Special Load PCB Relay 409 47, 409 67 1 pole 10 A, for high inrush currents, mono- or bistable Features • • • • • Specifically designed to handle high inrush currents Tungsten prerun contact 500 A / 10 ms inrush peak current 4 kV / 8 mm coil-contact meets protection class II requirements Applications Dimmer switches, movement sensors, filament loads, halogen bulbs, motors and electrovalves Z (409 47 only) Technical data of approved types on request F0249-A Contact data Contact ratings Type Load 409 10 A, 250 Vac, resistive 409 1300 W, fluorescent lamps, 140 µF 409 2500 W, incandescent lamps 409 1000 W, Dulux lamps, 140 µF Coil data Edition: 07/2004 Nominal voltage Nominal coil power Operate category 1 N/O contact single contact 10 A 250 Vac / 400 Vac 2500 VA 16 A 500 / 120 A W (prerun contact) + AgCdO Operations 2.5x105 3x104 3x104 3x104 Standard monostable DC coil 5...110 Vdc 820 mW 2/b Coil versions monostable Coil Nominal Pull-in Release Maximum code voltage voltage voltage voltage Vdc Vdc Vdc Vdc 031 12 7.5 0.9 14.2 027 24 18.0 1.8 34.6 024 48 34.5 3.6 60.6 023 60 41.0 4.5 77.8 All figures are given for coil without preenergization, at ambient Other coil voltages on request Coil Coil resistance current c mA 170+10% 71.0 880+15% 27.0 2700+15% 18.0 4400+15% 14.0 temperature +20°C Rights to change data / design reserved Configuration Type of contact Rated current Rated voltage / max.breaking voltage AC Maximum breaking capacity AC Make current (max. 4 s at duty cycle 10%) peak inrush current 10 µs / 20 ms Contact material Special Load PCB Relay 409 47, 409 67 1 pole 10 A, for high inrush currents, mono- or bistable Coil data bistable 1 coil Nominal voltage Nominal coil power Minimum energization time Max. energization time 6...100 Vdc 0.8...1 W 20 ms 1 min at < 10% duty cycle Coil versions bistable, 1 coil Coil Nominal Pull-in Reset Reset Coil Coil code voltage voltage voltage voltage resistance current Vdc Vdc min Vdc max Vdc c mA 032 12 8.9 -2.5 -3.5 118+10% 102.0 029 24 18.0 -5.0 -7.0 457+10% 53.0 All figures are given for coil without preenergization, at ambient temperature +20°C, duty cycle 20% Other coil voltages on request Insulation Dielectric strength coil-contacts open contact circuit Clearance / creepage Insulation to VDE 0110b (2/79) Insulation category / reference voltage Tracking resistance of relay base 4000 Vrms 1000 Vrms 8 / 8 mm C / 250 PTI 250 PCB layout / terminal assignment Edition: 07/2004 Other data Flammability class according to UL 94 Ambient temperature Mechanical life Max. switching rate at rated- / minimum load Operate- / release time Bounce time Vibration resistance Shock resistance (destruction) Category of protection (IEC 61810) Relay weight Packaging unit S0163-CX V-0 -20...+70 °C 30x106 operations 15 min-1 / 1200 min-1 typ. 10 / 3 ms typ. 3 ms 20 g (30...300 Hz) 100 g RT II - flux proof 16 g 25 / 250 pcs. S0163-BF Bistable versions: Indicated contact position during or after coil energization with reset voltage. Rights to change data / design reserved Bottom view on solder pins Dimensions in mm Special Load PCB Relay 409 47, 409 67 1 pole 10 A, for high inrush currents, mono- or bistable Dimensions Dimensions in mm 0409 67 002 000 0409 67 003 000 is identical with is identical with 0409 67 032 001 0409 67 029 001 Rights to change data / design reserved Edition: 07/2004 S0273-AI