600 W, CW Helix TWT Series, 13.75 GHz to 14.50 GHz, Periodic-Permanent, Magnet Focused, Coaxial Input, Waveguide Output, and Forced-Air Cooled. Custom configurations are also available. These variations in the performance and configuration include: mechanical configuration, electrical and RF connections, & dual stage depressed collector. Model Number Frequency (GHz) Power Output (Min.) VTU-6397C7 VTU-6397M5 VTU-6397C2 VTU-6396M5 VTU-6396M7 VTU-6396C1 VTU-6396M8 VTU-6396M6 13.75 – 14.5 12.75 – 14.5 13.75 – 14.5 12.75 – 14.5 13.75 – 14.8 13.75 – 14.5 13.75 – 14.25 15.20 – 17.2 750 W 700 W 700 W 600 W 600 W 600 W 600 W 500 W Operating Parameters Features • • • • • • • • 600 Watts 13.75 GHz – 14.50 GHz PPM Focusing Coaxial Input Waveguide Output Any Mounting Position Weight: 21 lbs. max Forced-Air Cooled Heater Voltage Heater Surge Current Helix Voltage Collector Voltage Cathode Current Helix Current Parameters: Ef If Ew Eb Ik Iw Units: Maximum: Minimum: Typical: V 6.6 6.0 A 5 --- kVdc 12.8 11.4 kVdc 7.0 5.7 mAdc 470 --- mAdc 18 --- Drive Power Pd mW 30 --- Cathode WarmUp Time tk minutes --3 Load VSWR Collector Thermostat Temp. Air Flow 2.0:1 --- °C 150 --- Ib/hr --360 Parameters: Units: Maximum: Minimum: Typical: The values listed above represent specified limits for the product and are subject to change. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For additional information on CPI MPP products contact: CPI MPP, Helix TWT Operation - 811 Hansen Way, Palo Alto, CA 94303-0750 Phone: 650-846-3900, Fax: 650-494-8779, Email: [email protected], www.cpii.com/mpp