OMRON XW2D-34G6

Slim Connector-Terminal Block Conversion Units
XW2D
CSM_XW2D_DS_E_1_2
New Slim Connector-Terminal Block
Conversion Units.
• Mounting area reduced by 35% (in comparison with
40-pole XW2B Units) to contribute to downsizing
control panels and automatic equipment.
• Fallout prevention for terminal screws.
• Round or forked crimp terminals can be used.
• Mount to DIN Track or via screws.
Unique DIN Track lock can maintain open status
during DIN Track attachment and removal.
• Terminal cover can be locked open.
• Screw terminals are arranged by color in groups
of five to simplify counting terminal numbers.
Ordering Information
Connectors
Mounted Connector
No. of
poles
XG4A
MIL Connectors
XG4C
MIL Connectors
MR Sockets
MR Plugs
Model
Dimension
A
Dimension
B
Mounted Connector model
Cable Connector model
20
XW2D-20G6
79
57
XG4A-2031
XG4M-2030-T
34
XW2D-34G6
128
100
XG4A-3431
XG4M-3430-T
XW2D-40G6
149
110
XG4A-4031
XG4M-4030-T
XW2D-40G6-RF *1
149
110
XG4A-4031
XG4M-4030-T
XW2D-40G6-RM *2
149
110
XG4A-4031
XG4M-4030-T
50
XW2D-50G6
184
144
XG4A-5031
XG4M-5030-T
20
XW2D-20C6
79
57
XG4C-2031
XG4M-2030-U
34
XW2D-34C6
128
100
XG4C-3431
XG4M-3430-U
40
XW2D-40C6
149
110
XG4C-4031
XG4M-4030-U
50
XW2D-50C6
184
144
XG4C-5031
XG4M-5030-U
20
XW2D-20X6
79
57
MR-20RFD2 *3
MR-20M *3
34
XW2D-34X6
128
100
MR-34RFD2 *3
MR-34M *3
50
XW2D-50X6
184
144
MR-50RFD2 *3
MR-50M *3
20
XW2D-20Y6
79
57
MR-20RMD2 *3
MR-20F*3
34
XW2D-34Y6
128
100
MR-34RMD2 *3
MR-34F *3
50
XW2D-50Y6
184
144
MR-50RMD2 *3
MR-50F *3
40
*1. This model has built-in bleeder resistance and is used for inputs to Units with Fujitsu connectors, i.e., the CJ1W-ID231/-ID261/-MD261.
*2. This model has built-in bleeder resistance and is used for inputs on Units with MIL connectors, i.e., the CJ1W-ID232/-ID262/-MD263/-MD563.
*3. The MR Connector is made by Honda Tsushin Kogyo.
Accessories (Order Separately)
Connecting Cables for Connector-Terminal Block Conversion Units
Refer to the XW2Z Datasheet.
Ratings and Specifications
Rated current
1A
Rated voltage
125 VAC, 24 VDC
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
500 VAC for 1 min (leakage current: 1 mA max.)
Ambient operating tem0 to 55°C
perature
1
XW2D
Dimensions
(Unit: mm)
XW2D-@@G6
Mounted Connector: XG4A MIL Connector
Wiring Diagram
(Example for Terminal Block with 50 Poles)
XG4A MIL Connector
A
B
Two, 4.5 dia.
Mounted Connector
(39.1)
17.6
6 40
7
4
6
46 48 50
1
3
5
45 47 49
Triangular mark
39
7
(4.5)
DIN Track lock
2
A1 A2 A3
5.8
1.2
A23
A24
A25
M3
B1 B2 B3
B23
B24
B25
Terminal Block
Note: For all models, the odd-numbered pins on the Connector correspond to row A on the terminal block and the
even-numbered pins on the Connector correspond to
row B on the terminal block.
7
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.
XW2D-40G6-RF
XW2D-40G6-RM
Connector (XG4A-4031)
Connector (XG4A-4031)
Connector
pin No.
2
4
6
8 10 12
1
3
5
7
9
14 16 18
Connector
pin No.
20 22 24 26 28 30 32 34 36 38 40
11 13 15 17 19
21 23 25 27 29
31 33 35 37 39
4
6
8
10 12
14 16
1
3
5
7
9
18 20 22 24
26 28 30 32 34 36 38 40
11 13 15
17 19 21 23
25 27 29 31 33 35 37 39
A1 A2
A3
A4
A5 A6
Triangular
mark
Triangular
mark
Terminal No.
2
A1 A2
B1 B2
A3
B3
A4
B4
A5 A6
B5 B6
A7
A8 A9 A10
B7
B8 B9
A11
B10
A12
B11
A13
B12
A14
B13
A15
B14
A16
B15
A17
B16
A18
B17
A19
B18
Terminal No.
A20
B19
B1 B2
B20
B3
B4
A7
B5 B6
B7
Note: The dimensions shown here are the same as the XW2D-40G6.
A11
B10
A12
B11
A13
B12
A14
B13
A15
B14
A16
B15
A17
B16
A18
B17
A19
B18
A20
B19
B20
Note: The dimensions shown here are the same as the XW2D-40G6.
XW2D-@@C6
Mounted Connector: XG4C MIL Connector
Wiring Diagram
(Example for Terminal Block with 50 Poles)
XG4C MIL Connector
Two,4.5 dia.
(21.1)
B
Mounted Connector
2
4
6
46 48 50
1
3
5
45 47 49
A1 A2 A3
A23 A24 A25
17.6
6 40
7
DIN Track lock
B8 B9
A10
Terminal Block
Terminal Block
A
A8 A9
(4.5)
Triangular
mark
39
7
5.8
1.2
M3
B1 B2 B3
B23 B24 B25
Terminal Block
7
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.
Note: For all models, the odd-numbered pins on the Connector correspond to row A on the terminal block and the
even-numbered pins on the Connector correspond to
row B on the terminal block.
2
XW2D
XW2D-@@X6
Mounted Connector: MR Socket
Wiring Diagram
(Example for Terminal Block with 50 Poles)
A
B
Two, 4.5 dia.
(28.2)
17.6
Mounted Connector
33 34 35
6 40
7
DIN track lock
48 49 50
19 20
1
2
3
1
3
5
32
16 17 18
39
(4.5)
7
5.8
1.2
M3
2
7
4
45 47 49
17 19
46 48 50
16 18 20
6
Terminal Block
Note: There is only one DIN Track lock located in the center of the Connector for a 20-pole Unit.
Note: Connector pin numbers correspond 1-to-1 to terminal
block numbers on all models.
XW2D-@@Y6
Mounted Connector: MR Plug
Wiring Diagram
(Example for Terminal Block with 50 Poles)
A
B
Two, 4.5 dia.
(25.9)
17.6
Mounted Connector
1
2
6 40
16 17 18
3
19 20
32
48 49 50
33 34 35
7
DIN Track lock
39
(4.5)
7
5.8
1.2
M3
1
3
2
7
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.
5
4
17 19
6
16 18
45 47 49
20
46 48 50
Terminal Block
Note: Connector pin numbers correspond 1-to-1 to terminal
block numbers on all models.
3
XW2D
Safety Precautions
Precautions for Correct Use
● Wiring
● Mounting Units to and Removing Units from DIN Track
• Always turn OFF the power supply before wiring.
Otherwise, cables or other conductors can short the terminals and cause the Unit to fail.
• Do not connect or disconnect Connectors with the power
turned ON. Otherwise, it may cause malfunctions.
• XW2D Connector-Terminal Block Conversion Units can be
mounted side-to-side on DIN Track.
• Secure both ends of the XW2D with End Plates.
• When removing the Unit from a DIN Track, insert a flat-head
screwdriver into the slider and pull the lock out.
● Wiring Terminal Blocks
Using Crimp Terminals
(With a Terminal Block with M3 Screws)
Round crimp terminals
Forked crimp terminals
3.2 mm dia.
3.2 mm 5.8 mm max.
5.8 mm max.
Applicable crimp terminals
Applicable wires
Round crimp terminals
1.25-3
AWG 22 to 16
(0.30 to 1.25 mm2)
Forked crimp terminals
1.25Y-3
AWG 22 to 16
(0.30 to 1.25 mm2)
● Terminal Screw Tightening Torque
● Handling M3 Screw and Round Terminals
Raise the M3 screw with a Phillips screwdriver as shown in diagram (1) and slide the screw toward you to keep the space
open. Follow the steps in diagrams (1) and (2) below when using round crimp terminals.
Use a tightening torque of 0.7 N·m when connecting wires or
crimp terminals to the terminal block.
A
B
4
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.