ICMIC X24C04PMG

TM
ICmic
This X24C04 device has been acquired by
IC MICROSYSTEMS from Xicor, Inc.
IC MICROSYSTEMS
X24C04
4K
512 x 8 Bit
2
Serial E PROM
FEATURES
DESCRIPTION
•2.7V to 5.5V Power Supply
•Low Power CMOS
2
The X24C04 is a CMOS 4096 bit serial E PROM,
internally organized 512 x 8. The X24C04 features a
serial interface and software protocol allowing
operation on a simple two wire bus.
—Active Read Current Less Than 1 mA
—Active Write Current Less Than 3 mA
—Standby Current Less Than 50 ∝A
•Internally Organized 512 x 8
•2 Wire Serial Interface
The X24C04 is fabricated with Xicor’s advanced
CMOS Textured Poly Floating Gate Technology.
—Bidirectional Data Transfer Protocol
The X24C04 utilizes Xicor’s proprietary DirectWrite™
cell providing a minimum endurance of 100,000 cycles
and a minimum data retention of 100 years.
•Sixteen Byte Page Write Mode
—Minimizes Total Write Time Per Byte
•Self Timed Write Cycle
—Typical Write Cycle Time of 5 ms
•High Reliability
—Endurance: 100,000 Cycles
—Data Retention: 100 Years
•8 Pin Mini-DIP, 8 Pin SOIC and 14 Pin SOIC
Packages
FUNCTIONAL DIAGRAM
(8) V
CC
(4) V
SS
(7) TEST
H.V. GENERATION
TIMING
START CYCLE
& CONTROL
(5) SDA
START
STOP
LOGIC
CONTROL
LOGIC
SLAVE ADDRESS
REGISTER
(6) SCL
2
LOAD
+COMPARATOR
(3) A 2
INC
E PROM
32 X 128
XDEC
WORD
ADDRESS
COUNTER
(2) A 1
(1) A 0
R/W
YDEC
8
CK
PIN
D
DATA REGISTER
OUT
D
OUT
ACK
3839 FHD F01
DirectWrite™ is a trademark of Xicor, Inc.
© Xicor, 1991 Patents Pending
3839-1
1
Characteristics subject to change without notice
X24C04
PIN DESCRIPTIONS
PIN CONFIGURATION
Serial Clock (SCL)
The SCL input is used to clock all data into and out of the
device.
DIP/SOIC
Serial Data (SDA)
SDA is a bidirectional pin used to transfer data into and out
of the device. It is an open drain output and may be
wire-ORed with any number of open drain or open
collector outputs.
A
0
A
1
1
8
2
7
A
2
V
SS
3
X24C04
4
V
6
CC
TEST
SCL
5
SDA
3839 FHD F02
An open drain output requires the use of a pull-up
resistor. For selecting typical values, refer to the Pull-Up
Resistor selection graph at the end of this data sheet.
SOIC
Address (A0)
A0 is unused by the X24C04, however, it must be tied to VSS
to insure proper device operation.
Address (A1, A2)
The Address inputs are used to set the appropriate bits of
the seven bit slave address. These inputs can be used
static or actively driven. If used statically they must be
VSS or VCC as appropriate. If driven they must be
tied to
driven to VSS or to VCC.
NC
1
14
A
0
A
1
2
13
3
12
NC
4
X24C04 11
A
2
V
SS
5
10
6
9
SCL
SDA
NC
7
8
NC
NC
V
CC
TEST
NC
3839 FHD F03
PIN NAMES
Symbol
Description
A0–A2
SDA
SCL
TEST
VSS
VCC
NC
Address Inputs
Serial Data
Serial Clock
Hold at VSS
Ground
Supply Voltage
No Connect
3839 PGM T01
2
X24C04
DEVICE OPERATION
The X24C04 supports a bidirectional bus oriented protocol.
The protocol defines any device that sends data
Clock and Data Conventions
Data states on the SDA line can change only during SCL
LOW. SDA state changes during SCL HIGH are re-
onto the bus as a transmitter, and the receiving device as
the receiver. The device controlling the transfer is a
served for indicating start and stop conditions. Refer to
Figures 1 and 2.
master and the device being controlled is the slave. The
master will always initiate data transfers, and provide
Start Condition
All command are preceded by the start condition, which
is a HIGH to LOW transition of SDA when SCL is
the clock for both transmit and receive operations.
Therefore, the X24C04 will be considered a slave in all
applications.
HIGH. The X24C04 continuously monitors the SDA and SCL
lines for the start condition and will not respond to
any command until this condition has been met.
Figure 1. Data Validity
SCL
SDA
DATA STABLE
DATA
CHANGE
3839 FHD F06
Figure 2. Definition of Start and Stop
SCL
SDA
START BIT
STOP BIT
3
3839 FHD F07
X24C04
The X24C04 will respond with an acknowledge after
recognition of a start condition and its slave address.
If the device and a write operation have been selected, the
X24C04 will respond with an acknowledge after the
receipt of each subsequent eight bit word.
Stop Condition
All communications must be terminated by a stop condition, which is a LOW to HIGH transition of SDA when SCL
is HIGH. The stop condition is also used by the X24C04 to
place the device in the standby power mode after a read
sequence. A stop condition can only be issued after the
transmitting device has released the bus.
In the read mode the X24C04 will transmit eight bits of data,
release the SDA line and monitor the line for an
acknowledge. If an acknowledge is detected and no stop
condition is generated by the master, the X24C04
Acknowledge
Acknowledge is a software convention used to indicate
successful data transfer. The transmitting device, either
master or slave, will release the bus after transmitting eight
bits. During the ninth clock cycle the receiver will
will continue to transmit data. If an acknowledge is not
detected, the X24C04 will terminate further data transmissions
The master must then issue a stop condition to return the
X24C04 to the standby power mode and place the device
pull the SDA line LOW to acknowledge that it received the
eight bits of data. Refer to Figure 3.
into a known state.
Figure 3. Acknowledge Response From Receiver
SCL FROM
MASTER
1
8
9
DATA
OUTPUT
FROM
TRANSMITTER
DATA
OUTPUT
FROM
RECEIVER
START
ACKNOWLEDGE
3839 FHD F08
4
X24C04
DEVICE ADDRESSING
The last bit of the slave address defines the operation to be
performed. When set to one a read operation is
Following a start condition the master must output the
address of the slave it is accessing. The most significant
selected, when set to zero a write operation is selected.
four bits of the slave are the device type identifier (see
Figure 4). For the X24C04 this is fixed as 1010[B].
Following the start condition, the X24C04 monitors the
SDA bus comparing the slave address being transmitted
with its slave address (device type and state of A1
and A2 inputs). Upon a correct compare the X24C04
Figure 4. Slave Address
DEVICE TYPE
IDENTIFIER
1
0
1
outputs an acknowledge on the SDA line. Depending on the
state of the R/W bit, the X24C04 will execute a read
HIGH
ORDER
DEVICE
WORD
ADDRESS ADDRESS
0
A2
A1
A0
or write operation.
WRITE OPERATIONS
R/W
Byte Write
For a write operation, the X24C04 requires a second
address field. This address field is the word address,
comprised of eight bits, providing access to any one of the
512 words of memory. Upon receipt of the word address
the X24C04 responds with an acknowledge, and awaits the
next eight bits of data, again responding with an
3839 FHD F09
The next two significant bits address a particular device. A
system could have up to four X24C04 devices on the
bus (see Figure 10). The four addresses are defined by the
state of the A1 and A2 inputs.
acknowledge. The master then terminates the transfer by
generating a stop condition, at which time the X24C04
begins the internal write cycle to the nonvolatile memory.
While the internal write cycle is in progress the X24C04
The next bit of the slave address is an extension of the
array’s address and is concatenated with the eight bits
of address in the word address field, providing direct access
to the whole 512 x 8 array.
inputs are disabled, and the device will not respond to any
requests from the master. Refer to Figure 5 for the
address, acknowledge and data transfer sequence.
Figure 5. Byte Write
S
T
SLAVE
ADDRESS
WORD
ADDRESS
S
T
BUS ACTIVITY:
MASTER
A
R
T
O
P
SDA LINE
S
P
BUS ACTIVITY:
X24C04
DATA
A
C
A
C
A
C
K
K
K
3839 FHD F10
5
X24C04
It should be noted that the ninth clock cycle of the read
operation is not a “don’t care.” To terminate a read
Page Write
The X24C04 is capable of a sixteen byte page write
operation. It is initiated in the same manner as the byte
write operation, but instead of terminating the write cycle after
the first data word is transferred, the master can
operation, the master must either issue a stop condition
during the ninth cycle or hold SDA HIGH during the ninth
clock cycle and then issue a stop condition.
transmit up to fifteen more words. After the receipt of each
word, the X24C04 will respond with an acknowledge.
Flow 1. ACK Polling Sequence
After the receipt of each word, the four low order address bits
are internally incremented by one. The high order five
WRITE OPERATION
COMPLETED
bits of the address remain constant. If the master should
transmit more than sixteen words prior to generating the
ENTER ACK POLLING
stop condition, the address counter will “roll over” and the
previously written data will be overwritten. As with the byte
write operation, all inputs are disabled until completion of the
internal write cycle. Refer to Figure 6 for the address,
ISSUE
START
acknowledge and data transfer sequence.
ISSUE SLAVE
ADDRESS AND R/W = 0
Acknowledge Polling
The disabling of the inputs can be used to take advan- tage
of the typical 5 ms write cycle time. Once the stop
condition is issued to indicate the end of the host’s write
operation the X24C04 initiates the internal write cycle.
ACK
RETURNED?
ACK polling can be initiated immediately. This involves
issuing the start condition followed by the slave address
YES
for a write operation. If the X24C04 is still busy with the write
operation no ACK will be returned. If the X24C04
ISSUE STOP
NO
NEXT
OPERATION
NO
A WRITE?
has completed the write operation an ACK will be
returned and the host can then proceed with the next
read or write operation. Refer to Flow 1.
YES
READ OPERATIONS
ISSUE BYTE
ADDRESS
ISSUE STOP
PROCEED
PROCEED
Read operations are initiated in the same manner as write
operations with the exception that the R/W bit of the
slave address is set to a one. There are three basic read
operations: current address read, random read and
sequential read.
3839 FHD F12
Figure 6. Page Write
S
T
BUS ACTIVITY:
MASTER
A
R
T
SDA LINE
S
BUS ACTIVITY:
X24C04
SLAVE
ADDRESS
WORD
ADDRESS (n)
DATA n
DATA n+1
S
T
DATA n+15
O
P
P
A
C
K
A
C
K
A
C
K
NOTE: In this example n = xxxx 000 (B); x = 1 or 0
6
A
C
K
A
C
K
3839 FHD F11
X24C04
Current Address Read
Random Read
Internally the X24C04 contains an address counter that
maintains the address of the last word accessed,
incremented by one. Therefore, if the last access (either a
read or write) was to address n, the next read operation
Random read operations allow the master to access any
memory location in a random manner. Prior to issuing
would access data from address n + 1. Upon receipt of the
slave address with the R/W bit set to one, the
X24C04 issues an acknowledge and transmits the eight bit
word. The read operation is terminated by the master;
tion. The master issues the start condition, and the slave
address followed by the word address it is to read.
After the word address acknowledge, the master
immediately reissues the start condition and the slave
by not responding with an acknowledge and by issuing a
stop condition. Refer to Figure 7 for the sequence of
address with the R/W bit set to one. This will be followed by
an acknowledge from the X24C04 and then by the
address, acknowledge and data transfer.
eight bit word. The read operation is terminated by the
master; by not responding with an acknowledge and by
the slave address with the R/W bit set to one, the master
must first perform a “dummy” write opera-
issuing a stop condition. Refer to Figure 8 for the
address, acknowledge and data transfer sequence.
Figure 7. Current Address Read
S
T
SLAVE
ADDRESS
S
T
BUS ACTIVITY:
MASTER
A
R
T
O
P
SDA LINE
S
P
DATA
A
C
BUS ACTIVITY:
X24C04
K
3839 FHD F13
Figure 8. Random Read
S
T
BUS ACTIVITY:
MASTER
A
R
SDA LINE
S
BUS ACTIVITY:
X24C04
SLAVE
ADDRESS
S
T
WORD
ADDRESS n
A
R
T
SLAVE
ADDRESS
DATA n
T
S
S
T
O
P
P
A
C
A
C
A
C
K
K
K
3839 FHD F14
7
X24C04
The data output is sequential, with the data from address n
followed by the data from n + 1. The address counter
Sequential Read
Sequential Read can be initiated as either a current
address read or random access read. The first word is
for read operations increments all address bits, allowing the
entire memory contents to be serially read during
transmitted as with the other modes, however, the
master now responds with an acknowledge, indicating it
one operation. At the end of the address space (address 511),
the counter “rolls over” to address 0 and the
requires additional data. The X24C04 continues to out- put
data for each acknowledge received. The read
X24C04 continues to output data for each acknowledge
received. Refer to Figure 9 for the address, acknowledge
operation is terminated by the master; by not responding with
an acknowledge and by issuing a stop condition.
and data transfer sequence.
Figure 9. Sequential Read
BUS ACTIVITY:
MASTER
SLAVE
ADDRESS
A
C
A
C
A
C
K
K
K
S
T
O
P
SDA LINE
BUS ACTIVITY:
X24C04
P
A
C
K
DATA n
DATA n+1
DATA n+2
DATA n+x
3839 FHD F16
Figure 10. Typical System Configuration
V
CC
PULL-UP
RESISTORS
SDA
SCL
MASTER
TRANSMITTER/
RECEIVER
SLAVE
RECEIVER
SLAVE
TRANSMITTER/
MASTER
TRANSMITTER
RECEIVER
MASTER
TRANSMITTER/
RECEIVER
3839 FHD F17
8
X24C04
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to V SS ............................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
Lead Temperature (Soldering,
............................. 300°C
10 Seconds)
This is a stress rating only and the functional operation of the
device at these or any other conditions above those
indicated in the operational sections of this specification is not
implied. Exposure to absolute maximum rating condition
for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
Industrial
Military
0°C
–40°C
–55°C
70°C
+85°C
+125°C
X24C04
X24C04-3.5
X24C04-3
X24C04-2.7
4.5V to 5.5V
3.5V to 5.5V
3V to 5.5V
2.7V to 5.5V
3836 PGM T02
3836 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Limits
Symbol
Parameter
ICC1
ICC2
VCC Supply Current (Read)
VCC Supply Current (Write)
ISB1(1)
ISB2(1)
ILI
ILO
VlL(2)
VIH(2)
VOL
Min.
Max.
Units
1
3
mA
VCC Standby Current
150
∝A
VCC Standby Current
50
∝A
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
10
10
VCC x 0.3
–1.0
VCC x 0.7VCC + 0.5
0.4
Test Conditions
SCL = VCC x 0.1/VCC x 0.9 Levels
@ 100 KHz, SDA = Open, All Other
Inputs = GND or VCC – 0.3V
SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 5.5V
SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC,
∝A
∝A
VCC = 3V
VIN = GND to VCC
VOUT = GND to VCC
V
V
V
IOL = 3 mA
3839 PGM T03
CAPACITANCE TA = 25°C, f = 1.0MHz, VCC = 5V
Symbol
CI/O(3)
CIN(3)
Parameter
Max.
Units
Test Conditions
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, SCL)
8
6
pF
pF
VI/O = 0V
VIN = 0V
3839 PGM T05
Notes:(1)Must perform a stop command prior to measurement.
(2)VIL min. and VIH max. are for reference only and are not tested.
(3)This parameter is periodically sampled and not 100% tested.
9
X24C04
A.C. CONDITIONS OF TEST
Input Pulse Levels
EQUIVALENT A.C. LOAD CIRCUIT
5.0V
VCC x 0.1 to VCC x 0.9
1533Ο
Input Rise and
Fall Times
10 ns
Output
100pF
Input and Output
Timing Levels
VCC x 0.5
3839 PGM T02
A.C. CHARACTERISTICS (Over recommended operating conditions unless otherwise specified) Read
& Write Cycle Limits
Symbol
Parameter
fSCL
TI
SCL Clock Frequency
Noise Suppression Time
Constant at SCL, SDA Inputs
SCL Low to SDA Data Out Valid
Time the Bus Must Be Free Before a
New Transmission Can Start
Start Condition Hold Time
Clock Low Period
Clock High Period
Start Condition Setup Time
(for a Repeated Start Condition)
Data In Hold Time
Data In Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
tAA
tBUF
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
tDH
Min.
Max.
Units
0
100
100
KHz
ns
0.3
4.7
3.5
∝s
∝s
4.0
4.7
4.0
4.7
∝s
∝s
∝s
∝s
0
250
∝s
ns
∝s
1
300
ns
∝s
4.7
300
ns
3839 PGM T06
POWER-UP TIMING
Symbol
t
tPUW(4)
(4)
PUR
Parameter
Max.
Units
Power-up to Read Operation
Power-up to Write Operation
1
5
ms
ms
3839 PGM T07
Bus Timing
t
t
F
HIGH
t
t
LOW
R
SCL
t
SU:STA
t
HD:STA
t
t
HD:DAT
SU:DAT
t
SU:STO
SDA IN
t
t
AA
DH
t
BUF
SDA OUT
3839 FHD F04
Notes:(4) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These
parameters are periodically sampled and not 100% tested.
10
X24C04
Write Cycle Limits
Symbol
Parameter
t
(5)
Min.
Typ.
Write Cycle Time
(6)
WR
Max.
Units
10
ms
5
3839 PGM T08
The write cycle time is the time from a valid stop
condition of a write sequence to the end of the internal
bus interface circuits are disabled, SDA is allowed to remain
high, and the device does not respond to its slave
erase/program cycle. During the write cycle, the X24C04
address.
Write Cycle Timing
SCL
ACK
8th BIT
SDA
WORD n
t
WR
STOP
CONDITION
START
CONDITION
X24C04
ADDRESS
3839 FHD F05
Notes: (5) Typical values are for TA = 25°C and nominal supply voltage (5V).
(6) tWR is the minimum cycle time from the system perspective when polling techniques are not used. It is the maximum time the
device requires to perform the internal write operation.
SYMBOL TABLE
Guidelines for Calculating Typical
Values of Bus Pull-Up Resistors
RESISTANCE (KΟ)
120
V
R
MIN
100
80
R
MAX
=
=
WAVEFORM
CC MAX
I
OL MIN
=1.8KΟ
t
R
C
BUS
MAX.
RESISTANCE
60
40
20
MIN.
RESISTANCE
0
0
20 40
60
INPUTS
OUTPUTS
Must be
steady
Will be
steady
May change
from Low to
Will change
from Low to
High
High
May change
from High to
Will change
from High to
Low
Low
Don’t Care:
Changes
Changing:
State Not
Allowed
Known
N/A
Center Line
is High
80100120
BUS CAPACITANCE (pF)
3839 FHD F18
Impedance
11
X24C04
PACKAGING INFORMATION
8-LEAD PLASTIC SMALL OUTLINE
GULL WING PACKAGE TYPE S
8-LEAD PLASTIC DUAL
IN-LINE PACKAGE TYPE P
0.430 (10.92)
0.360 (9.14)
0.150 (3.80)
0.158 (4.00)
0.092 (2.34)
DIA. NOM.
0.228 (5.80)
0.244 (6.20)
0.255 (6.47)
0.245 (6.22)
PIN 1 INDEX
PIN 1 INDEX
PIN 1
PIN 1
0.300
(7.62) REF.
0.014 (0.35)
0.019 (0.49)
0.060 (1.52)
0.020 (0.51)
HALF SHOULDER
WIDTH ON ALL END
PINS OPTIONAL
0.188 (4.78)
0.197 (5.00)
(4X) 7°
0.140 (3.56)
0.130 (3.30)
SEATING
PLANE
0.020 (0.51)
0.015 (0.38)
0.150 (3.81)
0.125 (3.18)
0.053 (1.35)
0.069 (1.75)
0.062 (1.57)
0.058 (1.47)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.110 (2.79)
0.090 (2.29)
0.010 (0.25)
X 45°
0.020 (0.50)
0.015 (0.38)
MAX.
0.020 (0.51)
0.016 (0.41)
0.325 (8.25)
0.300 (7.62)
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.027 (0.683)
0.037 (0.937)
TYP. 0.010 (0.25)
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
12
0°
15°
X24C04
PACKAGING INFORMATION
14-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.019 (0.49)
0.336 (8.55)
0.345 (8.75)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.010 (0.25)
X 45°
0.020 (0.50)
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.027 (0.683)
0.037 (0.937)
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
13
X24C04
ORDERING INFORMATION
X24C04
P
T G -V
Device
VCC Limits
Blank = 4.5V to 5.5V
3.5 = 3.5V to 5.5V
3 = 3.0 to 5.5V
2.7 = 2.7V to 5.5V
G=RoHS Compliant Lead Free package
Blank = Standard package. Non lead free
Temperature Range
Blank = Commercial = 0°C to +70°C
I = Industrial = –40°C to +85°C
M = Military = –55°C to +125°C
Package
P = 8-Lead Plastic DIP
S8 = 8-Lead SOIC
S14 = 14-Lead SOIC
Part Mark Convention
X24C04
Blank = 8-Lead SOIC
P = 8-Lead Plastic DIP
S8 = 8-Lead SOIC
S14 = 14-Lead SOIC
G = RoHS compliant lead free
XG
X
Blank = 4.5V to 5.5V, 0°C to +70°C
I = 4.5V to 5.5V, –40°C to +85°C
B = 3.5V to 5.5V, 0°C to +70°C
C = 3.5V to 5.5V, –40°C to +85°C
D = 3.0V to 5.5V, 0°C to +70°C
E = 3.0V to 5.5V, –40°C to +85°C
F = 2.7V to 5.5V, 0°C to +70°C
G = 2.7V to 5.5V, –40°C to +85°C
LIMITED WARRANTY
Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty, express,
statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Xicor, Inc. makes no
warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without
notice.
Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, licenses are implied.
U.S. PATENTS
Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481; 4,404,475; 4,450,402;
4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967; 4,883, 976. Foreign patents and additional patents
pending.
LIFE RELATED POLICY
In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection
and correction, redundancy and back-up features to prevent such an occurence.
Xicor's products are not authorized for use in critical components in life support devices or systems.
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the
user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
14
X24C04
8-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P
0.430 (10.92)
0.360 (9.14)
0.260 (6.60)
0.240 (6.10)
PIN 1 INDEX
PIN 1
0.300
(7.62) REF.
HALF SHOULDER WIDTH ON
ALL END PINS OPTIONAL
0.060 (1.52)
0.020 (0.51)
0.145 (3.68)
0.128 (3.25)
SEATING
PLANE
0.025 (0.64)
0.015 (0.38)
0.150 (3.81)
0.125 (3.18)
0.065 (1.65)
0.045 (1.14)
0.110 (2.79)
0.090 (2.29)
0.015 (0.38)
MAX.
0.020 (0.51)
0.016 (0.41)
0.325 (8.25)
0.300 (7.62)
0°
15°
TYP. 0.010 (0.25)
NOTE:
1. ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 2.
PACKAGE DIMENSIONS EXCLUDE MOLDING FLASH
3926 FHD F01
15
X24C04
8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.019 (0.49)
0.188 (4.78)
0.197 (5.00)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.050" TYPICAL
0.010 (0.25)
X 45°
0.020 (0.50)
0.050"
TYPICAL
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.250"
0.016 (0.410)
0.037 (0.937)
0.030"
TYPICAL
8 PLACES
FOOTPRINT
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESIS IN MILLIMETERS)
3926 FHD F22
16
X24C04
14-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.020 (0.51)
0.336 (8.55)
0.345 (8.75)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.10)
0.010 (0.25)
0.050 (1.27)
0.050" Typical
0.010 (0.25)
X 45°
0.020 (0.50)
0° – 8°
0.050" Typical
0.0075 (0.19)
0.010 (0.25)
0.250"
0.016 (0.41)
0.037 (0.937)
FOOTPRINT
0.030" Typical
14 Places
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F10
17
X24C04
8-LEAD HERMETIC DUAL IN-LINE PACKAGE TYPE D
0.405 (10.29)
––
0.310 (7.87)
0.220 (5.59)
PIN 1
0.005 (0.13) MIN.
0.300 (7.62)
REF.
SEATING
PLANE
0.150 (3.81) MIN.
0.055 (1.40) MAX.
0.200 (5.08)
0.140 (3.56)
0.060 (1.52)
0.015 (0.38)
0.200 (5.08)
0.125 (3.18)
0.065 (1.65)
0.038 (0.97)
TYP. 0.060 (1.52)
0.110 (2.79)
0.090 (2.29)
0.023 (0.58)
0.014 (0.36)
TYP. 0.100 (2.54)
TYP. 0.017 (0.43)
0.320 (8.13)
0.290 (7.37)
TYP. 0.311 (7.90)
0°
15°
0.015 (0.38)
0.008 (0.20)
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F05
18