Datasheet

G3MC
Solid State Relays
Reinforced Insulation Models
Added to Compact,
Thin-profile Series of SSRs
for PCBs
• 4.5-mm thin design for high-density PCB applications.
• DC input and AC output for applicable load of 1A (at 40°C)
and 2A (at 25°C).
• Compact, thin-profile SSR of monoblock construction with
an all-in-one lead frame incorporates a PCB, terminals and
heat sink
RoHS Compliant
Refer to "Solid State Relays Common Precautions".
■Model Number Legend
G 3 M C -@ @ @ @ @- @ @
———— —
1
2
3 4
5
1. Rated Load Power Supply Voltage
1: Maximum operating voltage lower than 132 V
2: Maximum operating voltage lower than 264 V
4. Zero Cross Function
Blank: Equipped with zero cross function
L : Not equipped with zero cross function
2. Rated Load Current
01: 1 A
02: 2 A
5. Certification
Blank: Certified by UL and CSA
(standard models)
VD : Certified by UL, CSA and EN
VD-1 : Certified by UL, CSA and EN
(reinforced insulation models)
3. Terminal Type
P: PCB terminals
G
3
M
C
■List of Models
Isolation
Zero cross
function
Indicator
Snubber
circuit
Rated output load
Rated input voltage
5 VDC
12 VDC
Yes
1 A at 100 to 120 VAC
No
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
Yes
Phototriac
12 VDC
No
Yes
1 A at 100 to 240 VAC
24 VDC
5 VDC
12 VDC
No
24 VDC
5 VDC
12 VDC
Yes
2 A at 100 to 240 VAC
No
24 VDC
5 VDC
12 VDC
24 VDC
Model
Minimun
packing unit
G3MC-101P
G3MC-101P-VD
G3MC-101PL
G3MC-101PL-VD
G3MC-201P
G3MC-201P-VD
G3MC-201P-VD-1
100 pcs
G3MC-201PL
G3MC-201PL-VD
G3MC-201PL-VD-1
G3MC-202P
G3MC-202P-VD
G3MC-202P-VD-1
G3MC-202PL
G3MC-202PL-VD
G3MC-202PL-VD-1
1
G3MC
Solid State Relays
■Ratings (at an Ambient Temperature of 25°C)
●Input (Each model has 5-VDC, 12-VDC, and 24-VDC input versions.)
Rated voltage
Operating voltage
Impedance
4 to 6 VDC
300Ω ± 20%
4 VDC max.
12 VDC
9.6 to 14.4 VDC
800Ω ± 20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
1.6 kΩ ± 20%
19.2 VDC max.
5 VDC
Must operate voltage level Must release voltage level
1 VDC min.
●Output
Item
Applicable load
Rated load voltage Load voltage range Load current
Model
G3MC-101P (-VD)
G3MC-101PL (-VD)
100 to 120 VAC
50/60 Hz
75 to 132 VAC
50/60 Hz
G3MC-201P (-VD) (-1)
G3MC-201PL (-VD) (-1)
100 to 240 VAC
50/60 Hz
75 to 264 VAC
50/60 Hz
G3MC-202P (-VD) (-1)
G3MC-202PL (-VD) (-1)
100 to 240 VAC
50/60 Hz
75 to 264 VAC
50/60 Hz
Inrush current
0.1 to 1 A *
8A
(60 Hz, 1 cycle)
0.1 to 2 A *
30 A
(60 Hz, 1 cycle)
* The load current varies depending on the ambient temperature. Refer to Load Current
vs. Ambient Temperature under Engineering Data.
■Characteristics
Model
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
1/2 of load power source cycle +
1 ms max.
1 ms max.
1/2 of load power source cycle +
1 ms max.
1 ms max.
Item
Operate time
Release time
1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
1 mA max. (at 100 VAC)
1.5 mA max. (at 200 VAC)
Insulation resistance
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min between input and output (3,000 VAC, 50/60 Hz for 1 min for G3MC-@@@-VD-1)
Vibration resistance
10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
1,000 m/s2
Shock resistance
Storage temperature
-30°C to 100°C (with no icing or condensation)
Ambient operating
temperature
-30°C to 80°C (with no icing or condensation)
Ambient operating
humidity
45% to 85%RH
Weight
Approx. 2.5 g (Approx. 3.8 g for G3MC-202P(L)(-VD)(-1)
■Engineering Data
Load current (A)
●Load Current vs. Ambient Temperature
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
Load current (A)
G
3
M
C
1,000 MΩ min. (at 500 VDC)
1.2
1.0
2.5
2.0
0.8
1.5
0.6
1.0
0.4
0.5
0.2
0
?30 ?20
0
20
40
60
80
100
Ambient temperature (°C)
2
0
?40
?20
0
20 25
40
60
80
100
Ambient temperature (°C)
G3MC
Solid State Relays
Inrush peak current (A. Peak)
Inrush peak current (A. Peak)
●One Cycle Surge Current: Non-repetitive Keep the inrush current to half the read value if it occurs repeatedly.
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
10
8
6
40
30
20
4
10
2
0
10
30 50
100
300 500 1,000
0
10
5,000
30 50
100
300 500 1,000
Energized time (ms)
5,000 10,000
Energized time (ms)
■Dimensions
(Unit: mm)
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-201PL(-VD)(-1)
PCB Dimensions
(Bottom View)
4.5 max.
Terminal Arrangement/
Internal Connections
(Bottom View)
24.5 max.
2.54
Four, 1.0-dia. holes
(−)4 3(+)
13.5 max.
0.8
2.54
INPUT
2
1
G
3
M
C
LOAD
3.5
2.54
0.25
4-1.6
4-0.7
10.16
1.2
7.62
2.54
G3MC-202P(-VD)(-1)
G3MC-202PL(-VD)(-1)
PCB Dimensions
(Bottom View)
4.5 max.
24.5 max.
2.54
Four, 1.0-dia. holes
Terminal Arrangement/
Internal Connections
(Bottom View)
(−)4 3(+)
2.54
20.5 max.
INPUT
2
1
LOAD
0.8
3.5
2.54
0.25
4-1.6
4-0.7
10.16
7.62
1.2
2.54
■Safety Precautions
●Please refer to “Solid State Relays Common Precautions” for correct use.
Precautions for Correct Use
• The terminals are made of materials with high heat
conduction. Complete reflow soldering within 10 seconds at a
temperature of 260°C. Complete manual soldering within 5
seconds at a temperature of 350°C.
• The SSR has a thin profile. To maintain the vibration resistance of
the SSR, make sure that the space between the SSR and PCB is
0.1 mm maximum. Lifting of the PCB can be prevented by setting
the hole diameter of the PCBs on both sides in the PCB
dimensions diagram to between 0.8 to 1.0 mm.
If the terminals will be subjected to stress due to constant vibration,
implement vibration countermeasures, such as with adhesive.
• Select the model without the zero-cross function when using the
Unit for phase control output.
• The casing works as a heat sink. When mounting two or more SSRs
close together, do not allow the ambient temperature to rise. If the rated
current will flow, provide a space between the SSRs equivalent to the
thickness of one SSR and provide proper ventilation. If poor ventilation
is unavoidable, reduce the load current by half.
• Although LOAD is incorporated with snubber circuit, do not wiring
high voltage line and power line together with or in the same duct
as the SSR. Doing so may result in malfunction or damage due to
induction.
• The input circuit is not incorporated with reverse connection
protection circuit. Make sure to check the polarity when wiring.
• Connect the surge absorbers (varistors) in parallel at both ends of
the LOAD terminal when applying a surge voltage over 250 V peak
for G3MC-10@P(L)(-VD), and over 450V peak for
G3MC-20@P(L)(-VD)(-1).
Load
INPUT
SSR
LOAD
3
G3MC
Solid State Relays
G
3
M
C
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
4
Contact: www.omron.com/ecb
Cat. No. J108-E1-05
1014(0207)(O)