OBSOLETE PRODUCT VKA60xSC 60 Wat Watt tt Single OutputModel Half Brick Brrickk DC/DC Converter Contact Factory for Replacement RoHS Compliant 18-36 V & 33 - 75V Input Range High Efficiency: 87% Typical at 5V 100MS Transient Response 50100% Load Step 420 kHz Fixed-Frequency Operation Remote Sense The VKA60xSC Series DC/DC converters present an economical and practical solution for distributed power system architectures which require high power density and efficiency while maintaining system modularity and upgradeability. With the ability to operate over a wide input voltage range of 18 to 36 and 33 to 75 volts, these modules are ideal for use in battery backup applications common in todays’ telecommunication and electronic data processing applications. The output is fully isolated from the input, allowing for a variety of polarity and grounding configurations. The VKA60xSC’s proprietary control circuitry responds to 50-100% load steps in 100MSeconds to within 1% nominal Vout. Operation to +100oC Baseplate Temperature Primary Remote On/Off, Choice of Pos/Neg Logic Adjustable Output Voltage Continuout Short-Circuit Protection Thermal Shutdown Case Ground Pin The patented fixed frequency architecture combined with surface mount technology results in a compact, efficient and reliable solution to DC/ DC conversion requirements. Safety per UL1950, EN 60950 and CSA 22.2 #234. PRODUCT SELECTION CHART MODEL INPUT VOLTAGE VKA60LS03C VKA60LS05C VKA60LS12C VKA60LS15C VKA60LS24C VKA60MS03C VKA60MS05C VKA60MS12C VKA60MS15C VKA60MS24C 24VDC (18-36) 48VDC (33-75) VOUT (VDC) IOUT (A) 3.3V 5.0V 12.0V 15.0V 24.0V 3.3V 5.0V 12.0V 15.0V 24.0V 12.0 12.0 5.0 4.0 2.5 12.0 12.0 5.0 4.0 2.5 EFFICIENCY MIN 80 85 87 88 89 81 86 88 89 89 TYP 81 86 88 89 90 82 87 89 90 90 THROUGH-HOLE SOLDERING INFORMATION These devices are intended for wave soldering or manual soldering. They are not intended to be subject to surface mount processes under any circumstances. The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this time and temperature range, the integrity of the device’s plastic body will not be compromised and internal temperatures within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering. For full details go to www.murata-ps.com/rohs www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKA60xSC.B01 Page 1 of 4 VKA60xSC SPECIFICATIONS, ALL MODELS 60 Watt Single Output Half Brick DC/DC Converter Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. OUTPUT INPUT PARAMETER INPUT Voltage Range VKA60LS VKA60MS Maximum Input Current VKA60LS VKA60MS Reflected Ripple Current Input Ripple Rejection No Load Input Current LS/MS VIN = 16VDC VIN = 27VDC Peak - Peak DC to 1KHz Power Dissipation LS/MS No Load Standby, Primary On/Off Disabled LS/MS Inrush Charge VIN = VINmax. VKA60LS VKA60MS Quiescent Operating Current Primary On/Off Disabled PARAMETER CONDITIONS OUTPUT Rated Power Set point Accuracy Line Regulation High Line to Low Line Load Regulation No Load to Rated Load Output Temperature Drift Output Ripple, p-p DC to 20MHz BW Output Current Limit Inception Output Short-Circuit Current (2) test Output Overvoltage Limit Transient Response 50 to 100% Load Step Peak Deviation di/dt = 1.0A/MSec Settling Time VOUT, 1% of Nominal Output PARAMETER GENERAL CONDITIONS ISOLATION Input to Output Input to Baseplate Output to Baseplate Resistance Capacitance Leakage Current GENERAL Efficiency, Line, Load, Temp. (3) Switching Frequency Remote Sense Compensation Output Voltage Adjust Range Remote On/Off Control Inputs Primary Sink Current-Logic Low Vlow Vhigh Turn-on Time Weight TEMPERATURE Operation/Specification Storage Shutdown Temperature Thermal Impedance, case-ambient Lead Solder Temperature MIN TYP MAX UNITS 18 33 24 48 36 75 VDC VDC 4.4 2.6 20 60 50/100 A A mA dB mA 3.6/4.8 0.18/0.4 W W 50 MIN 8 TYP 0 0.02 0.2 ±.02 1% 130% 120% 125% 0.520 0.360 mC mC 12 MAX mA UNITS 60 1 0.05 0.5 W % % % %/°C VOUT, Nom lOUT, Nom lOUT, Nom V 150% 150% 135% 2% 100 CONDITIONS MIN Peak Test for 2 Seconds 1500 1500 500 10 TYP VOUT, Nom MSec MAX VDC VDC VDC M7 pF MA, rms 2000 180 VISO = 240VAC, 60Hz 400 12V & higher(4) 420 UNITS 440 0.5 KHz V VOUT, Nom 1.0 0.4 Open Collector 12.5 85 (3.0) mA V -50% / +25% Open Collector/Drain Within 1% of Rated Output Case Temperature Case Temperature Case Temperature 10.0 -40 -55 +100 +25 +25 +100 +125 +115 7.1 10 Seconds max +300 mSec g (oz.) °C °C °C °C/W °C NOTES: (1) See Typical Performance Curves, page 3 (2) Continuous Mode (3) See graphs for Efficiency vs. Output Load, VIN, TCASE (4) 3.3V Models Limited in Trim Down Range (5) Consult Factory for Details www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKA60xSC.B01 Page 2 of 4 VKA60xSC TYPICAL PERFORMANCE CURVES TCASE = +40°C nominal input voltage unless otherwise specified. 60 Watt Single Output Half Brick DC/DC Converter ORDERING INFORMATION VKA60 xSzz - C Device Family Indicates 50 Watt Regulated Unit Model Number Selected from Table of Electrical Characteristics Where: x = Input Voltage (L = 24VDC; M = 48VDC) zz = Output Voltage (03=3.3V, 05=5V, etc.) Lead Length 0.200” - No Number 0.145” - (6) 0.110” - (8) Remote On-Off Logic: Positive - No Number Negative - (1) RoHS Compliant www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKA60xSC.B01 Page 3 of 4 VKA60xSC 60 Watt Single Output Half Brick DC/DC Converter MECHANICAL NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: ± 0.005” 0.530 MAX [13.46] MECHANICAL TOLERANCE: ± 0.015” 0.20 [5.1] .040 [1.02] DIA. 7 PLACES .081 [2.06] DIA. 2 PLACES 0.20 [5.1] 0.50 [12.7] Marked with: specific modeL ordered, date code, job code. MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability. .400 [10.16] 0.40 [10.16] 2.000 [50.80] 0.700 [17.78] VKA60xSC 1.000 [25.40] 1.000 [25.40] 2.40 [61.0] MAX 1.400 [35.56] 1.400 [35.56] MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES MAX. TORQUE, 8 IN/LBS 1.900 [48.26] 0.19 [4.8] 2.28 [57.91] MAX OUTPUT ADJUST VOLTAGE OVP NOTE This feature allows the user to accurately adjust the module’s output voltage set point to a specified level. This is achieved by connecting a resistor or potentiometer from the TRIM terminal to either the +Vout terminal (for increased Vout) or the -Vout terminal (for decreased Vout). The formulae below describe the trim resistor value to obtain a Vout change of $%. VO is output voltage prior to adjustment (3.3V, 5V, 12V, 15V, or 24V). Radj - up = ( Radj - down = Vo(100 + $%) _ (100 + 2$%) 1.225$% $% (100 $-%2) Special attention should be given to the peak voltage deviation during a dynamic load step when trimming the output above the original set point to avoid tripping the overvoltage protection circuit. Should an OVP condition occur, the converter will go into a latch condition and must be externally reset before it will return to normal operation. )7 7 USA: Tucson (Az), Tel: (800) 547 2537, email: [email protected] Canada: Toronto, Tel: (866) 740 1232, email: [email protected] Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] www.murata-ps.com email: [email protected] ISO 9001 REGISTERED Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] Website: www.murata-ps.jp China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] 07/28/08 Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKA60xSC.B01 Page 4 of 4