X24164 Preliminary Information X24164 16K 2048 x 8 Bit Serial E2PROM FEATURES DESCRIPTION • • The X24164 is a CMOS 16,384 bit serial E2PROM, internally organized 2048 x 8. The X24164 features a serial interface and software protocol allowing operation on a simple two wire bus. • • • • • • • 2.7V to 5.5V Power Supply Low Power CMOS —Active Read Current Less Than 1 mA —Active Write Current Less Than 3 mA —Standby Current Less Than 50 µA Internally Organized 2048 x 8 2 Wire Serial Interface —Bidirectional Data Transfer Protocol Sixteen Byte Page Write Mode —Minimizes Total Write Time Per Byte Self Timed Write Cycle —Typical Write Cycle Time of 5 ms High Reliability —Endurance: 100,000 Cycles —Data Retention: 100 Years Pin and Function Compatible with X24C16 8-Pin Plastic DIP and 8-Lead SOIC Packages Three device select inputs (S0–S2) allow up to eight devices to share a common two wire bus. Xicor E2PROMs are designed and tested for applications requiring extended endurance. Inherent data retention is greater than 100 years. FUNCTIONAL DIAGRAM (8) VCC (4) VSS (5) SDA H.V. GENERATION TIMING & CONTROL START CYCLE START STOP LOGIC CONTROL LOGIC (6) SCL SLAVE ADDRESS REGISTER +COMPARATOR LOAD (3) S2 (2) S1 INC E2PROM 128 X 128 XDEC WORD ADDRESS COUNTER (1) S0 R/W YDEC 8 CK PIN DATA REGISTER DOUT DOUT ACK © Xicor, 1991 Patents Pending 3846-1.2 7/30/96 T0/C1/D1 SH 3846 FHD F01 1 Characteristics subject to change without notice X24164 PIN DESCRIPTIONS PIN CONFIGURATION Serial Clock (SCL) The SCL input is used to clock all data into and out of the device. DIP/SOIC Serial Data (SDA) S0 1 8 VCC SDA is a bidirectional pin used to transfer data into and out of the device. It is an open drain output and may be wire-ORed with any number of open drain or open collector outputs. S1 2 7 TEST S2 3 6 SCL VSS 4 5 SDA 3846 FHD F02 An open drain output requires the use of a pull-up resistor. For selecting typical values, refer to the Pull-Up Resistor selection graph at the end of this data sheet. Device Select (S0, S1, S2) The device select inputs (S0, S1, S2) are used to set the second, third and fourth bits of the 8 bit slave address. This allows up to eight X24164’s to share a common bus. These inputs can be static or actively driven. If used statically they must be tied to VSS or VCC as appropriate. If actively driven, they must be driven to VSS or VCC. To be compatible with the X24C16 these pins must all be tied to VSS. Pin Names Symbol S0–S2 SDA SCL TEST VSS VCC X24164 Description Device Select Inputs Serial Data Serial Clock Hold at VSS Ground Supply Voltage 3846 PGM T01 2 X24164 DEVICE OPERATION Clock and Data Conventions The X24164 supports a bidirectional bus oriented protocol. The protocol defines any device that sends data onto the bus as a transmitter, and the receiving device as the receiver. The device controlling the transfer is a master and the device being controlled is the slave. The master will always initiate data transfers, and provide the clock for both transmit and receive operations. Therefore, the X24164 will be considered a slave in all applications. Data states on the SDA line can change only during SCL LOW. SDA state changes during SCL HIGH are reserved for indicating start and stop conditions. Refer to Figures 1 and 2. Start Condition All commands are preceded by the start condition, which is a HIGH to LOW transition of SDA when SCL is HIGH. The X24164 continuously monitors the SDA and SCL lines for the start condition and will not respond to any command until this condition has been met. Figure 1. Data Validity SCL SDA DATA STABLE DATA CHANGE 3846 FHD F07 Notes: (5) Typical values are for TA = 25°C and nominal supply voltage (5V) (6) tWR is the minimum cycle time from the system perspective when polling techniques are not used. It is the maximum time the device requires to perform the internal write operation. Figure 2. Definition of Start and Stop SCL SDA START BIT STOP BIT 3846 FHD F08 3 X24164 Stop Condition The X24164 will respond with an acknowledge after recognition of a start condition and its slave address. If both the device and a write operation have been selected, the X24164 will respond with an acknowledge after the receipt of each subsequent eight bit word. All communications must be terminated by a stop condition, which is a LOW to HIGH transition of SDA when SCL is HIGH. The stop condition is also used to place the device into the standby power mode after a read sequence. A stop condition can only be issued after the transmitting device has released the bus. In the read mode the X24164 will transmit eight bits of data, release the SDA line and monitor the line for an acknowledge. If an acknowledge is detected and no stop condition is generated by the master, the X24164 will continue to transmit data. If an acknowledge is not detected, the X24164 will terminate further data transmissions. The master must then issue a stop condition to return the X24164 to the standby power mode and place the device into a known state. Acknowledge Acknowledge is a software convention used to indicate successful data transfer. The transmitting device, either master or slave, will release the bus after transmitting eight bits. During the ninth clock cycle the receiver will pull the SDA line LOW to acknowledge that it received the eight bits of data. Refer to Figure 3. Figure 3. Acknowledge Response From Receiver SCL FROM MASTER 1 8 9 DATA OUTPUT FROM TRANSMITTER DATA OUTPUT FROM RECEIVER START ACKNOWLEDGE 3846 FHD F09 4 X24164 DEVICE ADDRESSING The last bit of the slave address defines the operation to be performed. When set to one a read operation is selected, when set to zero a write operation is selected. Following a start condition the master must output the address of the slave it is accessing. The most significant bit of the slave is a one (see Figure 4). The next three bits are the device select bits. A system could have up to eight X24164’s on the bus. The eight addresses are defined by the state of the S0, S1, and S2 inputs. S1 of the slave address must be the inverse of the S1 input pin. Following the start condition, the X24164 monitors the SDA bus comparing the slave address being transmitted with its slave address device type identifier. Upon a correct compare the X24164 outputs an acknowledge on the SDA line. Depending on the state of the R/W bit, the X24164 will execute a read or write operation. Figure 4. Slave Address WRITE OPERATIONS HIGH ORDER WORD ADDRESS DEVICE SELECT 1 S2 S1 S0 A2 A1 A0 Byte Write For a write operation, the X24164 requires a second address field. This address field is the word address, comprised of eight bits, providing access to any one of 2048 words in the array. Upon receipt of the word address the X24164 responds with an acknowledge, and awaits the next eight bits of data, again responding with an acknowledge. The master then terminates the transfer by generating a stop condition, at which time the X24164 begins the internal write cycle to the nonvolatile memory. While the internal write cycle is in progress the X24164 inputs are disabled, and the device will not respond to any requests from the master. Refer to Figure 5 for the address, acknowledge and data transfer sequence. R/W 3846 FHD F10 The next three bits of the slave address are an extension of the array’s address and are concatenated with the eight bits of address in the word address field, providing direct access to the whole 2048 x 8 array. Figure 5. Byte Write S T BUS ACTIVITY: A R MASTER T SDA LINE BUS ACTIVITY: X24164 WORD ADDRESS SLAVE ADDRESS S T O P DATA S P A C K A C K A C K 3846 FHD F11 5 X24164 Page Write Flow 1. ACK Polling Sequence The X24164 is capable of a sixteen byte page write operation. It is initiated in the same manner as the byte write operation, but instead of terminating the write cycle after the first data word is transferred, the master can transmit up to fifteen more words. After the receipt of each word, the X24164 will respond with an acknowledge. WRITE OPERATION COMPLETED ENTER ACK POLLING ISSUE START After the receipt of each word, the four low order address bits are internally incremented by one. The high order seven bits of the word address remain constant. If the master should transmit more than sixteen words prior to generating the stop condition, the address counter will “roll over” and the previously written data will be overwritten. As with the byte write operation, all inputs are disabled until completion of the internal write cycle. Refer to Figure 6 for the address, acknowledge and data transfer sequence. ISSUE SLAVE ADDRESS AND R/W = 0 ACK RETURNED? Acknowledge Polling ISSUE STOP NO YES The disabling of the inputs can be used to take advantage of the typical 5 ms write cycle time. Once the stop condition is issued to indicate the end of the host’s write operation the X24164 initiates the internal write cycle. ACK polling can be initiated immediately. This involves issuing the start condition followed by the slave address for a write operation. If the X24164 is still busy with the write operation no ACK will be returned. If the X24164 has completed the write operation an ACK will be returned and the host can then proceed with the next read or write operation. Refer to Flow 1. NEXT OPERATION A WRITE? NO YES ISSUE BYTE ADDRESS ISSUE STOP PROCEED PROCEED 3846 FHD F12 Figure 6. Page Write S T BUS ACTIVITY: A R MASTER T SDA LINE BUS ACTIVITY: X24164 SLAVE ADDRESS WORD ADDRESS (n) DATA n DATA n+1 S T O P DATA n+15 S P A C K A C K A C K A C K A C K NOTE: In this example n = xxxx 0000 (B); x = 1 or 0 3846 FHD F13 6 X24164 READ OPERATIONS The read operation is terminated by the master; by not responding with an acknowledge and by issuing a stop condition. Refer to Figure 7 for the sequence of address, acknowledge and data transfer. Read operations are initiated in the same manner as write operations with the exception that the R/W bit of the slave address is set to a one. There are three basic read operations: current address read, random read and sequential read. Random Read Random read operations allow the master to access any memory location in a random manner. Prior to issuing the slave address with the R/W bit set to one, the master must first perform a “dummy” write operation. The master issues the start condition, and the slave address followed by the word address it is to read. After the word address acknowledge, the master immediately reissues the start condition and the slave address with the R/W bit set to one. This will be followed by an acknowledge from the X24164 and then by the eight bit word. The read operation is terminated by the master; by not responding with an acknowledge and by issuing a stop condition. Refer to Figure 8 for the address, acknowledge and data transfer sequence. It should be noted that the ninth clock cycle of the read operation is not a “don’t care.” To terminate a read operation, the master must either issue a stop condition during the ninth cycle or hold SDA HIGH during the ninth clock cycle and then issue a stop condition. Current Address Read Internally the X24164 contains an address counter that maintains the address of the last word accessed, incremented by one. Therefore, if the last access (either a read or write) was to address n, the next read operation would access data from address n + 1. Upon receipt of the slave address with the R/W set to one, the X24164 issues an acknowledge and transmits the eight bit word. Figure 7. Current Address Read S T BUS ACTIVITY: A R MASTER T SDA LINE S T O P SLAVE ADDRESS S P A C K BUS ACTIVITY: X24164 DATA 3846 FHD F14 Figure 8. Random Read S T BUS ACTIVITY: A R MASTER T SDA LINE BUS ACTIVITY: X24164 SLAVE ADDRESS S T A R T WORD ADDRESS n S S T O P SLAVE ADDRESS S A C K A C K P A C K DATA n 3846 FHD F15 7 X24164 Sequential Read The data output is sequential, with the data from address n followed by the data from n + 1. The address counter for read operations increments all address bits, allowing the entire memory contents to be serially read during one operation. At the end of the address space (address 2047), the counter “rolls over” to 0 and the X24164 continues to output data for each acknowledge received. Refer to Figure 9 for the address, acknowledge and data transfer sequence. Sequential reads can be initiated as either a current address read or random access read. The first word is transmitted as with the other modes, however, the master now responds with an acknowledge, indicating it requires additional data. The X24164 continues to output data for each acknowledge received. The read operation is terminated by the master; by not responding with an acknowledge and by issuing a stop condition. Figure 9. Sequential Read SLAVE BUS ACTIVITY: ADDRESS MASTER A C K A C K S T O P A C K P SDA LINE BUS ACTIVITY: X24164 A C K DATA n+1 DATA n DATA n+2 DATA n+x 3846 FHD F16 Figure 10. Typical System Configuration VCC PULL-UP RESISTORS SDA SCL MASTER TRANSMITTER/ RECEIVER SLAVE RECEIVER SLAVE TRANSMITTER/ RECEIVER MASTER TRANSMITTER MASTER TRANSMITTER/ RECEIVER 3846 FHD F17 8 X24164 ABSOLUTE MAXIMUM RATINGS* Temperature Under Bias X24164 ...................................... –65°C to +135°C Storage Temperature ....................... –65°C to +150°C Voltage on any Pin with Respect to VSS ................................ –1.0V to +7.0V D.C. Output Current ............................................ 5 mA Lead Temperature (Soldering, 10 Seconds) ..... 300°C *COMMENT Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and the functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. RECOMMENDED OPERATING CONDITIONS Temperature Min. Max. Supply Voltage Limits Commercial Industrial Military 0°C –40°C –55°C 70°C +85°C +125°C X24164 X24164-3 X24164-2.7 4.5V to 5.5V 3V to 5.5V 2.7V to 5.5V 3846 PGM T02 3846 PGM T03 D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.) Limits Symbol Max. Units VCC Supply Current (Read) 1 mA SCL = VCC X 0.1/VCC X 0.9 Levels @ 100 KHz, SDA = Open, All VCC Supply Current (Write) VCC Standby Current 3 150 mA µA ISB2(1) VCC Standby Current 50 µA ILI ILO VlL(2) VIH(2) VOL Input Leakage Current Output Leakage Current Input Low Voltage Input High Voltage Output Low Voltage Inputs = GND or VCC – 0.3V SCL = SDA = VCC, All Other Inputs = GND or VCC – 0.3V, VCC = 5V ± 10% SCL = SDA = VCC, All Other Inputs = GND or VCC – 0.3V, VCC = 3V VIN = GND to VCC VOUT = GND to VCC ICC1 Other ICC2 ISB1(1) Parameter Min. 10 10 –1.0 VCC x 0.3 VCC x 0.7 VCC + 0.5 0.4 µA µA V V V Test Conditions IOL = 3 mA 3846 PGM T04 CAPACITANCE TA = 25°C, f = 1.0 MHz, VCC = 5V Symbol CI/O(3) CIN(3) Parameter Input/Output Capacitance (SDA) Input Capacitance (S0, S1, S2, SCL) Max. Units Test Conditions 8 6 pF pF VI/O = 0V VIN = 0V 3846 PGM T05 Notes: (1) Must perform a stop command prior to measurement. (2) VIL min. and VIH max. are for reference only and are not 100% tested. (3) This parameter is periodically sampled and not 100% tested. 9 X24164 A.C. CONDITIONS OF TEST Input Pulse Levels Input Rise and Fall Times Input and Output Timing Levels EQUIVALENT A.C. LOAD CIRCUIT 5V VCC x 0.1 to VCC x 0.9 1533Ω 10 ns OUTPUT VCC X 0.5 100pF 3846 PGM T06 3846 FHD F04 A.C. CHARACTERISTICS (Over recommended operating range unless otherwise specified) Read & Write Cycle Limits Symbol fSCL TI tAA tBUF tHD:STA tLOW tHIGH tSU:STA tHD:DAT tSU:DAT tR tF tSU:STO tDH Parameter Min. Max. Units SCL Clock Frequency Noise Suppression Time Constant at SCL, SDA Inputs SCL Low to SDA Data Out Valid Time the Bus Must Be Free Before a New Transmission Can Start Start Condition Hold Time Clock Low Period Clock High Period Start Condition Setup Time (for a Repeated Start Condition) Data In Hold Time Data In Setup Time SDA and SCL Rise Time SDA and SCL Fall Time Stop Condition Setup Time Data Out Hold Time 0 100 100 KHz ns 0.3 4.7 3.5 µs µs 4.0 4.7 4.0 4.7 µs µs µs µs 0 250 µs ns µs ns µs ns 1 300 4.7 300 3846 PGM T07 POWER-UP TIMING(4) Symbol Parameter Max. Units tPUR tPUW Power-up to Read Operation Power-up to Write Operation 1 5 ms ms 3846 PGM T08 Notes: (4) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters are periodically sampled and not 100% tested. 10 X24164 Bus Timing tHIGH tF tLOW tR SCL tSU:STA tHD:STA tHD:DAT tSU:DAT tSU:STO SDA IN tAA tDH tBUF SDA OUT 3846 FHD F05 Write Cycle Limits Symbol Parameter Min. TWR(6) Write Cycle Time Typ.(5) Max. Units 5 10 ms 3846 PGM T09 The write cycle time is the time from a valid stop condition of a write sequence to the end of the internal erase/program cycle. During the write cycle, the X24164 bus interface circuits are disabled, SDA is allowed to remain high, and the device does not respond to its slave address. Write Cycle Timing SCL ACK 8th BIT SDA WORD n tWR STOP CONDITION START CONDITION 3846 FHD F06 Notes: (5) Typical values are for TA = 25°C and nominal supply voltage (5V). (6) tWR is the minimum cycle time to be allowed from the system perspective unless polling techniques are used. It is the maximum time the device requires to automatically complete the internal write operation. Guidelines for Calculating Typical Values of Bus Pull-Up Resistors WAVEFORM 120 RESISTANCE (KΩ) SYMBOL TABLE RMIN = 100 80 VCC MAX RMAX = IOL MIN =1.8KΩ tR CBUS MAX. RESISTANCE 60 40 20 MIN. RESISTANCE 0 0 20 40 60 INPUTS OUTPUTS Must be steady Will be steady May change from Low to High Will change from Low to High May change from High to Low Will change from High to Low Don’t Care: Changes Allowed Changing: State Not Known N/A Center Line is High Impedance 80 100 120 BUS CAPACITANCE (pF) 3846 FHD F18 11 X24164 PACKAGING INFORMATION 8-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P 0.430 (10.92) 0.360 (9.14) 0.092 (2.34) DIA. NOM. 0.255 (6.47) 0.245 (6.22) PIN 1 INDEX PIN 1 0.300 (7.62) REF. HALF SHOULDER WIDTH ON ALL END PINS OPTIONAL 0.140 (3.56) 0.130 (3.30) SEATING PLANE 0.020 (0.51) 0.015 (0.38) 0.062 (1.57) 0.058 (1.47) 0.150 (3.81) 0.125 (3.18) 0.020 (0.51) 0.016 (0.41) 0.110 (2.79) 0.090 (2.29) 0.015 (0.38) MAX. 0.060 (1.52) 0.020 (0.51) 0.325 (8.25) 0.300 (7.62) 0° 15° TYP. 0.010 (0.25) NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 3926 FHD F01 12 X24164 PACKAGING INFORMATION 8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S 0.150 (3.80) 0.158 (4.00) 0.228 (5.80) 0.244 (6.20) PIN 1 INDEX PIN 1 0.014 (0.35) 0.019 (0.49) 0.188 (4.78) 0.197 (5.00) (4X) 7° 0.053 (1.35) 0.069 (1.75) 0.004 (0.19) 0.010 (0.25) 0.050 (1.27) 0.010 (0.25) X 45° 0.020 (0.50) 0° – 8° 0.0075 (0.19) 0.010 (0.25) 0.027 (0.683) 0.037 (0.937) NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESIS IN MILLIMETERS) 3926 FHD F22 13 X24164 ORDERING INFORMATION X24164 X X -X VCC Range Blank = 4.5V to 5.5V 3 = 3.0V to 5.5V 2.7 = 2.7V to 5.5V Device Temperature Range Blank = 0°C to +70°C I = –40°C to +85°C M = –55°C to +125°C Package P = 8-Lead Plastic DIP S8 = 8-Lead SOIC Part Mark Convention X24164 X P = 8-Lead Plastic DIP S8 = 8-Lead SOIC X Blank = 4.5V to 5.5V, 0°C to +70°C I = 4.5V to 5.5V, –40°C to +85°C D = 3.0V to 5.5V, 0°C to +70°C E = 3.0V to 5.5V, –40°C to +85°C F = 2.7V to 5.5V, 0°C to +70°C G = 2.7V to 5.5V, –40°C to +85°C LIMITED WARRANTY Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice. Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, licenses are implied. U.S. PATENTS Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481; 4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967; 4,883, 976. Foreign patents and additional patents pending. LIFE RELATED POLICY In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection and correction, redundancy and back-up features to prevent such an occurence. Xicor's products are not authorized for use in critical components in life support devices or systems. 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. 14