ETC 6753-OF

a Pressure & Vacuum Switches
SWITCHING
AND
SENSING
SOLUTIONS
Herga Electric Limited is an independent UK manufacturer of
switching systems. In addition to pressure and vacuum switches, we offer
other innovative switching solutions:hergair
herga
hergalite
herga
Airswitching systems
Footswitches
Fibre Optics / Infra red safety products
Hand controls
Our expertise spans the automotive, medical, packaging,
domestic appliance and spa industries.
Herga is driven to respond rapidly to delight our customers. Herga seeks
to develop its relations with customers to achieve their business goals.
Global Presence
Our distributor network covering the worlds major markets enables
technical help and assistance to be just a phone call away.
Continuous Improvement
Herga’s approval to ISO 9002 ensures that we are fully in control of our quality.
However, this is just the starting point for an aspiring World Class company.
We encourage training and development and continuous improvements
at individual, team and company level.
How can we help you?
This brochure provides a brief overview of our product range. If you
require further information, please contact us at our e-mail address:
[email protected]
Herga’s customers worldwide include
BMW/Rover
Electrolux
Jacuzzi
RS Components
Siemens
General Electric
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
Pressure & Vacuum Switches
6702 High Pressure Switch
High pressure switch all plastic construction. Ranges 1.4-13.8 Bar (20-200 PSI).
Two (2) Pole Electrical Switching.
Page PV1 & 2
6773 Double Diaphragm Pressure Switch
Double diaphragm construction to meet double insulation requirements of
EN 60335-2-60. Water presence detection.
Page PV3
6761 and 6763 Low Air Pressure Vacuum Switches
Printed circuit board mounted, pressure/vacuum switches. UL versions available.
Range from (0.015 Bar - 1.0 Bar Pressure) (-0.015 Bar - 0.670 Bar Vacuum).
Page PV4
6741 and 6742 Medium Pressure Switches
Constructed in Nylon 12 material (pressure range 0.1 Bar to 8.2 Bar).
Single or double pole in 8 adjustable switch ranges. UL versions available.
Page PV5 & 6
6731 and 6732 Low Pressure Switches
Constructed in Nylon 12 material (pressure range (0.0037 Bar to 0.137 Bar).
Single or double pole in 3 adjustable switch ranges. UL versions available.
Page PV7 & 8
6753 Low Air Pressure/Vacuum Switches
Small versatile compact differential switch with low contact inertia for rapid switching
(range 2.5 mbar to 40 mbar).
Page PV9 & 10
6721 and 6722 Vacuum Switches
Constructed in Nylon 12 material (vacuum range -0.0075 Bar to -0.670 Bar).
Single or double pole in 5 adjustable switch ranges. UL versions available.
Page PV11 & 12
Pressure Conversion Chart
For more commonly used measurements, including flow, liquid, force and weight
equivalents.
Page PV13
Certification Markings
Page PV14
Covers most worldwide authorities/certification marks.
Accessories / Switch Housings
Air and electrical connections are available for all pressure and vacuum switches. Please
also refer to Airswitching section or contact herga for details.
Page PV15
Fax Back Sheet
Page PV16
For your fast quotation service.
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6702 ~ High Pressure Switch
Benefits
❖ High pressure switch, all plastic construction (glass
loaded nylon)
❖ Alternate diaphragm and connectors available for
volume orders
6702
❖
❖
❖
❖
Excellent repeatability
Switches have adjustable pressure and differential
Specific settings can be set for volume orders
IP65 enclosures class II double insulated
0
0
0
0
1. Model Number
2. Operating Pressure
A 20 - 50 PSI (1.40 - 3.45 Bar) Red Spring
B 40 - 100 PSI (2.76 - 6.89 Bar) White Spring
C 80 - 200 PSI (5.52 - 13.79 Bar) Blue Spring
3. Additional Operating (Springs)
A 20 - 50 PSI (1.40 - 3.45 Bar)
B 40 - 100 PSI (2.76 - 6.89 Bar)
C 80 - 200 PSI (5.52 - 13.79 Bar)
D 20 - 50 PSI (1.40 - 3.45 Bar) & 40 - 100 PSI
E 40 - 100 PSI (2.76 - 6.89 Bar) & 80 - 200 PSI
F 80 - 200 PSI (5.52 - 13.79 Bar) & 20 - 50 PSI
G 20 - 50 PSI (1.40 - 3.45 Bar) & 40 - 100 PSI
& 80 - 200 PSI (5.52 - 13.79 Bar)
Z No additional springs supplied
(2.76 - 6.89 Bar)
(5.52 - 13.79 Bar)
(1.40 - 3.45 Bar)
(2.76 - 6.89 Bar)
4. Electrical Microswitching Rating
A 21A 250V ac Silver Change Over Contacts
B 0.1A 250V ac Gold Change Over Contacts
C 0.1A 24V ac/dc Gold Change Over Contacts
5. Packaging and Label Option
A Herga individually packed in plain carton
B Herga vacuum form tray (for quantities 10+)
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6702 ~ High Pressure Switch
6702 Pressure Switch
The industrial pressure switch is moulded entirely in plastic with the
exception of the pressure connection and is water, oil and dust proof to
IP65. The switches have excellent repeat accuracy, even over widely
varying ambient conditions.
The operating pressure is adjustable externally using the thumb screw on
the top and the approximate pressure setting can be seen through a window
in the cover. To discourage unauthorised tampering, the adjusting screw can
be locked in position with an M1.5mm Allen screw.
The microswitches have independent vernier adjustment and are normally
set to operate within 2 PSI on rising pressure. Where two pressure levels
are to be controlled, the switches can be adjusted separately so that one
switch will operate at up to 80% of the level of the second. The switches can
also be set to operate simultaneously on falling pressure instead of rising
pressure.
The pressure switch is of Class II construction with double insulation.
For quantity orders, many special options are available, please enquire:❖ Single or double pole switching set to specific pressure levels
❖ Alternative connector sizes
❖ Alternative diaphragms and metal chambers to resist particular fluids
❖ Installation and setting instructions are supplied with each product
Note: differentials are approximate
Suitability for use with different operating media
Pressure Medium
Other Information
Withstand pressure
500 PSI (34.5 Bar)
Setting accuracy when set by herga
± 10%
Temperature range
-5˚C to +70˚C
Diaphragm
Fabric reinforced Nitrile
Weight
300g
Silver Contact Microswitch Data
Average Life
Expectancy
Mechanical
1.0 x 106
Electrical
2.0 x 105 @ 10A 1.0 x 104 @ 21A
Max. Electrical Load
Electrical Rating
AC
Voltage
Res.
250V
21A
250V
21A
125V
21A
6V
21A
21A
12V
15A
15A
24V
8A
7A
60V
1A
0.5A
110V
0.5A
0.2A
220V
0.25A
0.1A
DC
Ind.
(Pf 0.75 Motor)
1HP
8A
2HP
Gold Contact Microswitch Data
Average Life
Expectancy
Mechanical
Electrical
1.0 x 1.06
2.0 x 105 @ 10A 1.0 x 104 @ 21A
Electrical Rating
Max. Electrical Load
✓ = Recommended
Voltage
Res.
Ind.
(Pf 0.75 Motor)
AC
250V
0.1A
0.05
N/A
UL/CSA Only
125V
0.1A
-----
-----
Switch Standards:
EN 60730, EN 61058 and UL 508
Approvals Available:
CE, BEAB, CSA, DEMCO, IMQ, KEMA, NEMCO,
OVE, SEMCO, SET I, SEV, UL, VDE
1999
6702
Acetone
Ammonia (Liquid)
Amyl Alcohol to 20˚C
Automotive Brake Fluid
Beer
Butane
Carbon Dioxide (Dry)
Citric Acid
Copper Sulphate (Sol.)
Compressed Air
Cutting Oil
Diesel Oil
Detergent Solution
Fuel Oil
Glycol
Hydraulic Oil
Hydrogen
Lubricating Oil
Milk
Mineral Oil
Natural Gas
Oxygen to 70˚C
Petrol
Plating Solution (Chrome)
Salt Water
Sewage
Turpentine
Vinegar
Water
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
= Suitable with modifications
Note: Dry Switching - if switching low power circuits, low current (4 to
100 milliamperes) and low voltage (below 30V), consult herga or refer
to gold contact in section 4 of the opposite page.
Herga do not accept liability for any pressure operated device used
outside the pressure range specified by the company.
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6773 ~ Double Diaphragm Pressure Switch
Benefits
❖ Specified to EN 60335-2-60 double insulated for water
detection
❖ Gold contacts available
❖ Various microswitch options
❖ Multiple cap and spout options available
6773
❖ Other pressures available up to 10 PSI
A
A
1. Model Number
2. Pressure Range
A 250mm H2O to 760mm H2O Standard
3. Caps
A Side Entry Std Spout Std Orientation 4.0mm Spout
B Side Entry Std Spout Rotated 90˚ Viewed From Cap 4.0mmØ Spout
C Side Entry Std Spout Rotated 180˚ Viewed From Cap 4.0mmØ Spout
D Side Entry Std Spout Rotated 270˚ Viewed From Cap 4.0mmØ Spout
E Side Entry Long Spout 4.0mmØ Std Orientation
F Side Entry Long Spout Rotated 90˚ Viewed From Cap 4.0mmØ Spout
G Side Entry Long Spout Rotated 180˚ Viewed From Cap 4.0mmØ Spout
H Back Entry Short Thread 4.0mmØ Spout. Not suitable for ‘O’ ring
J Back Entry Long Thread 4.0mmØ Spout
K Back Entry Long Thread 2.0mmØ Spout
L Long Thread Spout Rotated @ 90˚ 4.0mmØ Spout
4. Bleed
A No Bleed Cap
J With Bleed Cap
5. Nut Specification
A Black Moulded Nut
B Black Moulded Nut and ‘O’ Ring (only available with options 3J,
K & L above)
6. Authority
A European Tag Configuration
7. Terminal Combinations
A 3 Blade QC 6.3mm x 0.8mm
B 2 Blade QC 6.3mm x 0.8mm Normally Open Contacts
C 2 Blade QC 6.3mm x 0.9mm 90˚ Crank Normally Open Contacts
8. Microswitch Rating
A 0.1A 125/250V ac Gold Contacts (not available with option 7c)
B 10A 1/4 HP 125/250V ac
C 21A 250V ac 1 HP 125V ac 2 HP 250V ac
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6761 & 6763 ~ Low Air Pressure Vacuum
Switches (slow make contacts)
Benefits
❖
❖
❖
❖
❖ A range of small switches designed for direct
mounting onto printed circuit boards
❖ UL versions available
❖ Various spout orientations available
❖ Double diaphragm versions available upon request
Available with base or side tube entry
Silver or gold contact options
Switches can be factory set within specified tolerances
'O' ring seals available for dust and water tight
applications, back entry versions only
Printed Circuit Board Mounting Switches
Model No
Pressure/Vacuum range
6761 (Vacuum)
6763 (Pressure)
Minimum
150mm (6 ins) Wg
150mm (6 ins) Wg
Maximum
670 millibar (9.8) PSI
1.0 Bar (14.7) PSI
Approximately 0.06 ins WG
Approximately 0.06 ins WG
Maximum Differential
Pressure/Vacuum Range
Adjustable variants
Adjustable variants
Body Withstand Pressure
2.7 Bar (40) PSI
2.7 Bar (40) PSI
Air Bleed Version
Available upon request
Available upon request
Flow Rate Litre / Min (with air bleed)
8 - 30cc/Min @ 31 ins WG
8 - 30cc/Min @ 31 ins WG
Pressure Connection
4mm Ø spout for side and back entry
4mm Ø spout for side and back entry
2mm Ø spout for back entry only
2mm Ø spout for back entry only
Lower spout ‘V’ vacuum
Upper spout ‘P’ pressure
4mm spout = 2311-01 or 2311-08
4mm spout = 2311-01 or 2311-08
2mm spout = 2311-03
2mm spout = 2311-03
-10˚C to 85˚C (Flow Solder 220˚C for 5 Sec)
-10˚C to 85˚C (Flow Solder 220˚C for 5 Sec)
Switch
Single Pole Normally Open
Single Pole Normally Open
Contact Rating Maximum
0.5A RES 250V ac (Silver contacts)
0.5A RES 250V ac (Silver Contacts)
50mA RES 250V ac
50mA RES 250V ac
Connecting Tube Reference
Temperature Range
Electrical Data
UL
(Maximum ratings may not be achieved at low pressure settings)
Dry Switching Maximum Recommended Current
10mA 24V dc (UL)
10mA 24V dc (UL)
Body
Glass filled polyester
Glass filled polyester
Diaphragm
Silicone as standard
Silicone as standard
Contacts
Silver or gold plated copper pins
Silver or gold plated copper pins
Mechanical Life
1 x 10 cycles
1 x 106 cycles
Weight (grams)
8grms
8grms
6
6761/6763 Vacuum and Pressure Switch Range
A miniature, compact low pressure switch designed for direct fitting
by solder pins to printed circuit boards. Both vacuum and pressure
ports are provided making the unit ideal for differential switching.
Typical applications are indicators, emergency cut-out and alarms,
filter and low pressure/vacuum monitoring. The switch is made to
order for specific applications, the actual operating pressures or
vacuum being set during production. However, final adjustment may
be made after installation by the slotted screw in the base. The body
construction allows the two ports to be set at any angle to each other.
1999
Non Std
shown as 270˚
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6741 / 6742 ~ Medium Pressure Switches
Benefits
❖ Switches set to specific rising or falling pressures
❖ Single or double pole switching
❖ UL recognised versions available
❖ Customised settings available upon request
❖ High performance repeatability
❖ Various connector options available
Silver Contact Microswitch Data
Average Life
Expectancy
1.0 x 106
Mechanical
5
Electrical
2.0 x 10 @ 10A 1.0 x 10 @ 21A
Electrical Rating
AC
Model No
4
Max. Electrical Load
Voltage
Res.
250V
21A
250V
21A
125V
21A
Ind.
1HP
8A
6V
21A
21A
12V
15A
15A
24V
8A
7A
60V
1A
0.5A
110V
0.5A
220V
0.25A
DC
(Pf 0.75 Motor)
1HP
6742-20/30/40/50/60
6742-70/80/90
Electrical Switch Data 2 Pole change over
2 Pole Change over
Contact Rating
21 (8) A 250V ac
21 (8) A 250V ac
1/8"
1/8"
Pressure Connection
Brass
Setting Accuracy
± 10% as standard
± 10% as standard
Withstand Pressure
25 PSI or x 2
150 PSI 10 Bar
Temperature Range
-5˚C to + 70˚C
-5˚C to + 70˚C
Body Material
Nylon 12
BSPT
Brass
BSPT
Nylon 12
Nitrile fabric
reinforced fitted in
brass pressure
capsule
Diaphragm
Neoprene
0.1A
Spring
Spring steel
Spring steel
0.1A
Weight
50gm
85gm
Gold Contact Microswitch Data
Average Life
Expectancy
1.0 x 106
Mechanical
Electrical
6
2.0 x 10 @ 10A 1.0 x 104 @ 21A
Electrical Rating
Max. Electrical Load
Pressure Range
P.S.I
Bar
Differential
(Fixed)
6742-20
1.5 - 3.5
0.10 - 0.24
See chart 1
Model No
Voltage
Res.
Ind.
(Pf 0.75 Motor)
6742-30
3.0 - 5.5
0.20 - 0.37
See chart 1
AC
250V
0.1A
0.05
N/A
6742-40
5 - 10
0.34 - 0.68
See chart 1
UL/CSA Only
125V
0.1A
-----
-----
6742-50
8 - 18
0.54 - 1.22
See chart 2
6742-60
16 - 30
1.08 - 2.04
See chart 2
EN 60730, EN 61058 and UL 508
6742-70
25 - 55
1.70 - 3.79
See chart 3
CE, BEAB, CSA, DEMCO, IMQ, KEMA, NEMCO,
OVE, SEMCO, SET I, SEV, UL, VDE
6742-80
45 - 75
3.1 - 5.17
See chart 3
6742-90
60 - 120
4.14 - 8.27
See chart 3
Switch Standards:
Approvals Available:
NB
Herga do not accept liability for any pressure operated device used
outside the pressure range specified by the company.
1999
Special options are available for quantity orders
❖ Diaphragms in silicon rubber, nitrile, EPDM
❖ Switches with wide or close differentials
❖ Springs in stainless steel
❖ NPT connectors available
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6741 / 6742 ~ Medium Pressure Switches
Suitability for use with different operating media
Key:
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
8
0.5
6
0.4
✓
✓
✓
✓
✓
✓
✓
✓
✓
2
6472-20
0.1
0
0
2
0
Bar
2.0
4
0.1
0.2
0.3
25
✓
✓
✓
1.0
15
✓
✓
✓
✓
✓
0.7
Bar
30
PSI
6472-60
in
20
✓
✓
0.6
M
✓
✓
1.5
xD
✓
0.5
PSI
30
Ma
✓
✓
0.4
10
Chart 2
RISING PRESSURE
✓
8
PSI
✓
✓
6
al
✓
✓
0.2
nti
✓
✓
6472-30
re
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
4
6472-40
iffe
✓
0.3
6472-50
10
0.5
✓ = Recommended
✓
M
ax
✓
M
in
✓
0.6
ial
✓
nt
✓
re
Acetone
Ammonia (Liquid)
Amyl Alcohol to 20˚C
Automotive Brake Fluid
Beer
Benzyl Alcohol
Butane
Carbon Dioxide - Dry
Citric Acid
Copper Sulphate (Sol.)
Compressed Air
Cutting Oil
Diesel Oil
Detergent Solution
Fuel Oil
Glycol
Hydraulic Oil
Hydrogen
Lubricating Oil
Milk
Mineral Oil
Natural Gas
Nitric Acid (Dil.)
Oxygen to 70˚C
Petrol
Plating Solution (Chrome)
Salt Water
Sewage
Sulphur Dioxide
Turpentine
Vinegar
Water
6742/70/80
& 90
ffe
Chemical Compatibility
10
Di
Diaphragms
6742/20/30/40
50 & 60
Chart 1
PSI
RISING PRESSURE
Pressure Medium
0.7
D
iff
er
en
D
iff
tia
er
l
en
tia
l
Bar
5
FALLING PRESSURE
5
= Suitable with modification
= Not suitable
10
15
0.5
20
25
1.0
1.5
2.0
Bar
Chart 3
Bar
PSI
8
120
80
5
Alternative Pressure Connections
1/8” NPT Pressure Connector
4
70
60
nt
ia
Di
ffe
ax
90
6472-90
M
in
M
RISING PRESSURE
6
re
Di
ffe
100
l
re
n
tia
l
110
7
6472-80
50
3
40
6472-70
30
FALLING PRESSURE
20
20
30
2
40
50
3
60
4
70
80
5
90
6
100 110
7
120
8
PSI
Bar
Note: Differentials are approximate
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6731 / 6732 ~ Low Pressure Switches
Benefits
❖ These switches have been designed primarily for the
OEM manufacturer who requires low cost and high
reliability
❖ The switches have excellent repeat accuracy
❖ Double pole switching available upon request
❖ Wide choice of microswitch options including tab
configurations
❖ UL recognised versions available
Model No
6731-03
Single Pole
Electrical Switch
change over
6731-06
Single Pole
change over
6731-10
Single Pole
change over
Contact Rating
10(3)A 250V ac
21(8)A 250V ac
Pressure
Connection
3(1)A 250V ac
Inches Water
Side entry spout Side entry spout Side entry spout
4mm O/D
4mm O/D
4mm O/D
Setting Accuracy ± 10% as std
Pressure Range
Model No
6731-03
1.5 - 7
40 - 180
See chart 1
6731-06
5 - 25
127 - 635
See chart 1
6731-10
20 - 55
510 - 1400
See chart 1
± 10% as std
± 10% as std
25 PSI
25 PSI
25 PSI
Nylon 12
Nylon 12
Nylon 12
Diaphragm
Neoprene
Neoprene
Neoprene
❖ Diaphragms in silicon rubber, nitrile, EPDM
Spring
Spring steel
Spring steel
Spring steel
❖ Switches with wide or close differentials
Weight
50gm
50gm
50gm
❖ Springs in stainless steel
Withstand
Pressure
Body Material
Pressure Switches
Average Life
Expectancy
Differential
(Fixed)
mm Water
Special options are available for quantity orders
❖ Switches set to specific operating pressure, rising or falling
6731-03
6731-06
6731-10
Mechanical
2 x 106
2 x 106
1.0 x 106
Electrical
0.2 x 106 @ 1A
Electrical Rating
0.2 x 106 @ 6A
Max Electrical Load
50K @ 10A
0.2 x 106 @ 10A
Max Electrical Load
10K @ 21A
Max Electrical Load
Resistive
Inductive
Resistive
Inductive
Motor (Pf0.75)
Resistive
Inductive
Motor (Pf0.75)
125V
3A
1A
10A
10A
0.5HP
21A
15A
1HP
AC
250V
3A
1A
10A
10A
0.5HP
21A
15A
2HP
DC
6V
3A
1A
10A
10A
21A
21A
12V
3A
1A
5A
3A
15A
15A
24V
1A
0.5A
5A
3A
8A
7A
60V
1A
0.5A
1A
0.5A
1A
0.5A
110V
0.5A
0.2A
0.5A
0.2A
0.5A
0.2A
220V
0.25
0.1A
0.25A
0.1A
0.25A
0.1A
Voltage
Switch Standards:
EN 60730, EN 61058 and UL 508
Approvals Available
CE, BEAB, CSA, DEMCO, IMQ, KEMA, NEMCO, OVE, SEMCO, SET I, SEV, UL, VDE. Approved to BS 3955 part III
Note: Dry Switching
If switching low power circuits, low current (4 to 100 milliamperes) and low voltage (below 30V), consult herga for special switches.
NB - Herga do not accept liability for any pressure operated device used outside the pressure range specified by the company.
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6731 / 6732 ~ Low Pressure Switches
Suitability for use with different operating media
Pressure Medium
Diaphragms
6731
Chemical Compatibility
✓
Acetone
Ammonia (Liquid)
Amyl Alcohol to 20˚C
Automotive Brake Fluid
Beer
Benzyl Alcohol
Butane
Carbon Dioxide - Dry
Citric Acid
Copper Sulphate (Sol.)
Compressed Air
Cutting Oil
Diesel Oil
Detergent Solution
Fuel Oil
Glycol
Hydraulic Oil
Hydrogen
Lubricating Oil
Milk
Mineral Oil
Natural Gas
Nitric Acid (Dil.)
Oxygen to 70˚C
Petrol
Plating Solution (Chrome)
Salt Water
Sewage
Sulphur Dioxide
Turpentine
Vinegar
Water
Key:
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ = Recommended
✓
= Suitable with modification
= Not suitable
Chart 1
mm Wg
in WG
60
1400
50
800
30
600
20
iff
er
iff
er
D
D
in
ax
M
M
40
RISING PRESSURE
1000
en
en
tia
l
tia
l
1200
6731-10
6731-06
400
10
200
6731-03
0
0
0
0
10
200
FALLING PRESSURE
20
400
30
600
800
40
1000
50
1200
60
1400
in WG
mm Wg
Note: Differentials are approximate
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6753 ~ Low Air Pressure / Vacuum Switches
Benefits
❖ Sensitive versatile switch - ideal for long tube length
applications
❖ Normally open or normally closed contact configuration
❖ Ideal for switching low power circuits
❖ Bleed versions available for temperature compensation
❖ Easily adjustable settings
❖ Custom pressure, vacuum and bleed settings available
upon request
6753
0
0
0
1. Model Number
2. Operation
A Normally Open - Pressure
B Normally Closed - Vacuum
3. Bleed Adjuster Options
A Bleed A side only, Vacuum N/O to N/C, Pressure N/C to N/O
B Bleed B side only, Vacuum N/O to N/C, Pressure N/C to N/O
C Bleed both sides Vacuum / Pressure
D No bleed variant either side Vacuum / Pressure
4. Bleed Setting
A 100 - 300 cc/Min Factory Setting
J No bleed setting
5. Pressure Setting
A 2.25" WG ± 0.5" Std
C
3" WG ± 0.5"
E
6" WG ± 10%
G 10" WG ± 10%
J 14" WG ± 10%
B 2" WG ± 0.5"
D 4" WG ± 0.5"
F 8" WG ± 10%
H 12" WG ± 10%
K 16" WG ± 0 - 10%
6. Packaging Options
A Vacuum Form Tray (100 off volumes - ideal for OEM applications)
B Poly Bag (individual)
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6753 ~ Low Air Pressure / Vacuum Switches
Technical Data
Electrical Data
Pressure/Vacuum range minimum 25mm (1 in) Wg
Switch
maximum 400mm (16 ins) Wg
Single pole, N/Open / N/Closed
0.5A RES 250V ac
(Maximum ratings may not be
achieved at low pressure
settings)
Maximum Differential
400mm (16 ins) Wg
Contact Rating Maximum
Pressure
Standard Factory Setting
50mm (2.25 ins) Wg
(Contacts Normally Open) Other
settings available see note 2)
Dry Switching Minimum Current
5mA 4V dc
Body
Glass filled nylon 12
Diaphragm
Neoprene
Contacts
Gold plated silver mounted on
phosphor-bronze blades
Maximum Differential Between
Pressure Connection
0.34 Bar (5 PSI)
Body Withstand Pressure
1.0 Bar (14.7 PSI)
Air Bleed Version
See choice options 3 & 4, other
settings available, see note 3)
Contact Resistance
0.05 Ohms
Mechanical Life
1 x 106 cycles
Flow Rate Litre / Min
Standard 100 - 300 cc/Min
@ 5 PSI
Weight (grams)
10grms
Connection Position
Base
Pressure Connection
4mm dia spouts
For reducing connectors, please
refer to accessories page
Connecting Tube Reference
2311-08 or 2311-01
Temperature Range
-5˚C to 50˚C
see note
2)
6753 Pressure Switch Range
For very sensitive pressure, vacuum and differential pressure switching.
The 6753 range of switches provide a high specification in a small, versatile body shell. Great care has been taken in the switch unit design, keeping
the moving mass and therefore inertia to a minimum. This means that it can operate at a high cycle rate with low pressure, vacuum or pressure
differential. This design feature can be used when measuring pressure pulses such as on component counting applications and used with herga Safe
Edges. The switch will operate very rapidly keeping the switch delay to a minimum.
1) For good repeatable switching, the contacts are gold plated on solid silver. The electrical rating of the switch is dependent on the contact pressure.
This pressure is dependent on the air pressure. Thus, for very sensitive setting the permissible switching current will be lower than normal.
2) The standard switch can be adjusted to give normally closed or normally open contacts depending on the application. For operation on pressure
with normally closed contacts, connect to air connection ‘A’ and screw in sensitivity adjusting screw ‘S’ until contacts are normally closed. For
operation on pressure with normally open contacts, connect to air connection ‘B’ and set with contacts normally open.
3) A separate version, (see bleed options), is provided with adjustable air bleeds on both sides of the diaphragm. These air bleeds are adjusted to
a level which is suitable for most applications involving safe edges or elbows, and prevent pressure or vacuum building up inside when the
ambient temperature or atmospheric pressure changes.
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6721 / 6722 ~ Vacuum Switches
Benefits
❖ These switches have been designed primarily for the
OEM manufacturer who requires low cost and high
reliability
❖ The switches have excellent repeat accuracy
❖ Double pole switching available upon request
❖ Wide choice of microswitch options available including
tab configurations
❖ UL recognised versions available
Model No
6721-03
Electrical Switch Single Pole
change over
Data
Contact Rating 3(1)A 250V ac
Vacuum
Connection
6721-06
Single Pole
change over
6721-20/30/40
Single Pole
change over
10(3)A 250V ac
21(8)A 250V ac
± 10% std
± 10% std
Temperature
Range
Body Material
-5˚C to + 70˚C
-5˚C to + 70˚C
-5˚C to + 70˚C
Nylon 12
Nylon 12
Nylon 12
Diaphragm
Neoprene
Spring (in
Vacuum Cavity)
Inches Water
Side entry spout Side entry spout Side entry spout
4mm O/D
4mm O/D
4mm O/D
Setting Accuracy ± 10% std
Spring steel
Neoprene
1)
Spring steel
Neoprene
1)
1)
Spring steel
Vacuum Range
Model No
mm Water
Differential
(Fixed)
6721-03
3-8
75 - 200
See chart 1
6721-06
7 - 15
180 - 380
See chart 1
6721-20
13 - 32
330 - 810
See chart 1
6721-30
28 - 80
710 - 2030
See chart 2
6721-40
75 - 270
1900 - 6860
See chart 2
Special options are available for quantity orders
❖ Switches set to specific operating vacuum, rising or falling
❖ Diaphragms in silicon rubber, nitrile, EPDM
❖ Switches with wide or close differentials
❖ Springs in stainless steel
Note: The spring is fitted in the vacuum cavity in contact with the media
Pressure Switches
Average Life
Expectancy
6731-03
6731-06
6731-10
Mechanical
2 x 10
2 x 10
1.0 x 106
Electrical
0.2 x 106 @ 1A
Electrical Rating
6
0.2 x 106 @ 6A
Max Electrical Load
Resistive
Voltage
AC
DC
Inductive
6
50K @ 10A
0.2 x 106 @ 10A
Max Electrical Load
Resistive
10K @ 21A
Max Electrical Load
Inductive
Motor (Pf0.75)
Resistive
Inductive
Motor (Pf0.75)
125V
3A
1A
10A
10A
0.5HP
21A
15A
1HP
250V
3A
1A
10A
10A
0.5HP
21A
15A
2HP
6V
3A
1A
10A
10A
21A
21A
12V
3A
1A
5A
3A
15A
15A
24V
1A
0.5A
5A
3A
8A
7A
60V
1A
0.5A
1A
0.5A
1A
0.5A
110V
0.5A
0.2A
0.5A
0.2A
0.5A
0.2A
0.25A
0.1A
0.25A
0.1A
0.25A
0.1A
220V
Switch Standards:
EN 60730, EN 61058 and UL 508
Approvals Available
CE, BEAB, CSA, DEMCO, IMQ, KEMA, NEMCO, OVE, SEMCO, SET I, SEV, UL, VDE. Approved to BS 3955 part III
Note: Dry Switching
If switching low power circuits, low current (4 to 100 milliamperes) and low voltage (below 30V), consult herga for special switches.
NB - Herga do not accept liability for any vacuum operated device used outside the pressure range specified by the company.
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
6721 / 6722 ~ Vacuum Switches
mm
Hg
Suitability for use with different operating media
Vacuum Medium
Diaphragms
-50
-30
-40
-25
6721
Chemical Compatibility
-20
-20
-15
-10
0
-5
0
-10
0
6721-03
5
✓
INCREASING VACUUM
✓
✓
D
iff
er
en
t
M
in
M
ax
✓
ia
l
D
iff
er
en
t
ia
l
6721-20
✓
✓
✓
10
-20
15
-30
20
-40
25
-50
30
In
WG
Chart 1
mm
Hg
-400 -350
-300 -250
-200 -150 -100
In
WG -225 -200 -175 -150 -125 -100 -75
-80
mm
Hg
-50
-25 -10
-25
-50
REDUCING VACUUM
-50
6721-30
✓
-100
-75
✓
✓
ax
Di
✓
M
✓
✓
INCREASING VACUUM
ia
ffe
in
re
nt
Di
6721-40
l
ffe
re
nt
ia
l
-150
M
✓
✓
-10
6721-06
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
0
REDUCING VACUUM
-100
-200
-125
-250
-150
-300
-175
-200
-225
✓
✓
-250
✓
✓ = Recommended
✓
-30
✓
Acetone
Ammonia (Liquid)
Amyl Alcohol to 20˚C
Automotive Brake Fluid
Beer
Benzyl Alcohol
Butane
Carbon Dioxide - Dry
Citric Acid
Copper Sulphate (Sol.)
Compressed Air
Cutting Oil
Diesel Oil
Detergent Solution
Fuel Oil
Glycol
Hydraulic Oil
Hydrogen
Lubricating Oil
Milk
Mineral Oil
Natural Gas
Nitric Acid (Dil.)
Oxygen to 70˚C
Petrol
Plating Solution (Chrome)
Salt Water
Sewage
Sulphur Dioxide
Turpentine
Vinegar
Water
Key:
In
WG
Chart 2
= Suitable with modification
= Not suitable
-350
-400
-450
-275 -500
mm
In
Hg
WG
Note: Differentials are approximate
Alternative Vacuum Connections
Back entry 1/8” BSPT and NPT Connectors
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
Pressure Conversion Table
P.S.I
in/H20
in/Hg mm/H20 mm/Hg kg/cm2
bar
mbar
Pa
kPa
P.S.I
in/H20
in/Hg mm/H20 mm/Hg kg/cm2
1.0
27.71
2.036
703.1
51.75
bar
mbar
Pa
kPa
.0703
.0689
68.95
6895
6.895
5.6
155.0
11.40
3937
289.6
.3937
.3861
386.1
38610
38.61
1.1
30.45
2.240
773.4
1.2
33.22
2.443
843.7
56.89
.0773
.0758
75.84
7584
7.584
5.7
157.8
11.60
4008
294.8
.4007
.3930
393.0
39300
39.30
62.06
.0844
.0827
82.74
8274
8.274
5.8
160.5
11.81
4078
299.9
.4078
.3999
399.9
39990
1.3
35.98
2.647
39.99
914.0
67.23
.0914
.0896
89.63
8963
8.963
5.9
163.3
12.01
4148
305.1
.4148
.4068
406.8
40680
1.4
38.75
40.68
2.850
984.3
72.40
.0984
.0965
96.52
9652
9.652
6.0
166.1
12.22
4218
310.3
.4218
.4137
413.7
41370
1.5
41.37
41.52
3.054
1055
77.57
.1055
.1034
103.4
10340
10.34
6.1
168.8
12.42
4289
315.5
.4289
.4206
420.6
42060
42.06
1.6
44.29
3.258
1125
82.74
.1125
1103
110.3
11030
11.03
6.2
171.6
12.62
4359
320.6
.4359
.4275
427.5
42750
42.75
1.7
47.06
3.461
1195
87.92
.1195
.1172
117.2
11720
11.72
6.3
174.4
12.83
4429
325.8
.4429
.4344
434.4
43440
43.44
1.8
49.82
3.665
1266
93.09
.1266
1241
124.1
12410
12.41
6.4
177.2
13.03
4500
331.0
.4500
.4413
441.3
44130
44.13
1.9
52.59
3.868
1336
98.26
.1336
1310
131.0
13100
13.10
6.5
179.9
13.23
4570
336.1
.4570
.4482
448.2
44820
44.82
2.0
55.36
4.072
1406
103.4
.1406
.1379
137.9
13790
13.79
6.6
182.7
13.44
4640
341.3
4640
.4550
455.0
45500
45.50
2.1
58.13
4.276
1476
108.6
.1476
.1448
144.8
14480
14.48
6.7
185.5
13.64
4711
346.5
.4710
.4619
461.9
46190
46.19
2.2
60.90
4.479
1547
113.8
.1547
.1517
151.7
15170
15.17
6.8
188.2
13.84
4781
351.7
.4781
.4688
468.8
46880
46.88
2.3
63.67
4.683
1617
118.9
.1617
.1586
158.6
15860
15.86
6.9
191.0
14.05
4851
356.8
.4851
.4757
475.7
47570
47.57
2.4
66.43
4.886
1687
124.1
.1687
.1655
165.5
16550
16.55
7.0
193.8
14.25
4922
362.0
.4921
.4826
482.6
48260
48.26
2.5
69.20
5.090
1758
129.3
.1758
.1724
172.4
17240
17.24
7.1
196.5
14.46
4992
367.2
.4992
.4895
489.5
48950
48.95
2.6
71.97
5.294
1828
134.5
.1828
.1793
179.3
17930
17.93
7.2
199.3
14.66
5062
372.3
.5062
.4964
496.4
49640
49.64
2.7
74.74
5.497
1898
139.6
.1898
.1862
186.2
18620
18.62
7.3
202.1
14.86
5132
377.5
.5132
.5033
503.3
50330
50.33
2.8
77.51
5.701
1969
144.8
.1968
.1930
193.0
19300
19.30
7.4
204.8
15.07
5203
382.7
.5203
.5102
510.2
51020
51.02
2.9
80.27
5.904
2039
150.0
.2039
.1999
199.9
19990
19.99
7.5
207.6
15.27
5273
387.9
.5273
.5171
517.1
51710
51.71
3.0
83.04
6.108
2109
155.1
.2109
.2068
206.8
20680
20.68
7.6
210.4
15.47
5343
393.0
.5343
.5240
524.0
52400
52.40
3.1
85.81
6.312
2180
160.3
.2180
.2137
213.7
21370
21.37
7.8
215.9
15.88
5484
403.4
.5484
.5378
537.8
53780
53.78
3.2
88.58
6.515
2250
165.5
.2250
.2206
220.6
22060
22.06
8.0
221.4
16.29
5625
413.7
.5625
.5516
551.6
55160
55.16
3.3
91.35
6.719
2320
170.7
.2320
.2275
227.5
22750
22.75
8.2
227.0
16.70
5765
424.1
.5765
.5654
565.4
56540
56.54
3.4
94.11
6.922
2390
175.8
.2390
.2344
234.4
23440
23.44
8.4
232.5
17.10
5906
434.4
.5906
.5792
579.2
57920
57.92
3.5
96.88
7.126
2461
181.0
.2461
.2413
241.3
24130
24.13
8.6
238.0
17.51
6047
444.7
.6046
.5929
592.9
59290
59.29
3.6
99.65
7.330
2531
186.2
.2531
.2482
248.2
24820
24.82
8.8
243.6
17.92
6187
455.1
.6187
.6067
606.7
60670
60.67
3.7
102.4
7.533
2601
191.3
.2601
.2551
255.1
25510
25.51
9.0
249.1
18.32
6328
465.4
.6328
.6205
620.5
62050
62.05
3.8
105.2
7.737
2672
196.5
.2672
.2620
262.0
26200
26.20
9.2
254.7
18.73
6468
475.8
.6468
.6343
634.3
63430
63.43
3.9
108.0
7.940
2742
201.7
.2742
.2689
268.9
26890
26.89
9.4
260.2
19.14
6609
486.1
.6609
.6481
648.1
64810
64.81
4.0
110.7
8.144
2812
206.9
.2812
.2758
275.8
27580
27.58
9.6
265.7
19.54
6750
496.5
.6749
.6619
661.9
66190
66.19
4.1
113.5
8.348
2883
212.0
.2883
.2827
282.7
28270
28.27
9.8
271.3
19.95
6890
506.8
.6890
.6757
675.7
67570
67.57
4.2
116.3
8.551
2953
217.2
.2953
.2896
289.6
28960
28.96
10.0
276.8
20.36
7031
517.1
.7031
.6895
689.5
68950
68.95
4.3
119.0
8.775
3023
222.4
.3023
.2965
296.5
29650
29.65
11.0
304.5
22.40
7734
568.9
.7734
.7584
758.4
75840
75.84
4.4
121.8
8.958
3094
227.5
.3094
.3034
303.4
30338
30.34
12.0
332.2
24.43
8437
620.6
.8437
.8274
827.4
82740
82.74
4.5
124.6
9.162
2164
232.7
.3164
.3103
310.3
31030
31.03
13.0
359.8
26.47
9140
672.3
.9140
.8963
896.3
98630
89.63
4.6
127.3
9.366
3234
237.9
.3234
.3172
317.2
31720
31.72
14.0
387.5
28.50
9843
724.0
.9843
.9652
965.2
96520
96.52
4.7
130.1
9.569
3304
243.1
.3304
.3240
324.0
32400
32.40
14.7
406.9
29.93
10340
760.2
1.033
1.014
1014
101400
101.4
4.8
132.9
9.773
3375
248.2
.3375
.3310
331.0
33100
33.10
15.0
415.2
30.54
10550
775.7
1.055
1.034
1034
103400
103.4
4.9
135.6
9.976
3445
253.4
.3445
.3378
337.8
33780
33.78
16.0
442.9
32.58
11250
827.4
1.125
1.103
1103
110300
110.3
5.0
138.4
10.18
3515
258.6
.3515
.3447
344.7
34470
34.47
17.0
470.6
34.61
11950
879.1
1.195
1.172
1172
117200
117.2
5.1
141.2
10.38
3586
263.7
.3586
.3516
351.6
35160
35.16
18.0
498.2
36.65
12660
930.9
1.265
1.241
1241
124100
124.1
5.2
143.9
10.59
3656
268.9
.3656
.3585
358.5
35850
35.85
19.0
525.9
38.68
13360
982.6
1.336
1.310
1310
131000
131.0
5.3
146.7
10.79
3726
274.1
.3726
.3654
365.4
36540
36.54
20.0
553.6
40.72
14060
1034
1.406
1.379
1379
137900
137.9
5.4
149.5
10.99
3797
279.3
.3797
.3723
372.3
37230
37.23
25.0
692.0
50.90
17580
1293
1.758
1.724
1724
172400 172. 4
5.5
152.2
11.20
3867
284.4
.3867
.3792
379.2
37920
37.92
Pressure Conversions
Lbf/ln2 = Pounds force
per square inch (psi)
1
1
1
1
1
1
1
1
psi = 27.6804 in/H2O
psi = 2.03602 in/Hg
psi = 68.9476 mbar
psi = 703.082 mm/H2O
psi = 0.0689 bar
in/H2O = 25.4 mm/H2O
in/H2O = 1.86832 mm/Hg
in/H2O = 2.49089
1999
Flow
dm3/s = Cubic decimetres per second
ft3/Min = Cubic feet per minute
1/Min = Litres per minute
1dm3/s = 2.119 ft3/Min
1dm3/s = 60 Litres/Min
1Lt/Min = 0.0353 ft3/Min
Liquid
MI = Millilitre
Fl oz = Fluid Ounce
1MI = 0.0352 Fl/oz
1 Litre = 0.21998 UK
Gallon
Force
N = Newton
Lbf = Pounds force
Kgf = Kilogram force
Weight
1 N = 0.225Lbf
1 N = 0102Kgf
1Kg = 2.2045Lb
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
Kg = Kilogram
Lb = Pound
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
Certification Markings
Country
Agency
Australia
Country
Agency
SAA
Japan
MITI
Austria
OVE
Netherlands
KEMA
Belgium
CEBEC
New Zealand
Canada
CSA
SECV
SECQ
SECWA
EANSW
ETSA
HECT
SANZ
Denmark
DEMKO
Norway
NEMKO
Republic of
South Africa
SABS
Sweden
SEMKO
Switzerland
SEV
United Kingdom
ASTA
Europe
Finland
Mark
CEBEC
Mark
EUR
KEMA
D
MANY
FEI
France
UTE
Germany
VDE
FI
BSI
B
India
ISI
Ireland
IIRS
BEAB
United States
BEAB
UL
or
®
Italy
1999
S
®
IMQ
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
Accessories: Switch Housings
Benefits
❖ IP40 and IP67 Housings with rear fixing positions
❖ Back entry versions for pressure switch connections
❖ Variations of air or electrical connections
❖ Available for all herga switching systems
❖ Unlimited options available - contact herga with your
requirements
❖ Custom designed labels and housing colours available for
volume OEM requirements
Part Number: 6819-00 Variants
Part Number: 6816-00 Variants
Part Number: 6819-01
The most economical and compact
housing, produced especially for
hergair switches. Double insulated
sealed enclosure is moulded in two
tone black and white ABS as standard.
The lid has an integral rubber sealing
gasket and captive screws. Mounting
holes and lid fixing screws are outside
the seal, thus preventing the ingress of
moisture and making the box
waterproof to IP65.
Diecast aluminium housing for
airswitch types except 6806 models.
Finished in blue stove enamel. Ideal
for use where electrical screening is
required.
Blue flexible PVC protective boot for
air and pressure switch types 6721,
6731, 6741, 6861, 6863 and 6869.
The standard 6819-00 housing is
supplied with a cable gland for cable
diameter 5mm to 7mm and a type
6418-00 air tube connector is fitted.
The housing is suitable for
airswitches except model 6806.
1999
all
Other colour variants are available
upon request as are specified fixing
positions to suit your requirements.
Where a number of airswitches are to
be fitted in one box, herga can supply
a variety of special boxes complete
with multi-way air connectors and
electrical connections as required.
Covers all electrical connections and
grips round outside of switch body.
Can be used with cable 5mm to 9mm
diameter.
We recommend a cable restraint is
used in connection with this part.
Note:
Herga can offer many other variants of electrical housings in size and colour up to IP67. We
also manufacture world-wide (plug in) switch housings with or without cordsets in conjunction
with our airswitching systems. Please contact us with your specific requirements.
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.
Rapid Response Form (Photostat and fax back)
It is our goal to give you a response within 24 hours. By completing this form it will help us to help you!
Thank you.
CUSTOMER
CONTACT NAME
FAX:
TEL:
________________________________________________PRESSURE ___________________________________________________VACUUM
INDUSTRY:
MEDICAL
CLASSIFICATION:
POOL & SPA
OEM
CHEMICAL/PROCESS
DISTRIBUTOR / RESELLER
INDUSTRIAL
END USER
OTHER
OTHER ______________________
__________________________________
REQUIREMENTS: __________________ PRESSURE. __________________ VACUUM. _________________ DIFFERENTIAL PRESSURE.
IF PRESSURE OR VACUUM MEASURED GAUGE (AS IN CATALOGUE) OR ABSOLUTE? ___________________________________________
________________ INCHES WG _________________ PSI GAUGE
HERGA TO SET
WE WILL SET
ON RISING
OPERATING RANGE: ______________TO____________±____________
ON FALLING
MAX PRESSURE/VACUUM UNIT WILL BE SUBJECTED TO ___________________________ SETTING PREFERENCE ±__________________
MAX DIFFERENTIAL (DIFF. BETWEEN RISE & FALL) ________________________________ MIN DIFFERENTIAL _______________________
MEDIA
GAS ___________________
TEMPERATURE ___________________
LIQUID _________________
TEMPERATURE ____________________ MEDIA
ELECTRICAL:
AMBIENT ___________________ TO ________________
VOLTS ______________ AC _______________/_______________ DC
______________ RESISTIVE ________________ INDUCTIVE
APPROVAL NEEDED: UL
CSA
CONTACT CONFIGURATION:
MECHANICAL:
1/8” NPT BRASS
___________________ TO ________________
MAX CURRENT: AMPS___________HP___________
LOAD DESCRIPTION ______________________________________________
OTHER _______________________________________________________________________
SINGLE POLE
MOUNTING PREFERENCE 1/8” BSPT BRASS
1/8” NPT STAINLESS
PCB MOUNT
APPLICATION (WHAT WILL SWITCH CONTROL?)
DOUBLE POLE
1/8” BSPT STAINLESS
GOLD CONTACT
SIDE SPOUT
CENTRE SPOUT
OTHER ____________________________________________________
________________________________________________________________________
________________________________________________________________________
QUANTITY REQUIRED FOR PROTOTYPE?
___________________________________
REQUIRED DATE ________________________
ANNUAL PRODUCTION QUANTITY?
___________________________________
START DATE ___________________________
CURRENT SWITCH USED?
___________________________________
PRICE RANGE __________________________
ANY PROBLEMS WITH PRESENT UNIT?
_____________________________________________________________________________
_____________________________________________________________________________
1999
FOR FURTHER INFORMATION TEL: +44 (0)1284 701422 FAX: +44 (0)1284 753112
ISSUE 01
As a consequence of our policy of continual improvement, we reserve the right to change without notice any detail in this publication. Please see our Conditions of Sale.