ASM-SENSOR WS17KT-1500-PMU-L05

Model WS17KT
with analog or SSI output
Compact sensor for medium ranges
· Protection class IP64
· Measurement ranges:
0 ... 1500 mm to 0 ... 15000 mm
· Analog output 0 … 10 V, 4 … 20 mA, potentiometer
or A/D converted synchronous serial output (SSI)
Outputs
Specifications
Resolution
Material
Sensing Device
Connector
Linearity
Protection class
Weight
Environmental
EMC
Temperature
Order Code WS17KT
Analog or SSI
Potentiometer: 1 kW
Voltage: 0...10 V
Current: 4...20 mA, 2 or 3 wire
Voltage and current output, adjustable
A/D converted synchronous serial max. 16 bit (SSI)
Essentially inifinite / ADSI16: max. 16 bit full scale
Aluminium and stainless steel
Cable: stainless steel
Precision potentiometer
Male socket 8 pin (M12 or DIN 45326)
Up to ±0.05 % full scale
IP64
See table next page
Refer to output specification
Refer to output specification
WS17KT
Model Name
Measurement Range (in mm)
1500 / 2000 / 2500 / 3000 / 4000 / 5000 / 6250 / 10000 / 12500 / 15000
Outputs (see pages 57 ff.)
R1K = Potentiometer 1 kW (other values on request)
10V = with 0 ... 10 V signal conditioner
420A = with 4 ... 20 mA signal conditioner (2 wire)
420T = with 4 ... 20 mA signal conditioner (3 wire)
PMU = with 0...10 V/4 … 20 mA signal conditioner, adjustable
ADSI = with A/D converted synchronous serial output 16 bit (option: 12, 14 bit)
Linearity
L10 = ±0.10 %
option:
L05 = ±0,05 %
L25 = ±0.25 %
Cable fixing
M4
= M4 cable fixing
SB0 = Cable clip
Connection
M12 = 8 pin socket M12
D8
= 8 pin socket DIN 45326
Order Code Mating Connector (see accessories p. 82) D8: CONN-DIN-8F-W M12: CONN-M12-8F-G
Order Example: WS17KT - 2500 - 10V - L10 - M4 - M12
16
CAT-WS-E-05
www.asm-sensor.com
ASM
Model WS17KT
with analog or SSI output
Cable Forces and
Weights
typical at 20 °C
Range
[mm]
Weight (approx.)
[kg]
1500
2000
2500
3000
4000
5000
6250
10000
12500
15000
1.4
1.4
1.5
2.9
2.9
5.3
5.5
6.0
6.0
6.0
Maximum pull-out force
[N]
11.0
8.5
5.5
14.5
12.7
13.0
10.2
16.5
16.5
16.5
Minimum pull-in force
[N]
6.2
4.8
3.5
10.3
9.1
9.3
7.3
9.1
9.1
9.1
Outline drawing
WS17KT-1500 /
2000 / 2500
Dimensions informative only.
For guaranteed dimensions consult factory
Dimensions (mm)
ASM
Range
A
1500
2000
2500
17.5
9.5
2.5
www.asm-sensor.com
CAT-WS-E-05
17
Model WS17KT
with analog or SSI output
Outline drawing
WS17KT-3000 / 4000
Dimensions
[mm]
Range
A
3000
105
4000
120
Dimensions informative only.
For guaranteed dimensions consult factory
Outline drawing
WS17KT-5000 / 6250
Dimensions
[mm]
18
CAT-WS-E-05
www.asm-sensor.com
Range
A
5000
178
6250
198
ASM
Model WS17KT
with analog or SSI output
Outline drawing
WS17KT-10000 /
12500 / 15000
Dimensions informative only.
For guaranteed dimensions consult factory
ASM
www.asm-sensor.com
CAT-WS-E-05
19
Output Specifications
R1K and 10V for WS position sensors
Voltage divider R1K
Potentiometer
Excitation Voltage
32 VDC max. at 1 kW (input power 1 W max.)
Potentiometer Impedance
1 kW ±10%
±25 x 10-6/ °C full scale
Depends on measurement range, individual
sensitivity of sensor specified on label
Approx. 3% ... 97% of full range
-20 ... +85 °C
Thermal coefficient
Sensitivity
Voltage Divider Utilization Range
Operating Temperature
Signal diagram
+ Vin
Note: The potentiometer must be connected
as a voltage divider. The input impedance of
the following processing circuit should be 10
MW min.
+ Vout
GND
Signal conditioner 10V
Voltage output
Excitation Voltage
Excitation Current
Output Voltage
Output Current
Output Load
+18 ... +27 V DC non stabilized
20 mA max.
0 ... +10 V DC
2 mA max.
> 5 kW
±50 x 10-6 / °C full scale
Reverse polarity, short circuit
0,5 mVRMS
-20 ... +85 °C
According to EN 61326:2004
Stability (Temperature)
Protection
Output Noise
Operating Temperature
EMC
Excitation +
Signal diagram
10V
Excitation GND
Signal +
0...10 V
Signal GND
Signal Wiring
Output signals
R1K
+ Vin
GND
+ Vout
Connection
Mating Connector
10V
Excitation +
Excitation GND
Signal +
Signal GND
Connector
pin no.
White
Brown
Green
Yellow
1
2
3
4
View to solder
terminals
CONN-DIN-8F-W
ASM
Cable color
www.asm-sensor.com
CONN-M12-8F-G
CAT-WS-E-05
57
Output Specifications
420A and 420T for WS position sensors
Excitation Voltage
Signal conditioner
420A
Current output (2 wire)
+12 ... 27 VDC non stabilized, measured at the
sensor terminals
35 mA max.
4 ... 20 mA equivalent to 0 ... 100% range
±100 x 10-6 / °C full scale
Reverse polarity, short circuit
0.5 mVRMS
-20 ... +85 °C
According to EN 61326:2004
Excitation Current
Output Current
Stability (Temperature)
Protection
Output Noise
Operating Temperature
EMC
Signal +
Signal Diagram
420A
4...20 mA
Signal Conditioner
420T
Current output (3 wire)
Signal –
Excitation Voltage
Excitation Current
Load Resistor
+18...+27 V DC non stabilized
40 mA max.
350 W max.
4 ... 20 mA equivalent to 0 ... 100% range
±50 x 10-6 / °C full scale
Reverse polarity, short circuit
0.5 mVRMS
-20 ... +85 °C
According to EN 61326:2004
Output Current
Stability (Temperature)
Protection
Output Noise
Operating Temperature
EMC
Signal diagram
Excitation +
420T
Signal +
4...20 mA
Signal Wiring
Output signals
420A
Signal +
Signal –
Connection
Mating Connector
Excitation GND
420T
Excitation +
Excitation GND
Signal +
CAT-WS-E-05
Connector
pin no.
White
Brown
Green
1
2
3
View to solder
terminals
CONN-DIN-8F-W
58
Cable color
www.asm-sensor.com
CONN-M12-8F-G
ASM
Output Specification
PMU for WS position sensors
Signal Conditioner
PMU, adjustable
Voltage output and
current output (3 wire)
Excitation voltage
Excitation current
Voltage output
Output current
Output load
Current output
Load resistor
+18 ... 27 V DC
50 mA max.
0 ... 10 V
10 mA max.
1 kW min.
4 ... 20 mA (3 wire)
500 W max.
Adjustment
Activation of offset and gain adjust
Scalable range
Stability (Temperature)
Protection
Output noise
Operating temperature
EMC
Connect with excitation GND (0 V)
90 % max. full scale
±50 x 10-6 / °C full scale
Reverse polarity, short circuit
1 mVeff
-20 ... +85 °C
According to EN 61326:2004
Signal diagram
Excitation +
Excitation GND
Signal 0...10 V +
PMU
Signal 0...10 V GND
Signal 4...20 mA +
Signal 4...20 mA GND
Output signals
Signal wiring
Connector pin no.
Excitation +
Excitation GND
Signal 0...10 V +
Signal 0...10 V GND
Signal 4...20 mA +
Signal 4...20 mA GND
Offset
Gain
1
2
3
4
5
6
7
8
Connection
Mating Connector
View to solder
terminals
CONN-DIN-8F-W
ASM
www.asm-sensor.com
CONN-M12-8F-G
CAT-WS-E-05
59
Output Specification
ADSI16 for WS position sensors
·
·
·
·
Description
Resolution 16 bit, data transmission synchronous serial/SSI
Optional available with 12 bit (ADSI) or 14 bit (ADSI14) resolution
No loss of data at power-down
Easy to connect to PLC’s with SSI input circuit
The sensing device of the ADSI is a precision potentiometer. The position information is
given by an analog/digital converter output serialized as a data word. Data transmission
takes place by means of the signals CLOCK and DATA. The processing unit (PLC, Microcomputer) sends pulse sequences which clock the data transmission with the required
transfer rate. With the first falling edge of a pulse sequence the position of the sensor is
recorded and stored. The following rising edges control the bit-by-bit A/D conversion,
encoding and output of the data word. After a delay time the next new position information
will be transmitted.
Data Format
(Train of 26 Pulses)
Signal Conditioner
ADSI
A/D converted
synchronous serial
Output
Excitation voltage
Excitation current
Clock frequency
Code
Delay between pulse trains
Resolution
EIA RS-422, RS-485, short-circuit proof
11 ... 27 VDC
200 mA max.
70 ... 500 kHz
Gray code, continuous progression
T=30 µs min.
16 bit (65536 counts) full scale; optional 12 bit
or 14 bit
±50 x 10-6 / °C full scale
-20 ... +85 °C
According to EN 61326:2004
Stability (temperature)
Operation temperature
EMC
Recommended
Processing
Input Circuit
Sensor circuit
Cable
Subsequent circuit
GND (0V)
Transmission rate
Cable length
Baud rate
< 50 m
< 100 m
< 300 kHz
< 100 kHz
Signal names
Signal Wiring
64
CAT-WS-E-05
Connector pin no.
Excitation +
Excitation GND (0V)
CLOCK
CLOCK
DATA
DATA
Screen
1
2
3
4
5
6
not connected
www.asm-sensor.com
Note:
Extension of the cable length will reduce the
maximum transmission rate. The signals
CLOCK/CLOCK and DATA/DATA must be
connected in a twisted pair cable, shielded
per pair and common.
Mating connector: view to solder terminals
CONN-DIN-8F-W
CONN-M12-8F-G
ASM