High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 ZSE ISE PSE Z I SE3 PS Z I SE 12 ZSP ISA2 IS ZSM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings are available. ∗ This photo shows 2 display colors simultaneously for product presentation purposes. In actual application, only one color is displayed at a time. Abnormal conditions can be detected at a glance! PRESSURE PRESSURE kPa OUT OUT SET PRESSURE kPa OUT SET PRESSURE kPa PRESSURE kPa OUT SET kPa OUT SET SET With One-touch fitting (ø4, ø6, ø5/32", ø1/4") Reduced dimensions in piping direction 17.8 mm reduction∗ 12.4 mm reduction∗ Straight type Elbow type 14.4 22.4 17.8 mm 32.2 12.4 mm 34.8 KQ2H06-M5 KQ2L06-M5 ∗ Comparison when One-touch fittings (KQ2H06-M5 / KQ2L06-M5) are connected to the piping ports (M5 x 0.8) 16-2-2 Space-saving improvement Economical use of space Old Model ZSE4E ISE4E Each displa y required its own pa Display calibration nel openin g. Old Model 40 ZSE ISE PSE Z I 126 PS New Model New Model ZSE30 ISE30 SE3 Z I Just one p anel openin g is required fo r st displays, w ackable hich can b e mounted e ithe or vertically r horizontally . SE 12 ZSP ISA2 This function allows uniformity in the numbers displayed. IS 34.5 ZSM More user-friendly controls PF2 Raised rubber button controls are clearly set apart, simple to operate, soft to the touch. IF 103.5 Compact p rofile Plug-type connectors take the burden out of wiring work and maintenance. Applicable panel thickness is up to 6 mm. (Panel mounting) High-precision With analog output resolution: 1/1000 In addition to the conventional voltage output type (1 to 5 V) Current output type (4 to 20 mA) is now available. • Convenient when longer wiring is required • Excellent noise resistance Variations Vacuum/Low pressure ZSE30 Switches for vacuum and positive pressure can be easily distinguished. The different display panel frame colors easily tell them apart. Vacuum/Low pressure (ZSE30) Blue Positive pressure (ISE30) Gray 1 MPa 100 kPa Rated pressure range Positive pressure ISE30 0 0 –100 kPa Setting/Display resolution Output Switch output 0.2 kPa 0.001 MPa NPN/PNP open collector (1 output) Analog output Voltage output: 1 to 5 V; Current output: 4 to 20 mA Current consumption 45 mA or less (70 mA or less for current output) Option Panel mount/Bracket 16-2-3 Data ® High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2 m) L For positive pressure ISE30 01 25 M For vacuum/low pressure ZSE30 01 25 M Option 2 Piping specifications 01 R 1/8 (With M5 female thread) T1 NPT 1/8 (With M5 female thread) C4H ø4 One-touch fitting ø5/32" One-touch fiting C6H ø6 One-touch fitting N7H ø1/4" One-touch fitting C4L ø4 One-touch fitting ø5/32" One-touch fitting C6L ø6 One-touch fitting N7L ø1/4" One-touch fitting Nil None Bracket A Straight type Output specifications 25 NPN output 65 PNP output 26 1 to 5 V output 28 4 to 20 mA output Panel mount B Elbow type Panel mount adapter + Front protective cover D Option Part No. When optional parts are required separately, use the following part numbers to place an order. Option Lead wire with connector Part no. Note ZS-27-A Bracket ZS-27-B Lead wire length: 2 m With mounting screws (M3 x 5L: 2 pcs.) With M3 x 8L (2 pcs.) Panel mount adapter ZS-27-C Panel mount adater + Front protective cover ZS-27-D 16-2-4 With M3 x 8L (2 pcs.) Unit specifications Nil With unit switching function M Fixed SI unit (International System of Units) Note) Note) Fixed unit: For vacuum/Low pressure: kPA For positive pressure: MPa High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 Specifications ZSE30 (Vacuum/Low pressure) ISE30 (Positive pressure) Rated pressure range –100.0 to 100.0 kPa 0.000 to 1.000 MPa Regulating pressure range –101.0 to 101.0 kPa –0.100 to 1.000 MPa Proof pressure 500 kPa 1.5 MPa Min. regulating unit 0.2 kPa 0.001 MPa Fluid Air, Inert gas, Non-flammable gas Power supply voltage 12 to 24 VDC, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 45 mA or less (at no load) Switch output Note 1) NPN or PNP open collector output: 1 output Max. load current 80 mA Max. applied voltage 30 V (With NPN output) Residual voltage 1 V or less (With load current of 80 mA) Response time 2.5 ms or less (Response time selections with anti-chattering function: 20, 160, 640, 1280 ms) Short circuit protection Yes Repeatability ±0.2% F.S. ±2 digit or less ±0.2% F.S. ±1 digit or less Note 2) Output voltage: 1 to 5 V ±2.5% F.S. or less (With rated pressure range) Linearity: ±1% F.S. or less, Output impedance: Approx. 1 kΩ Output current: 4 to 20 mA ±2.5% F.S. or less (With rated pressure range) Linearity: ±1% F.S. or less Maximum load impedance: 300 Ω with power supply voltage of 12 V; 600 Ω with power supply voltage of 24 V Minimum load impedance: 50 Ω Voltage output Analog output Hysteresis Note 3) Current output Hysteresis mode Window comparator mode Display PS Z I SE 12 ZSP ISA2 ZSM Environmental resistance Piping Specifications Weight SE3 3 1/2 digit, 7-segment indicator, 2-color display (Red and green) Sampling cycle: 5 times/s Note 1) When switch output is selected, analog output is not available. Note 2) When voltage output is selected, a simultaneous selection of switch output and current output is not available. Note 3) When current output is selected, a simultaneous selection of switch output and voltage output is not available. 01 T1 C4H C6H N7H C4L C6L N7L R 1/8 M5 x 0.8 NPT 1/8 M5 x 0.8 — — — — — — One-touch fitting Straight type — — ø4 mm ø5/32 inch ø6 mm ø1/4 inch — — — One-touch fitting Elbow type — — — — — ø4 mm ø5/32 inch ø6 mm ø1/4 inch Wetted part material Z I IS ±2% F.S. ±2 digit ±2% F.S. ±1 digit (at 25°C ambient temperature) (at 25°C ambient temperature) Light up when output is ON (Green) Indicator light ±2% F.S. or less (based on 25°C) Temperature characteristics IP40 Enclosure Operating temperature range Operating: 0 to 50°C, Stored: –10 to 60°C (No freezing or condensation) Operating and stored: 35 to 85% RH (No condensation) Operating humidity range 1000 VAC for 1 min. between live parts and enclosure Withstand voltage 50 MΩ or more between live parts and enclosure (at 500 VDC) Insulation resistance 10 to 150 Hz, 1.5 mm or 20 m/s2 amplitude in X, Y, Z directions for 2 hours each Vibration resistance 100 m/s2 in X, Y, Z directions 3 times each Impact resistance Compliant with CE Marking and UL (CSA) standards Standard Port size PSE Adjustable (can be set from 0) Display accuracy Part ZSE ISE Sensor pressure receiving area: Silicon, Piping port: C3602 (Electroless nickel plated), O-ring: HNBR O-ring: NBR, fitting: PBT O-ring: NBR With lead wire with connector (2 m) 81 g 76 g 78 g Without lead wire with connector 43 g 38 g 40 g 16-2-5 PF2 IF Data Series ZSE30/ISE30 Setting Pressure setting Press the SET button. Enter the set value of the pressure to perform switch output. Measuring mode Press the SET button. Initial setting Set the output type, response time, and display color switching. Press the SET button and hold for 2 sec. or longer. Measuring mode Detects and displays the pressure and performs switch operations. Other functions such as the value clear function can be set according to the application purpose. Press the SET button. Initial Setting Initial setting mode Press and hold the SET button for 2 seconds or longer. Display monitor will be per Figure A below, and the switch will now be in the display color setting mode. PRESSURE 3. Output type setting The type of switch output can be set arbitrarily. While the current output type is displayed, press the DOWN button to switch between normally open and normally closed . PRESSURE PRESSURE OUT Figure A OUT OUT If the unit specification indicated at the time of ordering is “M”, the fixed SI unit will be used. If it is Nil, refer to “Unit Switching Function” on page 16-2-8. Normally closed Normally open Press the SET button to set the output type and proceed to the response time setting. 4. Response time setting 1. Display color setting Select the color for LCD display. Press the UP or DOWN button to choose a display color. PRESSURE PRESSURE The switch output response time can be set arbitrarily. Chattering can be prevented with a response time setting. While the current response time is displayed, press the UP or DOWN button to select a new response time. PRESSURE OUT PRESSURE PRESSURE OUT ON: Red ON: Green PRESSURE OUT PRESSURE OUT 2.5 ms OUT 20 ms 160 ms PRESSURE OUT ON/OFF: Red ON/OFF: Green Press the SET button to set the color and proceed to the operating mode setting. If the analog output is set, press the UP or DOWN button and select the desired display color from (Green) or (Red). Press the SET button to exit this mode and return to the measuring mode. 2. Operating mode setting This mode will let you select the switch operating mode. While the current operating mode is displayed, press the UP or DOWN button to select a newly desired operating PRESSURE PRESSURE OUT OUT 640 ms 1280 ms Press the SET button to set the response time and proceed to the auto preset setting. If the operating mode is the window comparator mode, press the SET button to return to the measuring mode. 5. Auto preset setting This function stores the measuring pressure that is set during the auto preset mode as a basic value. While the current setting is displayed, press the UP or DOWN button to select it as an auto preset setting. PRESSURE PRESSURE OUT OUT Hysteresis mode ON Window comparator mode ON OFF ON OFF P1 ON OFF n1 (Standard: Factory setting) (Reversed) Hysteresis Hysteresis (H) (H) Hysteresis Hysteresis (H) (H) Hysteresis (H) Hysteresis (H) OFF P1 P2 (Standard: Factory setting) n1 n2 (Reversed) Press the SET button to set the mode and proceed to the output type setting. 16-2-6 PRESSURE OUT OUT OUT Manual Auto Press the SET button to set the auto preset and return to the measuring mode. High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 Pressure setting Auto preset setting Manual setting Press the SET button in the measuring mode to display the set value. and the current set value blink alternately. PRESSURE OUT Normally Open Alternately displayed PRESSURE 1. Auto preset preparation mode While in the measuring mode, press the SET button to activate the auto preset preparation mode, and will be displayed. Proceed to prepare the devices to perform the pressure setting. While is still displayed, press both the UP and DOWN buttons simultaneously to return to the measuring mode. PRESSURE OUT Press the SET button to display the next set value. Press the UP or DOWN button to change the value. (Refer to “How to Set Value” on the lower right hand corner of this page.) 2. Auto preset setting Press the SET button to activate the mode to execute auto preset functions. When is displayed, start the system operation and change the pressure. The set value will be automatically detected and stored. While is still displayed, press the SET button to complete the setting and return to the normal measuring mode. Hysteresis mode Window comparator mode In this mode, P2 and the current set value are displayed alternately after setting P1. Press the SET button to display the next set value ( : hysteresis). Press the UP or DOWN button to change the value. (Refer to “How to Set Value” at right.) Next, and the set value for hysteresis will be displayed alternately. Press the SET button to return to the normal measuring mode. Press the UP or DOWN button to change the value. (Refer to “How to Set Value” at right.) Pressure set value can be verified without holding or stopping the switch output operation. Z I SE 12 ZSP ISA2 IS PRESSURE In this mode, hysteresis (H) and the set value for hysteresis are displayed alternately after setting P1. Press the SET button to return to the normal measuring mode. Press the UP or DOWN button to change the value. (Refer to “How to Set Value” below right.) SE3 PS OUT Normally Closed PSE Z I PRESSURE OUT ZSE ISE ZSM PF2 OUT IF How to Set Value To enter a value such as the one for pressure setting: 1. Press the UP or DOWN button to change the set value. The first digit blinks. 1st digit 2. Press the UP or DOWN button to set the value arbitrarily. (If there is no button operation for more than 10 seconds, the current value will be automatically set and the function will return to the set value display mode.) 3. With every push of the SET button, the next (higher) digit blinks. 2nd digit 3rd digit When the left-most digit is zero, “ ” or “ ” will blink. If the SET button is pressed while the left-most digit is blinking, the right-most digit will now blink. 4. Press and hold the SET button for 1 second or longer to return to the set value display mode. 16-2-7 Data Series ZSE30/ISE30 Setting Function setting Display calibration Key lock function During measuring mode, press the SET and DOWN buttons simultaneously and hold for 2 seconds or longer. and current measured value will be displayed. Press the UP or DOWN button to change the set value. If there is no button operation for more than 2 seconds after changing the set value, the display mode returns to displaying and the current measured value. PRESSURE Alternately displayed Selection of lock and unlock OUT OUT Current measured value Press the SET button to display the adjusted value (percent). The adjusted value and will be alternately displayed. PRESSURE Measuring mode Press the SET button SET and hold for 4 sec. or longer Lock Unlock Measuring mode PRESSURE This function prevents incorrect operations such as changing the set value accidentally. Press the SET button and hold for 4 seconds or longer to display the current or setting. Press the UP or DOWN button to select the setting and set this function with the SET button. Use the mode to avoid accidental button operation. To release a key lock function, press the SET button and hold for 4 seconds or longer to display the current setting, and select the mode. PRESSURE Alternately displayed Zero out (Zero ADJ) function OUT OUT Adjusted value (Percent) Press the SET button to return to the normal measuring mode. PRESSURE This function clears and resets the displayed value as long as the measuring pressure is within ±70 digits of the atmospheric pressure. (Due to individual product differences, the setting range varies ±10% F.S.) This function is effective in detecting pressure fluctuations that exceed a certain amount without being affected by the supply pressure. Press and hold the UP and DOWN buttons simultaneously to reset the display. Release the buttons to return to the measuring mode. OUT Displayed pressure value This function eliminates slight differences in the output values and allows uniformity in the numbers displayed. Displayed values of the pressure sensor can be calibrated to within ±5% for Series ISE and ±2.5% for Series ZSE. ±5% R.D. (±2.5% R.D.) Unit Conversion Function + 0 Applied pressure : Factory setting display value set prior to shipment : Display calibration range Note) When the display calibration function is used, the regulating pressure value may change ±1 digit. Peak/Bottom hold function This function constantly detects and updates the maximum and minimum pressure values and allows to hold the display value. To use a peak hold function, press and hold the UP button for 1 second or longer. The maximum pressure value is held and blinks repeatedly. Press and hold the UP button again for 1 second or longer to release this function and return to the measuring mode. To use a bottom hold function, press the DOWN button for 1 second or longer. The minimum pressure value is held and blinks repeatedly. Press and hold DOWN button again for 1 second or longer to release this function and return to the measuring mode. 16-2-8 Measuring mode + Press and hold for 1 second or longer. When not selecting “M” for unit specification Desired display unit can be selected. Press the UP or DOWN button to switch the unit, and the set value is automatically converted. The conversion order is: PA⇔GF⇔bAr⇔PSi⇔inH⇔mmH Press the SET button to set the unit and proceed to the display color setting. For vacuum/low pressure Pa⇔kgf/cm2⇔bar⇔psi⇔inchHg⇔mmHg For positive pressure MPa⇔kgf/cm2⇔bar⇔psi Indication of Units Displayed unit Pa kgf/cm2 bar psi mmHg inchHg ISE30 ZSE30 0.001 MPa 0.01 0.01 0.2 — — 0.2 kPa 0.002 0.002 0.05 2 0.2 High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 Description Indication light (Green) LCD display Displays the switch operation status. PRESSURE MPa UP button OUT SET Use this button to change the mode or increase the ON/OFF set value. It also allows you to switch to the peak value display mode. SET button Use this button to switch the mode and set the set value. Displays the current pressure condition, setting mode conditions, selected display unit, and error codes. A display color type can be selected from either a single color display with red or green, or 2-color display in which green and red are switched according to the output. ZSE ISE PSE DOWN button Z I Use this button to change the mode or decrease the ON/OFF set value. It also allows you to switch to the bottom value display mode. SE3 PS Z I SE 12 ZSP ISA2 Error Correction Example of Internal Circuit and Wiring Take the following corrective solutions when errors occur. -25 NPN open collector output Maximum 30 V, 80 mA Residual voltage: 1 V or less Solution overcurrent error Shut off the power supply. After eliminating the output factor that Load current of switch output is more than 80 mA. caused the excess current, turn the power supply back on. Residual pressure error Pressure is applied during the zero out operation as follows: When the switch for positive pressure is used: ±0.071 MPa or more. When the switch positive pressure is used: ±7.1 kPa or more. After displaying for 3 seconds, it will return to the measuring mode. Due to the individual product difference, the setting range varies ±10% F.S. PF2 Brown DC(+) Main circuit Condition ZSM IF Load + Black OUT – 12 to 24 VDC Blue DC(–) Bring the pressure back to atmospheric pressure and try using the zero out function. -26 Analog output type 1 to 5 V (±2.5% F.S.) Output impedance: 1 kΩ Brown DC(+) Main circuit Error LCD description display IS Black OUT (Analog output) Load + – 12 to 24 VDC Blue DC(–) Supply pressure is below the minimum regulating pressure. Reduce/Increase supply pressure to within the regulating pressure range. -28 Analog output type 4 to 20 mA (±2.5% F.S.) Maximum load impedance: Power supply voltage 12 V: 300 Ω Power supply voltage 24 V: 600 Ω Minimum load impedance: 50 Ω Internal data error Brown DC(+) Main circuit Applied pressure error Supply pressure exceeds the maximum regulating pressure. Black OUT (Analog output) Load 12 to – 24 VDC + Blue DC(–) System error Internal data error Internal data error Shut off the power supply. Turn the power supply back on. If the power should not come back on, please contact SMC for an inspection. -65 PNP open collector Maximum 80 mA Brown DC(+) Main circuit Internal data error 12 to – 24 VDC + Black OUT Load Blue DC(–) 16-2-9 Data Series ZSE30/ISE30 Dimensions 30 25 8 9.5 Lead wire with connector 3.6 M5 x 0.8 Wi dth SET 01: R 1/8 T1: NPT 1/8 C øB øB Straight Elbow With One-touch fitting 15 10 42.5 With bracket 4.2 sf lat s1 2 A A 3 22 30 20 20 25 1.8 30 45 SMC 16-2-10 ac ros 1.5 35 20 ±0.1 SMC OUT 2-M3 x 0.5 Thread depth 4 MPa 10 PRESSURE 20 ±0.1 35 One-touch fitting size ø4, ø5/32" ø6 ø1/4" Straight A B 14.4 11.2 (mm) Elbow C B A 10.4 18 20 22.4 12.8 20 22.8 13.2 20.5 High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 Dimensions Panel mount ZSE ISE PSE 7.2 17.8 8 Z I 9.5 34.5 Z I R4 MPa R4 ZSP ISA2 SET SE 12 .5 .5 OUT SE3 PS 21 PRESSURE 47.8 MADE IN JAPAN IS 8.75 Panel thickness 0.5 to 6 ZSM PF2 IF Panel mount adapter + Front protective cover Data 42.4 11 17.8 8 9.5 34.5 Panel thickness 0.5 to 6 16-2-11 Series ZSE30/ISE30 Dimensions Panel fitting dimension Multiple (2 pcs. or more) horizontal mounting PRESSURE PRESSURE MPa OUT SET SET 31 x n pcs. + 3.5 x (n pcs. – 1) 24 and up 0 31 –0.4 0 31 –0.4 MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN Multiple (2 pcs. or more) vertical mounting 0 31–0.4 PRESSURE 24 and up MPa PRESSURE SET MPa OUT SET PRESSURE MPa 31 x n pcs. + 3.5 x (n pcs. – 1) OUT MADE IN JAPAN MADE IN JAPAN OUT 16-2-12 SET MPa OUT SET OUT PRESSURE MPa MADE IN JAPAN 1-pc. mounting Series ZSE30/ISE30 Specific Product Precautions 1 Be sure to read before handling. Handling Operating Environment 1. Do not drop, bump, or apply excessive impacts (980 m/s2) while handling. Although the body of the sensor may not be damaged, the internal parts of the sensor could be damaged and lead to a malfunction. 2. The tensile strength of the cord is 35 N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor––do not dangle it from the cord. 3. Do not exceed the screw-in torque of 7 to 9 N⋅m when installing piping. Exceeding this value may cause malfunctioning of the sensor. 4. Do not use pressure sensors with corrosive and/or flammable gases or liquids. 5. Allow a sufficient margin of tube length in piping in order to prevent application of torsional, tensile or moment load to the tubes and fittings. 6. When a brand of tubing other than SMC is used, make sure that the tolerance of the tube’s O.D. satisfies the following specifications. 1. Our pressure switches are CE marked; however, they are not equipped with surge protection against lightning. Lightning surge countermeasures should be applied directly to system components as necessary. 2. Our pressure switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 3. Do not use in an environment where static electricity can cause problems, otherwise system failure or malfunction may result. Warning Warning 1) Nylon tubing: ±0.1 mm or less 2) Soft nylon tubing: ±0.1 mm or less 3) Polyurethane tubing: +0.15 mm or less, –0.2 mm or less 7. The applicable fluid is air. Please consult with SMC if the switch is to be used with other types of fluids. Connection Warning 1. Incorrect wiring can damage the switch and cause a malfunction or erroneous switch output. Connections should be done while the power is turned off. 2. Do not attempt to insert or pull the pressure sensor or its connector when the power is on. A switch output malfunction may occur. 3. Wire separately from power lines and high voltage lines, avoiding wiring in the same conduit with these lines. Malfunctions may occur due to noise from these other lines. 4. If a commercial switching regulator is used, make sure that the F.G. terminal is grounded. ZSE ISE PSE Z I SE3 PS Z I SE 12 ZSP ISA2 IS Mounting ZSM Caution PF2 1. Mounting with panel mount adapter IF Data Panel mount adapter Panel mount adapter Panel To release push the clips outward as shown on the picture, and pull back towards you. Claw 2. Mounting with bracket Mount a bracket to the body using two M3 x 5L mounting screws and install on piping with hexagon socket head cap screws. The switch can be installed horizontally depending on the installation location. Mounting screw M3 x 5L Bracket Tightening torque for bracket mounting screw should be 0.5 to 0.7 N⋅m. 16-2-13 Series ZSE30/ISE30 Specific Product Precautions 2 Be sure to read before handling. Connection/Removal of Connector Piping • To connect the connector, insert it straight while pinching the lever, and then push the lever into the jack of the housing and lock it. • To remove the connector, pull it straight out while applying pressure with your thumb to the lever and unhooking it from the jack. • Cut the tube perpendicularly. • Hold the tube and insert it into the One-touch fitting carefully and securely all the way to the bottom. Tube Lever DC polarity indicator Lead wire (Brown) One-touch fitting Lead wire (Black) Lead wire (Blue) • Do not attempt to insert or pull the pressure sensor or its connector when the power is on. A switch output malfunction may occur. Regulating Pressure Range and Rated Pressure Range Caution Set the pressure within the rated pressure range. The regulating pressure range is the range of pressure that is possible in setting. The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.) on the sensor. Although it is possible to set a value outside the rated pressure range, the specifications will not be guaranteed even if the value stays within the regulating pressure range. Pressure range Switch –100 kPa For vacuum/ low pressure ZSE30 For positive pressure ISE30 0 –100 kPa 1 MPa 101 kPa 0 (–0.1 MPa) 500 kPa 100 kPa –101 kPa –100 kPa 100 kPa 1 MPa 1 MPa Rated pressure range of switch Regulating pressure range of switch 16-2-14 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices. Caution : Operator error could result in injury or equipment damage. Warning : Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possible result of serious injury or loss of life. Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems. Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. 2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4. Contact SMC if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 16-14-3 Common Precautions Be sure to read before handling. For detailed precautions on every series, refer to main text. Selection Warning 1. Confirm the specifications. Products represented in this catalog are designed for use in compressed air appllications only (including vacuum), unless otherwise indicated. Do not use the product outside their design parameters. Please contact SMC when using the products in applications other than compressed air (including vacuum). Mounting Warning 1. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. 4. Use clean air If the compressed air supply is contaminated with chemicals, cynthetic materials, corrosive gas, etc., it may lead to break down or malfunction. Operating Environment Warning 1. Do not use in environments where the product is directly exposed to corrosive gases, chemicals, salt water, water or steam. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not use in a place subject to heavy vibrations and/or shocks. 4. Do not mount the product in locations where it is exposed to radiant heat. Maintenance 2. Securing the space for maintenance When installing the products, please allow access for maintenance. 3. Tightening torque When installing the products, please follow the listed torque specifications. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping. Also, when the pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. Air Supply Warning 1. Operating fluid Please consult with SMC when using the product in applications other than compressed air (including vacuum). Regarding products for general fluid, please ask SMC about applicable fluids. 2. Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines. If the drain bowl is difficult to check and remove, it is recommended that a drain bowl with the auto-drain option be installed. For compressed air quality, refer to “Air Preparation Equipment” catalog. 16-14-4 Warning 1. Maintenance procedures are outlined in the operation manual. Not following proper procedures could cause the product to malfunction and could lead to damage to the equipment or machine. 2. Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling and repair of pneumatic systems should be performed by qualified personnel only. 3. Drain flushing Remove drainage from air filters regularly. (Refer to the specifications.) 4. Shut-down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on. 5. Start-up after maintenance and inspection Apply operating pressure and power to the equipment and check for proper operation and possible air leaks. If operation is abnormal, please verify product set-up parameters. 6. Do not make any modifications to be product. Do not take the product apart. Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout the world to use our products with even greater confidence, SMC has obtained certification for international standards “ISO 9001” and “ISO 14001”, and created a complete structure for quality assurance and environmental controls. SMC products pursue to meet its customers’ expectations while also considering company’s contribution in society. SMC’s quality control system Make customers our first priority, offering them reliable and friendly service. Produce the highest quality with the participation of all employees. Create new products using the latest technology, and offer the finest products in a timely manner. Quality policies Market research Product planning After service Sales coordination Quality management system ISO 9001 This is an international standard for quality control and quality assurance. SMC has obtained a large number of certifications in Japan and overseas, providing assurance to our customers throughout the world. Quality system education Training of suppliers Research Education Design Training Development Production New product evaluation Reliability design Reliability testing New technical development Process control Inspection, testing, etc. Initial production control Quality control activities Environmental management system ISO 14001 This is an international standard related to environmental management systems and environmental inspections. While promoting environmentally friendly automation technology, SMC is also making diligent efforts to preserve the environment. 16-14-5 SMC Product Conforming to Inter SMC products complying with EN/ISO, CSA/UL standards are supporting CE Mark The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied. It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and components are exported to the member Nations of the EU. Once “A manufacturer himself” declares a product to be safe by means of CE marking (declaration of conformity by manufacturer), free distribution inside the member Nations of the EU is permissible. CE Mark SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in accordance with CETOP (European hydraulics and pneumatics committee) guide lines. As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark, Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg EC Directives and Pneumatic Components • Machinery Directive The Machinery Directive contains essential health and safety requirements for machinery, as applied to industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File required for a Declaration of Conformity. • Electromagnetic Compatibility (EMC) Directive The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission). • Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. • Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L. Such vessels require EC type examination and then CE marking. 16-14-6 SMC Product Conforming to International Standards national Standards you to comply with EC directives and CSA/UL standards. Mark of compliance for CSA/UL Mark of compliance for CSA CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with electric products. Both UL and CSA standards are acknowledged in North America as the first class certifying body. They have a long experience and ability for issuing product safety certificate. Products approved by CSA or UL standards are accepted in most states and governments beyond question. Since CSA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the jurisdiction of Occupational Safety and Health Administration (OSHA), SMC was tested for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards. The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards. TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation. Products conforming to CE Standard With CE symbol for simple visual recognition In this catalog each accredited product series is indicated with a CE mark symbol. However, in some cases, every available models may not meet CE compliance. Please visit our web site for the latest selection of available models with CE mark. http://www.smcworld.com 16-14-7 SMC’s Global Service Network America Europe U.S.A. SMC Corporation of America 3011 North Franklin Road Indianapolis, IN 46226, U.S.A. TEL: 317-899-4440 FAX: 317-899-3102 U.K. SMC Pneumatics (U.K.) Ltd. Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K. TEL: 01908-563888 FAX: 01908-561185 CANADA SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 905-812-0400 FAX: 905-812-8686 GERMANY SMC Pneumatik GmbH Boschring 13-15 D-63329 Egelsbach, Germany TEL: 06103-4020 FAX: 06103-402139 MEXICO SMC Corporation (Mexico), S.A. DE C.V. Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 ITALY SMC Italia S.p.A. Via Garibaldi 62 I-20061 Carugate Milano, Italy TEL: 02-9271365 FAX: 02-9271365 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaña 1,115 km. 16,5 P. Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 ARGENTINA SMC Argentina S.A. Teodoro Garcia 3860 (1427) Buenos Aires, Argentina TEL: 011-4555-5762 FAX: 011-4555-5762 BOLIVIA SMC Pneumatics Bolivia S.R.L. Avenida Beni Numero 4665 Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia TEL: 591-3-3428383 FAX: 591-3-3449900 VENEZUELA SMC Neumatica Venezuela S.A. Apartado 40152, Avenida Nueva Granada, Edificio Wanlac, Local 5, Caracas 1040-A, Venezuela TEL: 2-632-1310 FAX: 2-632-3871 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 SWEDEN SMC Pneumatics Sweden AB Ekhagsvägen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 SWITZERLAND SMC Pneumatik AG Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland TEL: 052-396-3131 FAX: 052-396-3191 AUSTRIA SMC Pneumatik GmbH (Austria) Girakstrasse 8, A-2100 Korneuburg, Austria TEL: 0-2262-6228-0 FAX: 0-2262-62285 SPAIN SMC España, S.A. Zuazobidea 14 Pol. Ind. Júndiz 01015 Vitoria, Spain TEL: 945-184-100 FAX: 945-184-510 PERU (Distributor) IMPECO Automatizacion Industrial S.A. AV. Canevaro 752, Lince, Lima, Peru TEL: 1-471-6002 FAX: 1-471-0935 IRELAND SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland TEL: 01-403-9000 FAX: 01-466-0385 URUGUAY (Distributor) BAKO S.A. Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay TEL: 2-401-6603 FAX: 2-409-4306 NETHERLANDS (Associated company) SMC Pneumatics BV De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands TEL: 020-5318888 FAX: 020-5318880 BRAZIL SMC Pneumaticos Do Brasil Ltda. Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P. CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogotá, Colombia TEL: 1-424-9240 FAX: 1-424-9260 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 16-14-20 SMC’s Global Service Network Europe Oceania/Asia FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. 14-18 Hudson Avenue Castle Hill NSW 2154, Australia TEL: 02-9354-8222 FAX: 02-9894-5719 NORWAY SMC Pneumatics Norway A/S Vollsveien 13C, Granfoss Næringspark N-1366 LYSAKER, Norway TEL: 67-12-90-20 FAX: 67-12-90-21 NEW ZEALAND SMC Pneumatics (New Zealand) Ltd. 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 09-573-7007 FAX: 09-573-7002 BELGIUM (Distributor) SMC Pneumatics N.V./S.A. Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland TEL: 022-548-5085 FAX: 022-548-5087 HONG KONG SMC Pneumatics (Hong Kong) Ltd. 29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon, Hong Kong TEL: 2744-0121 FAX: 2785-1314 TURKEY (Distributor) Entek Pnömatik San.ve Tic. Ltd. Sti Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Türkiye TEL: 0212-221-1512 FAX: 0212-221-1519 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St. Petersburg 199004, Russia TEL: 812-118-5445 FAX: 812-118-5449 CZECH SMC Industrial Automation CZ s.r.o. Hudcova 78a, CZ-61200 Brno, Czech Republic TEL: 05-4121-8034 FAX: 05-4121-8034 HUNGARY SMC Hungary Ipari Automatizálási kft. Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 ROMANIA SMC Romania S.r.l. Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania TEL: 01-3205111 FAX: 01-3261489 SLOVAKIA SMC Priemyselná automatizáciá, s.r.o Nova 3, SK-83103 Bratislava TEL: 02-4445-6725 FAX: 02-4445-6028 SLOVENIA SMC Industrijska Avtomatilca d.o.o. Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia TEL: 07388-5240 FAX: 07388-5249 SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd. P.O.Box 240 Paardeneiland 7420 South Africa TEL: 021-511-7021 FAX: 021-511-4456 EGYPT (Distributor) Saadani Trading & Ind. Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 PHILIPPINES SHOKETSU SMC Corporation Unit 201 Common Goal Tower, Madrigal Business Park, Ayala Alabang Muntinlupa, Philippines TEL: 02-8090565 FAX: 02-8090586 MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam Selangor, Malaysia TEL: 03-56350590 FAX: 03-56350602 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 CHINA SMC (China) Co., Ltd. 7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China TEL: 010-67882111 FAX: 010-67881837 THAILAND SMC Thailand Ltd. 134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand TEL: 02-963-7099 FAX: 02-501-2937 INDIA SMC Pneumatics (India) Pvt. Ltd. D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar, U.P. 201 305, India TEL: (0120)-4568730 FAX: 0120-4568933 INDONESIA (Distributor) P.T. Riyadi Putera Makmur Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia TEL: 021-625 5548 FAX: 021-625 5888 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 16-14-21