ZL20200 Dual Band IS136/AMPS Transceiver Data Sheet Features December 2003 Ordering Information • Dual Band IS136 (800/1900 MHz) Compatible • Fully Integrated Dual Band Transceiver • Receive - IF to Baseband I and Q • Transmit - Baseband I / Q to RF • Integrated Filters • FM Demodulator Description • RF and IF Synthesizers • Fully Programmable via serial bus • 3 Volt operation • Small scale package The ZL20200 is a fully integrated transceiver for dual band IS136/AMPS handsets. The IF input to the receive path is amplified and down-converted to baseband I and Q signals. Gain control is provided. Baseband filtering is also included. A FM demodulator is also provided to support AMPS operation. ZL20200/LCE (Tubes) 56pinQFN ZL20200/LCF (Tape and Reel) 56pinQFN ZL20200/LDE (Tubes) Stamped 56pinQFN ZL20200/LDF (Tape and Reel)Stampled 56pinQFN -40 to +85°C Applications • Dual Band (850/PCS1900) TDMA/AMPS Mobile Telephones • Cellular 850 MHz TDMA/AMPS Mobile Telephones • PCS1900 TDMA Mobile Telephones • Cellular Telematic Systems The transmit path consists of a quadrature modulator, gain control at IF and up-conversion to RF. Dual band RF outputs are provided. The transmit output stages can be programmed to optimize performance and current consumption. ZL20200 also includes a fractional N RF synthesizer and two IF synthesizers to provide all local oscillator signals required. Rx I IS136 90° Rx Q FM Demod Rx VHF PLL RSSI LOCK DET Tx VHF PLL UHF LO O/P UHF VCO FM Serial Interface Control UHF PLL 900 MHz Tx IQ Mod Tx I Tx Q 1900 MHz Tx Tx IF Filter (Opt) Figure 1 - Block Diagram 1 Zarlink Semiconductor Inc. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright 2003, Zarlink Semiconductor Inc. All Rights Reserved. ZL20200 Data Sheet Flexible programming is provided via a 3 wire serial bus. Additional control pins allow accurate timing control when switching between modes. RX I+ RX I- FM FB FM OUT RX VCO- RX VCO+ VCC RX PLL RX GAIN VCC RX NC NC IF1 IN- IF1 IN+ VCC CONTROL Package Diagram SDAT RX Q- SCLK RX Q+ RSSI SLATCH TCXO RX CP VCC VHF CP VCC UHF PLL UHF CP ISET ZL20200 VCC UHF LO OUT 900 LO OUT LOCK DET TX CP TX RXB 1900 LO OUT RESETB TX I- ENABLE1 TX I+ 900 LO IN VCC TX PLL TX Q- TX Q+ TX FILT OUT- TX FILT OUT+ VCC TX TX FILT IN- TX FILT IN+ TX GAIN TX 1900 ENABLE2 TX DEG900 TX VCO+ TX DEG1900 1900 LO IN TX 900 TX VCO- VCC TX RF VCC UHF LO Figure 2 - ZL20200 Package Diagram 2 Zarlink Semiconductor Inc. ZL20200 Data Sheet Pin Description Pin Description Table No Pin Name Type Description 1 SDAT Input Serial Interface - Data 2 3 SCLK Input Serial interface - Clock SLATCH Input Serial Interface - Latch 4 TCXO Input Reference input from TCXO 5 VCC UHF PLL Power Power 6 UHF CP Output UHF PLL Charge Pump Output 7 VCC UHF LO OUT Power Power to LO output stages 8 900 LO OUT Output 900 MHz buffered LO output to external receiver mixer 9 1900 LO OUT Output 1900 MHz buffered LO output to external receiver mixer 10 RESETB Input Reset (Active low) 11 ENABLE1 Input Mode Control 12 900 LO IN Input 900 MHz LO input 13 VCC UHF LO Power Power to UHF LO input stage 14 1900 LO IN Input 1900 MHz LO input 15 VCC TX RF Power Power to transmit RF output stages 16 TX 900 Output 900 MHz transmit output 17 TX DEG900 Degeneration for 900 MHz output - Connect to Ground 18 TX DEG1900 Degeneration for 1900 MHz output - Connect to Ground 19 TX 1900 Output 1900 MHz transmit output 20 ENABLE2 Input Mode Control 21 TX GAIN Input Transmit gain control 22 TX FILT IN+ Input 23 TX FILT IN- Input 24 VCC TX Power 25 TX FILT OUT+ Output 26 TX FILT OUT- Output 27 TX Q+ Input 28 TX Q- Input 29 TX VCO+ 30 TX VCO- 31 VCC TX PLL Power 32 TX I+ Input 33 TX I- Input Input from transmit IF filter (optional) Power to transmit stages Output to transmit IF filter (optional) Q transmit signal from baseband Transmit Oscillator tank circuit Power to Transmit VHF PLL I transmit signal from baseband 34 TX RXB Input Transmit / Receive control 35 TX CP Output Transmit VHF PLL charge pump output 36 LOCK DET Output PLL Lock Detect Output 37 ISET Connect 50 kohm resistor to ground to set internal reference current 3 Zarlink Semiconductor Inc. ZL20200 Data Sheet Pin Description Table (continued) No 38 Pin Name VCC VHF CP Type Power Description Power to VHF charge pump outputs 39 RX CP Output Receive VHF PLL charge pump output 40 RSSI Output RSSI Output 41 RX Q+ Output 42 RX Q- Output 43 RX I+ Output 44 RX I- Output 45 FM OUT Output 46 FM FB 47 RX VCO- 48 RX VCO+ Baseband Q signal Baseband I signal Demodulated FM output Feedback to FM output stage Receive second LO Oscillator tank circuit 49 VCC RX PLL Power Power to receive VHF PLL 50 VCC RX Power Power to receive stages 51 RX GAIN Input Receive gain control 52 NC Not Connected 53 NC Not Connected 54 IF1 IN- Input IF Input (1) 55 IF1 IN+ Input IS136 Input 56 VCC CONTROL Power Power to serial interface logic 4 Zarlink Semiconductor Inc. ZL20200 Data Sheet Table of Contents Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Package Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.0 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.1 Receive Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.1.1 IS136 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.1.2 AMPS FM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.2 Transmit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 1.3 UHF LO and Frequency Doubler. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1.4 UHF Frequency Synthesizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1.5 VHF Frequency Synthesizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1.6 Internal Clock Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 1.7 VHF VCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 1.8 Power Supply Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2.0 Programming and Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2.1 Power Control Registers - Address 0 to 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2.1.1 Power Control Modes - TDMA (IS136) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2.1.2 Power Control Modes - AMPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 2.2 Operating Register Address 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 2.3 Synthesizer Register - Address 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2.3.1 UHF PLL and LO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2.3.2 UHF PLL Charge Pump Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 2.3.3 Receive LO Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 2.3.4 Transmit LO Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 2.4 Control Register - Address 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 2.4.1 IS136 Baseband Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 2.4.2 TCXO Reference Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 2.4.3 Discriminator Output Filtering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 2.4.4 Transmit Baseband Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 2.4.5 Mode Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 2.5 Register Address 7 - Not Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 2.6 Test Mode Register - Address 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 2.7 UHF PLL Divider Programming Register - Address 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 2.8 UHF PLL Reference Divider and Fractional N Programming Register - Address 10 . . . . . . . . . . . . . . . . 36 2.9 Receive VHF PLL Divider Programming Register - Address 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 2.10 Receive VHF PLL Reference Divider Programming Register - Address 12 . . . . . . . . . . . . . . . . . . . . . . 37 2.11 Transmit VHF PLL Divider Programming Register - Address 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 2.12 Transmit VHF PLL Reference Divider Programming Register Address 14 . . . . . . . . . . . . . . . . . . . . . . . 37 2.13 PLL Lock Detect & Fractional N Compensation Programming Register Address 15 . . . . . . . . . . . . . . . 37 2.13.1 Fractional N Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 2.13.2 PLL Lock detect counters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 3.0 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 4.0 Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 5.0 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 6.0 Typical Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 6.1 Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 6.2 Transmit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 5 Zarlink Semiconductor Inc. ZL20200 Data Sheet List of Figures Figure 1 - Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 2 - ZL20200 Package Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 3 - ZL20200 Detailed Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Figure 4 - IS136 Receiver Signal Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Figure 5 - AMPS Receive Signal Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Figure 6 - Transmit Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 7 - External Transmit IF Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Figure 8 - UHF Synthesizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Figure 9 - Count Sequence for UHF PLL with 4 Modulus Prescaler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 10 - UHF Synthesizer - Fractional N Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Figure 11 - VHF Frequency Synthesizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 12 - Typical VCO Tank Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 13 - Serial Bus Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 14 - Transmit Output Stage Current versus Gain Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6 Zarlink Semiconductor Inc. ZL20200 Data Sheet List of Tables Table 1 - IS136 Receive Gain and Filter Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Table 2 - AMPS FM Receive Gain and Filter Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Table 3 - Transmit Circuit blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 4 - Power Supply Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table 5 - Power Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 6 - Power Control Register Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 7 - Programming for the Power Control Registers (0 - 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 8 - Enable Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Table 9 - Function of the Receive Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 10 - Function of the Transmit Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Table 11 - Gain of the Transmit Output Stage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Table 12 - VGA Threshold Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Table 13 - VGA Current Reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Table 14 - Output Stage Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Table 15 - Control Register Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 16 - UHF PLL and LO Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 17 - Fractional N Denominator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 18 - UHF PLL Charge Pump Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 19 - Receive LO Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 20 - Receive VHF PLL Charge Pump Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 21 - Transmit LO Set Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Table 22 - Transmit VHF PLL Charge Pump Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Table 23 - Baseband Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Table 24 - TCXO Reference Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Table 25 - FM Discriminator Output Filter Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Table 26 - Transmit Baseband Gain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Table 27 - Mode Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 7 Zarlink Semiconductor Inc. ZL20200 1.0 Data Sheet General Description A detailed block diagram is shown in Figure 3. This shows the receive and transmit paths plus the LO generation circuitry. Control is via a serial bus with the addition of direct inputs to control receive and transmit modes and optimize power consumption. 43 RX I+ 44 RX I– IF1 IN+ 55 AMPS demod. and RSSI IF1 IN– 54 π /2 45 FM OUT 46 FM FB 40 RSSI 60kHz RX GAIN 51 41 RX Q+ 42 RX Q– ÷N π /2 RX CP RX VCO– 6 5 30 Option 14 1900 LO IN Tank Circuit 10 11 20 34 RESETB ENABLE1 ENABLE2 TX RXB 56 VCC CONTROL Loop Filter TX VCO– LO Select and Doubler VCC UHF PLL 8 36 LOCK DET Control VCC TX PLL 31 VCC VHF CP 38 Loop Filter UHF CP 900 LO OUT Control TCXO 4 12 9 Loop Filter I SET 37 VCC RX PLL 49 900 LO IN 1900 LO OUT 39 RX VCO+ VCC RX 48 Tank Circuit Synth Programming 7 47 TX CP VCC UHF LO OUT 13 50 TX VCO+ VCC UHF LO PLL 29 35 Serial interface 1 SDAT 2 SCLK 3 SLATCH PLL PLL π /2 π /2 TX 1900 19 32 TX I+ 33 TX I– π /2 Σ MUX 27 TX Q+ 28 TX Q– 22 TX DEG900 VCC TX RF TX FILT IN– TX FILT IN+ Option 25 26 21 24 VCC TX 23 TX GAIN 15 TX FILT OUT– 17 TX FILT OUT+ 18 TX DEG1900 TX 900 16 Figure 3 - ZL20200 Detailed Block Diagram 8 Zarlink Semiconductor Inc. ZL20200 1.1 Data Sheet Receive Path The IF input receives an input signal from IS136/AMPS filter. The differential input stage is followed by an agc amplifier. Gain control is provided from an external analog voltage. After the agc amplifier the signal is then downconverted to a low IF frequency and the signal flow then depends on the mode selected. All internal signals are differential. The LO frequency for the down conversion is derived from an on chip oscillator and PLL. The LO frequency can be programmed to be either oscillator frequency divided by 2 or 4. When in divide by 2 mode a DLL (Delay Locked Loop) circuit can be selected to maintain accurate quadrature. It is particularly important to have good quadrature in IS136/AMPS modes using a low IF frequency, to achieve the required image rejection in conjunction with the following polyphase bandpass filter. It is also possible to programme high side or low LO injection. Each receive mode will now be described in more detail 1.1.1 IS136 The IS136 receive signal path is shown in detail in Figure 4 and performance for each stage is summarized in the following table. Circuit Block IF Input (IF1) AGC Amplifier Quadrature Down-converter Gain (dB) Filter Bandwidth (If Applicable) 26 max Description Differential IF input stage AGC Amplifier - Gain control range 90 dB Down-conversion to 60 kHz IF 47 Anti-alias filter 230 kHz Band Pass Filter Low pass Butterworth (n= 3) +/- 20 kHz Switched capacitor polyphase Chebyshev. Also provides typically 30 dB image rejection. Centre frequency = 60 kHz. Clock frequencies 1.44 MHz and 720 kHz. Gain Stage Baseband Down-converter Baseband filter 1 Baseband filter 2 Down conversion to baseband I and Q signals 7 37.5 kHz Switched capacitor low pass Chebyshev. Clock frequency = 240 kHz 60 kHz Smoothing filter. Low pass Butterworth Table 1 - IS136 Receive Gain and Filter Distribution The output of the agc amplifier is down-converted using a quadrature mixer to a low IF of 60 kHz. High side or low side LO injection can be selected. The In Phase (I) and Quadrature (Q) signals at 60 kHz are then passed through anti alias filter stage to remove any high frequency signals prior to subsequent sampling. The 60 kHz IF signals are then fed into a switched capacitor polyphase bandpass filter which not only provides filtering but also provides image rejection. This switched capacitor filter provides very stable performance and no calibration is required. After the bandpass filter the 60 kHz IF signal is further amplified and then mixed down to baseband I and Q signals. Additional filtering is required at baseband to remove spurii from the down-converter. This filtering is provide in two stages, the first stage is a switched capacitor filter with the second stage being a smoothing filter to remove clock breakthrough from the preceding switched capacitor filter. The differential baseband outputs can then be fed directly into analog to digital converters on a baseband processor. 9 Zarlink Semiconductor Inc. IF1 IF Input Zarlink Semiconductor Inc. 10 Quadrature Downconverter Tank Circuit Div2 /Div4 Quadrature Receive VHF VCO AGC Amplifier Figure 4 - IS136 Receiver Signal Flow Loop Filter Recieve VHF PLL Rx VHF PLL Anti Alias Filter Anti Alias Filter Band Pass Filter Gain Receive Baseband RSSI Limiter RSSI Baseband Filter 1 60 kHz Baseband Filter 1 FM Discriminator Baseband Filter 2 Baseband Filter 2 RSSI Q I ZL20200 Data Sheet ZL20200 1.1.2 Data Sheet AMPS FM FM demodulation can be performed using the I and Q baseband signals if supported by the baseband. However the ZL20200 also contains an FM demodulator, the AMPS receive signal path using this mode is shown in detail in Figure 5 and performance for each stage is summarized in the following table. Circuit Block IF Input (IF1) AGC Amplifier Gain (dB) Filter Bandwidth (If Applicable) Differential IF input stage 26 max AGC Amplifier - Gain control range 90 dB. Includes IF input stage gain. Quadrature Down-converter Down-conversion to 60 kHz IF Anti-alias filter Band Pass Filter Description 230 kHz 73 +/- 16 kHz Low pass Butterworth Switched capacitor polyphase Chebyshev. Also provides typically 30 dB image rejection. Centre frequency = 60 kHz. Clock frequency 1.44 MHz and 720 kHz. Limiter Provides limited output to discriminator. Also provides RSSI output. FM Discriminator Digital FM discriminator Baseband filter 2 (I Channel) 30 kHz Smoothing filter. Low pass Butterworth. Provides filtering of FM discriminator output. Baseband filter 1 (I Channel) 25 kHz Switched capacitor low pass Chebyshev. Clock frequency = 240 kHz. Provides additional filtering of discriminator output. Selected using PDF and LPC bits Baseband filter 1 (Q Channel) 25 kHz Switched capacitor low pass Chebyshev. Clock frequency = 240 kHz. Provides additional filtering of discriminator output. Selected using PDF and LPC bits Baseband filter 2 (Q Channel) 60 kHz Smoothing filter. Low pass Butterworth. Provides filtering of FM discriminator output. FM Output 30 kHz Configured using external components as bandpass filter. Table 2 - AMPS FM Receive Gain and Filter Distribution The signal path is initially the same as for IS136 with the down conversion to 60 kHz and channel filtering in the bandpass filter. In FM mode however, the baseband I and Q output stages are disabled, and the 60 kHz IF signal from the bandpass filter is input to a limiting amplifier and FM discriminator. The FM discriminator consists of a shift register acting as a delay line. The output of the discriminator is a digital signal which must then be filtered to recover the audio signal. The discriminator output is therefore routed through the baseband I and Q filters. The default condition is to use the cascaded I and Q smoothing filters (baseband filter 2) with the cut-off frequency set to 30 kHz. This connection is automatically selected when programming FM mode. There is an option to use the cascaded switched capacitor filters (baseband filter 1) with the cut off frequency set to 25 kHz to provide extra filtering. These filters are selected using the PDF and LPC bits in control register 6 and are inserted between the smoothing filters as shown in Figure 5. The final output stage uses external feedback components to provide a bandpass filter with a bandwidth of at least 300 Hz to 10 KHz to cover the demodulated audio and control signals. The feedback components can be modified to change the output level to optimize compatibility with baseband. 11 Zarlink Semiconductor Inc. ZL20200 Data Sheet A RSSI output is provided. This is a full wave rectified output of the 60 kHz IF and therefore has a high 120 kHz content. This requires an external low pass filter - typically 10 kohm and 2.7 nF. There is a trade-off between settling time and filtering. This is different to conventional RSSI circuits which operate at typically 450 kHz which is much easier to filter. Although the AMPS receive path includes a limiting amplifier, gain control is also required. This is because the band pass filter has limited dynamic range (50 dB). At low signal levels the agc should be set to 1.6 volts to set the gain 20 dB below maximum to obtain optimum signal handling and noise performance. At higher signal levels the gain setting should be reduced to maintain the RSSI level approximately 10 dB below maximum. Gain control would be provided by the baseband controller which would also monitor the RSSi level. Fine gain control is not required and can be implemented in large steps e.g. 20 dB, allowing the use of a relatively slow gain control loop giving optimum performance under fading conditions. 12 Zarlink Semiconductor Inc. IF1 IF Input Zarlink Semiconductor Inc. 13 Quadrature Downconverter Tank Circuit Div2 /Div4 Quadrature Receive VHF VCO AGC Amplifier Figure 5 - AMPS Receive Signal Flow Loop Filter Recieve VHF PLL Rx VHF PLL Anti Alias Filter AntiAlias Filter Band Pass Filter Gain Receive Baseband RSSI Limiter RSSI Baseband Filter 1 60 kHz Baseband Filter 1 FM Discriminator Baseband Filter 2 Baseband Filter 2 FM FB FM OUT RSSI Q I ZL20200 Data Sheet ZL20200 1.2 Data Sheet Transmit Transmit operation is similar for all modes and a detailed diagram is shown in Figure 7. This diagram also shows the UHF LO generation circuit blocks. A summary of the characteristics of the transmit path circuit blocks are given in the table below. All circuit blocks are differential with the exception of the transmit RF outputs. Circuit Block Gain (dB) Bandwidth (If Applicable) Reconstruction Filters 0 -12 IS136/AMPS 12.5 kHz Quadrature Modulator Transmit IF Description Baseband input stage. Gain is programmable in 3 dB steps from 0 to 12 dB. There is also a by-pass mode so that the baseband I and Q signal can go direct to the modulator Generates a modulated IF signal 400 MHz Provides gain control at IF frequency. This stage also includes a low pass filter to remove harmonics and spurii from modulator output. This stage also includes a buffered IF output which can be used with an external IF filter. Up-converter SSB up-converter to RF frequency. The IF path includes phase shift networks for the up-converter. This stage also includes the input circuit from the optional external IF filter Transmit RF The 900 MHz and 1900 MHz RF stages each consist of 2 stages. The first stage gain be set from -6 to +3 dB in 3 dB steps. Output stage current is controlled by agc signal to reduce current consumption at low output power levels. Each output stage requires an external degeneration inductor Table 3 - Transmit Circuit blocks Differential baseband transmit I and Q signals from a baseband processor are input to the ZL20200. The baseband signals are passed through filters. A quadrature modulator modulates these baseband signals on to the transmit IF which is typically around 200 MHz. This modulated IF signal is passed through an on chip low pass filter which removes harmonics of the IF and then into a gain controlled amplifier. This amplifier is controlled by an external analog signal and provides greater than 60 dB gain control The output of the gain controlled amplifier can then be up-converted to RF or alternatively the output can be sent to an off chip filter to provide further filtering and removal of noise before up-conversion. This filter is a parallel tuned circuit as shown in Figure 7. The choice of component values is dependent on the IF frequency being used. The filter output is then fed back on chip to the up-converter. A SSB mixer is used for the up-conversion to remove the unwanted image. High side or low side LO injection can be selected. A buffer amplifier after the up-conversion provides a further 9 dB gain control in 3 dB increments. This gain is programmable via the serial bus and can be used to optimize noise and linearity performance in particular applications. Finally there are two RF output stages for 900 MHz and 1900 MHz frequency bands. Each RF output is single ended and requires a simple matching network. The supply current of the output stages is automatically reduced at low transmit gain control voltages improving the efficiency of the output buffer at low output power levels. The supply current of the output buffer can also be controlled via the serial bus. This allows the supply current to be reduced which is particularly useful when using AMPS where the linearity performance is less critical. The FM modulation for AMPS can be done using I,Q modulation if available. Alternatively FM modulation can be applied direct to the transmit IF VCO. The loop bandwidth for the transmit VHF PLL should be low (~100 Hz) to ensure the PLL does not remove the modulation. A dc voltage should be applied across the Tx I+, Tx I- and the Tx Q+, Tx Q- inputs to switch the modulator and generate an IF carrier signal. With a baseband gain of 0 dB a dc voltage of at least 1.5 volts should be applied; a lower voltage can be used with the baseband gain increased to compensate. It is assumed that this bias can be provided by the baseband however if this is not possible then the simplest solution is to connect 200 kohm resistors between I+, Q+ inputs and Vcc and 200 kohm resistors between I-, Q- inputs and ground, assuming the transmit outputs from the baseband are in a high impedance state in AMPS 14 Zarlink Semiconductor Inc. Zarlink Semiconductor Inc. 15 900 LO OUT 1900 LO OUT TX DEG900 TX 900 TX DEG1900 TX 1900 UHF LO Buffer Transmit RF Frequency Doubler Figure 6 - Transmit Path 900 LO IN 900MHz VCO Mux Quadrature UHF LO Input Buffer Σ Mux 1900 LO IN Mux Transmit UHF LO 1900MHz VCO Mux -π/4 +π/4 Transmitter Upconverter IF Input TX FILT IN +/- Loop Filter UHF CP UHF PLL UHF Synthesiser Transmit IF TX FILT OUT +/- Mux Optional External Transmit IF Filter Low Pass Filter Tank Circuit Loop Filter TX CP Transmit VHF PLL Tx VHF PLL Baseband Transmit Filter Optional By-pass Mode Baseband Transmit Filter Transmit Reconstruction Filters TX VCO+/- Div2 / Div4 Quadrature Transmit VHF VCO Σ Transmit Quadrature Modulator TX Q+/- TX I+/- ZL20200 Data Sheet mode. These resistors do produce a small dc offset in TDMA mode when the I and Q inputs are in use, however this is insignificant if the output impedance of baseband transmit outputs is less than 1 kohm. As the FM modulation is applied direct to the VCO in this mode and is external to the ZL20200, any necessary filtering of the FM signal must be provided externally. ZL20200 Data Sheet Figure 7 - External Transmit IF Filter 1.3 UHF LO and Frequency Doubler Figure 7 also shows the UHF LO buffering and frequency doubler. The ZL20200 is designed to operate either with separate external UHF VCOs for the 900 and 1900 MHz frequency bands, or alternatively a single 900 MHz VCO can be used with the on-chip frequency doubler providing the LO for the 1900 MHz band. A UHF synthesizer is included. The input to the UHF synthesizer will normally be the active UHF LO signal, however when using the frequency doubler mode for 1900 MHz LO generation, the synthesizer input can be selected to be either the frequency doubler output or the 900 MHz input LO signal. The UHF LO input buffer minimizes any load pulling effects on the UHF VCO when internal modes are switched. UHF LO output buffers are also provided. These can be used to drive an external mixer for the receive section. If not required these buffers can be powered down. 1.4 UHF Frequency Synthesizer A fractional N UHF synthesizer is included on the ZL20200 to provide LO signals for the transmit up-converter and the external receive RF down-converters. The UHF synthesizer operates with an external VCO. A block diagram of the synthesizer is shown in Figure 8. . Lock Detect TCXO Reference Counter 14 bit Phase Detector UHF LO Quad Modulus Prescaler 64/65/72/73 +1 M Counter 13 bit +8 B 3 bit Fractional N Counter A 4 bit Frac N Compensation 8 bits +1 Fractional N Scaling DAC 5 bits Fractional N Compensation DAC Figure 8 - UHF Synthesizer 16 Zarlink Semiconductor Inc. Charge Pump UHF CP ZL20200 Data Sheet The synthesizer uses a 4 modulus prescaler with an 'M' counter and 'A' and 'B' swallow counters together with a fractional N counter in the UHF counter allowing maximum flexibility. The reference counter is a simple 14 bit counter. All counter values are programmed via the serial bus and programming details are shown in the programming section. Each of the counters operates as count down. At the start of a count the counters are loaded with their respective values. The initial prescaler ratio is dependent on the values loaded into the A and B counters; when both the A and B counters reach zero the prescaler ratio is 64 and then remains until the M counter reaches zero. The complete process is then repeated. This can be shown in a simple example where M = 9, A = 4 and B = 2 which gives a total divide ratio of 596. The count sequence is shown in Figure 9. M Counter 9 8 7 6 5 4 3 2 1 9 8 A Counter 4 3 2 1 0 0 0 0 0 4 3 2 1 0 0 0 0 0 0 0 2 1 73 73 65 65 64 64 64 64 64 73 73 +1 Prescaler B Counter +8 Prescaler Prescaler Figure 9 - Count Sequence for UHF PLL with 4 Modulus Prescaler At the start of the count sequence the '+1' and '+8' controls to the prescaler are both asserted and the prescaler ratio is 73. After 2 cycles only the '+1' control is asserted and the divide ratio is 65. After a further 2 cycles the A counter reaches zero as well and the prescaler ratio is 64 for the remainder of the count sequence. At the end of the sequence all counters are reloaded and the sequence repeats. The total divide ratio (N) for this type of counter is given by N = 64*M + 8*B + A M is always greater then A or B A value of A = 0 does not support fractional N operation. Valid values of A are 1 to 8. The values of M, B and A can be easily calculated from the total divide ratio as shown below. M = INT ((N - 1)/64) B = INT (((N - 1) - 64*M)/8) A = N - 64*M - 8*B The value of M must always be greater than A or B. The maximum value of B is 7. 17 Zarlink Semiconductor Inc. ZL20200 Data Sheet The UHF synthesizer also includes a fractional N capability which allows the use of higher comparison frequencies but maintain narrow channel spacing. The use of higher comparison frequencies allows faster loop settling and reduces comparison spur level. This is particularly important in TDMA mode where settling times of < 1.5 ms are required and still obtain good spur performance. Fractional N allows the use of non-integer divide ratios. For example if the total divide ratio is N + 1/5 the counter will divide by N for 4 count cycles and N+1 on the fifth cycle giving the required total divide ratio over five cycles. The ZL20200 can use 5,8,13 or 20 as the fractional denominator (also referred to as the fractional modulus) allowing maximum flexibility in the choice of comparison frequencies. An extra counter - fractional N counter - is required. The input to this counter is from the M counter output. The fractional N modulus can be programmed to be 5,8,13, or 20. Each output pulse from the M counter will increment the fractional N divided by the required fractional numerator. For example if the fraction is 2/5 then the fractional N counter will increment by 2 for each output pulse from the M counter. When the fractional N counter overflows the A counter is incremented by 1, thus generating an additional '+1' count sequence. An example is shown in Figure 10 for a divide ratio of 596+2/5. The values for M, A, B are calculated using the integer value (596) as in the previous example. The fractional denominator is programmed as 5 and the fractional numerator as 2. At the end of the first count cycle (596) the fractional counter is incremented to 2. At the end of the third count cycle the fractional N counter overflows, incrementing the A counter by 1 which gives a subsequent count cycle of 597. After five count cycles the sequence repeats with a total count of 2982 over the five count cycle giving a mean value of 596 + 2/5. Total Count Cycle Count Value Fractional N Counter 596 596 597 596 597 596 2 4 1 3 0 2 4 4 5 4 5 4 0 Initial A Counter Value Figure 10 - UHF Synthesizer - Fractional N Operation A result of this count sequence is that the output phase of the total counter changes through the count cycle, which causes the output pulse from the phase detector, and therefore the charge pump, to vary. This would cause large fractional spurs on the synthesizer output. These spurs can be compensated by applying a current pulse with the opposite polarity to the charge pump output. This compensation pulse has a fixed width of two reference clock (TCXO) periods; the amplitude is proportional to the value in the fractional N counter. The correction current is scaled by a 8 bit compensation DAC, with an externally provided input from the serial bus. This allows performance to be optimized in a given application. The compensation value can be calculated from the following formula: Comp Value = 255 - INT((Icp * Ftcxo)/(0.0245 * 6 * MOD *Fvco)) where Icp = charge pump current (uA) 18 Zarlink Semiconductor Inc. ZL20200 Ftcxo = Reference frequency MOD = Fractional Modulus Fvco = UHF VCO Frequency Data Sheet The synthesizer provides a lock detect output. When the output pulse from the phase detector is less than half a reference clock period an in-lock signal is generated. These in-lock signals then clock a 4 bit counter into which a threshold value has been programmed. When the required number of successive in-lock pulses have been generated the lock detect output is set. The ZL20200 has a single lock detect output pin for the UHF synthesizer and VHF synthesizers. The lock detect signal is asserted when all active synthesizers are in lock. If a synthesizer has not been enabled in the power control registers then that synthesizer will be inactive and will have no effect on the lock detect output. 1.5 VHF Frequency Synthesizers The ZL20200 includes two VHF synthesizers to generate the second LO for the receiver and the transmit IF. They operate with their respective on-chip VHF VCO's and off-chip loop filters. The tank circuits and tuning components for the VCO's are also off chip. The two synthesizers are identical and are shown in Figure 11. Lock Detect TCXO Reference Counter 14 bit Phase Detector VHF LO Dual Modulus Prescaler 16/17 Charge Pump VHF CP M Counter 13 bit +1 A 4 bit Figure 11 - VHF Frequency Synthesizer The synthesizer uses a 2 modulus 16/17 prescaler with an 'M' counter and an 'A' swallow counter. This allows maximum flexibility when using this synthesizer. The reference counter is a simple 14 bit counter. All counter values are programmed via the serial bus and programming details are shown in the programming section. Both counters operate as count down. At the start of a count the counters are loaded with their respective values. The initial prescaler ratio is 17 assuming A > 0; when the A counter reaches zero the prescaler ratio is 16 until the M counter reaches zero. The complete process is then repeated. The total divide ratio (N) for this type of counter is given by N = 16*M + A M is always greater then A The values of M and A can be easily calculated from the total divide ratio N. M = INT (N/16) A = N - 16*M 19 Zarlink Semiconductor Inc. ZL20200 Data Sheet The maximum value for A is 15 and M must always be greater than A. The VHF PLLs do not have fractional N capability however it is recommended that they are operated at as high a comparison frequency as allowed by the chosen frequency plan to minimize spurs levels. Both VHF synthesizers have lock detection circuits. These operate in the same way as described for the UHF synthesizer. 1.6 Internal Clock Generation ZL20200 can use 14.4 MHz or 19.44 MHz reference frequency. The appropriate reference must be programmed via the serial bus. The clock signals for the switched capacitor filters and FM demodulator are generated from the reference TCXO signal. The internal divide ratios are switched to give the correct ratio. From PLL Loop Filter 10k VCO+ 43R 18p nm 10k 18p 43R VCO- 33n Figure 12 - Typical VCO Tank Circuit 1.7 VHF VCO ZL20200 has two VHF VCOs which operate with the VHF PLLs to provide the IF LO signals for both receive and transmit IF signals. The oscillators are a differential design and require an external tank circuit. A basic circuit with varactor is shown in Figure 12. It is recommended to include series resistors (e.g. 43 ohms) in each arm of the tank circuit to prevent any spurious high frequency oscillation due to parasitic capacitances. 20 Zarlink Semiconductor Inc. ZL20200 1.8 Data Sheet Power Supply Connections The circuit blocks within ZL20200 have separate supply connections to minimize interaction between circuit blocks. Details are shown in the earlier ‘Pin Names’ section. These supplies are also grouped to allow different groups of supply pins to be connected to separate supplies for example, receive or transmit. These groups are shown below: VCC – Control Supply Pin No. Pin Name 56 VCC CONTROL VCC – TxRx Common (Synth) Pin No. Pin Name 5 VCC UHF PLL 7 VCC UHF LO OUT 13 VCC UHF LO 38 VCC VHF CP 8 900 LO OUT 9 1900 LO OUT VCC – Rx Pin No. Pin Name 49 VCC RX PLL 50 VCC RX VCC – Tx Pin No. Pin Name 15 VCC TX RF 24 VCC TX 31 VCC TX PLL 16 TX 900 19 TX 1900 Table 4 - Power Supply Connections The LO OUT and TX 900/1900 pins require bias and are normally connected to VCC through an inductor. All supply pins within a group must be powered together. Each group of pins can be powered up independent of the other groups. 21 Zarlink Semiconductor Inc. ZL20200 2.0 Data Sheet Programming and Control Programming via the serial bus is via 24 bit words with a 4 bit address as shown below 23 22 21 20 19 18 17 17 15 14 13 12 11 10 9 8 7 6 5 Data 4 3 2 1 0 Address Bit23 (MSB) is loaded first. Bits 3:0 are used as address bits for the control registers. Details of serial bus timing are shown in Figure 13. SCLK t1 t2 t3 t6 SDAT Bit 23 Bit 22 Bit 21 Bit 0 t4 SLATCH ENABLE1/2 t5 t7 Figure 13 - Serial Bus Timing Enable1 and Enable2 need only be asserted after loading registers 0 to 3, the power control registers. These registers should be loaded with Enable1 and Enable2 low. All other registers can be loaded with Enable1 and Enable2 high or low. 2.1 Power Control Registers - Address 0 to 3 These registers are used in conjunction with the TX RXB and ENABLE1 and ENABLE2 control pins to power up the required sections of the device for any required mode. This enables power consumption to be optimized under all conditions. Figures 4 - 7, which show the receive and transmit paths in detail, show which sections are powered up by each control bit. 22 Zarlink Semiconductor Inc. ZL20200 Data Sheet The assignment is common for each of the registers 0 to 3 and is shown below. Bit Circuit Section 23 Not used 22 Receive Baseband section 21 UHF LO Buffer 20 Receive VHF VCO 19 UHF synthesizer 18 Receive RSSI circuit 17 Not used 16 Receive Quadrature down-converter 15 Receive VHF PLL 14 Receive IF input 13 Receive AGC amplifier 12 Transmit reconstruction filters 11 Transmit RF 10 Transmit UHF LO 9 UHF LO input buffer 8 Transmit IF 7 Transmit quadrature modulator 6 Transmit VHF PLL 5 Transmit VHF VCO 4 Transmit up-converter IF input Table 5 - Power Control Registers Note 1: Note 2: If a bit is set to logic 1 then that circuit section is powered on. UHF LO input (bit 9) must be enabled for Transmit UHF LO (bit 10), UHF synthesizer (bit 19) and UHF LO Buffer (bit 21) to be active. 23 Zarlink Semiconductor Inc. ZL20200 Data Sheet The 4 registers address 0 to 3 are assigned as follows: Register Address Register Name Description 0 Receive All circuit blocks required in receive mode should be set to 1. This register will be selected when TX RXB is low. No circuits will be actually powered up if ENABLE1 and ENABLE 2 are both low. 1 Transmit Transmit register All circuit blocks required in transmit mode should be set to 1. In duplex modes e.g. AMPS then both receive and transmit circuits must be selected. This register will be selected when TX RXB is high. No circuits will be actually powered up if ENABLE1 and ENABLE 2 are both low 2 ENABLE1 Configuration This register determines which circuit sections are powered up when ENABLE1 is high. The contents of this register are logical ANDed with the contents of the Receive or Transmit register as selected by TX RXB input. 3 ENABLE2 Configuration This register determines which circuit sections are powered up when ENABLE2 is high. The contents of this register are logical ANDed with the contents of the Receive or Transmit register as selected by TX RXB input. Table 6 - Power Control Register Functions A feature of this programming approach is that once a phone operating mode has been selected and set up via the serial bus, all power control can then be via the TX RXB, ENABLE1 and ENABLE2 control pins. Alternatively full power control is possible via the 3 wire serial bus without the use of any external control pins. If ENABLE1 and ENABLE2 are both low then the device is in Sleep mode. No circuits will be enabled unless either ENABLE1 or ENABLE2 are high regardless of the contents of the receive and transmit registers. An example of how these control bits can be used, is that the oscillators and PLL circuits can be powered up and allowed to settle prior to powering up the complete transmit or receive path. In the case of the receive path the UHF synthesizer, UHF LO input buffer, UHF LO Buffer and Receive VHF VCO, Receive VHF PLL bits would be set in the ENABLE1 Configuration register. The ENABLE2 Configuration register would contain these bits plus the remainder of the receive path bits, Receive IF input, Receive AGC amplifier, Receive quadrature down-converter and receive baseband section. This is demonstrated in the following examples. 2.1.1 Power Control Modes - TDMA (IS136) In a TDMA system the transceiver will either operate in receive only, or transmit only mode. It is assumed that an interim power on state will be used during which the oscillators and PLLs will be set up, and allowed to settle prior to activating the full signal path. The suggested programming for the power control registers (0 - 3) is shown in the table below. Circuit Section Bit Receive Addr 0 Transmit Addr 1 Enable 1 Config. Addr 2 Enable 2 Config. Addr 3 23 Not used 0 0 0 0 22 Receive Baseband section 1 0 0 1 Table 7 - Programming for the Power Control Registers (0 - 3) 24 Zarlink Semiconductor Inc. Comments ZL20200 Circuit Section Bit Data Sheet Receive Addr 0 Transmit Addr 1 Enable 1 Config. Addr 2 Enable 2 Config. Addr 3 Comments Note 1 21 UHF LO Buffer 0 0 0 0 20 Receive VHF VCO 1 0 1 1 19 UHF synthesizer 1 1 1 1 18 Receive RSSI circuit 0 0 0 0 17 Not used 0 0 0 0 16 Receive Quadrature down-converter 1 0 0 1 15 Receive VHF PLL 1 0 1 1 14 Receive IF input 1 0 0 1 13 Receive AGC amplifier 1 0 0 1 12 Transmit reconstruction filters 0 1 0 1 11 Transmit RF 0 1 0 1 10 Transmit UHF LO 0 1 0 1 9 UHF LO input buffer 1 1 1 1 8 Transmit IF 0 1 0 1 7 Transmit quadrature modulator 0 1 0 1 6 Transmit VHF PLL 0 1 1 1 5 Transmit VHF VCO 0 1 1 1 4 Transmit up-converter IF input 0 1 0 1 Note 2 Table 7 - Programming for the Power Control Registers (0 - 3) (continued) Note 1: Note 2: Not required if driving external receive mixer direct from UHF VCO. Can be used for IS136 if required. The receive register contains all bits required when in receive mode: the transmit register contains all bits required in transmit mode. The Enable1 configuration register contains all bits required to power up oscillators and synthesizers in both receive and transmit mode. The Enable2 configuration register contains all bits required to power up the complete receive and transmit modes (this register can be set to all '1's if preferred). The following words should therefore be programmed on the serial bus (Hex format): Receive register (0) 59E200 Transmit register (1) 081FF1 Enable1 Config. register (2) 188262 Enable2 Config. register (3) 59FFF3 25 Zarlink Semiconductor Inc. ZL20200 2.1.2 Data Sheet Power Control Modes - AMPS When operating in AMPS mode the ZL20200 will operate in either Receive only or Duplex. The enable registers should therefore be programmed as shown below. Bit Circuit Section Receive Addr 0 Transmit Addr 1 Enable 1 Config. Addr 2 Enable 2 Config. Addr 3 23 Not used 0 0 0 0 22 Receive Baseband section 1 1 0 1 21 UHF LO Buffer 0 0 0 0 20 Receive VHF VCO 1 1 1 1 19 UHF synthesizer 1 1 1 1 18 Receive RSSI circuit 1 1 0 1 17 Not used 0 0 0 0 16 Receive Quadrature downconverter 1 1 0 1 15 Receive VHF PLL 1 1 1 1 14 Receive IF input 1 1 0 1 13 Receive AGC amplifier 1 1 0 1 12 Transmit reconstruction filters 0 1 0 1 11 Transmit RF 0 1 0 1 10 Transmit UHF LO 0 1 0 1 9 UHF LO input buffer 1 1 1 1 8 Transmit IF 0 1 0 1 7 Transmit quadrature modulator 0 1 0 1 6 Transmit VHF PLL 0 1 1 1 5 Transmit VHF VCO 0 1 1 1 4 Transmit up-converter IF input 0 1 0 1 Comments Note 1 Table 8 - Enable Registers Note 1: Not required if driving external receive mixer direct from UHF VCO. The receive register contains all bits required when in receive mode: the transmit register contains all bits required in duplex mode. The Enable1 configuration register contains all bits required to power up oscillators and synthesizers in both receive and duplex mode. The Enable2 configuration register contains all bits required to power up the complete receive and duplex modes (this register can be set to all '1's if preferred). The following words should therefore be programmed on the serial bus (Hex format): Receive register (0) 5DE200 Transmit register (1) 5DFFF1 26 Zarlink Semiconductor Inc. ZL20200 Enable1 Config. register (2) 188262 Enable2 Config. register (3) 5DFFF3 2.2 Data Sheet Operating Register Address 4 This registers selects internal setups for example IS136. The bits are assigned for control of receive and transmit bits as shown below: 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 RX<7:0> TX <11:0> Receive Set Up Transmit Set Up 8 7 6 5 4 3 2 1 0 0 1 0 0 Address The function of the receive bits is shown below: Register Bit No. Control Bit 23 RX<7> Receive DLL disabled Receive DLL enabled 22 RX<6> Bandpass Filter BW = +/- 20 kHz Bandpass Filter BW = +/- 16 kHz 21 RX<5> 20 RX<4> LO output = 900 MHz LO Output = 1900 MHz 19 RX<3> Receive output dc bias (I/Q) = 1.25 V Receive output dc bias (I/Q) = Vcc/2 18 RX<2> IS136 Mode IF1 Input enabled Not Used 17 RX<1> AMPS IS136 16 RX<0> IF Input 0 selected IF Input 1 selected Action if '0' Action if '1' Not Used. Set to ‘0’. Table 9 - Function of the Receive Bits Bit 23 RX<7> is only applicable when VCO divide by 2 mode is selected in register 5 27 Zarlink Semiconductor Inc. ZL20200 Data Sheet The function of the transmit bits is shown below: Register Bit No. Control Bit 15 TX<11> 14 TX<10> 13 TX<9> 12 TX<8> 11 TX<7> 10 TX<6> 9 TX<5> 8 TX<4> 7 TX<3> 900 MHz output 1900 MHz output 6 TX<2> Internal External transmit IF Filter 5 TX<1> IS136 baseband filters Not Used 4 TX<0> Transmit baseband filters selected Transmit baseband filters by-passed Action if '0' Action if '1' Transmit output stage gain control Control of RF Transmit output stage current with VGA control voltage. Nominal value for TX<11:4> is 101010 Table 10 - Function of the Transmit Bits Control bits TX<11:4> allow optimization of the transmit output stage. This allows variation of the decrease in supply current with decreasing agc voltage and also allows optimization depending on output power and linearity requirements. Figure 14 shows the variation of output stage supply current with agc voltage and the programmable characteristics. The maximum current, agc threshold and slope can be programmed. The minimum current is not programmable. TX<11:10> (bits 15,14) allow the gain of the transmit output stage to be varied in 3 dB steps as shown in the table below: TX<11> TX<10> Gain (dB) 0 0 -6 0 1 -3 1 0 Nominal 1 1 +3 Table 11 - Gain of the Transmit Output Stage 28 Zarlink Semiconductor Inc. ZL20200 Data Sheet Imax Icc Slope Imin Vagc Vth Figure 14 - Transmit Output Stage Current versus Gain Control TX<9:8> (bits 13:12) control the agc voltage (Vth) at which the output stage current starts reducing. Typical values are shown in the table below: TX<9> TX<8> Vth (V) 0 0 1.09 0 1 1.25 1 0 1.48 1 1 1.81 Table 12 - VGA Threshold Voltage TX<7:6> (bits 11,10) control the rate of current reduction as shown in Figure 14. Typical vales are shown in the below: TX<7> TX<6> Slope (mA/V) 0 0 65 0 1 75 1 0 90 1 1 105 Table 13 - VGA Current Reduction TX<5:4> (bits 9:8) adjust the maximum current (Imax) of the transmit output stage. The gain of the output stage is not changed. Typical values are shown in the table below: TX<5> TX<4> Current 0 0 25% 0 1 50% 1 0 Nominal 1 1 150% Table 14 - Output Stage Current 29 Zarlink Semiconductor Inc. ZL20200 Data Sheet Using these controls allows the performance of the output stage to be optimized under various conditions; for example, current cant can be reduced if non-linear operation is required. The nominal value recommended for TX<11:4> is 10101010. An example of setting up the control register (address 4) for various systems is shown below: Bit Name IS136 - (900) IS136 - (1900) AMPS 23 RX<7> 0 0 0 22 RX<6> 0 0 1 21 RX<5> 0 0 0 20 RX<4> 0 1 0 19 RX<3> 0 0 0 18 RX<2> 0 0 0 17 RX<1> 1 1 0 16 RX<0> 1 1 1 15 TX<11> 1 1 1 14 TX<10> 0 0 0 13 TX<9> 1 1 1 12 TX<8> 0 0 0 11 TX<7> 1 1 1 10 TX<6> 0 0 0 9 TX<5> 1 1 1 8 TX<4> 0 0 0 7 TX<3> 0 1 0 6 TX<2> 0 1 0 5 TX<1> 0 0 0 4 TX<0> 0 0 0 Comments Note 1 Note 2 Table 15 - Control Register Settings Note 1: Note 2: The setting for RX<3> is dependent on the optimum common mode input voltage of the analog to digital converter in the baseband. Selects external transmit IF filter if used. The following hex words are therefore recommended for the control register (address 4): IS136 (900) IS136 (1900) AMPS 03AA04 13AAC4 41AA04 30 Zarlink Semiconductor Inc. ZL20200 2.3 Data Sheet Synthesizer Register - Address 5 This register sets up LO options for receive and transmit and also UHF synthesizer set up. 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 0 UI RX LO2 Set Up UC DL UD TX LO Set Up UHF PLL Set Up 3 2 1 0 0 1 0 1 Address Bits 23,17,14 are also used for UHF PLL and LO set up. Bits 16,15 are not used and should be set to zero. 2.3.1 UHF PLL and LO Register Bit No. 23 Action if '0' Action if '1' UHF PLL input = 900 MHz UHF PLL input = 1900 MHz 17 Fractional N Compensation selected 14 UHF Doubler Selected 8 Fractional N Denominator - see table below 7 6 Not Used - Set to 0 5 UHF PLL Charge Pump Current - see table below 4 Table 16 - UHF PLL and LO Control Note 1: Note 2: Note 3: Note 4: Bit 14 is only effective if 1900 MHz mode has been selected (register 4 Bit 7). Bit 23 is only effective if 1900 MHz mode has been selected (register 4 Bit 7) and the UHF frequency doubler selected (Register 5 Bit 14). This control allows the use of the doubled frequency to be used as the input to the UHF PLL. Fractional N Denominator. Bits 8,7 select the fractional N denominator for the UHF PLL as shown below: <8> <7> Frac N Denom. 0 0 5 0 1 8 1 0 13 1 1 20 Table 17 - Fractional N Denominator 31 Zarlink Semiconductor Inc. ZL20200 2.3.2 Data Sheet UHF PLL Charge Pump Current Bits 5,4 select the charge pump current for the UHF PLL as shown below: <5> <4> Current (mA) 0 0 1.00 0 1 0.50 1 0 0.25 1 1 0.125 Table 18 - UHF PLL Charge Pump Current 2.3.3 Receive LO Set Up Register Bit No. Action if '0' Action if '1' 22 High side Rx second LO injection Low side Rx second LO injection 21 Rx second LO = VCO/2 Rx second LO = VCO/4 20 Rx LO phase detector polarity normal Rx LO phase detector polarity inverted 19 Receive VHF PLL Charge Pump Current - see table below 18 Table 19 - Receive LO Set Up Bits 19,18 select the charge pump current for the receive VHF PLL as shown below: <19> <18> Current (mA) 0 0 1.00 0 1 0.50 1 0 0.25 1 1 0.125 Table 20 - Receive VHF PLL Charge Pump Current 32 Zarlink Semiconductor Inc. ZL20200 2.3.4 Data Sheet Transmit LO Set Up Register Bit No. Action if '0' Action if '1' 15 Transmit DLL disabled Transmit DLL enabled 13 Low side Tx up-converter LO injection High side Tx up-converter LO injection 12 Tx second LO = VCO/2 Tx second LO = VCO/4 11 Tx LO phase detector polarity normal Tx LO phase detector polarity inverted 10 Transmit VHF PLL Charge Pump Current - see table below 9 Table 21 - Transmit LO Set Up Bits 10,9 select the charge pump current for the receive VHF PLL as shown below: <10> <9> Current (mA) 0 0 1.00 0 1 0.50 1 0 0.25 1 1 0.125 Table 22 - Transmit VHF PLL Charge Pump Current 2.4 23 Control Register - Address 6 22 21 20 19 0 17 16 15 14 13 12 11 10 9 8 7 6 5 4 0 BBG 2.4.1 18 TCXO PDF LPC Tx Gain R Mode Control 3 2 1 0 0 1 1 0 Address IS136 Baseband Gain Bits 22:21 can be used to vary the gain of the baseband output stages in IS136 mode only. The gain of the 60 kHz IF stage preceding the baseband mixer is also varied so that the overall gain of the device can be maintained if required. The nominal gain is 20 dB and the recommended setting is BBG<1:0> = 11 to minimize output dc offsets. BBG<1> Bit 22 BBG<0> Bit 21 IF Gain (dB) Baseband Gain (dB) Overall Gain (dB) 0 0 14 6 20 0 1 17 6 23 1 0 17 0 17 1 1 20 0 20 Table 23 - Baseband Gain 33 Zarlink Semiconductor Inc. ZL20200 2.4.2 Data Sheet TCXO Reference Selection Bits 20:19 are used to set the device to the required TCXO reference frequency. TCXO<1> Bit 20 TCXO<0> Bit 19 TCXO Frequency (MHz) 0 1 14.4 1 0 19.44 Table 24 - TCXO Reference Selection 2.4.3 Discriminator Output Filtering Bits 17:14 set up on chip filtering of the FM output signal and are therefore only used in AMPS mode. Two cascaded filters can be selected and the bandwidth can be set to 25 or 37.5 kHz cut-off. Bits 17,16 (PDF) select the filters and bits 15,14 set the cutoff frequency. <17> <16> <15> <14> Filter Selection 0 0 X X No filters 0 1 X X Filter 1 selected 1 0 X X Filter 2 selected 1 1 X X Filters 1 and 2 selected X X 0 0 Both filters 37.5 kHz X X 0 1 Filter 1 25 kHz, Filter 2 37.5 kHz X X 1 0 Filter 1 37.5 kHz, Filter 2 25 kHz X X 1 1 Both filters 25 kHz Table 25 - FM Discriminator Output Filter Control In IS136 mode Bits <17:14> should be set to 0000. It is recommended that if the additional discriminator filtering is required in AMPS mode then both filters should be used with 25 kHz bandwidth, i.e. Bits<17:14> should be set 1111. 34 Zarlink Semiconductor Inc. ZL20200 2.4.4 Data Sheet Transmit Baseband Gain Bits 13:11 set the transmit baseband gain as shown below: <13> <12> <11> Gain (dB) 0 0 0 0 0 0 1 3 0 1 0 6 0 1 1 9 1 0 0 12 Table 26 - Transmit Baseband Gain 2.4.5 Mode Control Bit 10 resets the contents of all registers to '0'. After the reset is complete bit 10 is also reset to '0'. Bits 9:4 allow TXRXB, ENABLE1 and ENABLE2 to be programmed by either the external pins or via the serial bus. This allows mode control to be either via the external pins or the serial bus. The default state is using the external pins as this allows more accurate timing of power control. Register Bit No. 9 Action if '0' Action if '1' Receive Register (0) selected Transmit Register (1) selected 8 Enable2 Configuration Register (3) selected 7 Enable1 Configuration Register (2) selected 6 TXRXB Pin (34) selected Serial Bus selected - Bit 9 5 Enable2 Pin (20) selected Serial Bus selected - Bit 8 4 Enable1 Pin (11) selected Serial Bus selected - Bit 7 Table 27 - Mode Control Bits 9:7 can only be used if the appropriate bits 6:4 have been set to disable the external pins. If serial mode has been selected then the operation of bits 9:7 is the same as the external TX RXB, ENABLE1 and ENABLE2 pins respectively. 2.5 Register Address 7 - Not Used 2.6 Test Mode Register - Address 8 This register is used for test purposes only and should not be used. 35 Zarlink Semiconductor Inc. ZL20200 2.7 23 Data Sheet UHF PLL Divider Programming Register - Address 9 22 21 20 19 18 17 16 15 14 13 12 11 10 M Counter Value 9 8 7 B Counter Value 6 5 4 A Counter Value 3 2 1 0 1 0 0 1 Address Bits 23:11 set M counter value (Bit 23 = MSB) Bits 10:8 set B counter value - max value = 7 (Bit 10 = MSB) Bits 8:4 set A counter value - max value = 8 (Bit 7 = MSB) The A counter is a 4 bit counter to enable correct fractional N operation. Valid values of A are in the range 1 to 8. Using the 64/65/72/73 four modulus prescaler the divide ratio (N) is given by: N = 64 * M + 8 * B + A Values of M, B, A can be easily calculated using the formulae in the synthesizer section. 2.8 23 UHF PLL Reference Divider and Fractional N Programming Register - Address 10 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 0 X Frac N Numerator 3 2 1 0 1 0 1 0 UHF PLL Reference Counter Value Address Bit 23 is unused and should be set to '0' Bits 22:18 set the fractional N numerator (Bit 22 = MSB) Bits 17:4 set the Reference counter value (Bit 17 = MSB) 2.9 Receive VHF PLL Divider Programming Register - Address 11 23 22 21 0 0 0 X X X 20 19 18 17 16 15 14 13 12 11 10 M Counter Value 9 8 7 6 5 4 A Counter Value Bits 20:8 set M counter value (Bit 20 = MSB) Bits 7:4 set A counter value - max value = 15 (Bit 7 = MSB) Using the 16/17 two modulus prescaler the divide value (N) is given by: N = 16 * M + A Values of M, A can be easily calculated using the formulae in the synthesizer section. 36 Zarlink Semiconductor Inc. 3 2 1 0 1 0 1 1 Address ZL20200 2.10 Data Sheet Receive VHF PLL Reference Divider Programming Register - Address 12 23 22 21 20 19 0 0 0 0 0 X X X X X 18 17 16 15 RS 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 0 0 Receive VHF PLL Reference Counter Value Address Bits 23:19 are unused and should be set to '0' Bit 18 selects common reference divider for VHF receive and transmit PLLs ('0' to select). If a common reference divider is selected then the transmit VHF reference divider is used which must be programmed in register 13. Bits 17:4 set the Reference divider value (Bit 17 = MSB) 2.11 Transmit VHF PLL Divider Programming Register - Address 13 23 22 21 0 0 0 X X X 20 19 18 17 16 15 14 13 12 11 10 9 8 7 M Counter Value 6 5 4 3 2 1 0 1 1 0 1 A Counter Value Address Bits 23:21 are unused and should be set to '0' Bits 20:8 set M counter value (Bit 20 = MSB) Bits 7:4 set A counter value - max value = 15 (Bit 7 = MSB) Programming is identical to that for the receive VHF PLL register 11. 2.12 Transmit VHF PLL Reference Divider Programming Register Address 14 23 22 21 20 19 18 0 0 0 0 0 0 X X X X X X 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 1 0 Transmit VHF PLL Reference Counter Value Address Bits 23:18 are unused and should be set to '0' Bits 17:4 set the Reference counter value (Bit 17 = MSB) 2.13 23 PLL Lock Detect & Fractional N Compensation Programming Register Address 15 22 21 20 19 18 17 16 15 Fractional N Compensation 2.13.1 14 13 12 UHF PLL Lock Count 11 10 9 8 Transmit VHF PLL Lock Count 7 6 5 4 Receive VHF PLL Lock Count 3 2 1 0 1 1 1 1 Address Fractional N Compensation Bits 23:16 set the value for fractional N compensation in the UHF PLL with bit 23 as MSB. The value for the compensation is dependent on a number of parameters which are described in the synthesizer section. 37 Zarlink Semiconductor Inc. ZL20200 2.13.2 Data Sheet PLL Lock detect counters These 4 bit counters count the consecutive comparison cycles where the lock detect circuit gives an in-lock result. When the counter reaches its programmed count then that PLL is deemed to have achieved full lock. This prevents spurious false in-lock signals while the PLL is achieving lock up. There are separate counters for the UHF, Rx VHF and Tx VHF PLLs which are programmed as shown above. Bits 15,11,7 are the MSB's for the UHF, Rx VHF and Tx VHF PLL lock detector counters respectively. A non zero value must be programmed for the lock detect to operate correctly. 3.0 Absolute Maximum Ratings Supply Voltage -0.3 to 3.6 V Voltage applied to any pin -0.3 to Vcc + 0.3 V Operating Temperature -40°C to 85°C Storage Temperature -55°C to 125°C Max Junction Temperature 125°C This device is sensitive to ESD. Most pins have an ESD rating greater than 2000 V (Human Body Model HBM), however some pins have limited protection (800 to 2000 V) in order to meet the RF performance requirements. Anti-static precautions should be used when handling this device. 4.0 Operating Conditions Device operation is guaranteed under the following conditions: Operating Conditions Condition Min. Value Type Max. Units General Supply Voltage 2.7 3.3 V Operating Temperature -40 +85 °C Logic Input Voltage High – VIH 0.8Vcc Volts Logic Input Voltage Low – VIL 0.2Vcc Volts TCXO Reference Frequency Frequency 14.4 MHz Frequency 19.44 MHz Receiver Receiver IF Frequency 70 215 38 Zarlink Semiconductor Inc. MHz Comments ZL20200 Data Sheet Operating Conditions (continued) Condition Min. Value Type Max. Units 215 MHz Comments Transmitter Transmit IF Frequency 50 I & Q common mode voltage 1.2 I & Q input voltage level V 1.5 V p-p Cellular band LO input level -15 -10 -5 dBm PCS band LO input level -15 -10 -5 dBm Cellular band LO frequency 900 1100 PCS1900 band frequency 1900 2200 0dB input buffer gain MHz Serial Control Timing See Figure 13 SDATA Set Up t1 20 ns SDATA Hold t2 20 ns SCLK Pulse Width t3 50 ns SLATCH Set up t4 20 ns SLATCH Pulse Width t5 50 ns SCLK Period t6 100 ns Power Control Set up t7 20 ns 39 Zarlink Semiconductor Inc. ZL20200 5.0 Data Sheet Electrical Characteristics The electrical characteristics are guaranteed under the following conditions unless stated otherwise. Vcc =3.0 V, T = 25°C, TCXO Ref Frequency = 19.44 MHz. Value Typ Max. Units 10 40 µA Logic inputs = 0 V or Vcc AMPS 32 38 mA Note 1, AGC = 1.6 V IS136 33 39 mA Note 1, AGC = 1.6 V 141 170 mA VGA = 2.4 V, Note 2 106 125 mA VGA = 1 V, Note 2 120 145 mA VGA = 2.4 V, Note 2 102 120 mA VGA = 1 V, Note 2 UHF PLL 12.5 15.0 mA Note 3 Receive VHF PLL 5.2 6.3 mA Transmit VHF PLL 4.9 6.0 mA 4 5 mA Note 4 4.5 5.5 mA 900 or 1900 Band Note 5 Input Current 10 nA Vin = 0 to Vcc Input Capacitance 10 pF 0.2Vcc Volts I out = 1 mA Volts I out = -1 mA Characteristics Min. Comments Supply Current Sleep Receive Operation Transmit Operation 900 MHz Output 1900 MHz Output Standby Operation Additional Circuits Frequency Doubler UHF LO Output Buffer Logic Inputs Lock Detect Output Output Voltage Low Output Voltage High 0.8Vcc TCXO Input 40 Zarlink Semiconductor Inc. ZL20200 Characteristics Input Resistance Min. Value Typ 10 Units 0.5 10 pF 2 V p-p Receiver - IS136 500 Max Voltage Gain 80 Min Voltage Gain 50 NF Gainmax Input V1dB Gainmin 101 IIP3 Gainmax 1500 91 W dB AGC = 2.4 V AGC = 0.3 V -13 5 dB 56 62 dB/V 104 dBµV Minimum gain 74 dBµV Max Gain +/- 0.5 dB +/- 2 ° 3 V p-p Output dc Offset +/-20 mV Receiver AMPS (Fixed Gain) All parameters are measured at an IF frequency of 135.06 MHz, Rx VCO = 270 MHz unless stated otherwise. Vagc = 1.6 V (Gain 20 dB below maximum) 500 1500 W Input Sensitivity 14 dBµV Noise Figure 12 dB Input IP3 93 dBµV Audio Output 900 RSSI Dynamic Range Accuracy 1000 1100 50 -3 mV dB +3 dB RSSI Slope 16 mV/dB Input Signal - Min 25 dBµV Input Signal - Max 75 dBµV Min RSSI Level Rs =800 Ω dB I/Q Quadrature Accuracy Input impedance AGC = 0.3 to 2 V 8 I/Q Amplitude Matching Output 1 dB Compression ac coupled All parameters are measured at an IF frequency of 135.06 MHz, Rx VCO = 270 MHz unless stated otherwise Input impedance Gain slope Comments kΩ Input Capacitance Input Sensitivity Max. Data Sheet 0.35 0.5 0.70 41 Zarlink Semiconductor Inc. Note 6 Note 7 ZL20200 Characteristics Max RSSI Level Data Sheet Min. Value Typ Max. Units 1.45 1.55 1.65 V RSSI Output Impedance 1 kΩ Bandpass Filter IS136 and AMPS Narrow bandwidth mode Centre Frequency 3 dB Bandwidth Comments 60 +/- 16 kHz +/- 18 kHz Stop Band Attenuation Relative to signal at 60 kHz 0 to 3 kHz 67 69 dB 3 kHz to 10 kHz 61 63 dB 10 kHz to 22 kHz 48 51 dB 38 kHz 18 20 dB 82 kHz 18 20 dB 98 kHz to 110 kHz 48 50 dB 110 kHz to 117 kHz 61 63 dB 117 kHz to 123 kHz 68 70 dB 123 kHz to 1.36 MHz 71 73 dB 1.36 MHz to 1.52 MHz 36 48 dB 1.52 MHz to 10 MHz 71 73 dB Image Attenuation 0 to -10 kHz 61 dB -10 kHz to -42 kHz 40 dB - 42 kHz to -78 kHz 30 - 78 kHz to -105 kHz 40 dB -105 kHz to -1.36 MHz 61 dB -1.36 MHz to -1.52 MHz 36 -1.52 MHz to -10 MHz 61 Gain Ripple 40 dB 48 dB dB 1.0 1.5 dB Transmitter 60 kHz +/- 12.5 kHz All parameters are measured at an IF frequency of 180.0 MHz, Tx VCO = 360 MHz unless stated otherwise 42 Zarlink Semiconductor Inc. ZL20200 Characteristics Data Sheet Min. Value Typ Max. Units -1 0 +1 dB Comments I & Q modulator I/Q Input Buffer Gain I/Q Input Buffer Gain 3 dB I/Q Input Buffer Gain 6 dB I/Q Input Buffer Gain 9 dB I/Q Input Buffer Gain 12 dB I & Q differential input resistance 80 kΩ I & Q Baseband Filter Attenuation (IS136/AMPS) dc - 12.5 kHz 0.5 dB 85 - 180 kHz 12 17 dB > 180 kHz 25 33 dB Carrier Suppression 30 40 dB Sideband Suppression 30 40 dB 45 60 dB IF Variable gain amplifiers Gain control range Control voltage for minimum gain 0.10 V Control voltage for maximum gain AGC control voltage slope 33 38 2.4 V 43 dB/V VGA = 0.5 to 1.2 V IF Output Filter (option) IF output impedance 500 W To external filter IF input impedance 1.5 kΩ From external filter IF output level 100 mV 800 MHz RF output stage Specifications assume 50 ohm load driven via a matching network. Output Frequency = 836 MHz, UHF LO = -10 dBm at 1016 MHz. RF amplifier operating frequency range 824 Output power +8 849 +10 MHz dBm 43 Zarlink Semiconductor Inc. ZL20200 Characteristics Min. ACPR (TDMA) Output power AMPS +10 Receive band noise (869 - 894 MHz) Value Typ Max. Data Sheet Units Comments -36 dBc Pout = +8 dBm, Offset = 30 kHz -56 dBc Pout = +8 dBm, Offset = 60 kHz +14 dBm -124 dBm/Hz ftx = 849 MHz Pout = +8 dBm With external IF filter Spurious Outputs LO Leakage -25 -21 dBc Pout = +8 dBm Image Rejection -27 -21 dBc Pout = +8 dBm -20 dBm Other Spurii 1900 MHz RF output stage (PCS) RF amplifier operating frequency range Output power Specifications assume 50 ohm load driven via a matching network Output Frequency = 1880 MHz, UHF LO = -10 dBm at 2060 MHz. 1.88 +8 ACPR (TDMA) Receive band noise (1930-1990 MHz) 1.91 GHz +10 dBm -36 dBc Pout = +8 dBm, Offset = 30 kHz -56 dBc Pout = +8 dBm, Offset = 60 kHz -128 dBm/Hz ftx = 1910 MHz, Pout = +8 dBm With external IF filter Spurious Outputs LO Leakage -30 -25 dBc Pout = +8 dBm Image Rejection -30 -25 dBc Pout = +8 dBm -20 dBm 2200 MHz Other Spurii UHF Synthesizer Input Frequency 800 Charge Pump Current 0.9 1 1.1 mA 0.45 0.5 0.55 mA 0.22 0.25 0.28 mA 0.11 0.125 0.14 mA Vdd - 0.4 V 15 % Charge Pump Output Compliance Charge Pump sink/source mismatch 0.4 44 Zarlink Semiconductor Inc. Less than +/-10% variation in Iout ZL20200 Characteristics Min. Charge Pump off-state current Fractional Compensation Value Typ Max. 5 88 98 Data Sheet Units Comments nA 108 µA Full Scale UHF Buffers Load Impedance 200 W Output Level (900 and 1900) -11 dBm Load = 200 ohms Harmonic Level -40 dBc LO1900 Output Rx and Tx IF Synthesizers Input Frequency 100 Charge Pump Current 0.9 Charge Pump Output Compliance 430 MHz 1 1.1 mA 0.45 0.5 0.55 mA 0.22 0.25 0.28 mA 0.11 0.125 0.14 mA Vcc - 0.4 V 15 % 0.4 Charge Pump sink/source mismatch Charge Pump off-state current 5 Less than +/-10% variation in Iout nA Rx LO Oscillator Frequency 140 Phase Noise 430 -99 MHz dBc/Hz Freq = 270 MHz, Offset = 30 kHz Tx LO Oscillator Frequency Phase Noise 260 430 -99 MHz dBc/Hz Freq = 360 MHz, Offset = 30 kHz Notes: Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: All receive currents include all receiver sections plus Rx VHF and UHF PLL's, and UHF LO input buffer circuits. The LO output buffer and frequency doubler are not included. All transmit currents include all transmit sections plus Tx VHF and UHF PLL's, and UHF LO input buffer circuits. The LO output buffer and frequency doubler are not included. Includes UHF LO input buffer. This is only applicable in 1900 MHz band. The UHF LO output buffer need only be powered up if required to drive an external circuit, for example, a receive front end mixer. Input signal FM modulated with 8 kHz deviation by 1 kHz modulating signal. Specification is minimum input level to obtain 12 dB SINAD at FM Output (pin 45) using CCITT filter. Input modulation: 1 kHz modulating signal with 8 kHz deviation. Output level at FM out (pin 45) is set by external components. See application section for details. 45 Zarlink Semiconductor Inc. ZL20200 6.0 Typical Performance Curves 6.1 Receive Data Sheet AMPS Rx. - Icc v Temperature IS136 Rx. - Icc v T emperature 35 38 34 37 36 33 35 mA mA 32 31 30 28 33 32 Vcc = 2.7V 29 34 Vcc = 3.0V 31 Vcc = 3.3V 30 27 Vcc = 2.7V Vcc = 3.0V Vcc = 3.3V 29 -40 25 T emperature °C 85 -40 Rx. Gain v AGC (Vcc) 85 Rx. Gain v AGC (Temperature) 120 120 100 100 80 80 60 60 dB dB 25 Temperature °C 40 Vcc = 2.7V 40 T = -40°C 20 Vcc = 3.0V 20 T = 25°C 0 Vcc = 3.3V 0 T = 85°C -20 -20 0 1 2 3 0 AGC Volts 1 2 AGC Volts 46 Zarlink Semiconductor Inc. 3 ZL20200 Data Sheet Rx. RSSI 1.6 1.4 RSSI Voltage 1.2 1 0.8 0.6 -40°C 0.4 25°C 0.2 85°C 0 -150 -100 -50 0 Input Level dBm 6.2 Transmit IS136 Tx. 900 MHz - Icc v AGC (Temperature) 180 180 160 160 140 140 120 120 100 100 Icc mA Icc mA IS136 Tx. 900 MHz - Icc v AGC (Vcc) 80 Vcc = 2.7V 60 Vcc = 3.0V 60 40 Vcc = 3.3V 40 20 80 -40°C 25°C 20 0 0 1 AGC Volts 2 85°C 0 3 0 1 2 AGC Volts 47 Zarlink Semiconductor Inc. 3 ZL20200 IS136 Tx.1900 MHz - Icc v AGC (Temperature) IS136 Tx. 1900 MHz - Icc v AGC (Vcc) 160 160 140 140 120 120 100 Icc mA 100 Icc mA Data Sheet 80 Vcc = 2.7V 60 -40°C 60 Vcc = 3.0V 40 80 25°C 85°C 40 Vcc = 3.3V 20 20 0 0 0 1 2 0 3 1 AGC Volts 20 20 10 10 0 0 -10 -10 -20 Vcc = 2.7V -40°C 25°C -40 Vcc = 3.3V -50 -20 -30 Vcc = 3.0V -40 3 IS136 Tx. 900 MHz - Power Out v AGC (Temp.) dBm dBm IS136 Tx. 900 MHz - Power Out v AGC (Vcc) -30 2 AGC Volts 85°C -50 -60 -60 0 1 2 0 3 1 2 AGC Volts AGC Volts 48 Zarlink Semiconductor Inc. 3 ZL20200 IS136 Tx 1900MHz - Power Out v AGC (Temp.) 20 20 10 10 0 0 -10 -10 dBm dBm IS136 Tx. 1900 MHz - Power Out v AGC (Vcc) Data Sheet -20 Vcc = 2.7V -30 -40°C -30 Vcc = 3.0V -40 -20 25°C -40 Vcc = 3.3V 85°C -50 -50 -60 -60 0 1 2 0 3 1 2 AGC Volts AGC Volts 49 Zarlink Semiconductor Inc. 3 L Package Code c Zarlink Semiconductor 2002 All rights reserved. ISSUE 1 2 ACN 211130 213841 DATE 16Jun01 12Dec02 APPRD. Previous package codes For more information about all Zarlink products visit our Web Site at www.zarlink.com Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable. However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink. This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request. Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system conforms to the I2C Standard Specification as defined by Philips. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright Zarlink Semiconductor Inc. All Rights Reserved. TECHNICAL DOCUMENTATION - NOT FOR RESALE