XICOR X24C00S-2.7

APPLICATION NOTES
A V A I L A B L E
X24C00
AN4 • AN12 • AN22 • AN26 • AN32
X24C00
128 Bit
16 x 8 Bit
Serial E2PROM
FEATURES
DESCRIPTION
•
•
•
The X24C00 is a CMOS 128 bit serial E2PROM, internally organized as 16 x 8. The X24C00 features a serial
interface and software protocol allowing operation on a
simple two wire bus.
•
•
•
•
•
•
•
2.7V to 5.5V Power Supply
128 Bit Serial E2PROM
Low Power CMOS
—Active Current Less Than 3mA
—Standby Current Less Than 50µA
Internally Organized 16 x 8
2 Wire Serial Interface
—Bidirectional Data Transfer Protocol
Byte Mode Write
Self Timed Write Cycle
—Typical Write Cycle Time of 5ms
Push/Pull Output
High Reliability
—Endurance: 100,000 Cycles
—Data Retention: 100 Years
Available Packages
—8-Lead MSOP
—8-Lead PDIP
—8-Lead SOIC
Xicor E2PROMs are designed and tested for applications requiring extended endurance. Inherent data retention is greater than 100 years.
The X24C00 is fabricated with Xicor’s Advanced CMOS
Floating Gate technology.
FUNCTIONAL DIAGRAM
PIN CONFIGURATION
MSOP/DIP/SOIC
SCL
SDA
CONTROL
LOGIC
INPUT/
OUTPUT
BUFFER
COMMAND/ADDRESS
REGISTER
NC
NC
1
NC
3
VSS
4
2
X24C00
8
VCC
7
NC
6
SCL
5
SDA
SHIFT REGISTER
3836 FHD F02.1
MEMORY ARRAY
3836 FHD F01
© Xicor, Inc. 1991, 1995, 1996 Patents Pending
3836-1.5 6/10/96 T2/C1/D0 NS
1
Characteristics subject to change without notice
X24C00
PIN DESCRIPTIONS
Clock and Data Conventions
Serial Clock (SCL)
Data states on the SDA line can change only during SCL
LOW. SDA state changes during SCL HIGH are reserved for indicating start and stop conditions. Refer to
Figures 1 and 2.
The SCL input is used to clock all data into and out of the
device.
Serial Data (SDA)
Start Condition
SDA is a bidirectional pin used to transfer data into and
out of the device. It is a push/pull output and does not
require the use of a pull-up resistor.
All commands are preceded by the start condition,
which is a HIGH to LOW transition of SDA when SCL is
HIGH. The X24C00 continuously monitors the SDA and
SCL lines for the start condition and will not respond to
any command until this condition has been met.
PIN NAMES
Symbol
NC
VSS
VCC
SDA
SCL
Description
No Connect
Ground
Supply Voltage
Serial Data
Serial Clock
A start may be issued to terminate the input of a control
word or the input of data to be written. This will reset the
device and leave it ready to begin a new read or write
command. Because of the push/pull output, a start
cannot be generated while the part is outputting data.
Starts are also inhibited while a write is in progress.
Stop Condition
3836 PGM T01
The stop condition is a LOW to HIGH transition of SDA
when SCL is HIGH. The stop condition is used to reset
the device during a command or data input sequence
and will leave the device in the standby mode. As with
starts, stops are inhibited when outputting data and
while a write is in progress.
DEVICE OPERATION
The X24C00 supports a bidirectional bus oriented protocol. The protocol defines any device that sends data
onto the bus as a transmitter and the receiving device as
the receiver. The device controlling the transfer is a
master and the device being controlled is the slave. The
master will always initiate data transfers and provide the
clock for both transmit and receive operations. Therefore, the X24C00 will be considered a slave in all
applications.
Write Operation
The byte write operation is initiated with a start condition.
The start condition is followed by an eight bit control byte
which consists of a two bit write command (0,1), four
address bits, and two “don’t care” bits (Figure 3).
2
X24C00
Figure 1. Data Validity
SCL
SDA
DATA STABLE
DATA
CHANGE
3836 FHD F03
Figure 2. Definition of Start and Stop Conditions
SCL
SDA
START CONDITION
STOP CONDITION
3836 FHD F04
Figure 3. Control Byte
START
C1 C2 A3
A2
A1
A0 XX XX
3836 FHD F05
3
X24C00
After receipt of the control byte, the X24C00 will enter
the write mode and await the data to be written. This data
is shifted into the device on the next eight SCL clocks.
Once eight clocks have been received, the data in the
shift register will be written into the memory array. While
the write is in progress the X24C00 will not respond to
any inputs. At any time prior to clocking in the last data
bit, a stop command or a new start command will
terminate the operation. If a start command is given, the
X24C00 will reset all counters and will prepare to clock
in the next control byte. If a stop command is given, the
X24C00 will reset all counters and await the next start
command.
Read Operation
The byte read operation is initiated with a start condition.
The start condition is followed by an eight-bit control byte
which consists of a two-bit read command (1,0), four
address bits, and two “don’t care” bits. After receipt of
the control byte the X24C00 will enter the read mode and
transfer data into the shift register from the array. This
data is shifted out of the device on the next eight SCL
clocks. At the end of the read, all counters are reset and
the X24C00 will enter the standby mode. As with a write,
the read operation can be interrupted by a start or stop
condition while the command or address is being clocked
in. While clocking data out, starts or stops cannot be
generated.
At the end of the write the X24C00 will automatically
reset all counters and enter the standby mode.
(Figure 4).
During the second don’t care clock cycle, starts and
stops are ignored. The master must free the bus prior to
the end of this clock cycle to allow the X24C00 to begin
outputting data (Figures 5 and 6).
Figure 4. Write Sequence
START
0
1
A3
A2
A1
A0 XX XX D7 D6 D5 D4 D3 D2 D1 D0
3836 FHD F06
Figure 5. Read Sequence
START
1
0
A3
A2
A1
A0 XX XX D7 D6 D5 D4 D3 D2 D1 D0
3836 FHD F07
Figure 6. Read Cycle Timing
SYMBOL TABLE
WAVEFORM
SCK
6
7
8
SDA IN
A0
XX
XX
SDA OUT
1
D7
D6
3836 FHD F08
4
INPUTS
OUTPUTS
Must be
steady
Will be
steady
May change
from LOW
to HIGH
Will change
from LOW
to HIGH
May change
from HIGH
to LOW
Will change
from HIGH
to LOW
Don’t Care:
Changes
Allowed
N/A
Changing:
State Not
Known
Center Line
is High
Impedance
X24C00
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X24C00 ...................................... –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ............................................ –1V to +7V
D.C. Output Current ............................................. 5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Supply Voltage
Temperature
Min.
Max.
Commercial
Industrial
Military
0°C
–40°C
–55°C
+70°C
+85°C
+125°C
Limits
5V ±10%
3V to 5.5V
2.7V to 5.5V
X24C00
X24C00-3
X24C00-2.7
3836 PGM T03.1
3836 PGM T02.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max.
Units
lCC1
ICC2
ISB1
VCC Supply Current Read
VCC Supply Current Write
VCC Standby Current
1
3
100
mA
ISB2
VCC Standby Current
50
µA
ILI
ILO
VlL(1)
VIH(1)
VOL
VOH
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
10
10
VCC x 0.3
VCC + 0.5
0.4
µA
µA
V
V
V
V
–1
VCC x 0.7
VCC – 0.8
Test Conditions
SCL = VCC x 0.1/VCC x 0.9
Levels @ 1MHz, SDA = Open
SCL = SDA = VCC
VCC = 5V ±10%
SCL = SDA = VCC
VCC = 2.7V
VIN = VSS to VCC
VOUT = VSS to VCC
µA
IOL = 2.1mA
IOH = 1mA
3841 PGM T04.3
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
CI/O(2)
CIN(2)
Parameter
Input/Output Capacitance (SDA)
Input Capacitance (SCL)
Max.
Units
8
6
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
3836 PGM T05.1
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
5
X24C00
POWER-UP TIMING
Symbol
Parameter
Max.
Units
tPUR(3)
tPUW(3)
Power-up to Read Operation
Power-up to Write Operation
2
5
ms
ms
3836 PGM T08
A.C. CONDITIONS OF TEST
EQUIVALENT A.C. LOAD CIRCUIT
Input Pulse Levels
5V
VCC x 0.1 to VCC x 0.9
Input Rise and
Fall Times
Input and Output
Timing Levels
2.16KΩ
OUTPUT
10ns
VCC x 0.5
3836 PGM T06.1
3.07KΩ
100pF
3836 FHD F09.2
A.C. CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Read & Write Cycle Limits
Symbol
fSCL
tAA
tBUF
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
tDH
Parameter
Min.
Max.
Units
SCL Clock Frequency
SCL LOW to SDA Data Out Valid
Time the Bus Must Be Free Before a
New Transmission Can Start
Start Condition Hold Time
Clock LOW Period
Clock HIGH Period
Start Condition Setup Time
Data In Hold Time
Data in Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
0
1
350
MHz
ns
ns
500
250
500
500
250
0
250
1
300
250
50
ns
ns
ns
ns
µs
ns
µs
ns
ns
ns
3836 PGM T07.1
Note:
(3) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
6
X24C00
Bus Timing
tHIGH
tF
tLOW
tR
SCL
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
SDA IN
tAA
tDH
tBUF
SDA OUT
3836 FHD F10
WRITE CYCLE LIMITS
Symbol
Parameter
tWR(4)
Write Cycle Time
Min.
Max.
Units
5
ms
3836 PGM T09
Write Cycle Timing
SCL
SDA
D0
tWR
START
CONDTION
X24C00
ADDRESS
3836 ILL F11.1
Note:
(4) The write cycle time is the time from the initiation of a write sequence to the end of the internal erase/program cycle. During the
write cycle, the X24C00 bus interface circuits are disabled, SDA is high impedance, and the device does not respond to start
conditions.
7
X24C00
PACKAGING INFORMATION
8-LEAD MINIATURE SMALL OUTLINE GULL WING PACKAGE TYPE M
0.118 ± 0.002
(3.00 ± 0.05)
0.012 + 0.006 / -0.002
(0.30 + 0.15 / -0.05)
0.0256 (0.65) TYP
R 0.014 (0.36)
0.118 ± 0.002
(3.00 ± 0.05)
0.030 (0.76)
0.0216 (0.55)
0.036 (0.91)
0.032 (0.81)
0.040 ± 0.002
(1.02 ± 0.05)
0.007 (0.18)
0.005 (0.13)
7° TYP
0.008 (0.20)
0.004 (0.10)
0.150 (3.81)
REF.
0.193 (4.90)
REF.
NOTE:
1. ALL DIMENSIONS IN INCHES AND (MILLIMETERS)
3926 ILL F49
8
X24C00
PACKAGING INFORMATION
8-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P
0.430 (10.92)
0.360 (9.14)
0.260 (6.60)
0.240 (6.10)
PIN 1 INDEX
PIN 1
0.300
(7.62) REF.
HALF SHOULDER WIDTH ON
ALL END PINS OPTIONAL
0.145 (3.68)
0.128 (3.25)
SEATING
PLANE
0.025 (0.64)
0.015 (0.38)
0.065 (1.65)
0.045 (1.14)
0.150 (3.81)
0.125 (3.18)
0.020 (0.51)
0.016 (0.41)
0.110 (2.79)
0.090 (2.29)
0.015 (0.38)
MAX.
0.060 (1.52)
0.020 (0.51)
0.325 (8.25)
0.300 (7.62)
0°
15°
TYP. 0.010 (0.25)
NOTE:
1. ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
2. PACKAGE DIMENSIONS EXCLUDE MOLDING FLASH
3926 FHD F01
9
X24C00
PACKAGING INFORMATION
8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.019 (0.49)
0.188 (4.78)
0.197 (5.00)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.010 (0.25)
X 45°
0.020 (0.50)
0.050" TYPICAL
0.050"
TYPICAL
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.250"
0.016 (0.410)
0.037 (0.937)
0.030"
TYPICAL
8 PLACES
FOOTPRINT
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F22.1
10
X24C00
ORDERING INFORMATION
X24C00
X
X
-X
VCC Range
Blank = 5V ±10%
3 = 3V to 5.5V
2.7 = 2.7V to 5.5V
Device
Temperature Range
Blank = Commercial = 0°C to +70°C
I = Industrial = –40°C to +85°C
M = Military = –55°C to +125°C
Package
M = 8-Lead MSOP
P = 8-Lead Plastic DIP
S = 8-Lead SOIC
Part Mark Convention
X24C00
Blank = 8-Lead SOIC
P = 8-Lead Plastic DIP
X
X
Blank = 4.5V to 5.5V, 0°C to +70°C
I = 4.5V to 5.5V, –40°C to +85°C
M = 4.5V to 5.5V, –55°C to +85°C
D = 3V to 5.5V, 0°C to +70°C
E = 3V to 5.5V, –40°C to +85°C
F = 2.7V to 5.5V, 0°C to +70°C
G = 2.7V to 5.5V, –40°C to +85°C
LIMITED WARRANTY
Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes
no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described
devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness tor any purpose. Xicor, Inc. reserves the right to
discontinue production and change specifications and prices at any time and without notice.
Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents,
licenses are implied.
US. PATENTS
Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481;
4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829,482; 4,874,967; 4,883,976;
4,980,859; 5,012,132; 5,003,197; 5,023,694. Foreign patents and additional patents pending.
LIFE RELATED POLICY
In situations where semiconductor component failure may endanger life, system designers using this product should design the system with
appropriate error detection and correction, redundancy and back-up features to prevent such an occurrence.
Xicor’s products are not authorized for use as critical components in life support devices or systems.
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life,
and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure
of the life support device or system, or to affect its satety or effectiveness.
11