Preliminary Information Pin 7 No Connect X24022 X24022 2K 256 x 8 Bit Serial E2PROM FEATURES DESCRIPTION • • The X24022 is a CMOS 2048 bit serial E2PROM, internally organized 256 x 8. The X24022 features a serial interface and software protocol allowing operation on a simple two wire bus. Three address inputs allow up to eight devices to share a common two wire bus. • • • • • 2.7V to 5.5V Power Supply Low Power CMOS —Active Current Less Than 1 mA —Standby Current Less Than 50 µA Internally Organized 256 x 8 Self Timed Write Cycle —Typical Write Cycle Time of 5 ms 2 Wire Serial Interface —Bidirectional Data Transfer Protocol Four Byte Page Write Operation —Minimizes Total Write Time Per Byte High Reliability —Endurance: 100,000 Cycles Per Byte —Data Retention: 100 Years Xicor E2PROMs are designed and tested for applications requiring extended endurance. Inherent data retention is greater than 100 years. The X24022 is available in eight pin DIP and SOIC packages. FUNCTIONAL DIAGRAM (8) VCC (4) VSS H.V. GENERATION TIMING & CONTROL START CYCLE (5) SDA START STOP LOGIC CONTROL LOGIC (6) SCL SLAVE ADDRESS REGISTER +COMPARATOR LOAD (3) A2 (2) A1 INC E2PROM 64 X 32 XDEC WORD ADDRESS COUNTER (1) A0 R/W YDEC 8 CK PIN DATA REGISTER DOUT DOUT ACK 3848 FHD F01 © Xicor, 1991 Patents Pending 3848-1 1 Characteristics subject to change without notice X24022 PIN DESCRIPTIONS PIN CONFIGURATION Serial Clock (SCL) The SCL input is used to clock all data into and out of the device. DIP/SOIC Serial Data (SDA) SDA is a bidirectional pin used to transfer data into and out of the device. It is an open drain output and may be wire-ORed with any number of open drain or open collector outputs. A0 1 A1 2 A2 3 VSS 4 X24022 8 VCC 7 NC 6 SCL 5 SDA 3848 FHD F02 An open drain output requires the use of a pull-up resistor. For selecting typical values, refer to the Guidelines for Calculating Typical Values of Bus Pull-Up Resistors graph. PIN NAMES Symbol A0–A2 SDA SCL NC VSS VCC Address (A0, A1, A2) The address inputs are used to set the least significant three bits of the seven bit slave address. These inputs can be static or actively driven. If used statically they must be tied to VSS or VCC as appropriate. If actively driven, they must be driven to VSS or to VCC. Description Address Inputs Serial Data Serial Clock No Connect Ground +5V 3848 PGM T01 2 X24022 DEVICE OPERATION Clock and Data Conventions The X24022 supports a bidirectional bus oriented protocol. The protocol defines any device that sends data onto the bus as a transmitter, and the receiving device as the receiver. The device controlling the transfer is a master and the device being controlled is the slave. The master will always initiate data transfers, and provide the clock for both transmit and receive operations. Therefore, the X24022 will be considered a slave in all applications. Data states on the SDA line can change only during SCL LOW. SDA state changes during SCL HIGH are reserved for indicating start and stop conditions. Refer to Figures 1 and 2. Start Condition All commands are preceded by the start condition, which is a HIGH to LOW transition of SDA when SCL is HIGH. The X24022 continuously monitors the SDA and SCL lines for the start condition and will not respond to any command until this condition has been met. Figure 1. Data Validity SCL SDA DATA STABLE DATA CHANGE 3 3848 FHD F06 X24022 Stop Condition The X24022 will respond with an acknowledge after recognition of a start condition and its slave address. If both the device and a write operation have been selected, the X24022 will respond with an acknowledge after the receipt of each subsequent eight bit word. All communications must be terminated by a stop condition, which is a LOW to HIGH transition of SDA when SCL is HIGH. The stop condition is also used by the X24022 to place the device into the standby power mode after a read sequence. A stop condition can only be issued after the transmitting device has released the bus. In the read mode the X24022 will transmit eight bits of data, release the SDA line and monitor the line for an acknowledge. If an acknowledge is detected and no stop condition is generated by the master, the X24022 will continue to transmit data. If an acknowledge is not detected, the X24022 will terminate further data transmissions. The master must then issue a stop condition to return the X24022 to the standby power mode and place the device into a known state. Acknowledge Acknowledge is a software convention used to indicate successful data transfers. The transmitting device will release the bus after transmitting eight bits. During the ninth clock cycle the receiver will pull the SDA line LOW to acknowledge that it received the eight bits of data. Refer to Figure 3. Figure 2. Definition of Start and Stop SCL SDA START BIT STOP BIT 3848 FHD F07 Figure 3. Acknowledge Response From Receiver SCL FROM MASTER 1 8 9 DATA OUTPUT FROM TRANSMITTER DATA OUTPUT FROM RECEIVER START ACKNOWLEDGE 3848 FHD F08 4 X24022 DEVICE ADDRESSING Following the start condition, the X24022 monitors the SDA bus comparing the slave address being transmitted with its slave address (device type and state of A0, A1 and A2 inputs). Upon a correct compare the X24022 outputs an acknowledge on the SDA line. Depending on the state of the R/W bit, the X24022 will execute a read or write operation. Following a start condition the master must output the address of the slave it is accessing. The most significant four bits of the slave address are the device type identifier (see Figure 4). For the X24022 this is fixed as 1010[B]. Figure 4. Slave Address WRITE OPERATIONS DEVICE TYPE IDENTIFIER 1 0 1 Byte Write 0 A2 A1 A0 DEVICE ADDRESS For a write operation, the X24022 requires a second address field. This address field is the word address, comprised of eight bits, providing access to any one of the 256 words of memory. Upon receipt of the word address the X24022 responds with an acknowledge, and awaits the next eight bits of data, again responding with an acknowledge. The master then terminates the transfer by generating a stop condition, at which time the X24022 begins the internal write cycle to the nonvolatile memory. While the internal write cycle is in progress the X24022 inputs are disabled, and the device will not respond to any requests from the master. Refer to Figure 5 for the address, acknowledge and data transfer sequence. R/W 3848 FHD F09 The next three significant bits address a particular device. A system could have up to eight X24022 devices on the bus (see Figure 10). The eight addresses are defined by the state of the A0, A1 and A2 inputs. The last bit of the slave address defines the operation to be performed. When set to one a read operation is selected, when set to zero a write operation is selected. Figure 5. Byte Write S T BUS ACTIVITY: A R MASTER T SDA LINE BUS ACTIVITY: X24022 WORD ADDRESS SLAVE ADDRESS S T O P DATA S P A C K A C K A C K 3848 FHD F10 5 X24022 Page Write Flow 1. ACK Polling Sequence The X24022 is capable of an four byte page write operation. It is initiated in the same manner as the byte write operation, but instead of terminating the write cycle after the first data word is transferred, the master can transmit up to three more words. After the receipt of each word, the X24022 will respond with an acknowledge. WRITE OPERATION COMPLETED ENTER ACK POLLING ISSUE START After the receipt of each word, the two low order address bits are internally incremented by one. The high order five bits of the address remain constant. If the master should transmit more than four words prior to generating the stop condition, the address counter will “roll over” and the previously written data will be overwritten. As with the byte write operation, all inputs are disabled until completion of the internal write cycle. Refer to Figure 6 for the address, acknowledge and data transfer sequence. ISSUE SLAVE ADDRESS AND R/W = 0 ACK RETURNED? Acknowledge Polling ISSUE STOP NO YES The disabling of the inputs, during the internal write operation, can be used to take advantage of the typical 5 ms write cycle time. Once the stop condition is issued to indicate the end of the host’s write operation the X24022 initiates the internal write cycle. ACK polling can be initiated immediately. This involves issuing the start condition followed by the slave address for a write operation. If the X24022 is still busy with the write operation no ACK will be returned. If the X24022 has completed the write operation an ACK will be returned and the master can then proceed with the next read or write operation (See Flow 1). NEXT OPERATION A WRITE? NO YES ISSUE BYTE ADDRESS ISSUE STOP PROCEED PROCEED 3848 FHD F11 Figure 6. Page Write S T BUS ACTIVITY: A R MASTER T SDA LINE BUS ACTIVITY: X24022 WORD ADDRESS (n) SLAVE ADDRESS DATA n DATA n+1 S T O P DATA n+3 S P A C K A C K A C K A C K A C K NOTE: In this example n = xxxx 0000(B); x = 1 or 0 3848 FHD F12 6 X24022 during the next eight clock cycles. The read operation is terminated by the master; by not responding with an acknowledge and by issuing a stop condition. Refer to Figure 7 for the sequence of address, acknowledge and data transfer. READ OPERATIONS Read operations are initiated in the same manner as write operations with the exception that the R/W bit of the slave address is set to a one. There are three basic read operations: current address read, random read and sequential read. Random Read Random read operations allow the master to access any memory location in a random manner. Prior to issuing the slave address with the R/W bit set to one, the master must first perform a “dummy” write operation. The master issues the start condition, and the slave address followed by the word address it is to read. After the word address acknowledge, the master immediately reissues the start condition and the slave address with the R/W bit set to one. This will be followed by an acknowledge from the X24022 and then by the eight bit word. The read operation is terminated by the master; by not responding with an acknowledge and by issuing a stop condition. Refer to Figure 8 for the address, acknowledge and data transfer sequence. It should be noted that the ninth clock cycle of the read operation is not a “don’t care.” To terminate a read operation, the master must either issue a stop condition during the ninth cycle or hold SDA HIGH during the ninth clock cycle and then issue a stop condition. Current Address Read Internally the X24022 contains an address counter that maintains the address of the last word accessed, incremented by one. Therefore, if the last access (either a read or write) was to address n, the next read operation would access data from address n + 1. Upon receipt of the slave address with R/W set to one, the X24022 issues an acknowledge and transmits the eight bit word Figure 7. Current Address Read S T BUS ACTIVITY: A R MASTER T SDA LINE SLAVE ADDRESS DATA S S T O P P A C K BUS ACTIVITY: X24022 3848 FHD F13 Figure 8. Random Read S T BUS ACTIVITY: A R MASTER T SDA LINE BUS ACTIVITY: X24022 SLAVE ADDRESS S T A R T WORD ADDRESS n S SLAVE ADDRESS DATA n S A C K A C K S T O P P A C K 3848 FHD F14 7 X24022 Sequential Read The data output is sequential, with the data from address n followed by the data from n + 1. The address counter for read operations increments all address bits, allowing the entire memory contents to be serially read during one operation. At the end of the address space (address 255), the counter “rolls over” to address 0 and the X24022 continues to output data for each acknowledge received. Refer to Figure 9 for the address, acknowledge and data transfer sequence. Sequential Read can be initiated as either a current address read or random access read. The first word is transmitted as with the other modes, however, the master now responds with an acknowledge, indicating it requires additional data. The X24022 continues to output data for each acknowledge received. The read operation is terminated by the master, by not responding with an acknowledge and by issuing a stop condition. Figure 9. Sequential Read BUS ACTIVITY: MASTER SLAVE ADDRESS A C K A C K S T O P A C K P SDA LINE BUS ACTIVITY: X24022 A C K DATA n+1 DATA n DATA n+2 DATA n+x 3848 FHD F15 Figure 10. Typical System Configuration VCC PULL-UP RESISTORS SDA SCL MASTER TRANSMITTER/ RECEIVER SLAVE RECEIVER SLAVE TRANSMITTER/ RECEIVER MASTER TRANSMITTER MASTER TRANSMITTER/ RECEIVER 3848 FHD F16 8 X24022 ABSOLUTE MAXIMUM RATINGS* Temperature Under Bias .................. –65°C to +135°C Storage Temperature ....................... –65°C to +150°C Voltage on any Pin with Respect to VSS ............................... –1.0V to +7V D.C. Output Current ............................................ 5 mA Lead Temperature (Soldering, 10 Seconds) ............................. 300°C *COMMENT Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and the functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. RECOMMENDED OPERATING CONDITIONS Temperature Min. Max. Commercial Industrial Military 0°C –40°C –55°C 70°C +85°C +125°C Supply Voltage Limits X24022 X24022-3 X24022-2.7 4.5V to 5.5V 3V to 5.5V 2.7V ± 5.5V 3848 PGM T02 3848 PGM T03 D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified) Limits Symbol Parameter Min. Max. Units lCC1 Power Supply Current (read) 1 mA lCC2 ISB(1) Power Supply Current (write) Standby Current 2 50 µA ISB(2) Standby Current 30 µA ILI ILO VlL(2) VIH(2) VOL Input Leakage Current Output Leakage Current Input Low Voltage Input High Voltage Output Low Voltage µA µA V V V 10 10 –1.0 VCC x 0.3 VCC x 0.7 VCC + 0.5 0.4 Test Conditions SCL = VCC x 0.1/VCC x 0.9 Levels @ 100 KHz, SDA = Open, All Other Inputs = GND or VCC – 0.3V SCL = SDA = VCC – 0.3V, All Other Inputs = GND or VCC, VCC = 5.5V SCL = SDA = VCC – 0.3V, All Other Inputs = GND or VCC, VCC= 3V VIN = GND to VCC VOUT = GND to VCC IOL = 3 mA 3848 PGM T04 CAPACITANCE TA = 25°C, f = 1.0 MHz, VCC = 5V Symbol CI/O(3) CIN(3) Test Max. Input/Output Capacitance (SDA) Input Capacitance (A0, A1, A2, SCL) 8 6 Units Conditions pF pF VI/O = 0V VIN = 0V 3848 PGM T06 Notes: (1) Must perform a stop command prior to measurement. (2) VIL min. and VIH max. are for reference only and are not tested. (3) This parameter is periodically sampled and not 100% tested. 9 X24022 A.C. CONDITIONS OF TEST Input Pulse Levels Input Rise and Fall Times Input and Output Timing Levels EQUIVALENT A.C. LOAD CIRCUIT VCC x 0.1 to VCC x 0.9 5.0V 1533Ω 10 ns Output VCC x 0.5 100pF 3848 PGM T02 3848 FHD F18 A.C. CHARACTERISTICS LIMITS (Over recommended operating conditions unless otherwise specified) Read & Write Cycle Limits Symbol Parameter Min. fSCL TI tAA tBUF tHD:STA tLOW tHIGH tSU:STA tHD:DAT tSU:DAT tR tF tSU:STO tDH SCL Clock Frequency Noise Suppression Time Constant at SCL, SDA Inputs SCL Low to SDA Data Out Valid Time the Bus Must Be Free Before a New Transmission Can Start Start Condition Hold Time Clock Low Period Clock High Period Start Condition Setup Time Data In Hold Time Data In Setup Time SDA and SCL Rise Time SDA and SCL Fall Time Stop Condition Setup Time Data Out Hold Time 0 0.3 4.7 4.0 4.7 4.0 4.7 0 250 Max. Units 100 100 3.5 KHz ns µs µs µs µs µs µs µs ns µs ns µs ns 1 300 4.7 300 3848 PGM T08 POWER-UP TIMING Symbol tPUR(4) tPUW(4) Parameter Max. Units Power-Up to Read Operation Power-Up to Write Operation 1 5 ms ms 3848 PGM T09 Bus Timing tHIGH tF tLOW tR SCL tSU:STA tHD:STA tHD:DAT tSU:DAT tSU:STO SDA IN tAA tDH tBUF SDA OUT 3848 FHD F04 Notes: (4) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters are periodically sampled and not 100% tested. 10 X24022 WRITE CYCLE LIMITS Symbol Parameter Min. tWR(6) Write Cycle Time Typ.(5) Max. Units 5 10 ms 3848 PGM T08 The write cycle time is the time from a valid stop condition of a write sequence to the end of the internal erase/program cycle. During the write cycle, the X24022 bus interface circuits are disabled, SDA is allowed to remain high, and the device does not respond to its slave address. Write Cycle Timing SCL SDA ACK 8th BIT WORD n tWR STOP CONDITION START CONDITION X24022 ADDRESS 3848 FHD F05 Notes: (5) Typical values are for TA = 25°C and nominal supply voltage (5V) (6) tWR is the minimum cycle time from the system perspective when polling techniques are not used. It is the maximum time the device requires to perform the internal write operation. Guidelines for Calculating Typical Values of Bus Pull-Up Resistors SYMBOL TABLE WAVEFORM RESISTANCE (KΩ) 120 RMIN = 100 80 VCC MAX IOL MIN RMAX = tR 40 20 MIN. RESISTANCE 0 0 20 40 60 OUTPUTS Must be steady Will be steady May change from Low to High Will change from Low to High May change from High to Low Will change from High to Low Don’t Care: Changes Allowed Changing: State Not Known N/A Center Line is High Impedance =1.8KΩ CBUS MAX. RESISTANCE 60 INPUTS 80 100 120 BUS CAPACITANCE (pF) 3848 FHD F17 11 X24022 NOTES 12 X24022 PACKAGING INFORMATION 8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S 8-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P 0.430 (10.92) 0.360 (9.14) 0.092 (2.34) DIA. NOM. 0.150 (3.80) 0.158 (4.00) 0.255 (6.47) 0.245 (6.22) 0.228 (5.80) 0.244 (6.20) PIN 1 INDEX PIN 1 INDEX PIN 1 PIN 1 0.300 (7.62) REF. 0.060 (1.52) 0.020 (0.51) 0.014 (0.35) 0.019 (0.49) HALF SHOULDER WIDTH ON ALL END PINS OPTIONAL 0.188 (4.78) 0.197 (5.00) 0.140 (3.56) 0.130 (3.30) SEATING PLANE 0.020 (0.51) 0.015 (0.38) 0.062 (1.57) 0.058 (1.47) 0.150 (3.81) 0.125 (3.18) 0.053 (1.35) 0.069 (1.75) 0.020 (0.51) 0.016 (0.41) 0.110 (2.79) 0.090 (2.29) 0.015 (0.38) MAX. (4X) 7° 0.004 (0.19) 0.010 (0.25) 0.050 (1.27) 0.010 (0.25) X 45° 0.020 (0.50) 0.325 (8.25) 0.300 (7.62) 0° – 8° 0.0075 (0.19) 0.010 (0.25) TYP. 0.010 (0.25) 0° 15° 0.027 (0.683) 0.037 (0.937) NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 13 X24022 ORDERING INFORMATION X24022 P T -V VCC Limits Blank = 4.5V to 5.5V 3 = 3V to 5.5V 2.7 = 2.7V to 5.5V Device Temperature Range Blank = Commercial = 0°C to +70°C I = Industrial = –40°C to +85°C M = Military = –55°C to +125°C Package P = 8-Lead Plastic DIP S = 8-Lead SOIC Part Mark Convention X24022 Blank = 8-Lead SOIC P = 8-Lead Plastic DIP S = 8-Lead SOIC X X Blank = 4.5V to 5.5V, 0°C to +70°C I = 4.5V to 5.5V, –40°C to +85°C D = 3V to 5.5V, 0°C to +70°C E = 3V to 5.5V, –40°C to +85°C F = 2.7V to 5.5V, 0°C to +70°C G = 2.7V to 5.5V, –40°C to +85°C LIMITED WARRANTY Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice. Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, licenses are implied. U.S. PATENTS Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481; 4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967; 4,883, 976. Foreign patents and additional patents pending. LIFE RELATED POLICY In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection and correction, redundancy and back-up features to prevent such an occurence. Xicor's products are not authorized for use in critical components in life support devices or systems. 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. 14