MA-COM WOUVT

Voltage Sensitive Relays
WILMAR™ Protective Relays – WOUVT Series, Over/Undervoltage
Function: 27/59
• ANSI/IEEE C37.90-1978
TERMINAL STRIP
#6 - 32 SCREWS
Voltage sensitive relays are available for both AC
and DC applications for overvoltage and undervoltage
protection. Combination over/undervoltage relays
provide band-pass capabilities. AC relays are either
single or three-phase type. Three phase relays are
designed to sense the average of the three phases.
Voltage trip points are screwdriver adjustable, and
operation is time-delayed so that momentary voltage transients will not cause nuisance tripping.
3.0
Operation:
3
The relay will energize at normal voltage condition.
The normally closed contact (Form B) will open and
the normally open (Form A) will close. The relay will
de-energize after time delay when over or undervoltage
condition is reached.
1 /2
1 /8
4
5 /8
4
3
1 /2
1 /4
4
11 / 64 " DIA.
4 MTG. HOLES
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
PRODUCT SPECIFICATIONS
Part Number
WOUVT
Nominal Voltage ...............................
120 VAC to 575 VAC
Phase ................................................
Single or Three
Line Frequency .................................
50-400 Hz
Type of Sensing ...............................
Average of all three phases
Undervoltage Trip ............................
70-100% of nominal voltage, screwdriver adjustable
Overvoltage Trip ...............................
100-125% of nominal voltage, screwdriver adjustable
Drop-out Time Delay ........................
0.5 to 20 seconds, screwdriver adjustable
Pick-up to Drop-out Differential ......
2% maximum
Output Contacts ...............................
One set N.O., One set N.C.
Contact Ratings ................................
5 amp resistive at 120 VAC or 28 VDC
Operating Temperature Range ........
-40°C to +70°C
Power Consumption ........................
4 VA maximum
Notes:
1. Remove black screw for access to the voltage trip and time delay adjustment potentiometer.
2. Clockwise rotation of the voltage adjustment potentiometer will raise the voltage trip point.
3. Clockwise rotation of the time adjustment potentiometer will increase the drop-out time delay.
24
PART NUMBER SELECTION
Sample Part No.
WOUVT -1-120AC
Type:
WOUVT - Over/Undervoltage
No. Phases
1 = Single
3 = Three (line to line)
Line Voltage VAC
400
115
416
120
440
200
460
208
480
220
525
230
575
240
380
Options:
Blank - Standard
A = 2 Form A Contacts
B = 2 Form B Contacts
H = 125 VDC Contacts
P = Transient Protection
Option "H" provides for contacts rating of 3 amps @
125VDC.
Option "P" provides additional transient protection which
complies with the requirements of ANSI/IEEE C37.901978
Consult factory for additional models.
Tyco Electronics / www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International)