MA-COM 040967003000

Special Load PCB Relay 409 47, 409 67
1 pole 10 A, for high inrush currents,
mono- or bistable
Features
•
•
•
•
•
Specifically designed to handle high inrush currents
Tungsten prerun contact
500 A / 10 ms inrush peak current
4 kV / 8 mm coil-contact
meets protection class II requirements
Applications
Dimmer switches, movement sensors, filament loads, halogen
bulbs, motors and electrovalves
Z
(409 47 only)
Technical data of approved types on request
F0249-A
Contact data
Contact ratings
Type
Load
409
10 A, 250 Vac, resistive
409
1300 W, fluorescent lamps, 140 µF
409
2500 W, incandescent lamps
409
1000 W, Dulux lamps, 140 µF
Coil data
Edition: 07/2004
Nominal voltage
Nominal coil power
Operate category
1 N/O contact
single contact
10 A
250 Vac / 400 Vac
2500 VA
16 A
500 / 120 A
W (prerun contact) + AgCdO
Operations
2.5x105
3x104
3x104
3x104
Standard
monostable DC coil
5...110 Vdc
820 mW
2/b
Coil versions monostable
Coil
Nominal
Pull-in
Release
Maximum
code
voltage
voltage
voltage
voltage
Vdc
Vdc
Vdc
Vdc
031
12
7.5
0.9
14.2
027
24
18.0
1.8
34.6
024
48
34.5
3.6
60.6
023
60
41.0
4.5
77.8
All figures are given for coil without preenergization, at ambient
Other coil voltages on request
Coil
Coil
resistance
current
c
mA
170+10%
71.0
880+15%
27.0
2700+15%
18.0
4400+15%
14.0
temperature +20°C
Rights to change data / design reserved
Configuration
Type of contact
Rated current
Rated voltage / max.breaking voltage AC
Maximum breaking capacity AC
Make current (max. 4 s at duty cycle 10%)
peak inrush current 10 µs / 20 ms
Contact material
Special Load PCB Relay 409 47, 409 67
1 pole 10 A, for high inrush currents,
mono- or bistable
Coil data bistable
1 coil
Nominal voltage
Nominal coil power
Minimum energization time
Max. energization time
6...100 Vdc
0.8...1 W
20 ms
1 min at < 10% duty cycle
Coil versions bistable, 1 coil
Coil
Nominal
Pull-in
Reset
Reset
Coil
Coil
code
voltage
voltage
voltage
voltage
resistance
current
Vdc
Vdc
min Vdc
max Vdc
c
mA
032
12
8.9
-2.5
-3.5
118+10%
102.0
029
24
18.0
-5.0
-7.0
457+10%
53.0
All figures are given for coil without preenergization, at ambient temperature +20°C, duty
cycle 20%
Other coil voltages on request
Insulation
Dielectric strength
coil-contacts
open contact circuit
Clearance / creepage
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage
Tracking resistance of relay base
4000 Vrms
1000 Vrms
8 / 8 mm
C / 250
PTI 250
PCB layout / terminal assignment
Edition: 07/2004
Other data
Flammability class according to UL 94
Ambient temperature
Mechanical life
Max. switching rate at rated- / minimum load
Operate- / release time
Bounce time
Vibration resistance
Shock resistance (destruction)
Category of protection (IEC 61810)
Relay weight
Packaging unit
S0163-CX
V-0
-20...+70 °C
30x106 operations
15 min-1 / 1200 min-1
typ. 10 / 3 ms
typ. 3 ms
20 g (30...300 Hz)
100 g
RT II - flux proof
16 g
25 / 250 pcs.
S0163-BF
Bistable versions:
Indicated contact position during or after coil
energization with reset voltage.
Rights to change data / design reserved
Bottom view on solder pins
Dimensions in mm
Special Load PCB Relay 409 47, 409 67
1 pole 10 A, for high inrush currents,
mono- or bistable
Dimensions
Dimensions in mm
0409 67 002 000
0409 67 003 000
is identical with
is identical with
0409 67 032 001
0409 67 029 001
Rights to change data / design reserved
Edition: 07/2004
S0273-AI