Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s FEATURES PRODUCT OVERVIEW n Choice of 3 input ranges: 10-18V, 18-36V, 36-75V n Models Include 3.3V @ 4.5A or 6A 5V @ 3.5A or 6A 15V @ 1.2A 12V @ 1.4A n Guaranteed efficiencies to 89% n 15-30 Watts in 1" x 2" package n 340kHz synchronous-rectifier topologies n –40 to +60/70°C ambient w/o derating n Fully isolated (1500Vdc); I/O protected n Trim and On/Off Control n UL1950/EN60950 certified n CE mark (75VIN models) The UEP Series DC/DC Converters deliver the most power/current (up to 30W/6Amps) from a 1" x 2" package. And because of their footprint compatibility, they can be used as drop in replacements for their bigger brothers, the standard 2" x 2" and 1.6" x 2" devices, commonly used in the industry. By combining a high-frequency (340kHz), high-efficiency (to 89%), synchronous-rectifier topology with the newest components and time-tested, fully automated, SMT-on-pcb construction, these UEP Models are able to bring you 15-30W in the standard 2" x 1" package from which most competitors can only get 5-10W. All UEP’s deliver their full output power over ambient temperature ranges from –40°C to as high as +70°C (model and input voltage dependent) without heat sinks or supplemental forced-air cooling. Devices derate to +100°C. Output voltages are 3.3, 5, 12 or 15 Volts. Input voltage ranges are 10-18V (“D12” models), 18-36V (“D24” models) or 36-75V (“D48”) models. All models feature input pi filters, input undervoltage and overvoltage lockout, input reverse-polarity protection, output overvoltage protection, output current limiting, and continuous short-circuit protection. Standard features also include on/off control and output-trim. All models are certified to IEC950, UL1950 and EN60950 safety requirements for OPERATIONAL insulation. “D48” models (36‑75V inputs) are CE marked. UEP Series DC/DC’s are packaged in low-cost, light-weight, diallyl phthalate (UL94V-0 rated) plastic packages with standoffs. EMC compliance is achieved via a lownoise design rather than through expensive metal shielding. For full details go to www.murata-ps.com/rohs +INPUT (1) +OUTPUT (4) SWITCH CONTROL ➀ –OUTPUT (5) ➀ –INPUT (2) PWM CONTROLLER OPTO ISOLATION UVLO & OVLO COMPARATORS ON/OFF CONTROL (3) REFERENCE & ERROR AMP TRIM (6) ➀ 3.3V and 5V-output models use the synchronous-rectifier configuration shown above. 12V and 15V-output models employ a standard, diode-rectification architecture. Figure 1. Simplified Schematic Typical topology is shown. www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 1 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Performance Specifications and Ordering Guide ➀ Output Input Load ➂ Vin Nom. (Volts) Range (Volts) Vout (mA) Min. Typ. Package (Case, Pinout) ±0.5% 12 10-18 80/1490 83.5% 84.5% C15, P21 ±0.2% ±0.5% 24 18-36 50/730 85.5% 87.5% C15, P21 100 ±0.2% ±0.5% 48 36-75 35/360 85.5% 87.5% C15, P21 100 ±0.2% ±0.3% 48 36-75 40/470 86% 88% C15, P21 85 100 ±0.2% ±0.5% 12 10-18 120/1760 84% 86% C15, P21 3500 85 100 ±0.2% ±0.5% 24 18-36 65/850 86% 88% C15, P21 5 3500 85 100 ±0.2% ±0.5% 48 36-75 40/430 86% 88% C15, P21 5 6000 85 100 ±0.2% ±0.3% 48 36-75 35/710 88% 91% C15, P21 UEP-12/1400-D12 12 1400 85 100 ±0.2% ±0.5% 12 10-18 60/1650 82.5% 85% C15, P21 UEP-12/1400-D24 12 1400 85 100 ±0.2% ±0.5% 24 18-36 45/800 85% 87% C15, P21 UEP-12/1400-D48 12 1400 85 100 ±0.2% ±0.5% 48 36-75 20/400 85% 87% C15, P21 UEP-15/1200-D12 15 1200 85 100 ±0.2% ±0.5% 12 10-18 60/1760 82.5% 85% C15, P21 UEP-15/1200-D24 15 1200 85 100 ±0.2% ±0.5% 24 18-36 45/860 85% 87% C15, P21 R/N (mVp-p) Regulation (Max.) Model Vout (Volts) Iout (mA) Typ. Max. Line UEP-3.3/4500-D12 3.3 4500 85 100 ±0.2% UEP-3.3/4500-D24 3.3 4500 85 100 UEP-3.3/4500-D48 3.3 4500 85 UEP-3.3/6000-D48 3.3 6000 85 UEP-5/3500-D12 5 3500 UEP-5/3500-D24 5 UEP-5/3500-D48 UEP-5/6000-D48 ➀ Typical at TA = +25°C under nominal line voltage and full-load conditions, unless otherwise noted. ➁ Ripple/Noise (R/N) is tested/specifed over a 20MHz bandwidth. All models are specified with no external input/output capacitors. PART NUMBER STRUCTURE ➂ Load regulation is specified over no load to 100% load conditions for 3.3 and 5Vout models, 25mA to 100% load conditions for 12 and 15 Vout models. ➃ Nominal line voltage, no-load/full-load conditions. MECHANICAL SPECIFICATIONS 2.00 (50.80) U EP - 3.3 / 4500 - D48 N - C Nominal Output Voltage: 3.3, 5, 12 or 15 Volts PLASTIC CASE ROHS-6 Hazardous Substance Compliance Output Configuration: U = Unipolar External Pinout 0.49 (12.45) Case C15 STANDOFF 0.020 (0.51) 0.040 ±0.001 DIA. (1.016 ±0.025) 0.20 MIN (5.08) N Suffix Available for 12Vout and 15Vout Models 1.800 (45.72) 0.10 (2.54) 1 4 2 Input Voltage Range: D12 = 10-18 Volts (12V nominal) D24 = 18-36 Volts (24V nominal) D48 = 36-75 Volts (48V nominal) Maximum Output Current in mA Optional Functions UEP converters are designed such that the 12 and 15Vout models can be configured for either positive logic on/off control (no suffix) or negative logic (“N” suffix). 3.3 and 5Vout models are available with positive logic only (no suffix). No Suffix On/Off Control function (positive polarity) on pin 3 N Efficiency On/Off Control function (negative polarity) on pin 3. (12V and 15V models only.) www.murata-ps.com 1.00 (25.40) 0.400 (10.16) 5 0.600 (15.24) 3 6 0.400 (10.16) 0.800 (20.32) BOTTOM VIEW 0.100 (2.54) 0.10 (2.54) DIMENSIONS ARE IN INCHES (MM) I/O Connections Pin Function P21 1 +Input 2 –Input 3 On/Off Control 4 +Output 5 –Output 6 Trim Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 2 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Performance/Functional Specifications Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀➁ Input Input Voltage Range: D12 Models D24 Models D48 Models Dynamic Characteristics (continued) 10-18 Volts (12V nominal) 18-36 Volts (24V nominal) 36-75 Volts (48V nominal) Overvoltage Shutdown: D12 Models D24 Models D48 Models ➆ 18.5-21 Volts (20V typical) 37-40 Volts (38V typical) 77-81 Volts (78.5V typical) Start-Up Threshold: ➂ D12 Models D24 Models D48 Models 9.3-9.8 Volts (9.6V typical) 16.5-18 Volts (17V typical) 34-36 Volts (35V typical) Undervoltage Shutdown: ➂ D12 Models D24 Models D48 Models 7-8.5 Volts (8V typical) 15.5-17.5 Volts (16.5V typical) 32.5-35.5 Volts (34.5V typical) Input Current: Normal Operating Conditions Standby Mode (Off, OV, UV) See Ordering Guide 5mA Input Filter Type Pi Reverse-Polarity Protection Brief duration, 10A maximum On/Off Control (Optional, Pin 3): ➃ D12, D24, & D48 Models D12N, D24N, & D48N Models On = open or 13V - +VIN, IIN = 50µA max. Off = 0-0.8V, IIN = 1mA max. On = 0-0.5V, IIN = 50µA max. Off = open or 2.4-10V, IIN = 3.7mA max. Output VOUT Accuracy (50% load): ±1.5%, maximum Minimum Loading: ➁ 3.3V/5V Outputs 12V/15V Outputs No load 25mA Ripple/Noise (20MHz BW) ➀ ➄ See Ordering Guide Switching Frequency 6A Models 1.2A-4.5A Models 400kHz (±20kHz) 340kHz (±40kHz) Environmental Operating Temperature (Ambient): Without Derating ➅ With Derating –40 to +60/70°C to +100°C (See Derating Curves) Case Temperature: Maximum Allowable +100°C Storage Temperature –40 to +105°C Physical Dimensions 2" x 1" x 0.51" (51 x 25 x 12.95mm) Shielding None Case Material Diallyl phthalate, (UL94V-0 rated) Pin Material Gold-plated copper alloy with nickel underplate Weight 1.4 ounces (39.7 grams) ➀ All models are specified with no external input/output capacitors. ➁ See Minimum Output Loading Requirements under Technical Notes. ➂ See Technical Notes for details. ➃ The On/Off Control is designed to be driven with open-collector logic or the application of appropriate voltages (referenced to –Input (Pin 2)). Applying a voltage to the On/Off Control pin when no input voltage is applied to the converter may cause permanent damage. See Technical Notes. ➄ Output noise may be further reduced with the addition of external output capacitors. See Technical Notes. ➅ Operating temperature range without derating is model and input-voltage dependent. See Temperature Derating. ➆ UEP-3.3/600-D48 and UEP-5/6000-D48 do not have overvoltage shutdown. See Absolute Maximum Ratings for allowable input voltages. Absolute Maximum Ratings Input Voltage: Continuous: D12 Models D24 Models D48 Models Line/Load Regulation See Ordering Guide Efficiency See Ordering Guide Isolation Voltage: Input-to-Output 1500Vdc minimum Isolation Capacitance 470pF Isolation Resistance 100MW Current Limit Inception: ➂ 6A Models 4.5A Models 3.5A Models 1.4A Models 1.2A Models 7-8 Amps 5.5-7 Amps (6.25 Amps typ.) 5.5-6 Amps (5.25 Amps typ.) 1.9-2.7 Amps (2.3 Amps typ.) 1.5-2.1 Amps (1.8 Amps typ.) Input Reverse-Polarity Protection Short Circuit: ➂ Average Current Hiccup, indefinite 3 Amps maximum Output Current Hiccup. Devices can withstand sustained output short circuits without damage. VOUT Trim Range ➂ ±5% Overvoltage Protection ➂ Zener/transorb clamp, magnetic feedback Case Temperature +100°C Temperature Coefficient ±0.02% per °C.Dynamic Characteristics Storage Temperature –40 to +105°C Lead Temperature (soldering, 10 sec.) +300°C Dynamic Characteristics Transient Response (50-100% load) 300µsec max. to ±1.5% of final value Start-Up Time: ➂ VIN to VOUT On/Off to VOUT 50msec 30msec www.murata-ps.com 22 Volts 44 Volts 88 Volts Transient (100msec): D12 Models D24 Models D48 Models Output Overvoltage Protection: 3.3V Outputs 5V/12V/15V Outputs 22 Volts 44 Volts 88 Volts Current must be <10 Amps. Brief duration only. Fusing recommended. 4.5 Volts, unlimited duration 6.8/15/18 Volts, unlimited duration These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied. Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 3 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s TECHNICAL NOTES 1 Floating Outputs Since these are isolated DC/DC converters, their outputs are “floating.” Designers will usually use the –Output (pin 5) as the ground/return of the load circuit. You can, however, use the +Output (pin 4) as ground/return to effectively reverse the output polarity. 2 3 Minimum Output Loading Requirements 3.3 and 5V models employ a synchronous-rectifier design topology. All models regulate within spec and are stable under no-load conditions. 12/15V models employ a traditional forward, diode-rectification architecture and require 25mA loading to achieve their listed regulation specs. Operation under 25mA load conditions will not damage the 12/15V devices; however they may not meet all listed specifications. Filtering and Noise Reduction All UEP Series DC/DC Converters achieve their rated ripple and noise specifications with no external input/output capacitors. In critical applications, input/output noise may be further reduced by installing external I/O caps. Input capacitors should be selected for bulk capacitance, low ESR and high rms-ripple-current ratings. Output capacitors should be selected for low ESR and appropriate frequency response. All caps should have appropriate voltage ratings and be mounted as close to the converters as possible. VIN Range Fuse Value D12 Models D24 Models D48 Models (1.2-4.5A) D48 Models (6A) 3 Amps 2 Amps 1 Amp 2 Amp Trimming Output Voltages These converters have a trim capability (pin 6) that allows users to adjust the output voltage ±5%. Adjustments to the output voltage can be accomplished via a trim pot, Figure 2, or a single fixed resistor as shown in Figures 3 and 4. A single fixed resistor can increase or decrease the output voltage depending on its connection. Fixed resistors should have an absolute TCR less than 100ppm/°C to minimize sensitivity to changes in temperature. A single resistor connected from the Trim (pin 6) to the +Output (pin 4), see Figure 3, will decrease the output voltage. A resistor connected from the Trim (pin 6) to –Output (pin 5) will increase the output voltage. Trim adjustment greater than 5% can have an adverse effect on the converter's performance and is not recommended. www.murata-ps.com –INPUT ON/OFF CONTROL +OUTPUT TRIM –OUTPUT 4 6 20kΩ 5-22 Turns LOAD 5 Figure 2. Trim Connections Using A Trim Pot 1 +INPUT +OUTPUT 4 RTRIM DOWN 2 3 –INPUT ON/OFF CONTROL TRIM –OUTPUT 6 LOAD 5 Figure 3. Trim Connections To Decrease Output Voltage Using Fixed Resistors 1 The most effective combination of external I/O capacitors will be a function of load and layout conditions. Our Applications Engineers can recommend potential solutions and discuss the possibility of our modifying a given device’s internal filtering to meet your specific requirements. Contact our Applications Engineering Group for additional details. Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of sustained, non-current-limited, input-voltage polarity reversals exists. For DATEL UEP Series DC/DC Converters, you should use slow-blow type fuses with values no greater than the following. +INPUT 2 3 +INPUT –INPUT ON/OFF CONTROL +OUTPUT TRIM 4 6 LOAD RTRIM UP –OUTPUT 5 Figure 4. Trim Connections To Increase Output Voltage Using Fixed Resistors Model UEP-3.3/4500-D12 UEP-3.3/4500-D24 UEP-3.3/4500-D48 UEP-3.3/6000-D48 UEP-5/3500-D12 UEP-5/3500-D24 UEP-5/3500-D48 UEP-5/6000-D48 Trim Equation RTDOWN (kΩ) = RTUP (kΩ) = RTDOWN (kΩ) = RTUP (kΩ) = UEP-12/1400-D12 UEP-12/1400-D24 UEP-12/1400-D48 RTDOWN (kΩ) = UEP-15/1200-D12 UEP-15/1200-D24 UEP-15/1200-D48 RTDOWN (kΩ) = RT UP (kΩ) = RTUP (kΩ) = 2.49(VO – 1.27) 3.3 – VO 3.16 VO – 3.3 –16.9 –16.9 2.49(VO – 2.527) –15 5 – VO 6.292 VO – 5 –15 6.34(VO – 5.714) –49.9 12 – VO 36.23 VO – 12 –49.9 7.87(VO – 7.136) –63.4 15 – VO 56.16 VO – 15 –63.4 Accuracy of adjustment is subject to tolerances of resistor values and factoryadjusted output accuracy. Vo = desired output voltage. Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 4 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Input Overvoltage/Undervoltage Shutdown and Start-Up Threshold Under normal start-up conditions, devices will not begin to regulate until the ramping-up input voltage exceeds the Start-Up Threshold Voltage (35V for "D48" models). Once operating, devices will not turn off until the input voltage drops below the Undervoltage Shutdown limit (34V for "D48" models). Subsequent re-start will not occur until the input is brought back up to the Start-Up Threshold. This built in hysteresis prevents any unstable on/off situations from occurring at a single input voltage. Input voltages exceeding the input overvoltage shutdown specification listed in the Performance/Functional Specifications will cause the device to shutdown. A built-in hysteresis of 0.6 to 1.6 Volts for all models will not allow the converter to restart until the input voltage is sufficiently reduced. The two 6 Amp models do not feature overvoltage shutdown and withstand surges to 100V without shutting down. For custom overvoltage protection, contact DATEL. Input Reverse-Polarity Protection If the input-voltage polarity is accidentally reversed, an internal diode will become forward biased and likely draw excessive current from the power source. If the source is not current limited (<10A) nor the circuit appropriately fused, it could cause permanent damage to the converter. On/Off Control The input-side, remote On/Off Control function (pin 3) can be ordered to operate with either polarity (negative polarity available for 12 and 15 Volt models only). Positive-polarity devices (standard, no part-number suffix) are enabled when pin 3 is left open or is pulled high (+13V to VIN applied with respect to –Input, pin 2, (see Figure 2). Positive-polarity devices are disabled when pin 3 is pulled low (0-0.8V with respect to –Input). Negative-polarity devices are off when pin 3 is open or pulled high (+2.4V to +10V), and on when pin 3 is pulled low (0-0.5V). See Figure 3. 1 +INPUT 200k 13V CIRCUIT 3 ON/OFF CONTROL 2 5V CIRCUIT –INPUT Figure 2. Driving the Positive Polarity On/Off Control Pin www.murata-ps.com 1 +INPUT 3 ON/OFF CONTROL 2 –INPUT Figure 3. Driving the Negative Polarity On/Off Control Pin Dynamic control of the remote on/off function is best accomplished with a mechanical relay or an open-collector/open-drain drive circuit (optically isolated if appropriate). The drive circuit should be able to sink appropriate current (see Performance Specs) when activated and withstand appropriate voltage when deactivated. Applying an external voltage to pin 3 when no input power is applied to the converter can cause permanent damage to the converter. Start-Up Time The VIN to VOUT start-up time is the interval of time where the input voltage crosses the turn-on threshold point, and the fully loaded output voltage enters and remains within its specified accuracy band. Actual measured times will vary with input source impedance, external input/output capacitance, and load. The UEP Series implements a soft start circuit that limits the duty cycle of the PWM controller at power up, thereby limiting the Input Inrush current. The On/Off Control to VOUT start-up time assumes the converter has its nominal input voltage applied but is turned off via the On/Off Control pin. The specification defines the interval between the time at which the converter is turned on and the fully loaded output voltage enters and remains within its specified accuracy band. Similar to the VIN to VOUT start-up, the On/Off Control to VOUT start-up time is also governed by the internal soft start circuitry and external load capacitance. Current Limiting When output increases to 120% to 190% of the rated output current, the DC/DC converter will go into a current limiting mode. In this condition the output voltage will decrease proportionately with increases in output current, thereby maintaining a somewhat constant power dissipation. This is commonly referred to as power limiting. Current limit inception is defined as the point where the full-power output voltage falls below the specified tolerance. See Performance/Functional Specifications. If the load current being drawn from the converter is significant enough, the unit will go into a short circuit condition. See “Short Circuit Condition.” Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 5 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Short Circuit Condition When a converter is in current limit mode the output voltages will drop as the output current demand increases. If the output voltage drops too low, the magnetically coupled primary side voltages will also drop, thereby shutting down the PWM controller. Thermal Shutdown These UEP converters are equipped with Thermal Shutdown Circuitry. If environmental conditions cause the internal temperature of the DC/DC converter rises above the designed operating temperature (typically 118°C case), a precision temperature sensor will power down the unit. When the internal temperature decreases below the threshold of the temperature sensor the unit will self start. Temperature Derating Curves for UEP-3.3/4500 Output Models 17.5 VIN = 18V-27V (D24) VIN = 36V-48V (D48) 15 12.5 Output Power (Watts) Following a time-out period, the PWM will restart, causing the output voltage to begin ramping to its appropriate value. If the short-circuit condition persists, another shutdown cycle will be initiated. This on/off cycling is referred to as "hiccup" mode. The hiccup cycling reduces the average output current, thereby preventing internal temperatures from rising to excessive levels. The UEP is capable of enduring an indefinite short circuit output condition. Typical Performance Curves 10 VIN = 18V-30V (D24) VIN = 36V-60V (D48) 7.5 VIN = 12V (D12) VIN = 18V-36V (D24) 5 VIN = 36V-75V (D48) 2.5 0 Output Overvoltage Protection Output voltages are monitored for an overvoltage condition via magnetic coupling to the primary side. If the output voltage should rise to a level which could be damaging to the load circuitry, the sensing circuitry will power down the PWM controller causing the output voltages to decrease. Following a time-out period the PWM will restart, causing the output voltages to ramp to their appropriate values. If the fault condition persists, and the output voltage again climbs to excessive levels, the overvoltage circuitry will initiate another shutdown cycle. This on/off cycling is referred to as “hiccup” mode. –40 0 40 45 50 55 60 65 70 75 80 85 90 95 100 Ambient Temperature (°C) 5%0$%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT %FFICIENCY 6).6 6).6 6).6 ,OAD#URRENT!MPS www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 6 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Typical Performance Curves Temperature Derating Curves for UEP-3.3/6000-D48 UEP-3.3/4500-D48 Efficiency vs. Line Voltage and Load Current 90 21 85 VIN = 36V 18 80 12 Efficiency (%) Output Power (Watts) 15 VIN = 75V 9 VIN = 48V 75 VIN = 36V 70 65 VIN = 48V 60 6 55 3 0 VIN = 75V 50 45 –40 0 40 45 50 55 60 65 70 75 80 85 90 95 100 0.4 0.91 1.43 90 85 80 Efficiency (%) %FFICIENCY 6).6 6).6 2.96 3.48 3.99 4.5 75 70 VIN = 36V 65 VIN = 48V 60 55 6).6 2.45 UEP-3.3/6000-D48 Efficiency vs. Line Voltage and Load Current 5%0$%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT 1.94 Load Current (Amps) Ambient Temperature (˚C) 45 VIN = 75V 50 1 2 3 4 5 6 Load Current (Amps) ,OAD#URRENT!MPS www.murata-ps.com 7 Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 7 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Typical Performance Curves Temperature Derating Curves for UEP-5/6000-D48 Temperature Derating Curves for UEP-5/3500 Output Models 32 20 VIN = 18V-27V (D24) 17.5 28 VIN = 36V-48V (D48) 24 Output Power (Watts) 15 Output Power (Watts) VIN = 36V-48V 12.5 VIN = 18V-30V (D24) 10 VIN = 36V-60V (D48) 7.5 VIN = 12V (D12) VIN = 18V-36V (D24) 5 20 16 12 VIN = 75V 8 VIN = 36V-75V (D48) 4 2.5 0 0 –40 0 40 45 50 55 60 65 70 75 80 85 90 95 –40 100 0 40 45 50 6).6 6).6 70 75 80 85 90 95 100 6).6 6).6 6).6 65 60 5%0$%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT %FFICIENCY %FFICIENCY 5%0$%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT 55 Ambient Temperature (˚C) Ambient Temperature (°C) 6).6 ,OAD#URRENT!MPS ,OAD#URRENT!MPS www.murata-ps.com 8 Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 8 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Typical Performance Curves Temperature Derating Curves for 12V Output Models UEP-5/3500-D48 Efficiency vs. Line Voltage and Load Current 90 18 85 16 VIN = 18V-27V (D24) 80 14 70 Output Power (Watts) 75 Efficiency (%) VIN = 36V-48V (D48) VIN = 36V 65 VIN = 48V 60 55 VIN = 18V-30V (D24) 10 VIN = 36V-60V (D48) 8 VIN = 12V (D12) 6 VIN = 18V-36V (D24) VIN = 36V-75V (D48) VIN = 75V 50 12 4 45 2 40 0.3 0.7 1.1 1.5 1.9 2.3 2.7 3.1 0 3.5 –40 0 40 45 50 Load Current (Amps) 90 85 65 70 75 80 85 90 95 100 80 %FFICIENCY Efficiency (%) 60 5%0$%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT UEP-5/6000-D48 Efficiency vs. Line Voltage and Load Current 95 VIN = 36V 75 70 VIN = 48V 6).6 6).6 65 VIN = 75V 60 55 55 Ambient Temperature (˚C) 1 2 3 4 5 6 Load Current (Amps) www.murata-ps.com 6).6 ,OAD#URRENT!MPS Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 9 of 11 Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Typical Performance Curves 5%0$%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT %FFICIENCY %FFICIENCY 5%0$%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT 6).6 6).6 6).6 6).6 6).6 6).6 ,OAD#URRENT!MPS ,OAD#URRENT!MPS 5%0$%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT UEP-12/1400-D48 Efficiency vs. Line Voltage and Load Current 90 85 75 70 %FFICIENCY Efficiency (%) 80 VIN = 36V 65 VIN = 48V 60 6).6 6).6 55 VIN = 75V 50 45 0.10 0.26 0.43 0.59 0.75 0.91 1.06 1.24 6).6 1.40 Temperature Derating Curves for 15V Output Models UEP-15/1200-D48 Efficiency vs. Line Voltage and Load Current 20 90 18 VIN = 18V-27V (D24) 85 VIN = 36V-48V (D48) 16 80 Efficiency (%) 14 Output Power (Watts) ,OAD#URRENT!MPS Load Current (Amps) VIN = 18V-30V (D24) 12 VIN = 36V-60V (D48) 10 8 VIN = 12V (D12) 6 VIN = 18V-36V (D24) 75 VIN = 36V 70 65 VIN = 48V 60 VIN = 36V-75V (D48) 4 0 VIN = 75V 55 2 –40 0 40 45 50 55 60 65 70 75 80 85 90 95 100 Ambient Temperature (˚C) www.murata-ps.com 50 0.10 0.24 0.38 0.51 0.65 0.79 0.93 1.06 1.2 Load Current (Amps) Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 10 of 11 1 5 - 3 0 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s Typical Performance Curves Output Ripple and Noise (PARD) Output Ripple and Noise (PARD) (VIN = nominal, 3.3V @ 4.5A, no external capacitors.) (VIN = nominal, 12V @ 1.4A, no external capacitors.) 20mV/div, 20MHz BW 20mV/div, 20MHz BW Output Ripple and Noise (PARD) Output Ripple and Noise (PARD) (VIN = nominal, 5V @ 3.5A, no external capacitors.) (VIN = nominal, 15V @ 1.2A, no external capacitors.) 20mV/div, 20MHz BW 20mV/div, 20MHz BW USA: Tucson (AZ), Tel: (800) 547 2537, email: [email protected] Canada: Toronto, Tel: (866) 740 1232, email: [email protected] UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] Murato Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com ISO 9001 REGISTERED email: [email protected] DS-0502B 2/14/08 Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] Website: www.murata-ps.jp China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] © 2008 Murata Power Solutions, Inc. Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. www.murata-ps.com Technical enquiries email: [email protected], tel: +1 508 339 3000 MDC_UEP Models.A02 Page 11 of 11