satisfied
11−4C3
Weight: 0.09 g
Maximum operating insulation voltage: 565Vpk
Highest permissible over voltage: 4000Vpk
Trigger LED Current
Type
(Note 1)
Pin Configurations
Trigger LED Current (mA)
VT=6V, Ta=25°C
Min.
Max.
Marking Of
Classification
(IFT7)
―
7
T7
None
―
10
T7, blank
*
Exp. rank IFT7: TLP165J (IFT7)
(Note 1) Application type name for certification test, please use standard product
type name, i.e.
TLP165J(IFT7): TLP165J
1
1
6
3
4
1 . Anode
3 . Cathode
4 . Terminal 1
6 . Terminal 2
2002-09-25
TLP165J
Maximum Ratings (Ta = 25°C)
Characteristic
Symbol
Rating
Unit
IF
50
mA
∆IF / °C
-0.7
mA / °C
Peak forward current (100µs pulse, 100 pps)
IFP
1
A
Reverse voltage
VR
5
V
Junction temperature
Tj
125
°C
VDRM
600
V
Forward current
LED
Forward current derating (Ta ≥ 53°C)
Off- state output terminal voltage
Detector
On-state RMS current
Ta=25°C
70
IT(RMS)
Ta=70°C
mA
40
∆IT / °C
-0.67
mA / °C
ITP
2
A
ITSM
1.2
A
Tj
115
°C
Storage temperature range
Tstg
-55~125
°C
Operating temperature range
Topr
-40~100
°C
Lead soldering temperature (10s)
Tsol
260
°C
BVS
2500
Vrms
On-state current derating (Ta ≥ 25°C)
Peak on-state current (100µs pulse, 120 pps)
Peak nonrepetitive surge current
(PW=10ms, DC=10%)
Junction temperature
Isolation voltage (AC, 1 min., R.H. ≤ 60%)
(Note 2)
(Note 2) Device considered a two terminal device: Pins 1 and 3 shorted together and 4
and 6 shorted together.
Recommended Operating Conditions
Characteristic
Symbol
Min.
Typ.
Max.
Unit
Supply voltage
VAC
―
―
240
Vac
Forward current
IF
15
20
25
mA
Peak on-state current
ITP
―
―
1
A
Operating temperature
Topr
-25
―
85
°C
2
2002-09-25
TLP165J
Electrical Characteristics (Ta = 25°C)
Detector
LED
Characteristic
Symbol
Test Condition
Min.
Typ.
Max.
Unit
Forward voltage
VF
IF=10mA
1.0
1.15
1.3
V
Reverse current
IR
VR=5V
―
―
10
µA
Capacitance
CT
V=0, f=1MHz
―
30
―
pF
Peak off-state current
IDRM
VDRM=600V
―
10
1000
nA
Peak on-state voltage
VTM
ITM=70mA
―
1.7
2.8
V
―
1.0
―
mA
Holding current
IH
Critical rate of rise
of off-state voltage
Critical rate of rise
of commutating voltage
―
dv / dt
Vin=240Vrms, Ta=85°C
(Note 3)
―
500
―
V / µs
dv / dt(c)
IT=15mA, Vin=60Vrms
(Note 3)
―
0.2
―
V / µs
Min.
Typ.
Max.
Unit
―
10
mA
0.8
―
pF
10
―
Ω
2500
―
―
AC, 1 second, in oil
―
5000
―
DC, 1 minute, in oil
―
5000
―
Vdc
VD=6→4V, RL = 100Ω
IF=Rated IFT×1.5
―
―
100
µs
Coupled Electrical Characteristics (Ta = 25°C)
Characteristic
Symbol
Test Condition
Trigger LED current
IFT
VT=6V
―
Capacitance input to output
Cs
VS=0, f=1MHz
―
Isolation resistance
RS
12
VS=500V, R.H. ≤ 60%
1×10
AC, 1 minute
Isolation voltage
BVS
Turn-on time
tON
14
Vrms
(Note 3) dv / dt test circuit
Rin
VCC
+
-
120Ω
Vin
1
6
3
4
RL
5V,VCC
0V
~
dv / dt (c)
4KΩ
3
dv / dt
2002-09-25
TLP165J
RESTRICTIONS ON PRODUCT USE
000707EBC
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes
are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the
products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with
domestic garbage.
· The products described in this document are subject to the foreign exchange and foreign trade laws.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
4
2002-09-25