CUI VFM40

rev.
page
1 of 3
date
08/2007
DESCRIPTION: open frame AC/DC power supply
PART NUMBER: VFM40 multiple output series
features
·universal input: 90~264VAC
·2”x4” footprint
·industry-standard pin out
·efficiency at 75% typical
(70% for VFM40-T3512)
·meets UL/cUL, TUV, CE
·Pi input filter
·conductive EMI meets CISPR/FCC
class B
·multiple output
model
number
VFM40-D512
output
voltage
5V(V1)
12V(V2)
VFM40-D524
5V(V1 )
24V(V2 )
VFM40-T5125 5V(V1 )
12V(V2 )
-5V(V3 )
VFM40-T512
5V(V1 )
12V(V2 )
-12V(V3 )
VFM40-T515
5V(V 1)
15V(V2 )
-15V(V3)
VFM40-T52412 5V(V1 )
24V(V2 )
-12V(V3)
VFM40-T5245 5V(V1 )
24V(V2 )
-5V(V3 )
VFM40-T52412-1 5V(V1 )
24V(V2 )
12V(V3 )
VFM40-T3512 3.3V(V1 )
5V(V2 )
12V(V3 )
output current
min.
rated
max.
0.4
3.2
5.0
0.2
2.0
2.5
0.4
3.2
5.0
0.2
1.0
1.5
0.4
3.0
5.0
0.2
2.0
2.5
0
0.3
0.5
0.4
3.0
5.0
0.2
2.0
2.5
0
0.3
0.5
0.4
3.0
5.0
0.2
1.5
2.3
0
0.3
0.5
0.4
3.0
5.0
0.2
1.0
1.5
0
0.3
0.5
0.4
3.0
5.0
0.2
1.0
1.5
0
0.4
0.2
0
0.4
0.2
0
0.3
3.0
1.0
0.3
5.0
2.0
0.3
0.5
5.0
1.5
0.5
7.0
3.5
0.5
ripple 1
(mVp-p)
50
120
50
240
50
120
50
50
120
120
50
150
150
50
240
120
50
240
voltage
accuracy 2
±3%
±4%
±3%
±4%
±3%
±4%
±3%
±3%
±4%
±3%
±3%
±4%
±3%
±3%
±4%
±3%
±3%
±4%
line
reg. 3
±1%
±2%
±1%
±2%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±2%
load
reg. 4
±3%
±5%
±3%
±5%
±3%
±5%
±1%
±3%
±5%
±1%
±3%
±5%
±1%
±3%
±5%
±1%
±3%
±5%
50
50
240
120
50
50
120
±3%
±3%
±4%
±3%
±3%
±4%
±3%
±1%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±3%
±5%
±1%
±3%
±5%
±1%
O/P power
max.
40.0W
efficiency
(typ.)
77%
40.0W
78%
40.5W
75%
42.6W
75%
42.0W
75%
42.6W
75%
40.5W
75%
42.6W
75%
30.0W
70%
NOTES:
1. add a 0.1µF ceramic capacitor and a 10µF E.L. capacitor to output for ripple
and noise measuring @20MHz BW.
2. voltage accuracy is set at full load
3. line regulation is measured from 100VAC to 240VAC with full load.
4. load regulation is measured from 60% to 100% full load and from 60% to 20%
full load (60% ±40% full load).
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
PART NUMBER: VFM40 multiple output series
page
2 of 3
date
08/2007
DESCRIPTION: open frame AC/DC power supply
INPUT
voltage
frequency
inrush current
input current
conducted EMI
isolation
leakage current
90-264VAC; 120-370VDC
47 to 440Hz
50A max. @ 264VAC
1A max. (RMS) @ 115VAC
CISPR/FCC Class B
input to output = 4,242VDC
0.5mA max.
OUTPUT
maximum power for convection cooling
30 VFM forced air
hold up time
short circuit / overload protection
over voltage protection
adjustment range
40W (VFM40-T3512, 30W)
50W (VFM40-T3512, 40W)
20mS typ. @ 115VAC
auto recovery (all outputs)
3.6-4.6V/5.7-6.7V on V1 (3.3V/5V)
120%-140% on V2(12V/15V/24V)
10% typ.
ENVIRONMENTAL CHARACTERISTICS
operating temperature
storage temperature
0°C-50°C
-20°C-85°C
MECHANICAL OUTLINE
dimensions
4x2x1.2 inches
(101.6x50.8x30.48 mm 3)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
page
3 of 3
date
08/2007
DESCRIPTION: open frame AC/DC power supply
PART NUMBER: VFM40 multiple output series
DIMENSIONS (mm)
DERATING CURVE
VFM40D-01, 40D-02, 40T-01, 40T-02, 40T-03, 40T-04, 40T-05, 40T-06
VFM40T-07
50
40
40
30
30
20
20LFM(Natural Convection)
100LFM
20
10
20LFM(Natural Convection)
100LFM
10
0
0
0
10
20
30
40
Ambient Temperature(˚C)
50
60
70
0
10
20
30
40
Ambient Temperature(˚C)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
50
60
70