MICROSEMI 469-03

469-01, 469-02, and 469-03
SINGLE PHASE 10 AMP
RECTIFIER BRIDGES
SCOTTSDALE DIVISION
APPEARANCE
This series of high-current single-phase bridge rectifiers are constructed with
hermetically sealed rectifiers with the same design and construction as used in
military applications for the utmost in reliability. They can also be optionally obtained
with formal military screened diodes that have been subjected to 100% screening and
military qualified to MIL-PRF-19500/469 that are ideal for high-reliability applications
where a failure cannot be tolerated. These industry-recognized 10 Amp rated rectifier
bridges with working peak reverse voltages from 200 to 600 volts for each leg use
diodes that are hermetically sealed with voidless-glass construction using an internal
“Category I” metallurgical bond. Microsemi also offers numerous other rectifier
products to meet higher and lower current ratings with various recovery time speed
requirements including fast and ultrafast device types in both through-hole and
surface mount packages.
WWW . Microsemi .C OM
DESCRIPTION
IMPORTANT: For the most current data, consult MICROSEMI’s website: http://www.microsemi.com
FEATURES
•
•
•
•
•
•
APPLICATIONS / BENEFITS
•
•
•
•
•
•
•
Voidless hermetically sealed glass packages used
internally for each leg
Triple-layer passivation
Internal “Category I” Metallurgical bonds
JANTX and JANTXV available per MIL-PRF-19500/469
Controlled Avalanche Characteristics
Surge ratings of 100 Amps
MicroNote 050
MAXIMUM RATINGS
•
•
•
•
•
o
Conversion of single phase ac to dc current flow
Working Peak Reverse Voltages 200 to 600 V
Military and other high-reliability applications
High forward surge current capability
Low thermal resistance
Extremely robust construction
Inherently radiation hard as described in Microsemi
MECHANICAL AND PACKAGING
o
•
Junction Temperature: -65 C to +150 C
Storage Temperature: -65oC to +150oC
Maximum Avg Output Current: 10 Amps @ TC = 55°C
and 6 Amps @ TC = 100°C. Derate @ 88 mA / oC
between 55°C and 100°C. Derate @ 120 mA/ oC
above 100°C.
Non-repetitive Forward Surge Current (8.3 ms half
sine): 100 Amps @ TC = 55°C
o
Solder temperatures (terminals): 260 C for 10 s
(maximum)
•
•
•
•
•
CASE: Epoxy filled case with hermetically sealed
void-less hard glass rectifiers with Tungsten slugs
TERMINALS: Nickel plated brass with optional hot
Tin-Lead solder dip
MARKING: Part number on one side of case
POLARITY: Marked on body adjacent to terminals
(see terminal polarity marking on last page and
flattened corner on case for pin 1)
WEIGHT: 7.7 grams
See package dimensions on last page
ELECTRICAL CHARACTERISTICS
TYPE
WORKING
PEAK
REVERSE
VOLTAGE
VRWM
VOLTS
240
460
660
VOLTS
469-01
469-02
469-03
NOTE 1:
NOTE 2:
NOTE 3:
NOTE 4:
200
400
600
AVERAGE
RECTIFIED
CURRENT
IO1 @
MAXIMUM REVERSE
CURRENT PER LEG
IR @ VRWM
Note 1
AVERAGE
RECTIFIED
CURRENT
IO2 @
o
TC=+100 C
Note 2
TC = 25°C
AMPS
10
10
10
AMPS
6
6
6
μA
2
2
2
TC=+55oC
REVERSE
RECOVERY
trr
Note 3
TC = 100°C
FORWARD
VOLTAGE
VF @ 15.7 A
(pk) @ 8.3 ms
Duty Cycle
≤ 2%
μA
125
125
125
Volts
1.35
1.35
1.35
μs
2.5
2.5
2.5
Rated at TC = 55ºC with reference to metal case. Derate linearly at 88 mA/ºC between TC = 55ºC and TC = 100ºC
Derate linearly at 120 mA/ºC above TC = 100ºC.
IF = 0.5 A, IRM = 1.0 A, IR(REC) = .250 A
Point at which TC is referenced shall be in metal part of case as shown in drawing on last page.
Copyright © 2009
11-05-09 Rev B; 469-1.pdf
Microsemi
Scottsdale Division
8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503
Page 1
469-01, 469-02, 469-03
MINIMUM
BREAKDOWN
VOLTAGE
Per Leg
VBR
@50μA
469-01, 469-02, and 469-03
SINGLE PHASE 10 AMP
RECTIFIER BRIDGES
SCOTTSDALE DIVISION
Symbol
VBR
VRWM
IO
VF
IR
trr
Minimum Breakdown Voltage: The minimum voltage the device will exhibit at a specified current.
Working Peak Reverse Voltage: The maximum peak voltage that can be applied over the operating
temperature range excluding all transient voltages (ref JESD282-B). Also sometimes known as PIV.
Average Rectified Output Current: The Output Current averaged over a full cycle with a 50 Hz or 60 Hz sinewave input and a 180 degree conduction angle.
Maximum Forward Voltage: The maximum forward voltage the device will exhibit at a specified current.
Maximum Reverse Current: The maximum reverse (leakage) current that will flow at the specified voltage and
temperature.
Reverse Recovery Time: The time interval between the instant the current passes through zero when
changing from the forward direction to the reverse direction and a specified decay point after a peak reverse
current occurs.
WWW . Microsemi .C OM
SYMBOLS & DEFINITIONS
Definition
GRAPHS
469-01, 469-02, 469-03
FIGURE 1
Copyright © 2009
11-05-09 Rev B; 469-1.pdf
Microsemi
Scottsdale Division
8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503
Page 2
469-01, 469-02, and 469-03
SINGLE PHASE 10 AMP
RECTIFIER BRIDGES
SCOTTSDALE DIVISION
WWW . Microsemi .C OM
PACKAGE DIMENSIONS
469-01, 469-02, 469-03
Copyright © 2009
11-05-09 Rev B; 469-1.pdf
Microsemi
Scottsdale Division
8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503