TDK ZPSA20-12

ZPSA20 Series
2 x 3.5” 14-22W AC-DC Power Supplies
Features
u Wide Range AC Input
u Low profile, Industry Standard Footprint
u Global Safety Agency Compliance
u Class B conducted EMI
Key Market Segments & Applications
Specifications
Model
Input Voltage range
(1)
Inrush Current
Input Current (115/230VAC)
Leakage Current
Hold Up Time (Typ)
Temperature Coefficient
Voltage Accuracy
Adjustment Range
Minimum Load
Load Regulation
Line Regulation
Ripple & Noise (2)
Short Circuit Protection
Overvoltage Protection
Efficiency
LED Indicator
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Certification
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxLxH)
Warranty
A
A
mA
ms
A
mV
V
%
°C
°C
g
mm
yrs
ZPSA20
85 - 264VAC (47 - 440Hz) or 120 - 370VDC
40A maximum at 240VAC input, 25°C ambient cold start
0.25 / 0.12
0.6mA maximum (264VAC, 60Hz)
8ms at 115VAC input
±0.05%/°C
±1%
None
None
±1% (10 - 100% load change)
±0.5% (100 - 240VAC line change)
1% or 50mV whichever is greater
Continuous - hiccup mode
110 - 130% of nominal (Zener clamp)
82% typical
Green LED = OK
0 to +70°C derate linearly to 37.5% load from 45 to 70°C
-20 to +85°C
10 - 95% RH
Convection
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
< 196.1 m/s2 (20G)
UL60950-1, CSA60950-1 (cUL), EN60950-1, CE Mark
EN55022-B, FCC Class B
EN61000-4-2, -3, -4, -5, -6, -8
100g
2 x 3.5 x 0.79 (including underside components)
Two Years
(1) Safety certified for 47 - 63Hz input only
(2) Measured with 0.1uF ceramic & 10uF electrolytic at 20MHz BW
1-800-526-2324 • www.us.tdk-lambda.com/lp/
152
Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZPSA20 Series
8
.13
0.240 6.10
Ø0
LED
ACL
0.150 3.81
1.700 43.18
ACN
1.203 30.56
2.000 50.80
+Vo
0.156 3.96
0.240 6.10
(4P
0.156 3.96
0.620 15.75
L)
0
3.5
0.156 3.96
Outline Drawings (ZPSA20xx/P)
0.312 7.92
Outline Drawings (ZPSA20)
-Vo
VR
Ø 0.039 1.00
Ø 0.071 1.80
3.020 76.70
0.079 2.00 max.
0.063 1.60
0.906[23.00]max.
3.200 81.28
3.500 88.90
0.173 4.40
0.150 3.80
0.150 3.81
All Dimensions are in inches[mm]
Tolerances Inches X.XXX +/-0.02
Millimeters X.XX +/-0.5
Model Selector
Model
ZPSA20-3R3
ZPSA20-5
ZPSA20-9
ZPSA20-12
ZPSA20-15
ZPSA20-24
Output (V)
3.3
5
9
12
15
24
Other Industrial Products
Maximum
Output (A)
4.4
4.4
2.45
1.8
1.4
0.92
Peak
Load(A) (3)
6.6
6.6
4.0
2.7
2.1
1.4
Output
Power (W)
14.5
22
22
22
21
22
KPSA
KM
ZPSA/ZPD/ZPT
ZWS
5 - 15W pcb mount
15 - 40W pcb mount medical
40 - 60W, single, dual and triple output
5 - 240W single output
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zpsa-series.htm
(3) Average not to exceed max power, <30s, 10% duty cycle
Options
Suffix
Description
Blank
/P
Molex connectors
PCB mount pins
1-800-526-2324 • www.us.tdk-lambda.com/lp/
153
Revision A5: Apr 2013