ALLEN-BRADLEY 440A

Interlock Switches
Non contact Switches
Sentinel 1
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119,
IEC60947-5-1, ANSI B11.19, AS4024.1
Category
Cat. 3 per EN954-1
Approvals
CE marked for all applicable directives
Power Supply
24V AC/DC, 48V AC, 110V AC,
230V AC
Power Consumption
< 2VA
Internal Fuses
Power 250mA replaceable
N.C. Output 2A replaceable
Description
The Sentinel 1 is an electro-magnetically coded standalone Non
contact interlock. It operates without a safety relay while providing a
highly coded system to help prevent defeat of the switch by simple
magnets. Self-checking and monitoring functions are contained in the
switching unit which also has LED status indication.
The Sentinel 1 has 1 N.O. and 1 N.C. output and is supplied prewired. A replaceable fuse for overload protection is easily accessed by
removing the front of the switch with a security bit.
Features
•
•
•
•
•
Non contact actuation
Electro-magnetic coding
Standalone operation
Plastic box style housing (IP65)
Terminal connections
3-64
Operating Distance
Make 7mm (0.28in)
Break 10mm (0.39in)
Misalignment Tolerance
±5mm (0.2) make and break
Output Rating
B300, AC-15, 2A/250V AC
P300, DC-13, 2A/250V DC
Minimum Switching
Capability
10mA/10V
Indication LEDs
Green = Guard closed
Impulse Withstand Voltage
2500V
Operating Temperature
-25°C to +125°C (-13°F to +257°F)
Humidity
90% RH
Enclosure Protection
IP65 (NEMA 13)
Cable
0.75 sq. mm2 (18 AWG) 2 wire
PVC Jacket OD 7.5mm (.3in)
Case Material
Red reinforced ABS
Mounting
Any position
M4 mounting security screws included
Weight (not including cable)
Sensor Actuator
120g (0.26lbs) 39g (0.09lbs)
Electrical Life
100,000 at rated load
Mechanical Life
1,000,000 at no load
Vibration
10-55Hz, 1mm displacement
Shock
8g, 11ms half-sine
Interlock Switches
Non contact Switches
Sentinel 1
Product Selection
Safety Contacts
Auxiliary Contacts
Power Supply
24V AC/DC
48V AC
1 N.C.
1 N.O.
110V AC
230V AC
Connection
Catalogue Number
2m Cable
440N-N15017
4m Cable
440N-N15023
6m Cable
440N-N15021
12m Cable
440N-N15041
2m Cable
440N-N15028
2m Cable
440N-N15015
6m Cable
440N-N15027
2m Cable
440N-N15013
4m Cable
440N-N15024
12m Cable
440N-N15040
Note: Contacts are described with the guard door closed, that is, actuator in place. Switch is shipped complete with actuator.
Accessories
Page Number
Catalogue Number
Replacement Actuator
Description
—
440N-A15005
Replacement Fuse 2A
14-2
440A-A09197
Replacement Fuse 250mA
14-2
440A-A09196
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
Actuator
Switch
19
(0.75)
5 (0.2)
=
82 (3.23)
4
(0.16)
73 (2.87)
57 (2.24)
69 (2.72)
4.5 (0.18)
36 (1.42)
=
38 (1.5)
7 (0.28)
4.5 (0.18) = =
Mounting
2 x M4
50
(1.97)
5 (0.2)
19
(0.75)
3-65
Interlock Switches
Non contact Switches
Sentinel 1
Typical Wiring Diagrams
Sentinel 1 Sensor
Red
+ Supply
Voltage
-
Blue
Safety
N.C.
Fuse
Externally
Black
White
Yellow
Auxiliary
N.O.
Green
Application Details
Operating Principle
On presenting the actuator to the switch, the highintensity electromagnetic field together with a
resonant frequency signal causes the contacts to
close. On removing the actuator, (opening the door)
the safety contacts open, isolating the machine. The
switch can not be overridden by magnets, tools, etc.
Actuator Approaches
✔
✔
✔
3-66
Interlock Switches
Non contact Switches
Sentinel 1
Application Details—Installation Mounting
Hinge Guards
Door stop
Double Hinge Guards
Switch
≤25mm
Switch
2mm Minimum
5mm Maximum
Switch
Actuator
Actuator
Guard
Actuator
Sliding Guards
Lift Off Guards
2mm Minimum
5mm Maximum
Switch
2mm Minimum
5mm Maximum
Switch
Actuator
Switch
Guard
Actuator
Guard
Actuator
Door stop
3-67