ETC ZUS31205

Home > Product Details
ZUS3
Features
UL recognized, TV approved, CSA certified
Isolated between input-output
Thin profile
Built-in Over Current Protection
RoHS Compliant
5 year warranty(refer to Instruction Manual)
Input
Voltage
[V]
Output
Wattage
[W]
DC
Output
[V/A]
ZUS30505
DC 4.5 - 9
3
5V
0.6A
ZUS30512
DC 4.5 - 9
3
12V
0.25A
ZUS30515
DC 4.5 - 9
3
15V
0.2A
ZUS31205
DC 9 - 18
3
5V
0.6A
ZUS31212
DC 9 - 18
3
12V
0.25A
ZUS31215
DC 9 - 18
3
15V
0.2A
ZUS32405
DC 18 - 36
3
5V
0.6A
ZUS32412
DC 18 - 36
3
12V
0.25A
ZUS32415
DC 18 - 36
3
15V
0.2A
ZUS34805
DC 36 - 72
3
5V
0.6A
ZUS34812
DC 36 - 72
3
12V
0.25A
ZUS34815
DC 36 - 72
3
15V
0.2A
Model
Ordering information
On-board type
ZUS3
ZU
1
S
2
3
3
12
4
DC OUTPUT
5
1Series name
2Single output
3Output wattage
4Input voltage
5Output voltage
R
MODEL
MAX OUTPUT WATTAGE[W]
05
ZUS30505
3
VOLTAGE[V] 5
CURRENT[A] 0.60
ZUS30512
3
12
0.25
ZUS30515
3
15
0.20
ZUS31205
3
5
0.60
ZUS31212
3
12
0.25
ZUS31215
3
15
0.20
ZUS32405
3
5
0.60
ZUS32412
3
12
0.25
ZUS32415
3
15
0.20
ZUS34805
3
5
0.60
ZUS34812
3
12
0.25
ZUS34815
3
15
0.20
ZUS32415 ZUS34805 ZUS34812
DC36 - 72
0.167typ 0.088typ 0.082typ
75typ
71typ
76typ
15
5
12
0.20
0.60
0.25
60max 20max 48max
120max 40max 100max
120max 80max 120max
150max 120max 150max
180max 50max 150max
60max 20max 48max
ZUS34815
SPECIFICATIONS
ZU/ZT
MODEL
VOLTAGE[V]
*1
CURRENT[A]
INPUT
*1
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*2
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p] *2
TEMPERATURE REGULATION[mV] -20 to +55C
*3
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
PROTECTION
OVERCURRENT PROTECTION
CIRCUIT
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY
AGENCY APPROVALS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*
ZUS30505 ZUS30512 ZUS30515 ZUS31205 ZUS31212
DC4.5 - 9
DC9 - 18
0.896typ 0.857typ 0.857typ 0.357typ 0.338typ
67typ
70typ
70typ
70typ
74typ
5
12
15
5
12
0.60
0.25
0.20
0.60
0.25
20max 48max 60max 20max 48max
40max 100max 120max 40max 100max
80max 120max 120max 80max 120max
120max 150max 150max 120max 150max
50max 150max 180max 50max 150max
20max 48max 60max 20max 48max
20max (Minimum input, Io=100%)
ZUS31215 ZUS32405 ZUS32412
DC18 - 36
0.338typ 0.176typ 0.167typ
74typ
71typ
75typ
15
5
12
0.20
0.60
0.25
60max 20max 48max
120max 40max 100max
120max 80max 120max
150max 120max 150max
180max 50max 150max
60max 20max 48max
Fixed
4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75
Works over 105% of rating and recovers automatically
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
-20 to +71C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s2 (50G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, CSA C22.2 No.60950-1 Complies with IEC60950-1
35X7X23mm (WXHXD) / 16g max
Convection
Rated input. 5V, 12V, 24V or 48V DC, Io=100%
Measured by 20MHz oscilloscope.
The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output.
Series/Parallel operation with other model is not possible.
G-94
0.082typ
76typ
15
0.20
60max
120max
120max
150max
180max
60max
ZUS3
External view
¶Recomended size for
processing PCB
(TOP VIEW)
[0.9]
[0.6]
15.24
22.86
2-B part
¶Specification
at A part
16.51
(2.895)
29.21
4-º1
±0.1
2.5
1±0.1
0.4
2.5
2.7
(9.245)
¶Specification
at B part
0.4
4 7 ±0.3
2-A part
2-º1.6
[0.3]
-V
7.62
OUT
IN
(3.81)
-V
23
+V
7.62 7.62
+V
Size between
case pins
Name plate
Outline (1.25) (1.25)
22.86
(0.5)
35
6.35
(1.25)
16.51
[0.25]
[0.65]
(1.25) 4-º1.5
29.21
[1.15]
¶Weight: 16g or less.
¶Tolerance: ± 0.5
¶Case material: Brass
The converter is in contact with the
slanted area of the P.C.B. To keep
mm
isolation, adequate wiring on the ¶Dimensions in
mounted side is required.
¶Div.: 0.1inch [inch]
Performance data
¡STATIC CHARACTERISTICS (ZUS32405)
¡RISE TIME & FALL TIME (ZUS32405)
ZU/ZT
¡OVERCURRENT CHARACTERISTICS (ZUS32405)
¡DERATING CURVE
G-95