ALLEN-BRADLEY 440K

Interlock Switches
Guard Locking Switches
Centurion
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119, IEC/
EN60947-5-1, ANSI B11.19, AS4024.1
Category
Cat. 1 Device per EN954-1
Dual channel interlocks suitable for
Cat. 3 or 4 systems
Approvals
CE marked for all applicable directives,
cULus, BG, and SUVA
Safety Contact
2 N.C. direct opening action
Designation/Utilization Cat.
AC (Ue)
(Ie)
DC
AC15
500V 250V 100V
1A 2A 5A
250V 0.5A 24V 2A
Max Switched Current/Volt/
Load
500V/500VA
The Centurion is a positive mode, thumbwheel operated machine
guard locking interlock switch that locks the guard closed until the
operator manually rotates the thumbwheel, retracting the shaft from
the guard door. The action of retracting the shaft initiates two
functions; it isolates the power to the machine while the guard is open
and, due to the operating principle, gives up to 20 seconds delay
before the guard can be opened.
Thermal Current (lth)
10A
Min Current
5V 5mA
Safety Contact Gap
>2mm (0.078in)
Auxiliary Contacts
1 N.C.
Alternative styles with longer shafts can increase the time delay by as
much as 50%. The Centurion is ideal for use on simple machines
with short, constant run down times. It is important that correct
installation and operation of the unit are followed to ensure that the
retractable shaft cannot be extended when the guard is open. For
machines with long or variable run down times or where frequent
access is required, solenoid locking switches such as the TLS-GD2
and Atlas 5 should be considered.
Shaft Movement to Achieve
Contact Operation
2mm (0.078in)
73013
Description
The Centurion has 2 safety (N.C.) contacts, 1 auxiliary (N.O.) contact
and 1 conduit entry (either M20 or quick disconnect).
EX and Pneumatic styles of the Centurion are also available; see the
Explosion Proof section on page 16-1 for more information.
Note: Additional safety measures (i.e., a shroud) should be used
to ensure the thumbwheel can only be accessed by fingertips.
Features
•
•
•
•
Rtd. Insulation Voltage
(Ui) 500V
Rtd. Impulse withstand Volt
(Uimp) 2500V
Case Material
Heavy duty die cast alloy
Locking shaft
Stainless Steel
Protection
IP66
Conduit Entry
1 x M20 or quick disconnect
Operating Temperature
-25°C to +80°C (-10°F to +176°F)
Mounting
2 x M4
Mechanical Life
1,000,000 operations
Electrical Life
1,000,000 operations
Weight
500g (1.20lbs)
Colour
Red
Note: The safety contacts of the Guardmaster switches are described as normally
closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the
machine able to be started.
Centurion Thumbwheel Operation
Manually operated time delay, allows for machine run down
Simple operation & installation
Robust die cast housing, ideal for heavy duty applications
Contacts, 2 N.C. & 1 N.O. (sealed to IP66)
Interlocking shaft is manually
retracted from the guard by
rotating the thumbwheel.
3-40
Interlock Switches
Guard Locking Switches
Centurion
Product Selection
Catalogue Number
Safety Contacts
Auxiliary Contacts
2 N.C.
BBM/MBB
1 N.O.
Type
M20 Conduit
Quick Disconnect
Right Hand
440K-B04025
440K-B04046
Left Hand
440K-B04026
440K-B04047
Right Hand Extended Bolt
440K-B04039
440K-B04048
Left Hand Extended Bolt
440K-B04040
440K-B04049
BBM
Recommended mating cable, 2m (6.5ft). See page 15-10 for details and
additional lengths.
889D-F8AB-2
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
Ø 20
(0.79)
36 (1.42)
86 (3.39)
15
(0.59)
6 (0.24)
Ø14
(0.55)
6
(0.24)
View from Side
16.5
(0.65)
14
(0.55)
24 (0.94)
35 (1.38)
View from Rear
30 (1.18) 64 (2.52)
View from End
98 (3.86)
LH Style
Front View
RH Style
Front View
40.5 (1.59)
Typical Wiring Diagrams
Safety Circuit 1
Safety Circuit 2
Auxiliary
22
12
21
34
11
33
2 N.C. + 1 N.O.
Connector Pinout
1
2
8
3
4
Terminal
1
11
7
12
7
6
21
6
5
5
22
4
33
3
34
8
Contact
N.C.
Contact Action
Contact Open
Contact Closed
Actuator withdrawal distance
from full insertion
2 N.C. + 1 N.O. (BBM)
N.C.
N.O.
24.5
11/12
21/22
33/34
2
0mm
Ground
3-41