CPI VTC-6368L4

2.25 kW Peak, 1.2 kW Avg Helix TWT Series, 5.850
to 6.725 GHz, periodic-permanent, magnet focused,
coaxial input, waveguide output, forced-air cooled.
Custom configurations are also available. These variations in the performance and configuration include:
mechanical configuration, electrical and RF connections, and dual-stage depressed collector.
Features
•2.25 kW Peak, 1200 W Avg.
•5.850 - 6.725 GHz
• PPM Focusing
• Coaxial Input
• Waveguide Output
•Any Mounting Position
•Weight: 25 lbs. max
•Forced-Air Cooled
model
VTC-6368L4
VTC--6368L5
VTC-6368L6
Frequency
(GHz)
5.85 - 6.65
5.75 - 6.75
5.85 - 6.725
Power output
peak 2.25 kW 2.25 kW
2.25 kW power output
avg.
1.20 kW
1.20 kW
1.20 kW
TYPICAL OPERATING PARAMeters
MAXIMUMMINIMUM
Heater Voltage:6.6
6.0
Heater Surge Current:
5.0
---
Helix Voltage:
15.3
14.4
Helix Current:
20
---
Collector Voltage 1:---
---
Collector Current 1:
500
---
Cathode Current:
---
---
Collector Voltage 2:
---
---
Collector Current 2:
650
---
Cathode Warm-up Time:---
3.0 Drive Power:
---
---
Collector Temp:
150
---
Load VSWR:
1.7:1
---
Air Flow:
495
---
TYPICALUNITS
---Vdc
--- A
--- kVdc
--- mAdc
0.65% Ew kVdc
--- mAdc
--- mAdc
0.13% Ew kVdc
--- mAdc
---Minutes
--- mW
--- °C
---VSWR
--- lb/hr
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, 607 Hansen Way, Palo Alto, CA 94303
telephone: 1(800) 414-8823. fax : (650) 856-0705 | email : [email protected]
CPI 05/10
CPI
k W peak, 1.2 k W avg C-band helix twt series
CPI 2.25
| 4CW50,000J
2.25 kW Peak, 1.2 kW Avg C-Band Helix TWT Series