HAMLIN 55100-AP-03-D

www.hamlin.com
55100 Miniature Flange Mount Hall Effect Proximity Sensor
Features
Benefits
Applications
● Magnetically operated position sensor
● Digital, latching or programmable analogue
types available
● Medium, high or programmable sensitivities
● 3 wire (voltage output) or 2 wire (current
output) versions
● Reverse/Over voltage protection
● Built in temperature compensation
●
●
●
●
High switching speed up to 10kHz
Long life; up to 20 billion operations
Unaffected by harsh environments
Operates in static or dynamic magnetic
field
● Customer selection of cable length and
connector type
●
●
●
●
●
●
DIMENSIONS (in) mm
Position and limit sensing
RPM measurement
Flow metering
Commutaion of brushless dc motors
Angle sensing
Magnetic encoders
BLOCK DIAGRAM
Notes:
1) Add capcitor Cn as
shown, close to the
sensor, for transient
suppression if required.
2) Add resistor Rpu as
shown for sinking output
SPECIFICATIONS
Hall Type
Supply Voltage (Note 1)
A - Analogue
2 Wire (Current Output)
(Programmable Only) (Note 2)
Vdc
-15 to +28
-15 to +28
8.5
Operate
Vdc
+3.8 to +24
+3.75 to +24
4.5 - 5.5
Overvoltage Protection
Vdc - max.
32
32
19.5
Sinking output
N/A
4.65
Vdc - max.
0.4 @ 10mA
N/A
0.35
mA - max.
10
N/A
-1.0 to +1.0
1.6 - 5.2
1.6 - 5.2
5 - 6.9
12 - 17
2 - 10
2 - 10
Vdc
Output Low Voltage
Output Current (continuously on)
Low
High
mA
mA
Switching Speed
Temperature
Digital Switch or Digital Latch
3 Wire (Voltage Output)
Absolute Ratings
Output High Voltage
Current Consumption Over
Temperature Range
Digital Switch or Digital Latch
Operating
Storage
mA
10
10
2
°C
°C
-40 to +100
-65 to +105
-40 to +100
-65 to +105
-40 to +100
-65 to +105
Note 1: As long as Tj (Junction Temperature max. Is not exceeded.
Note 2: Preprogrammed by Hamlin or Customer pending agreement.
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 1
TABLE 3
TABLE 2
HALL OPTIONS
Cable Length:-
Termination Options:-
ACTIVATE DISTANCES ARE APPROXIMATE
(Cable Type 24AWG 7/32 PVC 105° C
UL 1430/UL1569)
SELECT OPTION
USING NEFEB MAGNET
(.827l x .276W x .185H) 21 x 7 x 4.7
HAMLIN P/N 5812334000
Select Hall Option
Hall Type
Sensitivity Gauss
(typ.)
Activate - d (in)
mm
2M
2 Wire Switch
120
(.531) 13,5
2H
2 Wire Switch
57
(.728) 18,5
2L
2 Wire Latch
40
3M
3 Wire Switch
130
3H
3 Wire Switch
3L
3 Wire Latch
AP
Analog
SELECT
OPTION
CABLE
LENGTH
(in) mm
01
(3.94) 100
02
(11.81) 300
(.827) 21,0
03
(19.69) 500
(.492) 12,5
04
(29.53) 750
59
(709) 18,0
05
86
(.394) 10,0
(39.37)
1000
Programmable
Consult Hamlin
ORDERING INFORMATION
55100
XX
XX
Series 55100
Hall Option
Table 1
Cable Length
Table 2
Table 3
Termination
Hamlin USA
Hamlin Europe
Hamlin China
DESCRIPTION (2 WIRE VERSION ILLUSTRATED
Standard Lengths
Tel: +1 920 648 3000 • Fax: +1 920 648 3001 • Email: [email protected]
Tel: +44 (0)1603 257700 • Fax: +44 (0)1603 257702 • Email: [email protected]
Tel: +86 (0) 512 69365 800 • Fax: +86 (0) 512 69365 811 • Email: [email protected]
DRGNo: 55100XXXXX REV : AG Date:9/6/12 DCR: B9016
X
A
Tinned Leads
D
AMP MTE 2.54mm pitch
E
JST XHP 2.5mm pitch