Solid State Relay G3S/G3SD Ultra-small Relay Breaks up to 1 A • Ultra-small, dual in-line package (DIP) SSR. • Terminals compatible with G6B Electromagnetic Relay’s. Mix with G6Bs as the application requires. • Close side-by-side mounting possible. In addition, heat sink dedicated to this mounting style also available. • Both AC- and DC-load versions available. • High isolation of 2,500 VAC between input and output freeing inputs from noise surge generated in the load. • Approved by UL and CSA. Ordering Information To order: Select the part number and add the desired input voltage (Ex: G3SD-Z01P-PD-US DC12) Isolation Phototriac Zero cross function No Indicator No Photocoupler Rated output load Rated input voltage (applicable output load) 1 A at 100 to 240 VAC (1 A at 75 to 264 VAC) (see note 1) 5 VDC 1.2 A at 100 to 240 VAC (1.2 A at 75 to 264 VAC) (see note 1) 5 VDC 1 A at 4 to 24 VDC (1 A at 3 to 26 VDC) (see note 2) 5 VDC 1.1 A at 4 to 24 VDC (1.1 A at 3 to 26 VDC) (see note 2) 5 VDC Model G3S-201PL-US 12 VDC 24 VDC G3S-201PL-PD-US 12 VDC 24 VDC G3SD-Z01P-US 12 VDC 24 VDC G3SD-Z01P-PD-US 12 VDC 24 VDC Note: 1. Product is labelled “250 VAC” 2. Product is labelled “24 VDC” ■ Accessories (Order Separately) Heat Sink Heat Sink Y92B-S08N See Dimension for details. Connecting Socket Connecting socket P6D-04P See Dimensions for details. Solid State Relay G3S/G3SD 397 Specifications ■ Ratings (at an Ambient Temperature of 25°C) Input Rated voltage Operating voltage Impedance G3S-201PL/201PL-PD Voltage level G3S-Z01PL/Z01P-PD 4 to 6 VDC 450 Ω±20% 12 VDC 9.6 to 14.4 VDC 1.1 κΩ±20% 1.5 kΩ±20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2.2 κΩ±20% 2.8 kΩ±20% 19.2 VDC max. 5VDC 630 Ω±20% Must operate 4 VDC max, Must release 1 VDC min. Output Model Applicable load Rated load voltage G3S-201PL Rated load voltage range 75 to 264 VAC 0.1 to 1A 4 to 24 VDC 3 to 26 VDC 0.01 to 1A G3S-201PL-PD G3SD-Z01PL Load current 100 to 240 VAC Inrush current 15 A (60 Hz, 1 cycle) 0.1 to 1.2 A G3SD-Z01PL-PD 3 A (10 ms) 0.01 to 1.1 A ■ Characteristics Item G3S-201PL/201PL-PD G3SD-Z01PL/Z01P-PD Operate time 1 ms max. Release time 1/2 of load power source cycle + 1 ms. max. Output ON voltage drop 1.6 V (RMS) max. 1.5 V max. Leakage current 2 mA max. 0.1 mA max. (at 26 VDC) Insulation resistance 100 MΩ min. (500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: -30°C to 80°C (with no icing or condensation) Storage: -30°C to 100°C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Approved standards UL File No. E64562/CSA File No. LR35535 Weight Approx. 13 g 398 Solid State Relay G3S/G3SD 1 ms. max. Engineering Data Load Current vs. Ambient Temperature Characteristics Inrush Current Resistivity Inrush current (A. Peak) G3S-201PL-PD G3SD-Z01P-PD Load current (A) G3S-201PL G3SD-Z01P Inrush current (A. Peak) Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3S-201PL G3S-201PL-PD Ambient temperature (°C) G3SD-Z01P G3SD-Z01P-PD Energized time (ms) Energized time (ms) Dimensions Note: All units are in millimeters unless otherwise indicated. G3S/G3SD PCB Dimensions (Bottom View) 10 max. 20 max. Four, 1.1 dia. holes 2.54 16.5 max. 16 max. 2.54 7.62±0.1 4 10.16 7.62 0.8 0.4 7.62 10.16±0.1 7.62±0.1 Terminal Arrangement/ Internal Connections (Bottom View) − Input voltage + 1 − Input (−) 3 (+) 4 (−) Load power supply Load (+) Load + 6 Note: Values in parentheses apply to the DC-load versions. Solid State Relay G3S/G3SD 399 Connecting Socket P6B-04P (23)* 23.2 max. PCB Dimensions (Bottom View) 10 max. (9.9)* Four, 1.1-dia. holes 2.54 3 2.54 10.1 max. (10)* 7 3.5 (2.71) 10.16 0.8 7.62 0.4 7.62 *Average value Heat Sink Y92B-S08N 48.2+0 −0.3 1 8 1 6.3 1 6.3 1 6.3 1 6.3 1 8 20 +0 −0.3 1 8 +0 −0.25 3 0.5 0.5 Mounting Bracket 6 4 4 20 +0.3 −0 1 +0 −0.2 PCB Dimensions (Bottom View) 6 4 7.62 4.5 7.62 4.5 7.62 4.5 7.62 10.16 16 15.5 18 7.62 0.7 2.6 7 4.2 0.8 Precautions Close Mounting Load current (A) G3S-201PL-PD and G3SD-Z01-PD SSRs can be closely mounted side by side. Attach the Y92B-S08N Heat Sink to the SSRs mounted closely side by side. When these SSRs are mounted side by side, the load current vs. ambient temperature characteristic declines as shown on the right. Load Current vs. Ambient Temperature Characteristics (When four SSRs are mounted side by side and each of them is switched to the same load current.) Ambient temperature (°C) Connection Protective Component With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load. 400 Solid State Relay G3S/G3SD MEMO Solid State Relay G3S/G3SD All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X301-E-1b Solid State Relay 09/11 Specifications subject to change without notice G3S/G3SD Printed in USA