TMP106 Chip-Scale Package SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 Digital Temperature Sensor with Two-Wire Interface FEATURES D D D D DESCRIPTION TWO ADDRESSES DIGITAL OUTPUT: Two-Wire Serial Interface RESOLUTION: 9- to 12-Bits, User-Selectable ACCURACY: ±2.0°C (max) from −25°C to +85°C ±3.0°C (max) from −40°C to +125°C D LOW QUIESCENT CURRENT: 50µA, 0.1µA Standby D NO POWER-UP SEQUENCE REQUIRED, I2C PULLUPS CAN BE ENABLED PRIOR TO V+ APPLICATIONS D NOTEBOOK COMPUTERS D COMPUTER PERIPHERAL THERMAL PROTECTION D D D D The TMP106 is a two-wire, serial output temperature sensor available in a WCSP package. Requiring no external components, the TMP106 is capable of reading temperatures with a resolution of 0.0625°C. The TMP106 features a Two-Wire interface that is SMBus-compatible, with the TMP106 allowing up to two devices on one bus. The TMP106 also features an SMBus Alert function. The TMP106 is ideal for extended temperature measurement in a variety of communication, computer, consumer, environmental, industrial, and instrumentation applications. The TMP106 is specified for operation over a temperature range of −40°C to +125°C. CELL PHONES BATTERY MANAGEMENT THERMOSTAT CONTROLS ENVIRONMENTAL MONITORING AND HVAC Temperature YZC LEAD−FREE 2 X 3 ARRAY (TOP VIEW) 1,65 mm 1,50 mm SDA SDA A1 A2 GND SCL B1 B2 ALERT V+ C1 C2 A0 SCL V+ 1,15 mm 1,00 mm A1 B1 Diode Temp. Sensor Control Logic ∆Σ A/D Converter Serial Interface OSC Config. and Temp. Register A2 B2 C1 C2 GND ALERT A0 (Bump Side Down) TMP106 Note: Pin A1 is marked with a ‘0’ for Pb−free (YZC) Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. All trademarks are the property of their respective owners. Copyright 2005−2006, Texas Instruments Incorporated ! ! www.ti.com "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 ABSOLUTE MAXIMUM RATINGS(1) Power Supply, V+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.0V Input Voltage(2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5V to 7.0V Input Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10mA Operating Temperature Range . . . . . . . . . . . . . . . −55°C to +127°C Storage Temperature Range . . . . . . . . . . . . . . . . . −60°C to +130°C Junction Temperature (TJ max) . . . . . . . . . . . . . . . . . . . . . . +150°C ESD Rating(3): Human Body Model (HBM) . . . . . . . . . . . . . . . . . . . . . . . 2000V Charged-Device Model (CDM) . . . . . . . . . . . . . . . . . . . . . . 500V Machine Model (MM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200V (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not supported. (2) Input voltage rating applies to all TMP106 input voltages. This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. (3) ESD testing has been tested to TI specifications JEDEC J−Std 020. ORDERING INFORMATION(1) PACKAGE PART NUMBER SYMBOL Wafer chip-scale package (YZC) TMP106YZC F7 (1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI website at www.ti.com. PIN ASSIGNMENTS WCSP−6 PACKAGE (TOP VIEW) SDA A1 A2 GND SCL B1 B2 ALERT V+ C1 C2 A0 (Bump Side Down) Note: Pin 1 is determined by orienting the package marking as indicated in the diagram. 2 "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 ELECTRICAL CHARACTERISTICS At TA = −40°C to +125°C, and V+ = 2.7V to 5.5V, unless otherwise noted. TMP106 PARAMETER CONDITION MIN TYP MAX UNITS TEMPERATURE INPUT +125 °C −25°C to +85°C ±0.5 ±2.0 °C −40°C to +125°C ±1.0 ±3.0 °C 0.2 ±0.5 °C/V Range −40 Accuracy (Temperature Error) vs Supply Resolution(1) Selectable 0.0625 °C 3 pF DIGITAL INPUT/OUTPUT Input Capacitance Input Logic Levels: VIH VIL 2.1 6.0 −0.5 0.8 V 1 µA 0V ≤ VIN ≤ 6V Leakage Input Current, IIN Input Voltage Hysteresis SCL and SDA Pins 250 V mV Output Logic Levels: VOL SDA VOL ALERT IOL = 3mA IOL = 4mA Resolution Conversion Time 0 0.15 0.4 V 0 0.15 0.4 V Selectable 9 to 12 9-Bit 27.5 37.5 ms 10-Bit 55 75 ms 11-Bit 110 150 ms 12-Bit 220 300 ms 54 74 ms Timeout Time 25 Bits POWER SUPPLY Operating Range Quiescent Current Shutdown Current 2.7 IQ ISD Serial Bus Inactive 50 5.5 V 85 µA µA Serial Bus Active, SCL Freq = 400kHz 100 Serial Bus Active, SCL Freq = 3.4MHz 410 Serial Bus Inactive 0.1 Serial Bus Active, SCL Freq = 400kHz 60 µA Serial Bus Active, SCL Freq = 3.4MHz 380 µA µA 3 µA TEMPERATURE RANGE Specified Range −40 +125 Operating Range −55 +127 Thermal Resistance qJA 240 °C °C °C/W (1) Specified for 12-bit resolution. 3 "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 TYPICAL CHARACTERISTICS At TA = +25°C and V+ = 5.0V, unless otherwise noted. SHUTDOWN CURRENT vs TEMPERATURE QUIESCENT CURRENT vs TEMPERATURE 60 1.0 V+ = 2.8V 0.9 V+ = 5V 50 0.8 0.7 0.6 ISD (µA) IQ (µA) 40 V+ = 2.7V 30 0.5 0.4 0.3 20 0.2 0.1 10 0.0 Serial Bus Inactive −0.1 0 −50 −25 0 25 50 75 100 −55 125 −35 −15 5 25 45 65 85 105 125 Temperature (_ C) Temperature (_ C) TEMPERATURE ACCURACY vs TEMPERATURE CONVERSION TIME vs TEMPERATURE 300 2.0 250 Temperature Error (_ C) Conversion Time (ms) 1.5 V+ = 5V 200 V+ = 2.7V 150 1.0 0.5 0.0 −0.5 −1.0 −1.5 12−bit resolution. 100 −50 −25 0 25 50 75 100 −2.0 −55 125 3 typical units 12−bit resolution. −35 −15 5 QUIESCENT CURRENT WITH BUS ACTIVITY vs TEMPERATURE 500 Hs MODE FAST MODE 450 400 I Q (µA) 350 300 250 200 125_C 150 25_ C 100 50 −55_C 0 1k 10k 100k Frequency (Hz) 4 25 45 65 Temperature (_ C) Temperature (_ C) 1M 10M 85 105 125 "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 APPLICATIONS INFORMATION The TMP106 is a digital temperature sensor that is optimal for thermal management and thermal protection applications. The TMP106 is Two-Wire and SMBus interface-compatible, and is specified over a temperature range of −40°C to +125°C. Pointer Register Temperature Register The TMP106 requires no external components for operation except for pull-up resistors on SCL, SDA, and ALERT, although a 0.1µF bypass capacitor is recommended, as shown in Figure 1. SCL Configuration Register V+ I/O Control Interface TLOW Register SDA 0.1µF C1 To Two−Wire Controller SCL B1 SDA A1 TMP106 THIGH Register C2 A0 B2 Figure 2. Internal Register Structure of the TMP106 ALERT (Output) A2 GND NOTE: SCL, SDA, and ALERT pins require pull−up resistors. P1 P0 0 0 Temperature Register (Read Only) 0 1 Configuration Register (Read/Write) 1 0 1 1 TLOW Register (Read/Write) THIGH Register (Read/Write) Figure 1. Typical Connections of the TMP106 The sensing device of the TMP106 is the chip itself. Thermal paths run through the package leads. The lower thermal resistance of metal causes the leads to provide the primary thermal path. To maintain accuracy in applications requiring air or surface temperature measurement, care should be taken to isolate the package and leads from ambient air temperature. POINTER REGISTER Figure 2 shows the internal register structure of the TMP106. The 8-bit Pointer Register of the device is used to address a given data register. The Pointer Register uses the two LSBs to identify which of the data registers should respond to a read or write command. Table 1 identifies the bits of the Pointer Register byte. Table 2 describes the pointer address of the registers available in the TMP106. Power-up reset value of P1/P0 is 00. P7 P6 P5 P4 P3 P2 0 0 0 0 0 0 P1 P0 Register Bits Table 1. Pointer Register Byte REGISTER Table 2. Pointer Addresses of the TMP106 TEMPERATURE REGISTER The Temperature Register of the TMP106 is a 12-bit, read-only register that stores the output of the most recent conversion. Two bytes must be read to obtain data, and are described in Table 3 and Table 4. Note that byte 1 is the most significant byte; byte 2 is the least significant byte. The first 12 bits are used to indicate temperature, with all remaining bits equal to zero. The least significant byte does not have to be read if that information is not needed. Data format for temperature is summarized in Table 5. Following power-up or reset, the Temperature Register will read 0°C until the first conversion is complete. D7 D6 D5 D4 D3 D2 D1 D0 T11 T10 T9 T8 T7 T6 T5 T4 Table 3. Byte 1 of Temperature Register D7 D6 D5 D4 D3 D2 D1 D0 T3 T2 T1 T0 0 0 0 0 Table 4. Byte 2 of Temperature Register 5 "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 POLARITY (POL) TEMPERATURE (°C) DIGITAL OUTPUT (BINARY) HEX 128 0111 1111 1111 7FF 127.9375 0111 1111 1111 7FF 100 0110 0100 0000 640 80 0101 0000 0000 500 75 0100 1011 0000 4B0 50 0011 0010 0000 320 25 0001 1001 0000 190 0.25 0000 0000 0100 004 0 0000 0000 0000 000 −0.25 1111 1111 1100 FFC −25 1110 0111 0000 E70 −55 1100 1001 0000 C90 The Polarity Bit of the TMP106 allows the user to adjust the polarity of the ALERT pin output. If POL = 0, the ALERT pin will be active LOW, as shown in Figure 3. For POL = 1, the ALERT pin will be active HIGH, and the state of the ALERT pin is inverted. THIGH Measured Temperature TLOW Table 5. Temperature Data Format TMP106 ALERT PIN (Comparator Mode) POL = 0 The user can obtain 9, 10, 11, or 12 bits of resolution by addressing the Configuration Register and setting the resolution bits accordingly. For 9-, 10-, or 11-bit resolution, the most significant bits in the Temperature Register are used with the unused LSBs set to zero. TMP106 ALERT PIN (Interrupt Mode) POL = 0 TMP106 ALERT PIN (Comparator Mode) POL = 1 TMP106 ALERT PIN (Interrupt Mode) POL = 1 CONFIGURATION REGISTER The Configuration Register is an 8-bit read/write register used to store bits that control the operational modes of the temperature sensor. Read/write operations are performed MSB first. The format of the Configuration Register for the TMP106 is shown in Table 6, followed by a breakdown of the register bits. The power-up/reset value of the Configuration Register is all bits equal to 0. Read Read Read Time Figure 3. Output Transfer Function Diagrams FAULT QUEUE (F1/F0) BYTE D7 D6 D5 D4 D3 D2 D1 D0 1 OS R1 R0 F1 F0 POL TM SD Table 6. Configuration Register Format SHUTDOWN MODE (SD) The Shutdown Mode of the TMP106 allows the user to save maximum power by shutting down all device circuitry other than the serial interface, which reduces current consumption to typically less than 0.1µA. Shutdown Mode is enabled when the SD bit is 1; the device will shut down once the current conversion is completed. When SD is equal to 0, the device will maintain a continuous conversion state. THERMOSTAT MODE (TM) The Thermostat Mode bit of the TMP106 indicates to the device whether to operate in Comparator Mode (TM = 0) or Interrupt Mode (TM = 1). For more information on comparator and interrupt modes, see the High and Low Limit Registers section. 6 A fault condition is defined as when the measured temperature exceeds the user-defined limits set in the THIGH and TLOW Registers. Additionally, the number of fault conditions required to generate an alert may be programmed using the fault queue. The fault queue is provided to prevent a false alert as a result of environmental noise. The fault queue requires consecutive fault measurements in order to trigger the alert function. Table 7 defines the number of measured faults that may be programmed to trigger an alert condition in the device. For THIGH and TLOW register format and byte order, see the High and Low Limit Registers section. F1 F0 CONSECUTIVE FAULTS 0 0 1 0 1 2 1 0 4 1 1 6 Table 7. Fault Settings of the TMP106 "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 CONVERTER RESOLUTION (R1/R0) The Converter Resolution bits control the resolution of the internal analog-to-digital (A/D) converter. This control allows the user to maximize efficiency by programming for higher resolution or faster conversion time. Table 8 identifies the resolution bits and the relationship between resolution and conversion time. R1 R0 RESOLUTION CONVERSION TIME (typical) 0 0 9 Bits (0.5°C) 27.5ms 0 1 10 Bits (0.25°C) 55ms 1 0 11 Bits (0.125°C) 110ms 1 1 12 Bits (0.0625°C) 220ms Table 8. Resolution of the TMP106 ONE-SHOT (OS) The TMP106 features a One-Shot Temperature Measurement Mode. When the device is in Shutdown Mode, writing a ‘1’ to the OS bit starts a single temperature conversion. The device will return to the shutdown state at the completion of the single conversion. This option is useful to reduce power consumption in the TMP106 when continuous temperature monitoring is not required. When the Configuration Register is read, the OS always reads zero. HIGH AND LOW LIMIT REGISTERS In Comparator Mode (TM = 0), the ALERT pin of the TMP106 becomes active when the temperature equals or exceeds the value in THIGH and generates a consecutive number of faults according to fault bits F1 and F0. The ALERT pin remains active until the temperature falls below the indicated TLOW value for the same number of faults. In Interrupt Mode (TM = 1), the ALERT pin becomes active when the temperature equals or exceeds THIGH for a consecutive number of fault conditions. The ALERT pin remains active until a read operation of any register occurs, or until the device successfully responds to the SMBus Alert Response address. The ALERT pin clears if the device is placed in Shutdown Mode. Once the ALERT pin is cleared, it will only become active again by the temperature falling below TLOW. When the temperature falls below TLOW, the ALERT pin becomes active and remains active until cleared by a read operation of any register or a successful response to the SMBus Alert Response address. When the ALERT pin clears, the above cycle will repeat, with the ALERT pin becoming active when the temperature equals or exceeds THIGH. The ALERT pin can also be cleared by resetting the device with the General Call Reset command. This reset also clears the state of the internal registers in the device, returning the device to Comparator Mode (TM = 0). Both operational modes are represented in Figure 3. Table 9 and Table 10 describe the format for the THIGH and TLOW Registers. Note that the most significant byte is sent first, followed by the least significant byte. Power-up reset values for THIGH and TLOW are: THIGH = 80°C and TLOW = 75°C The format of the data for THIGH and TLOW is the same as for the Temperature Register. BYTE D7 D6 D5 D4 D3 D2 D1 D0 1 H11 H10 H9 H8 H7 H6 H5 H4 BYTE D7 D6 D5 D4 D3 D2 D1 D0 2 H3 H2 H1 H0 0 0 0 0 Table 9. Bytes 1 and 2 of THIGH Register BYTE D7 D6 D5 D4 D3 D2 D1 D0 1 L11 L10 L9 L8 L7 L6 L5 L4 BYTE D7 D6 D5 D4 D3 D2 D1 D0 2 L3 L2 L1 L0 0 0 0 0 Table 10. Bytes 1 and 2 of TLOW Register All 12 bits for the Temperature, THIGH, and TLOW Registers are used in the comparisons for the ALERT function for all converter resolutions. The three LSBs in THIGH and TLOW can affect the ALERT output even if the converter is configured for 9-bit resolution. SERIAL INTERFACE The TMP106 operates only as a slave device on the Two-Wire bus and SMBus. Connections to the bus are made via the open-drain I/O lines SDA and SCL. The SDA and SCL pins feature integrated spike suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The TMP106 supports the transmission protocol for fast (1kHz to 400kHz) and high-speed (1kHz to 3.4MHz) modes. All data bytes are transmitted MSB first. 7 "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 SERIAL BUS ADDRESS To communicate with the TMP106, the master must first address slave devices via a slave address byte. The slave address byte consists of seven address bits, and a direction bit indicating the intent of executing a read or write operation. The TMP106 features one address pin allowing up to two devices to be connected per bus. Pin logic levels are described in Table 11. The address pin of the TMP106 is read after reset, at start of communication, or in response to a Two-Wire address acquire request. Following the reading of the pin state, the address is latched to minimize power dissipation associated with detection. A0 SLAVE ADDRESS 0 1001000 1 1001001 Table 11. Address Pin and Slave Addresses for the TMP106 BUS OVERVIEW The device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates the START and STOP conditions. To address a specific device, a START condition is initiated, indicated by pulling the data-line (SDA) from a HIGH to LOW logic level while SCL is HIGH. All slaves on the bus shift in the slave address byte, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed responds to the master by generating an Acknowledge and pulling SDA LOW. 8 Data transfer is then initiated and sent over eight clock pulses followed by an Acknowledge Bit. During data transfer SDA must remain stable while SCL is HIGH, as any change in SDA while SCL is HIGH will be interpreted as a control signal. Once all data has been transferred, the master generates a STOP condition, indicated by pulling SDA from LOW to HIGH while SCL is HIGH. WRITING/READING TO THE TMP106 Accessing a particular register on the TMP106 is accomplished by writing the appropriate value to the Pointer Register. The value for the Pointer Register is the first byte transferred after the slave address byte with the R/W bit LOW. Every write operation to the TMP106 requires a value for the Pointer Register. (Refer to Figure 5.) When reading from the TMP106, the last value stored in the Pointer Register by a write operation is used to determine which register is read by a read operation. To change the register pointer for a read operation, a new value must be written to the Pointer Register. This is accomplished by issuing a slave address byte with the R/W bit LOW, followed by the Pointer Register byte. No additional data are required. The master can then generate a START condition and send the slave address byte with the R/W bit HIGH to initiate the read command. See Figure 6 for details of this sequence. If repeated reads from the same register are desired, it is not necessary to continually send the Pointer Register byte, as the TMP106 remembers the Pointer Register value until it is changed by the next write operation. Note that register bytes are sent most-significant byte first, followed by the least-significant byte. "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 SLAVE MODE OPERATIONS The TMP106 can operate as a slave receiver or slave transmitter. Slave Receiver Mode: The first byte transmitted by the master is the slave address, with the R/W bit LOW. The TMP106 then acknowledges reception of a valid address. The next byte transmitted by the master is the Pointer Register. The TMP106 then acknowledges reception of the Pointer Register byte. The next byte or bytes are written to the register addressed by the Pointer Register. The TMP106 acknowledges reception of each data byte. The master may terminate data transfer by generating a START or STOP condition. Slave Transmitter Mode: The first byte is transmitted by the master and is the slave address, with the R/W bit HIGH. The slave acknowledges reception of a valid slave address. The next byte is transmitted by the slave and is the most significant byte of the register indicated by the Pointer Register. The master acknowledges reception of the data byte. The next byte transmitted by the slave is the least significant byte. The master acknowledges reception of the data byte. The master may terminate data transfer by generating a Not-Acknowledge on reception of any data byte, or generating a START or STOP condition. SMBus ALERT FUNCTION The TMP106 supports the SMBus Alert function. When the TMP106 is operating in Interrupt Mode (TM = 1), the ALERT pin of the TMP106 may be connected as an SMBus Alert signal. When a master senses that an ALERT condition is present on the ALERT line, the master sends an SMBus Alert command (00011001) on the bus. If the ALERT pin of the TMP106 is active, the devices will acknowledge the SMBus Alert command and respond by returning its slave address on the SDA line. The eighth bit (LSB) of the slave address byte will indicate if the temperature exceeding THIGH or falling below TLOW caused the ALERT condition. This bit will be HIGH if the temperature is greater than or equal to THIGH. This bit will be LOW if the temperature is less than TLOW. Refer to Figure 7 for details of this sequence. If multiple devices on the bus respond to the SMBus Alert command, arbitration during the slave address portion of the SMBus Alert command will determine which device will clear its ALERT status. If the TMP106 wins the arbitration, its ALERT pin will become inactive at the completion of the SMBus Alert command. If the TMP106 loses the arbitration, its ALERT pin will remain active. GENERAL CALL The TMP106 responds to a Two-Wire General Call address (0000000) if the eighth bit is 0. The device will acknowledge the General Call address and respond to commands in the second byte. If the second byte is 00000100, the TMP106 will latch the status of the address pin, but will not reset. If the second byte is 00000110, the TMP106 will latch the status of the address pin and reset the internal registers to their power-up values. HIGH-SPEED MODE In order for the Two-Wire bus to operate at frequencies above 400kHz, the master device must issue an Hs-mode master code (00001XXX) as the first byte after a START condition to switch the bus to high-speed operation. The TMP106 will not acknowledge this byte, but will switch its input filters on SDA and SCL and its output filters on SDA to operate in Hs-mode, allowing transfers at up to 3.4MHz. After the Hs-mode master code has been issued, the master will transmit a Two-Wire slave address to initiate a data transfer operation. The bus will continue to operate in Hs-mode until a STOP condition occurs on the bus. Upon receiving the STOP condition, the TMP106 will switch the input and output filters back to fast-mode operation. TIMEOUT FUNCTION The TMP106 will reset the serial interface if either SCL or SDA are held LOW for 54ms (typ) between a START and STOP condition. The TMP106 will release the bus if it is pulled LOW and will wait for a START condition. To avoid activating the timeout function, it is necessary to maintain a communication speed of at least 1kHz for SCL operating frequency. 9 "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 TIMING DIAGRAMS Data Transfer: The number of data bytes transferred between a START and a STOP condition is not limited and is determined by the master device. The receiver acknowledges the transfer of data. The TMP106 is Two-Wire- and SMBus-compatible. Figure 4 to Figure 7 describe the various operations on the TMP106. Bus definitions are given below. Parameters for Figure 4 are defined in Table 12. Acknowledge: Each receiving device, when addressed, is obliged to generate an Acknowledge bit. A device that acknowledges must pull down the SDA line during the Acknowledge clock pulse in such a way that the SDA line is stable LOW during the HIGH period of the Acknowledge clock pulse. Setup and hold times must be taken into account. On a master receive, the termination of the data transfer can be signaled by the master generating a Not-Acknowledge on the last byte that has been transmitted by the slave. Bus Idle: Both SDA and SCL lines remain HIGH. Start Data Transfer: A change in the state of the SDA line, from HIGH to LOW, while the SCL line is HIGH, defines a START condition. Each data transfer is initiated with a START condition. Stop Data Transfer: A change in the state of the SDA line from LOW to HIGH while the SCL line is HIGH defines a STOP condition. Each data transfer is terminated with a repeated START or STOP condition. FAST MODE PARAMETER SCL Operating Frequency Bus Free Time Between STOP and START Condition Hold time after repeated START condition. After this period, the first clock is generated. Repeated START Condition Setup Time STOP Condition Setup Time Data Hold Time Data Setup Time SCL Clock LOW Period SCL Clock HIGH Period UNITS MIN MAX MIN MAX f(SCL) t(BUF) 0.001 0.4 0.001 3.4 600 160 ns t(HDSTA) 100 100 ns t(SUSTA) t(SUSTO) t(HDDAT) 100 100 ns 100 100 ns 0 0 ns t(SUDAT) t(LOW) 100 10 ns 1300 160 ns 600 60 t(HIGH) tF Clock/Data Fall Time HIGH-SPEED MODE Clock/Data Rise Time for SCLK ≤ 100kHz tR MHz ns 300 160 ns 300 1000 160 ns ns Table 12. Timing Diagram Definitions for the TMP106 TWO-WIRE TIMING DIAGRAMS t(LOW) tF tR t(HDSTA) SCL t(HDSTA) t(HIGH) t(HDDAT) t(SUSTO) t(SUSTA) t(SUDAT) SDA t(BU F ) P S S Figure 4. Two-Wire Timing Diagram 10 P "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 1 9 1 9 … SCL 1 SDA 0 0 1 0 0 A0 R/W Start By Master 0 0 0 0 0 0 P1 … P0 ACK By TMP106 ACK By TMP106 Frame 2 Pointer Register Byte Frame 1 Two−Wire Slave Address Byte 1 1 9 9 SCL (Continued) SDA (Continued) D7 D6 D5 D4 D3 D2 D1 D7 D0 D6 D5 D4 D3 D2 D1 D0 ACK By TMP106 ACK By TMP106 Stop By Master Frame 4 Data Byte 2 Frame 3 Data Byte 1 Figure 5. Two-Wire Timing Diagram for TMP106 Write Word Format 1 9 1 9 … SCL SDA 1 0 0 0 0 A0 R/W Start By Master 0 0 0 0 0 0 P1 … P0 ACK By TMP106 ACK By TMP106 Frame 1 Two−Wire Slave Address Byte Frame 2 Pointer Register Byte 1 9 1 9 … SCL (Continued) SDA (Continued) 1 0 0 1 0 0 A0 D7 R/W Start By Master ACK By TMP106 Frame 3 Two−Wire Slave Address Byte 1 D6 D5 D4 D3 D2 D1 D0 From TMP106 … ACK By Master Frame 4 Data Byte 1 Read Register 9 SCL (Continued) SDA (Continued) D7 D6 D5 D4 D3 D2 D1 D0 From TMP106 ACK By Master Stop By Master Frame 5 Data Byte 2 Read Register Figure 6. Two-Wire Timing Diagram for Read Word Format 11 "#$% www.ti.com SLLS672A − OCTOBER 2005 − REVISED JANUARY 2006 ALERT 1 9 1 9 SCL SDA Start By Master 0 0 0 1 1 0 0 R/W 1 0 0 1 0 ACK By TMP106 Frame 1 SMBus ALERT Response Address Byte A0 From TMP106 Frame 2 Slave Address Byte Figure 7. Timing Diagram for SMBus ALERT 12 0 Status NACK By Master Stop By Master 13 PACKAGE OPTION ADDENDUM www.ti.com 31-Jul-2006 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty TMP106YZCR ACTIVE DSBGA YZC 6 TMP106YZCRG4 ACTIVE DSBGA YZC 6 TMP106YZCT ACTIVE DSBGA YZC 6 TMP106YZCTG4 ACTIVE DSBGA YZC 6 3000 Green (RoHS & no Sb/Br) 250 Lead/Ball Finish MSL Peak Temp (3) Call TI Level-1-260C-UNLIM TBD Call TI Call TI Green (RoHS & no Sb/Br) Call TI Level-1-260C-UNLIM TBD Call TI Call TI (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security Low Power Wireless www.ti.com/lpw Mailing Address: Telephony www.ti.com/telephony Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2006, Texas Instruments Incorporated