ZG-1435-1 Operating Voltage = 125 / 250Vac Operating Current = 1.0 Ampere Frequency of Operation = 60—400 Hz Temperature Range (Storage) = -40 to 105 C Temperature Range (Operating) = -40 to 65 C Leakage current (Max) @ 125 V~, 60 Hz = 0.85 ma Dielectric Withstand (L-Grd), (1 Minute) = 1500 Vac Dielectric Withstand (L-L), (1 Minute) = 1500 Vdc A A C C B B Order P/N: ZG-1435-1 for MIL-STD-461C ZG-1435-1D for MIL-STD-461D or E 90 The ZG-1435-1 filter has been designed for systems operating under the requirements of MIL-STD-461C. If MIL-STD-461D or E are specified then part number ZG-1435-1D should be specified. The difference is that the differential capacitor is repositioned on the line side in order to match the test configuration of 461D and E. The filter case is environmentally sealed and is designed to handle the shock and vibration of wheeled vehicle installations. INSERTION LOSS (db) 80 70 CM 60 DM 50 40 30 20 10 0 The circuit uses feed through capacitors the insertion loss is 60 db to 1.0 Ghz and beyond. .1 .4 .2 100 400 1000 4 10 40 2 7 20 70 200 700 FREQUENCY (MEGAHERTZ) 1 .7 0.23 0.63 0.40 2.75 0.43 A B C 0.72 0.72 0.82 1.50 1.18 0.16 4-40 X .25 DP INSERT (4 PL) 1.18 0.59 PHOENIX TERM BLK MS3102R-10SL-3P USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884