MA-COM 4-1462000-1

The Best Relaytion
MT2 Relay
108-98006
Rev. C
EC-JM00-0009-03
ECOC: JM10
1. Apr. 04
MT2 Relay
2 pole telecom/signal relay
Through Hole Type (THT)
Non-polarized. non-latching 1 coil
Features
– Telecom/signal relay (dry circuit, test access, ringing)
– Slim line 20 x 10 mm, 0.795 x 0.393 inch
– Switching current 2 A
– 2 changeover contacts (2 form C / DPDT)
– Bifurcated contacts
– Meets FCC Part 68 and ITU-T K20
Typical applications
– Communications equipment
Linecard application – analog, ISDN, xDSL
PABX
Voice over IP
– Office and business equipment
– Measurement and control equipment
– Consumer electronics
– Set top boxes, HiFi
– Medical equipment
- Automotive Equipment
European Directive conformance:
UL 508
File No. E 111441
IEC 61811-52:02
(QC160504)
Page 2 (9)
MT2 relay product conformance according to:
Directive 2000/53/EC: ELV (End of Life of Vehicles)
Directive 2002/95/EC: ROHS (Restrictions of the
use of certain hazardous substances in electrical and
electronic equipment)
Compliance is evidenced by written declaration from all raw
material suppliers.
Tyco Electronics AXICOM only has responsibility for the proper
processing of these materials.
Confirmation is valid for date codes ≥ 0416
108-98006 Rev. C
MT2 Relay
THT Version
Dimension
THT
mm
L
W
H
T
T1
T2
S
Tw
Mounting hole layout
View onto the component side of the PCB
(top view)
Basic grid 2.54 mm
Terminal assignment
Relay - top view
non-latching 1 coil
release condition
Page 3 (9)
108-98006 Rev. C
20.2 + 0.05/-0.02
10 + 0.05/-0.02
11+0.1/-0.2
3.1 ± 0.3
N/A
7.62 ± 0.15
0.55
0.5
inch
0.795 + 0.002/-0.0008
0.393 + 0.002/-0.0008
0.433 + 0.004/-0.008
0.122 ± 0.011
N/A
0.3 ± 0.005
0.021
0.020
MT2 Relay
Coil Data (values at 23°C)
Nominal
voltage
Unom
Vdc
Operate/set voltage range
Minimum
Maximum
voltage Umin
voltage Umax
Vdc
Vdc
Ordering Information
Release/
reset voltage
Minimum
Coil
power
Vdc
mW
Coil
Resistance
Relay
code
Tyco part
number
Ω / ± 10 %
High sensitive version (150 mW)
non-latching 1 coil
3
4.5
5
6
9
12
24
48
2.1
3.2
3.6
4.3
6.4
8.6
17.1
33.1
8.1
12.2
13.5
16.2
24.3
32.4
64.8
129.6
0.30
0.45
0.50
0.60
0.90
1.20
2.40
4.80
150
150
150
150
150
150
150
150
60
136
168
240
544
968
3872
15468
C 93400
C 93406
C 93401
C 93427
C 93405
C 93402
C 93403
C 93404
1-1462001-2
2-1462000-2
0-1462000-1
5-1462000-6
2-1462000-0
0-1462000-7
1-1462000-3
1-1462000-8
7.0
10.5
11.6
14.0
21.0
28.0
59.9
112.0
0.30
0.45
0.50
0.60
0.90
1.20
2.40
4.80
200
200
200
200
200
200
200
200
45
101
125
180
405
720
2880
11520
C 93414
C 93415
C 93416
C 93428
C 93417
C 93418
C 93419
C 93420
1-1462001-1
3-1462000-0
3-1462000-1
5-1462000-7
3-1462000-6
3-1462000-7
4-1462000-1
4-1462000-5
8.9
9.9
23.6
47.3
54.6
0.45
0.50
1.20
2.40
4.80
300
300
300
300
300
73
90
515
2060
8240
C 93433
C 93434
C 93412
C 93435
C 93436
6-1462000-6
6-1462000-8
2-1462000-6
7-1462000-0
7-1462000-2
8.9
9.9
11.8
17.7
23.6
47.3
94.6
0.45
0.50
0.60
0.90
1.20
2.40
4.80
400
400
400
400
400
400
400
50
63
90
203
360
1440
5760
C 93421
C 93422
C 93429
C 93423
C 93424
C 93425
C 93426
4-1462000-7
4-1462000-8
5-1462000-8
5-1462000-0
5-1462000-1
5-1462000-3
5-1462000-5
6.3
7.0
8.4
16.8
33.6
67.2
0.45
0.5
0.60
1.20
2.40
4.80
550
550
550
550
550
550
36
45
66
280
1050
4100
C 93438
C 93450
C 93437
C 93432
C 93431
C 93430
7-1462000-7
8-1462000-5
7-1462000-6
6-1462000-2
6-1462000-1
5-1462000-9
Sensitive version (200 mW)
non-latching 1 coil
3
4.5
5
6
9
12
24
48
2.0
2.9
3.3
3.9
5.9
7.8
15.6
31.2
Sensitive version (300 mW)
non-latching 1 coil
4.5
5
12
24
48
3.1
3.4
8.25
16.5
32.5
Standard version (400 mW)
non-latching 1 coil
4.5
5
6
9
12
24
48
2.9
3.3
3.9
5.9
7.8
15.6
31.2
Standard version (550 mW)
non-latching 1 coil
4.5
5
6
12
24
48
2.9
3.3
3.9
7.8
15.6
31.2
Page 4 (9)
108-98006 Rev. C
MT2 Relay
Coil operating range
3.2
2.6
2.4
2.2
2.0
1.8
1.6
Unom. nominal coil voltage
1.4
1.2
2.2
2
1.8
1.6
1.2
1
0.8
0.8
Uop. min.
Urel. min.
0.4
Unom. nominal coil voltage
1.4
1.0
0.6
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.6
Coil Voltage [U/Unom]
2.4
200 mW coil
200
mW
2.8
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.8
Coil Voltage [U/Unom]
3
150 mW coil
150
mW
3.0
0.6
Uop. min.
Urel. min.
0.4
0.2
0.2
0.0
-60 -50 -40 -30 -20 -10
0
0
10 20 30 40 50 60 70 80 90 100 110 120
-60 -50 -40 -30 -20 -10
Ambient Temperature [°C]
3.0
2.6
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.2
2.0
1.8
1.6
1.4
Unom. nominal coil voltage
1.2
2.2
2.0
1.8
1.6
1.4
1.2
1.0
1.0
0.8
0.8
0.6
Unom. nominal coil voltage
0.6
Uop. min.
Urel. min.
0.4
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.4
Coil Voltage [U/Unom]
2.4
Coil Voltage [U/Unom]
400 mW coil
400
mW
2.8
2.6
Uop. min.
Urel. min.
0.4
0.2
0.2
0.0
0.0
-60 -50 -40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100 110 120
-60 -50 -40 -30 -20 -10
Ambient Temperature [°C]
3.0
2.6
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.4
2.2
2.0
1.6
1.4
Nominal coil voltage
Umax. =
Upper limit of the operative range of
the coil voltage (limiting voltage) when coils are
continously energized
Uop. min. =
Lower limit of the operative range of
the coil voltage (reliable operate voltage)
Urel. min. =
Lower limit of the operative range of
the coil voltage (reliable release voltage)
1.2
Unom. nominal coil voltage
0.8
0.6
Uop. min.
Urel. min.
0.4
0.2
0.0
-60 -50 -40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100 110 120
Unom =
1.8
1.0
0
Ambient Temperature [°C]
550 mW coil
550
mW
2.8
Coil Voltage [U/Unom]
10 20 30 40 50 60 70 80 90 100 110 120
3.0
300 mW coil
300 mW
2.8
0
Ambient Temperature [°C]
10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [°C]
Page 5 (9)
108-98006 Rev. C
MT2 Relay
Contact Data
Number of contacts and type
Contact assembly
Contact material
Limiting continuous current at max. ambient temperature
Maximum switching current
Maximum swichting voltage
Maximum switching capacity
Thermoelectric potential
Minimum switching voltage
Initial contact resistance / measuring condition: 10 mA / 20 mV
Electrical endurance Contact application 0 (30 mV/ 10 mA)
Cable load open end
Resistive load
150 V / 0.2 A - 30 W
24 V / 1.25 A - 30 W
Mechanical endurance
UL contact ratings
2 changeover contacts
Bifurcated contacts
Silver-nickel, gold-covered
2A
2A
220 Vdc
250 Vac
60 W, 62.5 VA
< 10 mV
100 mV
< 70 mW
min. 5 x 106 operations
min. 2.5 x 106 operations
min. 2.0 x 105 operations
min. 2.0 x 105 operations
typ. 108 operations
220 Vdc / 0.24 A - 60 W
125 Vdc / 0.24 A - 30 W
250 Vac / 0.25 A - 62.5 VA
125 Vac / 0.5 A - 62.5 VA
30 Vdc / 2 A - 60 W
DC Voltage [Vdc]
Max. DC load breaking capacity
DC current [A]
Insulation
Insulation resistance at 500 Vdc
Dielectric test voltage (1 min)
between coil and contacts
between adjacent contact sets
between open contacts
> 109 W
1050 Vrms
750 Vrms
750 Vrms
Surge voltage resistance
according to FCC 68 (10 / 160 ms) and IEC (10 / 700 ms)
between coil and contacts
between adjacent contact sets
between open contacts
Page 6 (9)
1500 V
1500 V
1500 V
108-98006 Rev. C
MT2 Relay
High Frequency Data
Capacitance
between coil and contacts
between adjacent contact sets
between open contacts
max. 4 pF
max. 2 pF
max. 2 pF
RF Characteristics
Isolation at 100 / 900 MHz
Insertion loss at 100 / 900 MHz
V.S.W.R. at 100 / 900 MHz
- 31.8 dB / - 14.2 dB
- 0.02 dB / - 0.97 dB
1.03 / 1.31
General data
Operate time at Unom typ. / max.
Release time without diode in parallel (non-latching), typ. / max.
Release time with diode in parallel (non-latching), typ. / max.
Bounce time at closing contact, typ. / max.
Maximum switching rate without load
Ambient temperature
Thermal resistance
Maximum permissible coil temperature
Vibration resistance (function)
Shock resistance, half sinus, 11 ms
Degree of protection
Needle flame test
Mounting position
Processing information
Weight (mass)
Terminal surface
Resistance to soldering heat
4 ms / 5 ms
1 ms / 3 ms
4 ms / 6 ms
1 ms / 5 ms
50 operations/s
-55° C ... +85° C
< 85 K/W
115° C
10 G
10 to 500 Hz
10 G / 30 G (function)
30 G (damage)
immersion cleanable, IP 67
application time 10 s,
any
Ultrasonic cleaning is not recommended
max. 5 g
SnCu 0.7
260° C / 10 s
All data refers to 23° C unless otherwise specified.
Packing
Dimensions in mm
Tube for THT version - 25 relays per stick, 1’000 relays per box
Page 7 (9)
108-98006 Rev. C
MT2 Relay
IM Relays
4th generation slim line – low profile polarized 2 c/o telecom relay with
bifurcated contacts, available as non latching or latching relay with
1 coil. Nominal voltage range from 1.5... 24 V, coil power consumption
of 140... 200 mW, latching relays with 1 coil 100 mW. The IM relay
is available as through hole and surface mount type (J-Legs and Gull
Wings) and capable to switch loads up to 60 W/62,5 VA. Dielectric
strength fulfills the Bellcore requirements according GR 1089 (2,5 kV
– 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs). The IM relay is
CECC/IECQ approved and certified in accordance with IEC/EN 60950
and UL1950. Dimensions approx. 10 x 6 mm board space and
5.65 mm height.
P2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 or 2 coils. Nominal
voltage range from 3 ... 24 V, coil power consumption 140 mW,
latching relays with 1 coil 70 mW. The P2 Relay is available as through
hole or surface mount type and capable to switch currents up to 5
A. Dielectric strength fulfills the Bellcore requirements according GR
1089 (2,5 kV – 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs).
Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
FX Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 coil. Nominal voltage
range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the
high sensitive version, 140... 300 mW for the standard version, latching
relays with 1 coil 100 mW. The FX2 relay is available as through hole
type and capable to switch loads up to 60 W/62,5 VA. Dielectric
strength fulfills the Bellcore requirements according GR 1089 (2,5 kV
– 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs). The FX2 is CECC/
IECQ approved and certified in accordance with IEC/EN 60950 and
UL1950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm
height.
FT2 / FU2 Relays
3rd generation non polarized, non latching 2 c/o telecom relay with
bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power
consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as
through hole and surface mount type. Dielectric strength fulfills the
Bellcore requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC
part 68 (1,5 kV – 10 / 160 µs). The FT2/FU2 is CECC/IECQ approved
and certified in accordance with IEC/EN 60950 and UL1950.
Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
FP1 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 or 2 coils. Nominal
voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW
for the high sensitive version, 140... 300 mW for the standard version,
latching relays with 1 coil 100 mW.. The FP1 Relay is available as
through hole type and capable to switch loads up to
30 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV – 10 /
160 µs). The FP2 is CECC/IECQ approved. Dimensions approx.
14 x 9 mm board space and 5 mm height.
MT2 / MT4
2nd generation non polarized, non latching 2 c/o and 4 c/o telecom and
signal relay with bifurcated contacts. Nominal voltage range from 4.5 ...
48 V, coil power consumption 150/200/300/400 and
550 mW, and 300 mW (MT4). Dielectric strength fulfills the
requirements according FCC part 68 (1,5 kV – 10 / 160 µs) for both
and the Bellcore requirements according GR 1089 (2,5 kV – 2 / 10 µs)
the MT4 only.
Dimensions MT2 approx. 20 x 10 mm board space and 11 mm height,
MT4 approx. 20 x15 mm board space and 11 mm height.
Page 8 (9)
D2n Relays
2nd generation non polarized 2 c/o relay for telecom and various
other applications. Nominal voltage range from 3 ... 48 V, coil power
consumption from 150 .... 500 mW. The D2n relay is capable to
switch currents up to 3 A. Dielectric strength fulfills the requirements
according FCC part 68 (1,5 kV – 10 / 160 µs). Dimensions approx.
20 x10 mm board space and 11,5 mm height.
P1 Relays
Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for
a wide range of applications, available as non latching or latching relay
with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power
consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay
is available as through hole or surface mount type and capable to
switch currents up to 1 A. Dielectric strength fulfills the requirements
according FCC part 68 (1,5 kV – 10 / 160 µs). Dimensions approx.
13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for
SMT version.
W11 Relays
Low cost, non polarized 1 c/o relay for various applications. Nominal
voltage range from 3 ... 24 V, coil power consumption 450 mW,
sensitive versions 200 mW. The W11 relay is capable to switch
currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx.
15,6 x 10,6 mm board space and 11,5 mm height.
Reed Relays
High sensitive, non polarized relay for telecom and various other
applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal
voltage range from 5 ... 24 V, coil power consumption 50...280 mW
for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays
are available in DIP or SIL housing and capable to switch currents up to
0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric
strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and
5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm
height for SIL version.
Cradle Relays
Extremely reliable and mature relay family of 1st generation for various
signal switching applications. Available as non polarized, polarized
/ latching and relay with AC coil. The benefit is the possibility of
combining various contact sets from 1 up to 6 poles, single and
bifurcated contacts, different contact materials with a coil voltage
range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust
protected and hermetically sealed versions, with plug in or solder
terminals and are capable to switch currents up to 5 A. Forcibly
guided (linked) contact sets optional. Dielectric strength 500 Vrms.
Dimensions from approx. 19 x 24 to 19x35 mm board space and
30 mm height.
Other Relays
We offer a variety of different relay families for maintenance and
replacement purposes. These relays are up to 60 years old now, such
as Card Relay SN (V23030 / V23031 series), Small General Purpose
Relay (V23006 series), Small Polarized Relay (V23063 ... V23067
and V23163 ... V23167 series). Accessories like sockets, hold down
springs, etc. optional.
HF3 Relay
High performance low cost RF relay with excellent RF characteristics.
Available with an impedance of 50 and 75 Ohm. Suitable for frequencies up to 3 GHz. Actually smallest RF relay available combining small
size, excellent RF performance and SMD solderability. Available as non
latching or latching relay with 1 or 2 coils and a nominal coil voltage
range from 3 ... 24 V, coil power consumption 140 mW, latching relays
with 1 coil 70 mW. Dimensions 14.6 x 7.3 x 10 mm.
108-98006 Rev. C
Tyco Electronics AXICOM Ltd.
Seestrasse 295 - P.O. Box 220
CH-8804 Au-Wädenswil / Switzerland
Phone +41 1 782 9111
Fax +41 1 782 9080
E-mail: [email protected]
Tyco Electronics AMP GmbH
Paulsternstrasse 26
D-13629 Berlin / Germany
Phone +49 30 386 38260
Fax +49 30 386 38569
E-mail: [email protected]
Tyco Electronics EC Trutnov s.r.o.
Komenského 821
CZ-541 01 Trutnov / Czech Republic
E-mail: [email protected]
Tyco Electronics Corporation
POB 3608,
Harrisburg, PA 17105, USA
Phone +1 800-522-6752
Page 9 (9)
108-98006 Rev. C